陳巴爾虎電線電纜常識80問答?沈陽凱鵬電纜廠提供

來(lai)源:常見問題 閱(yue)讀(du):156852 發布時間:2023-03-07

1、常(chang)用(yong)的電線(xian)、電纜按用(yong)途分(fen)有哪些種類?

答:按用途(tu)可(ke)分為裸導線、絕緣電(dian)(dian)(dian)線、耐熱電(dian)(dian)(dian)線、屏蔽電(dian)(dian)(dian)線、電(dian)(dian)(dian)力(li)電(dian)(dian)(dian)纜(lan)、控(kong)制電(dian)(dian)(dian)纜(lan)、通信電(dian)(dian)(dian)纜(lan)、射(she)頻(pin)電(dian)(dian)(dian)纜(lan)等。


2、絕(jue)緣電線有哪幾種(zhong)?

答:常有的(de)絕(jue)(jue)(jue)緣電(dian)線(xian)(xian)有以(yi)下幾種:聚(ju)氯(lv)乙(yi)烯絕(jue)(jue)(jue)緣電(dian)線(xian)(xian)、聚(ju)氯(lv)乙(yi)烯絕(jue)(jue)(jue)緣軟線(xian)(xian)、丁腈聚(ju)氯(lv)乙(yi)烯混合(he)物(wu)絕(jue)(jue)(jue)緣軟線(xian)(xian)、橡皮絕(jue)(jue)(jue)緣電(dian)線(xian)(xian)、農用(yong)地(di)下直埋鋁芯塑(su)料絕(jue)(jue)(jue)緣電(dian)線(xian)(xian)、橡皮絕(jue)(jue)(jue)緣棉紗(sha)紡織軟線(xian)(xian)、聚(ju)氯(lv)乙(yi)烯絕(jue)(jue)(jue)緣尼(ni)龍護套電(dian)線(xian)(xian)、電(dian)力和照(zhao)明(ming)用(yong)聚(ju)氯(lv)乙(yi)烯絕(jue)(jue)(jue)緣軟線(xian)(xian)等。


3、電纜(lan)橋架適合(he)于何種場合(he)?

答:電(dian)纜橋架(jia)適用于一般工(gong)礦企業室內外(wai)架(jia)空敷設(she)電(dian)力電(dian)纜、控(kong)制電(dian)纜,亦可用于電(dian)信、廣播(bo)電(dian)視等部(bu)門在室內外(wai)架(jia)設(she)。


4、電纜(lan)附件有哪(na)些?

答:常用的電(dian)附件有電(dian)纜終端(duan)接線(xian)(xian)盒、電(dian)纜中間接線(xian)(xian)盒、連接管及接線(xian)(xian)端(duan)子、鋼(gang)板接線(xian)(xian)槽、電(dian)纜橋架等(deng)。


5、什么叫電纜中(zhong)間接頭?

答(da):連(lian)接(jie)(jie)電(dian)纜(lan)與(yu)電(dian)纜(lan)的導(dao)體(ti)、絕(jue)緣屏蔽層和(he)保護層,以使電(dian)纜(lan)線(xian)路連(lian)接(jie)(jie)的裝置,稱為電(dian)纜(lan)中(zhong)間接(jie)(jie)頭。


6、什么叫電氣(qi)主接線?

答:電(dian)氣主(zhu)接線是發電(dian)廠、變電(dian)所中(zhong)主(zhu)要(yao)電(dian)氣設備和(he)母線的連接方式(shi),包括(kuo)主(zhu)母線和(he)廠用電(dian)系統按一(yi)定的功能要(yao)求的連接方式(shi)。


7、在選擇電力電纜的(de)截(jie)面時,應遵照哪些規定?

