1、常(chang)用的電線(xian)、電纜按用途分有哪些種類(lei)?
答:按用(yong)途(tu)可分(fen)為裸導線、絕緣電(dian)(dian)(dian)(dian)(dian)線、耐(nai)熱電(dian)(dian)(dian)(dian)(dian)線、屏蔽電(dian)(dian)(dian)(dian)(dian)線、電(dian)(dian)(dian)(dian)(dian)力電(dian)(dian)(dian)(dian)(dian)纜、控制電(dian)(dian)(dian)(dian)(dian)纜、通(tong)信電(dian)(dian)(dian)(dian)(dian)纜、射頻電(dian)(dian)(dian)(dian)(dian)纜等。
2、絕緣電(dian)線有哪幾種?
答(da):常有(you)的絕(jue)(jue)(jue)緣(yuan)(yuan)電(dian)線(xian)有(you)以下幾種(zhong):聚(ju)(ju)氯乙(yi)烯(xi)絕(jue)(jue)(jue)緣(yuan)(yuan)電(dian)線(xian)、聚(ju)(ju)氯乙(yi)烯(xi)絕(jue)(jue)(jue)緣(yuan)(yuan)軟(ruan)線(xian)、丁腈(jing)聚(ju)(ju)氯乙(yi)烯(xi)混(hun)合(he)物絕(jue)(jue)(jue)緣(yuan)(yuan)軟(ruan)線(xian)、橡皮(pi)絕(jue)(jue)(jue)緣(yuan)(yuan)電(dian)線(xian)、農(nong)用地下直埋鋁芯塑料絕(jue)(jue)(jue)緣(yuan)(yuan)電(dian)線(xian)、橡皮(pi)絕(jue)(jue)(jue)緣(yuan)(yuan)棉(mian)紗紡織軟(ruan)線(xian)、聚(ju)(ju)氯乙(yi)烯(xi)絕(jue)(jue)(jue)緣(yuan)(yuan)尼(ni)龍護套電(dian)線(xian)、電(dian)力和(he)照(zhao)明用聚(ju)(ju)氯乙(yi)烯(xi)絕(jue)(jue)(jue)緣(yuan)(yuan)軟(ruan)線(xian)等。
3、電纜橋架適合(he)于何種場合(he)?
答:電(dian)纜橋架(jia)適用于(yu)一般工礦企業室(shi)內外架(jia)空敷(fu)設(she)電(dian)力電(dian)纜、控(kong)制電(dian)纜,亦(yi)可(ke)用于(yu)電(dian)信、廣(guang)播(bo)電(dian)視等部門在室(shi)內外架(jia)設(she)。
4、電纜(lan)附件(jian)有哪(na)些?
答:常用的電附件有(you)電纜(lan)終端(duan)接(jie)(jie)(jie)線盒(he)、電纜(lan)中間接(jie)(jie)(jie)線盒(he)、連接(jie)(jie)(jie)管及接(jie)(jie)(jie)線端(duan)子、鋼板接(jie)(jie)(jie)線槽、電纜(lan)橋架(jia)等。
5、什么叫電(dian)纜中間接頭?
答(da):連接電(dian)纜(lan)與電(dian)纜(lan)的(de)導體、絕(jue)緣屏(ping)蔽(bi)層和保(bao)護(hu)層,以使電(dian)纜(lan)線(xian)路連接的(de)裝置,稱(cheng)為電(dian)纜(lan)中間接頭(tou)。
6、什么叫電氣主(zhu)接線(xian)?
答(da):電(dian)氣主(zhu)接(jie)線(xian)是發電(dian)廠、變(bian)電(dian)所中(zhong)主(zhu)要電(dian)氣設備和(he)母(mu)(mu)線(xian)的連接(jie)方(fang)式,包括主(zhu)母(mu)(mu)線(xian)和(he)廠用電(dian)系統按一定的功能要求的連接(jie)方(fang)式。
7、在選(xuan)擇電(dian)力電(dian)纜的截面時,應(ying)遵照(zhao)哪些規定?
答:電(dian)(dian)(dian)(dian)力電(dian)(dian)(dian)(dian)纜(lan)的(de)(de)(de)選擇應遵照以(yi)下(xia)原則(ze):(1)電(dian)(dian)(dian)(dian)纜(lan)的(de)(de)(de)額定電(dian)(dian)(dian)(dian)壓要(yao)大于或等于安(an)裝點供電(dian)(dian)(dian)(dian)系統的(de)(de)(de)額定電(dian)(dian)(dian)(dian)壓;(2)電(dian)(dian)(dian)(dian)纜(lan)持(chi)續容許電(dian)(dian)(dian)(dian)流(liu)應等于或大于供電(dian)(dian)(dian)(dian)負載的(de)(de)(de)更大 持(chi)續電(dian)(dian)(dian)(dian)流(liu);(3)線芯截面要(yao)滿足供電(dian)(dian)(dian)(dian)系統短路時(shi)的(de)(de)(de)穩(wen)定性的(de)(de)(de)要(yao)求;(4)根(gen)據電(dian)(dian)(dian)(dian)纜(lan)長(chang)度驗算電(dian)(dian)(dian)(dian)壓降是(shi)否符合要(yao)求;(5)線路末端(duan)的(de)(de)(de)最小短路電(dian)(dian)(dian)(dian)流(liu)應能使保(bao)護裝置(zhi)可靠(kao)的(de)(de)(de)動作。
8、交聯聚(ju)乙烯電(dian)(dian)纜和油紙電(dian)(dian)纜比(bi)較有哪些優點?
答:(1)易安(an)裝,因為(wei)它允許最小彎曲半徑(jing)小、且重(zhong)量輕;(2)不受線路(lu)落差*;(3)熱性(xing)能好,允許工(gong)作溫(wen)度高、傳輸(shu)容量大;(4)電(dian)纜(lan)附件簡單,均為(wei)干式(shi)結構;(5)運(yun)行維(wei)護簡單,無漏(lou)油問題;(6)價格較低(di);(7)可靠性(xing)高、故(gu)障率低(di);(8)制造工(gong)序(xu)少(shao)、工(gong)藝簡單,經濟效益顯著。
9、固定(ding)交流(liu)單芯電纜的夾具有(you)什(shen)么要求?為什(shen)么?
答:夾(jia)具(ju)應無鐵(tie)件(jian)(jian)構成閉合磁路,這是因為當電纜(lan)線(xian)芯(xin)通過(guo)電流(liu)時,在其周圍產(chan)生磁力(li)線(xian),磁力(li)線(xian)與通過(guo)線(xian)芯(xin)的電流(liu)大小成正比,若(ruo)使(shi)用鐵(tie)件(jian)(jian)等導(dao)磁材(cai)料,根據電磁感應可知,將在鐵(tie)件(jian)(jian)中產(chan)生渦流(liu)使(shi)電纜(lan)發(fa)熱(re),甚(shen)至燒(shao)壞電纜(lan)。所以不(bu)可使(shi)用鐵(tie)件(jian)(jian)作單芯(xin)交流(liu)電纜(lan)的固定夾(jia)具(ju)。
10、以下的(de)熱縮電纜頭(tou)的(de)附件的(de)更大 特點和優點是什么?
答:熱縮(suo)(suo)附(fu)(fu)件的(de)更大(da) 特點是用(yong)應(ying)力管代替傳統的(de)應(ying)力錐,它不僅簡化(hua)了(le)施工(gong)工(gong)藝,還縮(suo)(suo)小了(le)接頭的(de)終端的(de)尺寸,安(an)裝方便,省時省工(gong),性能優越(yue),節約金屬(shu)。熱縮(suo)(suo)電纜(lan)附(fu)(fu)件集灌注式(shi)和(he)干包(bao)式(shi)為一體,集合(he)了(le)這兩種附(fu)(fu)件的(de)優點。
11、電纜(lan)敷(fu)設前應進行(xing)哪(na)些檢查工作?