答:電(dian)(dian)(dian)力電(dian)(dian)(dian)纜(lan)的選(xuan)擇應遵照以(yi)下原則:(1)電(dian)(dian)(dian)纜(lan)的額(e)定(ding)電(dian)(dian)(dian)壓要大于(yu)(yu)或等于(yu)(yu)安(an)裝點供(gong)電(dian)(dian)(dian)系統(tong)的額(e)定(ding)電(dian)(dian)(dian)壓;(2)電(dian)(dian)(dian)纜(lan)持續(xu)容許電(dian)(dian)(dian)流應等于(yu)(yu)或大于(yu)(yu)供(gong)電(dian)(dian)(dian)負載的更大 持續(xu)電(dian)(dian)(dian)流;(3)線(xian)芯截面要滿足供(gong)電(dian)(dian)(dian)系統(tong)短路(lu)時的穩定(ding)性的要求;(4)根據電(dian)(dian)(dian)纜(lan)長度驗(yan)算電(dian)(dian)(dian)壓降是否符合要求;(5)線(xian)路(lu)末端(duan)的最(zui)小短路(lu)電(dian)(dian)(dian)流應能使保(bao)護裝置可靠(kao)的動作。


8、交聯聚乙烯電纜(lan)和(he)油紙電纜(lan)比較有(you)哪些優點?

答:(1)易安裝,因為它允許最小彎(wan)曲半(ban)徑小、且重量輕;(2)不受線路落(luo)差*;(3)熱(re)性能好,允許工(gong)作溫度高(gao)(gao)、傳輸(shu)容量大;(4)電纜附件簡(jian)(jian)單,均為干式(shi)結(jie)構(gou);(5)運行維護簡(jian)(jian)單,無漏油問題;(6)價格較低(di);(7)可靠性高(gao)(gao)、故障率(lv)低(di);(8)制(zhi)造工(gong)序少、工(gong)藝簡(jian)(jian)單,經濟效益顯著。


9、固定交流單芯電纜的夾具(ju)有什(shen)么要(yao)求?為(wei)什(shen)么?

答:夾具應無鐵(tie)件(jian)構成閉合磁(ci)路(lu),這(zhe)是(shi)因為當電纜(lan)線芯通過電流時,在(zai)其(qi)周圍產生磁(ci)力線,磁(ci)力線與通過線芯的(de)電流大小成正(zheng)比,若使用鐵(tie)件(jian)等導(dao)磁(ci)材料,根(gen)據電磁(ci)感應可知,將在(zai)鐵(tie)件(jian)中(zhong)產生渦(wo)流使電纜(lan)發熱,甚至燒壞電纜(lan)。所(suo)以(yi)不可使用鐵(tie)件(jian)作單芯交流電纜(lan)的(de)固定夾具。


10、以下(xia)的(de)(de)熱縮電纜頭的(de)(de)附(fu)件的(de)(de)更大 特點和優點是什么?

答:熱縮附(fu)件(jian)的(de)更大 特點是用應力管代替傳(chuan)統的(de)應力錐,它不僅簡化了施工(gong)工(gong)藝,還縮小了接頭的(de)終(zhong)端的(de)尺寸,安裝方便,省時(shi)省工(gong),性能優(you)越,節(jie)約金屬(shu)。熱縮電纜(lan)附(fu)件(jian)集(ji)灌注式和干包式為一(yi)體,集(ji)合了這(zhe)兩種附(fu)件(jian)的(de)優(you)點。


11、電纜敷設前應進行(xing)哪些檢查工作(zuo)?

答:(1)支架應(ying)齊全、油(you)漆(qi)完整。(2)電(dian)纜(lan)型號、電(dian)壓(ya)(ya)、規格符合設計。(3)電(dian)纜(lan)絕(jue)緣良(liang)好,當對(dui)油(you)紙電(dian)纜(lan)的密封(feng)有懷疑(yi)時,應(ying)進行受潮(chao)判斷(duan);直(zhi)埋電(dian)纜(lan)與小底電(dian)纜(lan)應(ying)經直(zhi)流(liu)耐壓(ya)(ya)試(shi)難合格;充(chong)油(you)電(dian)纜(lan)的油(you)樣應(ying)試(shi)驗合格。(4)充(chong)油(you)電(dian)纜(lan)的油(you)壓(ya)(ya)不(bu)宜低于1.47MPa。


11、交聯熱收縮(suo)電(dian)纜(lan)附件有哪些優點?