答:(1)支架(jia)應齊全、油(you)漆完整。(2)電(dian)纜型號、電(dian)壓(ya)(ya)、規格(ge)符合設計。(3)電(dian)纜絕緣良好,當對(dui)油(you)紙(zhi)電(dian)纜的(de)(de)密封有懷疑時,應進行受潮判斷(duan);直埋電(dian)纜與小底電(dian)纜應經直流耐壓(ya)(ya)試(shi)難合格(ge);充(chong)油(you)電(dian)纜的(de)(de)油(you)樣應試(shi)驗(yan)合格(ge)。(4)充(chong)油(you)電(dian)纜的(de)(de)油(you)壓(ya)(ya)不宜低于1.47MPa。
11、交(jiao)聯熱收縮電纜附(fu)件有哪(na)些優點?
答(da):這是一種新(xin)型(xing)材料,它與現在(zai)其他類型(xing)附件比較具(ju)有電(dian)氣(qi)(qi)性(xing)能優越(yue)、體積小(xiao)、質量小(xiao)、安(an)裝簡便、材料配套等優點,另外還具(ju)有耐氣(qi)(qi)候、抗污穢性(xing)、阻(zu)燃自熄等能力。
12、對(dui)油紙絕(jue)緣電力電纜密封有懷疑時,如(ru)何用較簡單(dan)的辦法檢查電纜絕(jue)緣紙是否受潮?
答:把(ba)電纜(lan)(lan)絕緣紙點燃或放入150℃左右的電纜(lan)(lan)油中檢查,無“嘶(si)嘶(si)”聲或白色泡沫出現,說明(ming)未受潮(chao)。
13、電纜標志牌應(ying)注(zhu)明什么內容(rong)?編寫有何(he)要求?
答(da):標志牌上應注明電纜線路設計(ji)編號(hao)、電纜型(xing)號(hao)、規格及始點(dian),并聯使用(yong)的電纜應有順序號(hao)。要求字跡清晰(xi)、不易脫落。
14、直埋電纜(lan)的方(fang)位標志應設置在哪些位置?
答:在(zai)電纜兩端,電纜直線(xian)段50~100m處電纜接頭幾(ji)電纜改變(bian)方向的彎(wan)角處。
15、制(zhi)作電纜接頭(tou)用的黃(huang)臘綢(chou)帶(dai)(dai)、黑玻璃漆帶(dai)(dai)、無堿玻璃絲帶(dai)(dai)等,施工前如何進行排潮處理?
答:(1)恒溫(wen)干燥法(fa):將絕(jue)緣(yuan)帶卷成直徑為25~30mm小卷,放(fang)入(ru)110~120℃恒溫(wen)干燥箱(xiang)內烘4~5h,冷卻干取出(chu),放(fang)入(ru)干燥的(de)(de)(de)密封筒內。(2)油(you)(you)浸排(pai)潮法(fa):將絕(jue)緣(yuan)帶小卷放(fang)入(ru)恒溫(wen)在120~130℃的(de)(de)(de)電纜油(you)(you)中(zhong),離鍋底(di)保(bao)持30mm距離,經一定時間后(hou)油(you)(you)面不(bu)再產生(sheng)泡沫(mo)后(hou)取出(chu),裝(zhuang)入(ru)貯有電纜油(you)(you)的(de)(de)(de)桶中(zhong),油(you)(you)位應超過所(suo)有裝(zhuang)入(ru)的(de)(de)(de)物體并將其(qi)密封。
16、電纜外護層的作用是什么?
答(da):保護內護層不受機械損傷和化學(xue)腐(fu)蝕,增強機械強度。
17、室外電(dian)纜溝應符合(he)哪些要求(qiu)?
答:電纜溝上(shang)部應比地面稍(shao)高,加蓋用混(hun)凝土制作的蓋板,電纜應平敷在支架上(shang),有良好的排(pai)水管。
18、電纜內(nei)護層(ceng)的作用是什么(me)?
答;使絕(jue)緣層不(bu)會與水、空氣或(huo)其他物體接(jie)觸,防止(zhi)絕(jue)緣受(shou)潮和絕(jue)緣層不(bu)受(shou)機械傷害(hai)。
19、使用鋼(gang)絲鉗時(shi)應注意(yi)些什么?
答:使(shi)用前,一定(ding)要(yao)檢查絕(jue)緣柄的絕(jue)緣是否(fou)完(wan)好無(wu)損(sun),使(shi)用時不可用鋼(gang)絲(si)鉗(qian)剪切超過規格所允許的金屬線(xian)材,并禁止用鋼(gang)絲(si)鉗(qian)代(dai)替錘(chui)子敲打工具,以免損(sun)壞。
20、什么叫絕緣強度?
答:絕緣物質(zhi)在(zai)電場中,當電場強(qiang)度(du)增大到(dao)某一極限時(shi)就會被擊(ji)穿,這個(ge)導致(zhi)絕緣擊(ji)穿的電場強(qiang)度(du)稱(cheng)為絕緣強(qiang)度(du)。
22、對電纜導體連(lian)接(jie)點的機械強度(du)有何要求?
答(da):連接點的(de)(de)機(ji)械強度,一般低于電纜導體(ti)本身(shen)的(de)(de)抗拉(la)強度,對(dui)于固(gu)定敷設的(de)(de)電力電纜,其連接點的(de)(de)抗拉(la)強度要求不(bu)低于導體(ti)本身(shen)抗拉(la)強度的(de)(de)60%。
23、電力電纜的絕緣層材料應具備哪(na)些主要性能?
答;應具備下列主(zhu)要性(xing)(xing)能:(1)高的(de)(de)擊穿強度;(2)低(di)的(de)(de)介質損耗;(3)相當高的(de)(de)絕緣(yuan)電(dian)阻;(4)優良的(de)(de)耐放(fang)電(dian)性(xing)(xing)能;(5)具有一定的(de)(de)柔軟性(xing)(xing)和機械(xie)強度;(6)絕緣(yuan)性(xing)(xing)能長期穩定。
24、機(ji)械(xie)敷設電纜時,牽引強(qiang)度有何規定(ding)?
答:對于銅芯(xin)電(dian)纜(lan),當牽引(yin)頭部時(shi),允(yun)許牽引(yin)強度為(wei)70N/cm;對于鋁芯(xin)電(dian)纜(lan),當牽引(yin)頭部時(shi),允(yun)許牽引(yin)強度為(wei)40N/cm;若利用鋼絲網(wang)套(tao)牽引(yin)時(shi),鉛護套(tao)電(dian)纜(lan)允(yun)許強度為(wei)10N/cm;鉛護套(tao)電(dian)纜(lan)為(wei)40N/cm。
25、對(dui)電纜(lan)保(bao)護管有何規(gui)定?
答(da):(1)電纜需(xu)要穿保護管敷設時,管子內徑不(bu)應小于電纜外(wai)徑的1.5倍,混(hun)凝土管、陶土管、石棉、水泥管的內徑不(bu)應小于100mm;
(2)電(dian)纜管的彎(wan)曲半(ban)徑應符合所穿入電(dian)纜彎(wan)曲半(ban)徑的規定;
(3)每根管子最多不(bu)應超過三(san)個彎頭,直角(jiao)彎不(bu)應多于2個。
26、如何測量(liang)電纜護套的外徑?
答:在護(hu)套(tao)圓周上均勻分布(bu)的五點處,測量護(hu)套(tao)外徑(jing)和(he)其平均值(zhi),其平均外徑(jing)既為護(hu)套(tao)的外徑(jing)。
27、不同截面的銅(tong)芯(xin)電纜如何(he)連接?
答(da):不同(tong)截(jie)面(mian)的(de)銅芯電纜連接,可采用開口(kou)弱背(bei)銅接管(guan),以(yi)錫焊(han)法連接,也可用純銅棒按(an)不同(tong)的(de)截(jie)面(mian)要求(qiu)連接成銅接管(guan),以(yi)壓接法連接。
28、簡(jian)述10KV交(jiao)聯電纜熱縮式(shi)制作戶內終端頭(tou)的(de)過程?
答;(1)準備(bei)階段(duan):檢(jian)查(cha)(cha)熱(re)縮(suo)電纜附件是否(fou)齊(qi)備(bei),型號是否(fou)相配,檢(jian)查(cha)(cha)并確認電纜有無潮(chao)氣后,檢(jian)查(cha)(cha)電纜。
(2)切除(chu)多余電纜(lan),根(gen)據現(xian)場情況決(jue)定電纜(lan)長度。
(3)剝除護層。
(4)焊接(jie)(jie)(jie)接(jie)(jie)(jie)地(di)線,將接(jie)(jie)(jie)地(di)線焊接(jie)(jie)(jie)在(zai)鋼(gang)帶(dai)上。
(5)填充三叉口及繞包密封膠。
(6)安裝三(san)芯(xin)分支護套(tao),將護套(tao)套(tao)入根(gen)部,從(cong)中部開(kai)始收縮,先往根(gen)部,再往指部。
(7)剝(bo)銅 帶(dai)和外半導電層(ceng),剝(bo)切三(san)芯分支套(tao)口20mm以上的(de)銅帶(dai),嚴禁(jin)損傷主絕緣,清(qing)除干凈半導電層(ceng)。
(8)安裝應力管,管口端部分支套對接后熱縮。
(9)安裝(zhuang)接線端(duan)子。
(10)安裝(zhuang)絕緣管。
(11)安(an)裝密封管。
(12)核相后安裝(zhuang)相色管。
29、戶內、戶外預制式終端(duan)安裝步驟有哪些?
答:(1) 將電纜按預定位(wei)置就位(wei)、固定、清(qing)潔表面(mian),參照說明書剝除外護套,如(ru)有(you)特殊需要,外護套剝切長度可調整,分(fen)別由銅(tong)帶、外護套鎧裝引出2組地線(xian)。
(2) 由外(wai)護套口(kou)向上(shang)量取需要尺寸,切除多(duo)余電纜(lan),套入熱縮三(san)指套至三(san)叉口(kou)根(gen)部由中間加熱收縮,由指套上(shang)口(kou)向上(shang)量取規定尺寸(35kv為(wei)350~380mm)。去掉多(duo)余銅帶(保留20mm),再保留半導體預定位(wei)置,壓接出線(xian)端子(zi)密封。
30、電(dian)(dian)線電(dian)(dian)纜的應用主要分為(wei)三大類 :
(1)、電力系統
電(dian)(dian)力(li)系(xi)統采用的電(dian)(dian)線(xian)電(dian)(dian)纜(lan)產(chan)品主要(yao)有架空(kong)裸電(dian)(dian)線(xian)、匯(hui)流排(pai)(母線(xian))、電(dian)(dian)力(li)電(dian)(dian)纜(lan)(塑料線(xian)纜(lan)、油紙力(li)纜(lan)(基本被塑料電(dian)(dian)力(li)電(dian)(dian)纜(lan)代(dai)(dai)替)、橡套(tao)線(xian)纜(lan)、架空(kong)絕(jue)緣電(dian)(dian)纜(lan))、分支電(dian)(dian)纜(lan)(取代(dai)(dai)部分母線(xian))、電(dian)(dian)磁線(xian)以(yi)及電(dian)(dian)力(li)設備(bei)(bei)用電(dian)(dian)氣裝備(bei)(bei)電(dian)(dian)線(xian)電(dian)(dian)纜(lan)等。
(2)、信(xin)息(xi)傳輸系統(tong)
用于信息傳輸系統(tong)的電(dian)(dian)(dian)線(xian)電(dian)(dian)(dian)纜(lan)(lan)(lan)主(zhu)要(yao)有市話電(dian)(dian)(dian)纜(lan)(lan)(lan)、電(dian)(dian)(dian)視電(dian)(dian)(dian)纜(lan)(lan)(lan)、電(dian)(dian)(dian)子(zi)線(xian)纜(lan)(lan)(lan)、射頻電(dian)(dian)(dian)纜(lan)(lan)(lan)、光纖(xian)纜(lan)(lan)(lan)、數據電(dian)(dian)(dian)纜(lan)(lan)(lan)、電(dian)(dian)(dian)磁線(xian)、電(dian)(dian)(dian)力(li)通訊或其他(ta)復合電(dian)(dian)(dian)纜(lan)(lan)(lan)等。
(3)、機械(xie)設備、儀器儀表系統
此部分除(chu)架空裸電(dian)線(xian)外幾乎其他所有產品均有應(ying)用,但主要是電(dian)力電(dian)纜(lan)、電(dian)磁線(xian)、數(shu)據電(dian)纜(lan)、儀器儀表線(xian)纜(lan)等。
31、電線電纜產品主(zhu)要分(fen)為五大類:
(1)、裸電(dian)線及裸導體(ti)制品 本類(lei)產品的(de)主(zhu)(zhu)要(yao)特征是:純的(de)導體(ti)金屬,無絕緣及護(hu)套層,如(ru)鋼芯(xin)鋁(lv)絞(jiao)線、銅鋁(lv)匯流排、電(dian)力機車線等;加(jia)工(gong)(gong)工(gong)(gong)藝主(zhu)(zhu)要(yao)是壓力加(jia)工(gong)(gong),如(ru)熔煉、壓延、拉制、絞(jiao)合/緊壓絞(jiao)合等;產品主(zhu)(zhu)要(yao)用在城郊、農(nong)村、用戶主(zhu)(zhu)線、開關柜等。
(2)、電(dian)力(li)電(dian)纜(lan)(lan)本(ben)類產品(pin)主(zhu)要特征是:在導體外擠(ji)(繞)包(bao)(bao)絕(jue)緣層(ceng),如架(jia)空絕(jue)緣電(dian)纜(lan)(lan),或(huo)幾芯(xin)絞合(he)(對應電(dian)力(li)系統的相(xiang)線、零線和地線),如二芯(xin)以上架(jia)空絕(jue)緣電(dian)纜(lan)(lan),或(huo)再增加護套(tao)層(ceng),如塑料/橡套(tao)電(dian)線電(dian)纜(lan)(lan)。主(zhu)要的工(gong)藝(yi)技術有(you)拉制、絞合(he)、絕(jue)緣擠(ji)出(chu)(繞包(bao)(bao))、成纜(lan)(lan)、鎧裝、護層(ceng)擠(ji)出(chu)等,各種產品(pin)的不同工(gong)序組合(he)有(you)一定區別。
產品主(zhu)要用在發、配、輸、變(bian)、供電(dian)(dian)線路(lu)中的強電(dian)(dian)電(dian)(dian)能(neng)傳輸,通過(guo)的電(dian)(dian)流大(幾十安至幾千安)、電(dian)(dian)壓高(220V至500kV及以(yi)上)。