答:這是一種新型(xing)材料,它與現在(zai)其他(ta)類型(xing)附件(jian)比較(jiao)具有電氣性(xing)能優越、體積小(xiao)、質量(liang)小(xiao)、安裝簡便、材料配(pei)套(tao)等(deng)優點,另外還具有耐氣候(hou)、抗(kang)污穢性(xing)、阻(zu)燃(ran)自熄等(deng)能力。


12、對油紙絕(jue)緣電(dian)力電(dian)纜密封有懷疑時,如何用(yong)較(jiao)簡單的(de)辦(ban)法檢查電(dian)纜絕(jue)緣紙是否(fou)受潮?

答:把電纜(lan)絕緣紙點燃或(huo)放入150℃左右的電纜(lan)油中檢查,無“嘶嘶”聲或(huo)白色泡沫(mo)出現(xian),說明未(wei)受(shou)潮(chao)。


13、電(dian)纜(lan)標志牌應注明什么內容?編寫有何要求?

答(da):標志牌上應注明(ming)電纜(lan)線(xian)路設(she)計(ji)編號(hao)、電纜(lan)型號(hao)、規格及始(shi)點,并(bing)聯使用的電纜(lan)應有(you)順序號(hao)。要(yao)求字跡清(qing)晰、不易脫落(luo)。


14、直埋電纜的方位標志(zhi)應設置在(zai)哪些位置?

答:在電(dian)纜(lan)兩端(duan),電(dian)纜(lan)直(zhi)線段(duan)50~100m處電(dian)纜(lan)接(jie)頭幾電(dian)纜(lan)改變方向的彎角處。


15、制(zhi)作電纜接頭用的黃臘綢帶(dai)、黑玻璃漆帶(dai)、無堿(jian)玻璃絲帶(dai)等,施工前如(ru)何進行排潮處理?

答:(1)恒溫干(gan)燥(zao)(zao)法(fa):將絕(jue)緣(yuan)帶(dai)卷成(cheng)直徑(jing)為25~30mm小卷,放入(ru)110~120℃恒溫干(gan)燥(zao)(zao)箱內(nei)烘4~5h,冷卻干(gan)取出,放入(ru)干(gan)燥(zao)(zao)的(de)密封筒內(nei)。(2)油(you)(you)浸排潮法(fa):將絕(jue)緣(yuan)帶(dai)小卷放入(ru)恒溫在120~130℃的(de)電纜油(you)(you)中,離鍋底保(bao)持(chi)30mm距離,經一定時(shi)間后(hou)油(you)(you)面不再產生泡沫后(hou)取出,裝(zhuang)入(ru)貯有電纜油(you)(you)的(de)桶中,油(you)(you)位應超過所(suo)有裝(zhuang)入(ru)的(de)物體并(bing)將其(qi)密封。


16、電纜外護層(ceng)的作(zuo)用是什么?

答:保(bao)護內護層不受(shou)機械損傷和化學(xue)腐(fu)蝕,增強(qiang)機械強(qiang)度。


17、室外電纜溝應(ying)符合哪(na)些要求?

答:電纜(lan)溝上部應(ying)比地面稍高,加(jia)蓋用混凝土制作的蓋板,電纜(lan)應(ying)平敷在支架上,有良好(hao)的排(pai)水管。


18、電纜內護層的作(zuo)用是什么?

答;使絕(jue)緣層(ceng)不(bu)會與水、空氣或其他(ta)物(wu)體接觸,防止絕(jue)緣受(shou)潮(chao)和絕(jue)緣層(ceng)不(bu)受(shou)機(ji)械傷(shang)害。


19、使(shi)用(yong)鋼絲(si)鉗(qian)時應注意些什么?