(3)、電(dian)(dian)(dian)氣裝(zhuang)備用(yong)(yong)(yong)電(dian)(dian)(dian)線(xian)(xian)(xian)電(dian)(dian)(dian)纜(lan)(lan)該(gai)類(lei)產品(pin)主(zhu)要(yao)特征是:品(pin)種(zhong)規格繁(fan)多(duo),應用(yong)(yong)(yong)范(fan)圍廣泛,使用(yong)(yong)(yong)電(dian)(dian)(dian)壓在(zai)1kV及以下較(jiao)多(duo),面對特殊場(chang)合不(bu)斷衍生(sheng)新的(de)產品(pin),如耐(nai)火線(xian)(xian)(xian)纜(lan)(lan)、阻燃線(xian)(xian)(xian)纜(lan)(lan)、低(di)煙無鹵(lu)/低(di)煙低(di)鹵(lu)線(xian)(xian)(xian)纜(lan)(lan)、防白蟻、防老鼠(shu)線(xian)(xian)(xian)纜(lan)(lan)、耐(nai)油(you)/耐(nai)寒/耐(nai)溫(wen)/耐(nai)磨線(xian)(xian)(xian)纜(lan)(lan)、醫用(yong)(yong)(yong)/農用(yong)(yong)(yong)/礦用(yong)(yong)(yong)線(xian)(xian)(xian)纜(lan)(lan)、薄壁電(dian)(dian)(dian)線(xian)(xian)(xian)等。
(4)、通訊電(dian)纜(lan)(lan)(lan)及(ji)光纖(簡略介紹)隨著近二(er)十(shi)多(duo)年(nian)來,通訊行(xing)業(ye)的飛速發(fa)展,產品也有(you)驚人的發(fa)展速度。從(cong)過去的簡單的電(dian)話(hua)(hua)電(dian)報線纜(lan)(lan)(lan)發(fa)展到幾千對的話(hua)(hua)纜(lan)(lan)(lan)、同軸纜(lan)(lan)(lan)、光纜(lan)(lan)(lan)、數據電(dian)纜(lan)(lan)(lan),甚至組合通訊纜(lan)(lan)(lan)等。
該類產品結構尺寸通常(chang)較(jiao)小而均勻,制(zhi)造(zao)精度要求高。
(5)、電(dian)磁(ci)線(繞組線)主要用于各種電(dian)機、儀器儀表等。
電線(xian)電纜的衍生(sheng)/新產品
電(dian)線電(dian)纜的衍(yan)生(sheng)/新產(chan)品(pin)主要(yao)(yao)是(shi)因應(ying)用(yong)場(chang)合、應(ying)用(yong)要(yao)(yao)求(qiu)不同及(ji)裝備(bei)的方便性和降低(di)裝備(bei)成本等(deng)的要(yao)(yao)求(qiu),而采(cai)用(yong)新材料(liao)(liao)、特殊材料(liao)(liao)、或改變(bian)產(chan)品(pin)結構、或提高工藝(yi)要(yao)(yao)求(qiu)、或將不同品(pin)種的產(chan)品(pin)進行組合而產(chan)生(sheng)。
采用不同材料如(ru)阻燃線(xian)(xian)纜(lan)、低(di)煙無鹵/低(di)煙低(di)鹵線(xian)(xian)纜(lan)、防(fang)白蟻、防(fang)老鼠線(xian)(xian)纜(lan)、耐(nai)(nai)油/耐(nai)(nai)寒(han)/耐(nai)(nai)溫線(xian)(xian)纜(lan)等;
改變產品結構如(ru):耐火電纜等;
提高工藝要求如(ru):醫用線(xian)纜等;
組合產品如(ru):OPGW等;
方便安裝和(he)降(jiang)低(di)裝備成本(ben)如:預制分(fen)支電(dian)纜等(deng)。
32、母線裝置施工(gong)完,應進(jin)行哪些(xie)檢查?
答:應進(jin)行下列檢(jian)查:
(1)金屬構件的加工(gong)、配制、焊接螺接應符合規定(ding);
(2)各(ge)部螺栓、墊圈、開口(kou)銷等零(ling)部件應齊全可靠;
(3)母(mu)線配制及安裝(zhuang)架應符合(he)規定,相間及對地電氣距離符合(he)要(yao)求;
(4)瓷件、鐵(tie)件及膠合處應(ying)完整,充油套管應(ying)無(wu)滲油,油位正常;
(5)油漆(qi)完整(zheng),相(xiang)色正確,接地良好。
33、在35kv及以下(xia)電(dian)力電(dian)纜接頭中,改善其護套(tao)斷開處電(dian)場(chang)分布的方法有幾種(zhong)(請列出五種(zhong)),并簡述(shu)其方法。
答:(1)脹喇叭(ba)口:在鉛包割斷處把鉛包邊緣撬(qiao)起,成喇叭(ba)狀(zhuang),其邊緣應光(guang)滑、圓(yuan)整(zheng)、對稱(cheng)。
(2)預(yu)留(liu)統包絕緣:在鉛包切口至電纜芯線分(fen)開點(dian)之間(jian)留(liu)有一段統包絕緣紙。
(3)切除半導(dao)(dao)電紙(zhi):將半導(dao)(dao)電紙(zhi)切除到喇(la)叭口以下。
(4)包繞應力錐(zhui):用絕緣包帶和導電金(jin)屬材料包成(cheng)錐(zhui)形,人為地將屏蔽層擴(kuo)大,以(yi)改善電場分布。
(5)等(deng)電(dian)位法:對(dui)于干包型或交聯聚乙烯電(dian)纜頭,在各線(xian)芯(xin)概況絕緣表面上(shang)包一段金屬(shu)帶,并將(jiang)其連接在一起。
(6)裝設應力控(kong)制管(guan):對于35kv及發下熱(re)縮(suo)管(guan)電纜頭,首(shou)先(xian)從線芯銅屏(ping)(ping)蔽層末端(duan)方向經半導體(ti)帶至(zhi)線芯絕緣概況包繞2層半導體(ti)帶,然后(hou)將相應規格折應力管(guan),套(tao)在銅屏(ping)(ping)蔽的末端(duan)處,熱(re)縮(suo)成形。
34、電(dian)纜支(zhi)架的加(jia)工應符合哪些要(yao)求?
答:(1)鋼(gang)材應平直,無(wu)明顯扭(niu)曲(qu),下料誤差應在(zai)5mm范圍內,切口應無(wu)卷邊,毛(mao)剌;
(2)支(zhi)架應焊(han)接牢固,無顯蓍變形,各橫撐(cheng)間(jian)的垂直(zhi)凈(jing)距與設計(ji)偏差不應大于5mm;
(3)金屬支架必(bi)須進行防腐處(chu)理,位于(yu)濕熱、鹽、霧以及有化學(xue)腐蝕地區(qu)時,應(ying)根據設(she)計作特(te)殊的防腐處(chu)理。
35、列(lie)舉出你熟(shu)悉的電(dian)纜架。
答:拼(pin)焊式(shi)E型架、裝配式(shi)E型架、橋式(shi)電(dian)纜架、電(dian)纜托架、掛(gua)鉤式(shi)支(zhi)架、單根電(dian)纜支(zhi)架等。
36、敷設電纜應滿足哪些要(yao)求?
答:應滿足以下要求:
(1)安(an)全(quan)運行(xing)方(fang)面,盡可(ke)能避免各種外(wai)來損壞,提高電纜(lan)線路的供電可(ke)靠性;
(2)經濟方面,從投(tou)資最省(sheng)的方面考慮(lv);
(3)施工方面,電纜線路的路徑(jing)必須便于(yu)旋工和投運后(hou)的維修。
37、制作電纜(lan)終端(duan)頭(tou)或中間接頭(tou)的絕(jue)緣材料有哪些?
答:有絕緣(yuan)膠(jiao)、絕緣(yuan)帶、絕緣(yuan)管(guan)、絕緣(yuan)手套、絕緣(yuan)樹脂等。
38、簡述電纜頭制(zhi)(zhi)作的一般操作程序。答:(1)制(zhi)(zhi)作前(qian)的準備:包括○1閱讀安裝說明書;○2察看現場;○3備料;○4電纜試潮(chao);○5制(zhi)(zhi)作前(qian)測試等(deng)。
(2)接頭(tou)的(de)制(zhi)作過程:包(bao)括○1割(ge)斷多(duo)余電(dian)纜;○2電(dian)纜保護層的(de)剝(bo)切;○3導(dao)體(ti)連接;○4包(bao)繞絕(jue)緣(或收縮管材);○5安裝接頭(tou)外(wai)殼;○6灌注(zhu)絕(jue)緣劑;○7進行密封(feng)處理等。
(3)制作后電氣測試。
39、電(dian)纜保護管的(de)加(jia)工應符合哪些要求?
答:(1)管口應*剌和尖銳楞角,管口宜做成喇(la)叭形。
(2)電纜管在彎(wan)(wan)制后,不(bu)應有(you)裂縫和顯(xian)著的凹癟現象,其彎(wan)(wan)扁程度不(bu)宜大于管子外徑10%;電纜管的彎(wan)(wan)曲半徑不(bu)應小(xiao)于所穿入(ru)電纜的最小(xiao)允許彎(wan)(wan)曲半徑。
(3)金屬管應在(zai)外表(biao)涂(tu)防(fang)腐(fu)漆(qi)(qi)或瀝(li)表(biao),鍍鋅管鋅層剝落處(chu)也應涂(tu)以防(fang)腐(fu)漆(qi)(qi)。
40、電纜的排列符合哪(na)些要求?答:(1)電力電纜和控纜不應配置在(zai)同(tong)一(yi)層支(zhi)架上。
(2)高、低壓(ya)(ya)電纜,強、弱電控纜應按須序分層配置(zhi),一般情況宜由上而下(xia),但在含有35kv以上高壓(ya)(ya)電纜引入柜盤時,為滿足彎曲半徑,可(ke)由下(xia)面上配置(zhi)。
41、電纜溝內敷設電纜的方法(fa)是什么?
答:在電(dian)纜(lan)溝內敷(fu)設電(dian)纜(lan)的方法(fa)(fa)與直埋電(dian)纜(lan)的敷(fu)設方法(fa)(fa)相(xiang)仿,一般可將滑(hua)輪放在溝內,施放完畢,將電(dian)纜(lan)放于(yu)溝底或支架上,并(bing)在電(dian)纜(lan)上綁扎電(dian)纜(lan)標牌。
42、電纜(lan)敷設(she)的(de)常用設(she)備有(you)哪些(xie)?
答(da):(1)空氣壓縮機,主(zhu)要用(yong)來破(po)壞路(lu)面,為以(yi)后敷設電纜作準備;
(2)電(dian)(dian)動卷揚機(ji)或(huo)電(dian)(dian)纜牽引(yin)機(ji),主要用(yong)來拖電(dian)(dian)纜;
(3)電纜輸(shu)送機(ji),配(pei)合(he)牽(qian)引機(ji)使用來克服巨大的摩擦力,減輕對電纜的損壞;
(4)電纜盤放(fang)線支架(jia);
(5)滾輪裝置;
(6)防捻 ,減鋼絲(si)繩(sheng)出(chu)現的扭曲(qu);
(7)電纜(lan)盤制動裝置;
(8)張力計。
43、電(dian)(dian)纜(lan)溝(gou)中支架安(an)裝距(ju)離的(de)要(yao)求如何?答:電(dian)(dian)纜(lan)固定于(yu)電(dian)(dian)纜(lan)溝(gou)和隧(sui)道的(de)墻上(shang),水平裝置(zhi)時,當電(dian)(dian)纜(lan)外徑(jing)(jing)等于(yu)或小(xiao)于(yu)50mm時應每(mei)(mei)隔(ge)1m加(jia)一支撐;外徑(jing)(jing)大(da)于(yu)50mm的(de)電(dian)(dian)纜(lan)每(mei)(mei)隔(ge)0.6m加(jia)一支撐;排成三角形的(de)單電(dian)(dian)纜(lan),每(mei)(mei)隔(ge)1m應用(yong)綁帶扎牢,垂直裝置(zhi)時,每(mei)(mei)隔(ge)1~1.5m加(jia)以固定。
44、如何處理電(dian)(dian)力電(dian)(dian)纜與控制電(dian)(dian)纜在同一托架的安裝?
答(da):電(dian)力電(dian)纜與控制電(dian)纜一(yi)般不(bu)應(ying)敷設在(zai)同一(yi)托(tuo)架內,當電(dian)纜較少而將控纜與電(dian)力電(dian)纜敷設在(zai)同一(yi)托(tuo)架內時,應(ying)用隔板(ban)隔開(kai)。
45、電(dian)纜隧道內(nei)如何裝設(she)接(jie)地線?
答:隧道和(he)溝的(de)全長應裝設(she)連續的(de)接(jie)地(di)線(xian),接(jie)地(di)線(xian)應和(he)所有的(de)支(zhi)架相(xiang)連,兩頭(tou)和(he)接(jie)地(di)極連通。接(jie)地(di)線(xian)的(de)規格(ge)應符(fu)合設(she)計要求。電纜鉛包和(he)鎧裝除了(le)有絕緣要求外(wai),應全部相(xiang)互連接(jie)并和(he)接(jie)地(di)線(xian)相(xiang)連,電纜架和(he)接(jie)地(di)線(xian)均應涂防銹漆(qi)或鍍鋅。
46、對于電纜孔洞的防(fang)火封堵有何要求(qiu)?
答:對于(yu)較大的電(dian)纜貫穿(chuan)孔(kong)洞,如(ru)電(dian)纜貫穿(chuan)樓(lou)板處等,采用防火(huo)堵(du)(du)料(liao)(liao)封(feng)堵(du)(du)時,應根據實際(ji)情況,先在(zai)電(dian)纜表面涂四至六層(ceng)防火(huo)涂料(liao)(liao),長度自孔(kong)洞以(yi)下(xia)1.5m左右,再用耐火(huo)材料(liao)(liao)加工(gong)成具有一定強度的板托(tuo)防火(huo)堵(du)(du)料(liao)(liao),保證封(feng)堵(du)(du)后(hou)牢(lao)固并(bing)便于(yu)更換電(dian)纜時拆裝,封(feng)堵(du)(du)密(mi)實無孔(kong)隙以(yi)有效(xiao)地堵(du)(du)煙堵(du)(du)火(huo)。
47、噴燈點火前應注意哪些檢查?
答(da):應進行下(xia)列各(ge)項檢查:
(1)打氣(qi)筒(tong)是否(fou)漏油或滲油,油桶及噴嘴處(chu)是否(fou)漏油、漏氣(qi);
(2)油(you)(you)桶內的(de)油(you)(you)量是否(fou)超過(guo)油(you)(you)桶容量的(de)3/4,加油(you)(you)的(de)螺(luo)絲塞是否(fou)擰緊(jin)。
48、使用噴(pen)燈應注意哪(na)些(xie)事項(xiang)?
答:(1)噴燈更大 注油量為(wei)油筒(tong)容積的3/4;
(2)開始打氣壓力不要太大,點燃后火焰由黃變藍(lan)即(ji)可使(shi)用;
(3)周圍不(bu)得有易燃物,空氣要流(liu)通;
(4)停用時先(xian)關閉(bi)調(diao)節開關,火熄后,慢慢旋(xuan)松(song)油孔蓋(gai)放氣,空氣放完(wan)后,要要旋(xuan)松(song)調(diao)節開關,完(wan)全冷卻后再旋(xuan)松(song)孔蓋(gai);
(5)煤(mei)油(you)噴燈(deng)與汽油(you)噴燈(deng)要(yao)分開使用。
49、手動油壓鉗有何用(yong)途?如何操作(zuo)?