答:使用前(qian),一(yi)定要檢查絕緣(yuan)柄的絕緣(yuan)是(shi)否完好(hao)無(wu)損(sun),使用時不可(ke)用鋼絲鉗(qian)剪切超過規格所允許的金屬(shu)線材,并(bing)禁止用鋼絲鉗(qian)代替錘(chui)子(zi)敲打(da)工具,以免損(sun)壞。


20、什么叫絕緣強(qiang)度?

答(da):絕(jue)緣物質在電(dian)(dian)場中,當電(dian)(dian)場強度增(zeng)大到某一極限時就會被擊(ji)穿(chuan)(chuan),這個導致絕(jue)緣擊(ji)穿(chuan)(chuan)的(de)電(dian)(dian)場強度稱(cheng)為絕(jue)緣強度。


22、對電纜導體(ti)連接點的機械(xie)強度有何(he)要求(qiu)?

答:連接(jie)點的(de)(de)(de)機械強度,一般(ban)低于(yu)電(dian)纜導體本身的(de)(de)(de)抗(kang)拉(la)強度,對于(yu)固定敷設的(de)(de)(de)電(dian)力電(dian)纜,其連接(jie)點的(de)(de)(de)抗(kang)拉(la)強度要求不(bu)低于(yu)導體本身抗(kang)拉(la)強度的(de)(de)(de)60%。


23、電(dian)力電(dian)纜的絕(jue)緣層材料應具備哪(na)些主要性能(neng)?

答;應(ying)具(ju)備下(xia)列主要性(xing)(xing)能(neng)(neng):(1)高的(de)擊(ji)穿強(qiang)(qiang)度;(2)低的(de)介(jie)質損耗(hao);(3)相當高的(de)絕(jue)緣電(dian)阻;(4)優(you)良的(de)耐放電(dian)性(xing)(xing)能(neng)(neng);(5)具(ju)有一定(ding)的(de)柔軟(ruan)性(xing)(xing)和機械強(qiang)(qiang)度;(6)絕(jue)緣性(xing)(xing)能(neng)(neng)長期穩定(ding)。


24、機(ji)械(xie)敷設電(dian)纜(lan)時,牽引強(qiang)度(du)有何規定(ding)?

答(da):對(dui)于(yu)銅芯(xin)(xin)電纜,當(dang)(dang)牽引(yin)頭(tou)部(bu)(bu)時,允(yun)許牽引(yin)強(qiang)度為(wei)(wei)(wei)70N/cm;對(dui)于(yu)鋁芯(xin)(xin)電纜,當(dang)(dang)牽引(yin)頭(tou)部(bu)(bu)時,允(yun)許牽引(yin)強(qiang)度為(wei)(wei)(wei)40N/cm;若利用(yong)鋼(gang)絲網(wang)套牽引(yin)時,鉛(qian)護(hu)套電纜允(yun)許強(qiang)度為(wei)(wei)(wei)10N/cm;鉛(qian)護(hu)套電纜為(wei)(wei)(wei)40N/cm。


25、對電纜保護(hu)管有何規定?

答(da):(1)電纜需(xu)要穿(chuan)保(bao)護(hu)管(guan)敷設時(shi),管(guan)子(zi)內徑(jing)不應小于(yu)(yu)電纜外(wai)徑(jing)的(de)1.5倍,混(hun)凝(ning)土(tu)管(guan)、陶土(tu)管(guan)、石棉、水泥管(guan)的(de)內徑(jing)不應小于(yu)(yu)100mm;

(2)電纜管的彎曲(qu)半徑(jing)應符合所穿入電纜彎曲(qu)半徑(jing)的規(gui)定;

(3)每根管子最多(duo)不應(ying)超過(guo)三(san)個(ge)彎頭(tou),直角彎不應(ying)多(duo)于2個(ge)。

26、如(ru)何測量電(dian)纜護(hu)套(tao)的外徑?