答:兩根導(dao)線的連(lian)接(jie)通(tong)常是將兩導(dao)線端穿(chuan)入(ru)相同材(cai)料制(zhi)成的壓(ya)管中,用(yong)壓(ya)接(jie)鉗擠壓(ya)數個(ge)坑,使(shi)導(dao)線連(lian)接(jie)在一起,壓(ya)接(jie)時,手(shou)柄向(xiang)上抬起時,柱塞(sai)向(xiang)外移(yi)動(dong),進(jin)(jin)(jin)油(you)(you)(you)(you)閥下(xia)腔產(chan)生真(zhen)空,油(you)(you)(you)(you)箱內(nei)的油(you)(you)(you)(you)進(jin)(jin)(jin)入(ru)柱塞(sai)腔。手(shou)柄下(xia)壓(ya)時,柱塞(sai)向(xiang)內(nei)移(yi)動(dong),油(you)(you)(you)(you)受壓(ya)后,使(shi)進(jin)(jin)(jin)油(you)(you)(you)(you)閥關閉,打開出油(you)(you)(you)(you)閥,使(shi)油(you)(you)(you)(you)壓(ya)進(jin)(jin)(jin)入(ru)液壓(ya)缸,推動(dong)活塞(sai)和陽模(mo),陽、陰(yin)模(mo)之間放有壓(ya)接(jie)管,當壓(ya)接(jie)被擠壓(ya)的坑深到一定值時,開啟回油(you)(you)(you)(you)閥,活塞(sai)自動(dong)返回,壓(ya)完(wan)一個(ge)坑后,移(yi)動(dong)壓(ya)鉗,再(zai)壓(ya)下(xia)一個(ge)。
50、常(chang)用低壓電(dian)力(li)電(dian)纜按絕緣和保護(hu)層的不同,主(zhu)要可分為哪幾類?
答:(1)油浸紙絕緣鉛包(或(huo)鋁包)電力電纜;
(2)不(bu)滴流油浸紙絕(jue)緣電力電纜;
(3)聚氯乙烯絕緣聚氯乙烯護套電(dian)力(li)電(dian)纜;
(4)交聯聚氯乙烯絕緣聚乙烯護套電力電纜;
(5)交聯聚(ju)氯乙(yi)烯絕緣(yuan)聚(ju)氯乙(yi)烯護套(tao)電力電纜;
(6)橡皮絕緣電力電纜。
51、常用(yong)絕緣(yuan)材料的類別哪(na)些?舉(ju)例說(shuo)明?
答:(1)無機絕緣(yuan)材料:有云母、石(shi)棉、大理石(shi)、瓷器、玻璃等(deng);
(2)有機絕緣材料(liao):有樹脂、橡膠、紙、麻、棉紗等(deng);
(3)混合絕緣材(cai)料(liao):用以上絕緣材(cai)料(liao)加(jia)工(gong)而成(cheng)型的(de)名種絕緣材(cai)料(liao)。
52、在哪種情況下采用排管敷設?有(you)什(shen)么優點?
答:排管敷設一般(ban)用在(zai)與其他(ta)建筑(zhu)物(wu)、公(gong)路或(huo)鐵路相交叉的地方(fang),有時也在(zai)建筑(zhu)物(wu)密集區內采用。主(zhu)要優點是占地少,能承受(shou)大的荷(he)重,電纜相互間互不影響,比較安(an)全。
53、何謂電纜(lan)長期允(yun)許載流量?
答:電(dian)纜長(chang)期(qi)允許(xu)載流量是指在電(dian)纜內通過規定電(dian)流時,在熱(re)穩定后,電(dian)纜導體(ti)達到長(chang)期(qi)允許(xu)工作溫度時的(de)電(dian)流數值。
54、決定電(dian)纜長期允許(xu)載(zai)流量的因素(su)有(you)哪(na)些?
答:有(you)以下三個因素決定:
(1)電(dian)纜的長期(qi)容許工作溫度;
(2)電纜(lan)本身的散熱性能;
(3)電纜裝置情況及周圍環境的散熱條(tiao)件(jian)。
55、電(dian)纜(lan)的敷設方(fang)式有幾種?
答:有(you)以下幾種:
(1)直埋在(zai)地下(xia);
(2)安裝在電纜溝內;
(3)安裝在地下(xia)隧(sui)道內;
(4)安裝在建筑物(wu)內部墻上(shang)或天棚上(shang);
(5)安(an)裝在橋架上;
(6)敷(fu)設在排管內(nei);
(7)敷設在水底。
56、如何進行(xing)電纜管的(de)連(lian)接工作?
答:電纜管連接(jie)時,必須用扣(kou)和(he)管接(jie)頭連接(jie),如采(cai)用焊(han)接(jie)時,不(bu)能直接(jie)對(dui)焊(han),連接(jie)處要套上一(yi)段粗管再進行焊(han)接(jie),以免焊(han)渣(zha)掉(diao)入管內。
57、制(zhi)作電纜(lan)頭時,對上下扳彎電纜(lan)芯線有(you)何要(yao)求?
答:扳彎線(xian)芯時,不(bu)得損傷(shang)紙絕緣,芯線(xian)的(de)彎曲半(ban)徑不(bu)得小于電(dian)纜線(xian)芯的(de)10倍。制作時要特別(bie)小心(xin),應使線(xian)芯彎曲部分均勻受力,否則極易損傷(shang)絕緣紙。
58、簡述塑料(liao)電纜的(de)熱收縮密封法。
答:熱(re)縮(suo)(suo)(suo)法適(shi)用于(yu)中、低(di)壓橡(xiang)、塑電(dian)纜接頭和終端頭的密(mi)封,也可適(shi)用于(yu)不滴流和黏性浸(jin)漬絕緣電(dian)纜。采(cai)用交聯聚乙烯型和硅橡(xiang)膠型兩大類遇(yu)熱(re)后能(neng)均(jun)勻收(shou)(shou)縮(suo)(suo)(suo)的熱(re)收(shou)(shou)縮(suo)(suo)(suo)管(guan)。將(jiang)這種管(guan)材套于(yu)預定的粘(zhan)合(he)密(mi)封部(bu)位(wei)(wei),并在(zai)粘(zhan)和部(bu)位(wei)(wei)涂上熱(re)熔(rong)膠,當加熱(re)到一定溫度后,熱(re)縮(suo)(suo)(suo)管(guan)將(jiang)收(shou)(shou)縮(suo)(suo)(suo),同時熱(re)熔(rong)膠熔(rong)化,待自然(ran)冷卻后即形成一道良好的密(mi)封封層(ceng)。
59、用(yong)電動彎(wan)管(guan)機彎(wan)制電纜保(bao)護(hu)管(guan)時應注意什么?
答:(1)彎管機應由了解其性能并熟(shu)悉(xi)操作(zuo)(zuo)知識的人(ren)員操作(zuo)(zuo);
(2)使(shi)用前必須(xu)進行檢查,按鈕、操作把(ba)手、行程開關應(ying)完(wan)好,彎(wan)管機必須(xu)可靠接(jie)地;
(3)選用符合(he)要(yao)求的(de)模(mo)具,確定好所需要(yao)的(de)彎曲半徑;
(4)施工場地周圍(wei),應有充足的活動范圍(wei);
(5)使用時待空(kong)轉正常(chang)后,方可(ke)帶負(fu)荷工作,運行中,嚴禁用手腳(jiao)接觸其轉動(dong)部分;
(6)工作完畢應及(ji)時(shi)停電,釋放(fang)油(you)壓。
60、電(dian)纜(lan)清(qing)冊的(de)內(nei)容及電(dian)纜(lan)編(bian)號的(de)含義是什(shen)么(me)?
答:電纜清(qing)冊是施(shi)放電纜和指導施(shi)工的(de)(de)依據(ju),運行(xing)維護的(de)(de)檔案資料。應(ying)(ying)列入(ru)每根電纜的(de)(de)編(bian)號(hao)、起始點、型號(hao)、規格、長度(du),并(bing)分類統計(ji)出總長度(du),控(kong)纜還應(ying)(ying)列出每根電纜的(de)(de)備用芯。
電纜(lan)編號(hao)是(shi)識(shi)別電纜(lan)的(de)標志,故要求全(quan)廠編號(hao)不重(zhong)復,并且有一定的(de)含義和規律,能表達電纜(lan)的(de)特征(zheng)。
61、電纜目(mu)前采用(yong)的敷設方法(fa)可(ke)分(fen)為(wei)幾類?
答:(1)人(ren)工(gong)敷(fu)設,即采用人(ren)海戰術,在(zai)一人(ren)或多人(ren)協調指揮下(xia),按(an)規定進行敷(fu)設;
(2)機(ji)械化敷設,即采用滾輪、牽引器、輸送機(ji),通(tong)過一同步電源進行控(kong)制(zhi),比較安全;
(3)人工(gong)和機械相結(jie)合,有些(xie)現場由(you)于轉彎較(jiao)多(duo),施工(gong)難(nan)(nan)度大,全用機械較(jiao)困難(nan)(nan),所以采用此法。
62、控制二(er)次(ci)回(hui)路接線應符合哪些要(yao)求?
答:(1)按圖施工接(jie)線正確;
(2)導線的電氣連接(jie)應牢固可靠;
(3)盤柜(ju)內的導線(xian)(xian)不應有接頭,導線(xian)(xian)芯線(xian)(xian)應無損傷;
(4)電纜芯線端部應標(biao)明其(qi)回路編號,編號應正確,字跡清晰且不易(yi)脫(tuo)色;
(5)配(pei)線應整(zheng)齊、清(qing)晰、美觀,導線絕緣應良(liang)好、無(wu)損;
(6)每個(ge)接線(xian)端子的每側接線(xian)宜為(wei)一(yi)根(gen),最多不得超過兩根(gen)。
63、電纜排管有何要(yao)求?
答(da):(1)排管(guan)頂部(bu)至(zhi)地面距離,在(zai)廠房內為0.2m,人(ren)行道下為0.5m,一般地區為0.7m;
(2)在(zai)變更方向及分支處均應裝置(zhi)排管(guan)井(jing)坑,長度超過30mm時也應加設井(jing)坑;
(3)井坑深度不(bu)小于0.8m,人孔直徑(jing)不(bu)小于0.7mm;
(4)排管(guan)應有(you)傾向井坑0.5%~1%的排水(shui)坡(po)度。
64、對于電纜導體(ti)連接點的電阻有(you)何要求?
答(da):要求連(lian)接點(dian)的電阻小而且穩(wen)定,連(lian)接點(dian)的電阻與相同長度、相同截面(mian)的導體之比值,對于(yu)(yu)新安裝(zhuang)的終端頭(tou)(tou)和(he)中間(jian)頭(tou)(tou),應不(bu)大于(yu)(yu)1;對于(yu)(yu)運行中的終端頭(tou)(tou)和(he)中間(jian)頭(tou)(tou)這個(ge)比值不(bu)應大于(yu)(yu)1.2。
65、電纜接頭和中間頭的設計應滿(man)足哪些(xie)要求(qiu)?
答:應滿(man)足(zu)的要求有:
(1)耐(nai)壓強度高,導體連接(jie)好;
(2)機械強度大,介質損(sun)失小;
(3)結構(gou)簡單,密封性強。
66、什么是電纜故障(zhang)?有幾種常(chang)見的類型?
答:電纜故(gu)障(zhang)是指電纜在(zai)預防性試驗時發生絕緣擊穿或在(zai)運行(xing)中,因絕緣擊穿、導線燒(shao)斷等而迫(po)使電纜線路(lu)停電的故(gu)障(zhang)。常見的故(gu)障(zhang)有接(jie)地故(gu)障(zhang)、短路(lu)故(gu)障(zhang)、斷線故(gu)障(zhang)、閃絡性故(gu)障(zhang)和(he)混合型(xing)故(gu)障(zhang)等。
67、如何處理電纜(lan)線路(lu)的單相接地(di)故(gu)障?
答:電(dian)(dian)纜線路單相(xiang)接地故障一般來(lai)說,電(dian)(dian)纜導(dao)體的損傷只是(shi)局(ju)部的,如果屬于機械損傷,而故障點附近的土壤又較干燥時,一般可(ke)進行(xing)局(ju)部修理,加(jia)(jia)添一只假(jia)接頭,即不將電(dian)(dian)纜芯鋸斷,僅將故障點絕緣加(jia)(jia)強后密封即可(ke)。
68、電(dian)力電(dian)纜在敷設前應(ying)進行哪些試驗和檢查(cha)?
答:敷(fu)設前應(ying)檢查電纜(lan)的型(xing)號、規格及長(chang)度是否符(fu)合要求,是否有(you)外力損傷(shang),低壓電纜(lan)用1000V兆歐表遙測絕緣(yuan)電阻,阻值(zhi)一(yi)般不(bu)低于(yu)10MΩ,高(gao)壓電纜(lan)用2500V兆歐表搖測阻值(zhi)一(yi)般不(bu)抵于(yu)400MΩ。
69、主廠(chang)房內(nei)敷設電(dian)纜時(shi)一般應注意(yi)什么?
答:在主廠(chang)房內敷設電(dian)纜時(shi)一般(ban)應注意:
(1)凡(fan)引至集(ji)控室的控制電纜(lan)宜(yi)架空(kong)敷設(she);
(2)6KV電纜宜用(yong)(yong)隧道(dao)或(huo)排管(guan)敷設,地下(xia)水位高處亦可架(jia)空或(huo)用(yong)(yong)排管(guan)敷設;
(3)380V電(dian)纜當(dang)兩端電(dian)纜在零米時宜用隧道、溝或排管(guan),當(dang)一端設備在上、一端在下時,可部分架空敷(fu)設,當(dang)地下水位(wei)較高時,宜架空。
70、電力電纜的內屏蔽層與(yu)外屏蔽層各在什(shen)么部位?采用什(shen)么材料?有何作用?
答:為(wei)(wei)了(le)使絕(jue)緣(yuan)層(ceng)(ceng)和(he)電(dian)纜導體有(you)(you)較好(hao)的(de)(de)接(jie)觸,消除導體表(biao)(biao)面的(de)(de)不光(guang)滑引起的(de)(de)導體表(biao)(biao)面電(dian)場(chang)強度的(de)(de)增(zeng)加,一般(ban)在導體表(biao)(biao)面包有(you)(you)金(jin)屬化(hua)紙(zhi)或(huo)半導體紙(zhi)帶(dai)(dai)的(de)(de)內(nei)屏蔽(bi)層(ceng)(ceng)。為(wei)(wei)了(le)使絕(jue)緣(yuan)層(ceng)(ceng)和(he)金(jin)屬護套有(you)(you)較好(hao)的(de)(de)接(jie)觸,一般(ban)在絕(jue)緣(yuan)層(ceng)(ceng)外(wai)表(biao)(biao)面包有(you)(you)外(wai)層(ceng)(ceng)屏蔽(bi)層(ceng)(ceng)。外(wai)屏層(ceng)(ceng)與內(nei)屏層(ceng)(ceng)的(de)(de)材料相(xiang)同,有(you)(you)時還(huan)外(wai)扎銅帶(dai)(dai)或(huo)編(bian)織銅絲帶(dai)(dai)。
71、簡述(shu)環(huan)氧樹脂(zhi)復合物(wu)的構成及性能。
答:環(huan)氧樹脂復合物由(you)環(huan)氧樹脂加入(ru)硬化(hua)劑、填充劑增(zeng)韌劑和稀釋劑組(zu)成。具有以下性能(neng):
(1)有足(zu)夠的(de)機械強度;
(2)電氣性(xing)能(neng)優良(liang);
(3)電氣性能穩定;
(4)與(yu)有色金屬(shu)有足夠的黏附力;
(5)耐腐蝕性好;
(6)戶(hu)外使用時,耐(nai)雨、耐(nai)光、耐(nai)濕熱。
72、單芯電(dian)纜(lan)護套一端(duan)接地方(fang)式中(zhong)為什么必(bi)須安裝一條(tiao)沿電(dian)纜(lan)平(ping)行敷設的(de)回流線?
答:在(zai)金屬護套一端接地的(de)電(dian)纜線(xian)(xian)(xian)路(lu)中,為確保護套中的(de)感應電(dian)壓不超過允許標準,必(bi)須安裝一條沿電(dian)纜線(xian)(xian)(xian)路(lu)平行敷設(she)的(de)導(dao)(dao)體,且導(dao)(dao)體的(de)兩端接地,這(zhe)種導(dao)(dao)體稱為回(hui)流(liu)線(xian)(xian)(xian)。當發生單相接地故障(zhang)時(shi)(shi),接地短路(lu)電(dian)流(liu)可(ke)以(yi)通過回(hui)流(liu)線(xian)(xian)(xian)流(liu)回(hui)系(xi)統中心(xin)點,由于通過回(hui)流(liu)線(xian)(xian)(xian)的(de)接地電(dian)流(liu)產生的(de)磁(ci)通抵消(xiao)了一部分電(dian)纜導(dao)(dao)線(xian)(xian)(xian)接地電(dian)流(liu)所產生的(de)磁(ci)通,因而可(ke)降低短路(lu)故障(zhang)時(shi)(shi)護套的(de)感應電(dian)壓。
73、電(dian)纜工程(cheng)可(ke)劃分(fen)為幾(ji)個項目(mu)?
答(da):(1)工地運(yun)輸:包括工程材料從(cong)倉庫到(dao)施工點(dian)的裝卸、運(yun)輸和空(kong)車(che)回程。
(2)地方工程:包括路面開(kai)挖、隧、溝道施(shi)工等。
(3)敷設工程:包括敷設、中間(jian)頭(tou)制作、掀蓋板(ban)、埋管、校潮、牽引頭(tou)制作等(deng)。
(4)兩端工(gong)程:包(bao)括支(zhi)、吊(diao)橋架和其基礎的制作安裝,終(zhong)端頭制作,油壓力和信號裝置(zhi)的安裝,名種(zhong)電氣性(xing)能測試等。
(5)塞(sai)止(zhi)(zhi)工程(cheng):包括充油電纜塞(sai)止(zhi)(zhi)頭制作,供油箱、自動排水及(ji)信號(hao)裝(zhuang)置的安裝(zhuang)等。
(6)接(jie)地(di)工程:包括絕緣接(jie)頭、換(huan)位箱、保護器、接(jie)地(di)箱安裝(zhuang)等。
74、電(dian)纜(lan)線路(lu)的驗收應進(jin)行哪些檢查?
答:(1)電(dian)纜規(gui)格應(ying)符合規(gui)定,排列應(ying)整齊(qi)(qi),無(wu)損傷(shang),標牌齊(qi)(qi)全、正(zheng)確(que)、清(qing)晰(xi);
(2)電纜(lan)(lan)的固(gu)定彎曲半徑、有關距離及(ji)單芯電力電纜(lan)(lan)的金屬(shu)護層的接線應(ying)符合要(yao)求;
(3)電(dian)纜(lan)終端、中間(jian)頭不滲漏油(you)(you),安(an)裝牢固,充油(you)(you)電(dian)纜(lan)油(you)(you)壓及表計整(zheng)定(ding)值應符合要(yao)求(qiu);
(4)接地良好;
(5)電纜終(zhong)端相色正確,支(zhi)架等的金屬部(bu)件油漆完整;
(6)電纜溝及隧道內、橋架上應無雜(za)物,蓋板齊全(quan)。
75、電(dian)纜線路正序阻抗測量過程中有什么要求?
答:電(dian)(dian)纜(lan)導體(ti)的交流(liu)電(dian)(dian)阻和電(dian)(dian)纜(lan)三相同感抗的相量和稱為(wei)正序(xu)阻抗。
電(dian)(dian)纜(lan)(lan)線路的(de)正序阻抗一般可在(zai)電(dian)(dian)纜(lan)(lan)盤上(shang)直接測(ce)(ce)量(liang),測(ce)(ce)量(liang)時(shi)(shi)一般使用(yong)較(jiao)低(di)的(de)電(dian)(dian)壓(ya)(ya),因此,需要用(yong)降壓(ya)(ya)變壓(ya)(ya)器進行降壓(ya)(ya),降壓(ya)(ya)器采用(yong)星形接線,容(rong)量(liang)一般為10kVA以上(shang),有(you)較(jiao)廣的(de)電(dian)(dian)壓(ya)(ya)調節范圍,測(ce)(ce)量(liang)時(shi)(shi)交流電(dian)(dian)源應(ying)比較(jiao)穩定,以保證測(ce)(ce)量(liang)時(shi)(shi)電(dian)(dian)流達(da)到(dao)規定的(de)要求,實際電(dian)(dian)壓(ya)(ya)表的(de)讀(du)(du)數值(zhi)必須是電(dian)(dian)纜(lan)(lan)端的(de)電(dian)(dian)壓(ya)(ya),試驗電(dian)(dian)流更好 接近電(dian)(dian)纜(lan)(lan)長期允(yun)許(xu)載流量(liang),測(ce)(ce)讀(du)(du)各(ge)表計的(de)數值(zhi)時(shi)(shi),合上(shang)電(dian)(dian)流后(hou)同時(shi)(shi)讀(du)(du)取三個表的(de)數值(zhi)。
76、根據(ju)《電業生(sheng)產安(an)全規定》,電氣(qi)工作人員必須具備的條(tiao)件是(shi)什么(me)?
答:必須具備下列條(tiao)件:
(1)經醫(yi)生鑒定身體健康,無妨礙工作的病癥;
(2)具備(bei)必要的(de)電氣(qi)知識(shi),按其職務和工作性(xing)質掌握相關的(de)規程、專業技(ji)術及安全操作技(ji)術,并經考試合格;
(3)熟練掌(zhang)握(wo)觸電急救方法。
77、電纜在(zai)運輸裝卸過程(cheng)中應(ying)注意什么?
答:(1)在(zai)運(yun)輸裝卸過程(cheng)中(zhong),不應使電(dian)纜及(ji)電(dian)纜盤受到損傷(shang),嚴禁將電(dian)纜盤直接由車上推(tui)下,電(dian)纜般不應平放運(yun)輸,平放貯存。
(2)運輸或滾(gun)動電(dian)纜盤前,必須保(bao)證電(dian)纜盤牢固(gu),電(dian)纜繞(rao)緊、充(chong)油電(dian)纜至壓力(li)油箱間的油管應(ying)固(gu)定,不得損傷(shang),壓力(li)油箱應(ying)牢固(gu),壓力(li)指示應(ying)符合(he)要求。
78、電纜防火有(you)哪些措施?
答:(1)采用阻(zu)燃電纜;
(2)采用防火電(dian)纜托架;
(3)采用(yong)防火(huo)涂料(liao);
(4)電纜(lan)隧道、夾層出口等處設置防火隔墻、防火擋(dang)板;
(5)架空(kong)電纜(lan)應(ying)避開油管道、防(fang)爆門(men),否則應(ying)有要取局部穿管或(huo)隔熱防(fang)火措施。
79、選擇電力電纜的截面應(ying)從(cong)哪幾個方面考慮(lv)?
答:應考慮如下幾個方面:
(1)電纜長期允許(xu)通過的工作電流;
(2)一旦短路時的熱穩定性(xing);
(3)線(xian)路上的電壓降(jiang)不能(neng)超出允(yun)許(xu)工作范圍(wei)。
80、電(dian)力電(dian)纜和架空線比較有哪些(xie)優點?
答:(1)運(yun)行(xing)可靠,由于安(an)(an)裝在(zai)地下(xia)等隱蔽處,受(shou)外力(li)破壞小,發生故障的機會(hui)較少,供電(dian)安(an)(an)全,不會(hui)給(gei)人身造成(cheng)危(wei)害;
(2)維(wei)護(hu)工作量(liang)小,不需頻(pin)繁的巡檢(jian);
(3)不需架設桿塔(ta);
(4)有助于提高(gao)功率因數。