答:在護套圓周上(shang)均勻分(fen)布的(de)五點處,測量護套外徑(jing)和其(qi)平均值,其(qi)平均外徑(jing)既為(wei)護套的(de)外徑(jing)。

27、不同截面的銅芯電纜如(ru)何連接?

答:不同截(jie)面(mian)的銅(tong)芯電纜連(lian)接(jie),可(ke)采用開口弱背銅(tong)接(jie)管(guan),以錫焊法連(lian)接(jie),也可(ke)用純銅(tong)棒按不同的截(jie)面(mian)要求連(lian)接(jie)成銅(tong)接(jie)管(guan),以壓接(jie)法連(lian)接(jie)。

28、簡述10KV交(jiao)聯電纜熱縮式制作戶內終端頭的(de)過(guo)程?

答;(1)準備階(jie)段:檢查(cha)熱縮(suo)電纜附件是否(fou)齊(qi)備,型號是否(fou)相配,檢查(cha)并確(que)認(ren)電纜有無潮氣(qi)后,檢查(cha)電纜。

(2)切除(chu)多(duo)余電纜(lan),根據(ju)現場情況(kuang)決定(ding)電纜(lan)長度。

(3)剝除護層(ceng)。

(4)焊(han)接(jie)接(jie)地線,將接(jie)地線焊(han)接(jie)在鋼(gang)帶上。

(5)填充三叉口及繞(rao)包密封膠。

(6)安裝三(san)芯(xin)分支護套(tao),將護套(tao)套(tao)入根(gen)部,從(cong)中部開(kai)始收(shou)縮,先往(wang)根(gen)部,再往(wang)指部。

(7)剝(bo)銅(tong) 帶(dai)和(he)外(wai)半導電層(ceng),剝(bo)切三芯(xin)分支套口20mm以(yi)上的銅(tong)帶(dai),嚴禁(jin)損傷主(zhu)絕(jue)緣,清除干凈半導電層(ceng)。

(8)安裝應力管,管口端部分支套對接(jie)后熱縮。

(9)安裝接線端子。

(10)安裝絕緣(yuan)管。

(11)安(an)裝密封管。

(12)核相后安裝相色管。

29、戶內(nei)、戶外預(yu)制式(shi)終端(duan)安裝(zhuang)步驟有哪些?

答:(1) 將電纜按(an)預定位置就位、固定、清潔表面,參照說明書(shu)剝(bo)除(chu)外(wai)護套,如有特殊需要,外(wai)護套剝(bo)切長度可調整,分別(bie)由銅帶、外(wai)護套鎧裝(zhuang)引出2組地線。

(2) 由(you)外(wai)護套(tao)口(kou)向上(shang)量取需要(yao)尺(chi)寸,切除多(duo)余電(dian)纜(lan),套(tao)入熱(re)縮(suo)三指套(tao)至三叉(cha)口(kou)根部由(you)中間加熱(re)收縮(suo),由(you)指套(tao)上(shang)口(kou)向上(shang)量取規定尺(chi)寸(35kv為350~380mm)。去掉多(duo)余銅帶(保(bao)留20mm),再保(bao)留半導體預定位(wei)置,壓接(jie)出線端子(zi)密(mi)封(feng)。

30、電(dian)線電(dian)纜(lan)的應用主(zhu)要分為三大類 :

(1)、電力(li)系統(tong)

電(dian)(dian)(dian)力(li)(li)系統采(cai)用的電(dian)(dian)(dian)線(xian)電(dian)(dian)(dian)纜(lan)產(chan)品(pin)主要有(you)架空(kong)裸電(dian)(dian)(dian)線(xian)、匯流排(母(mu)線(xian))、電(dian)(dian)(dian)力(li)(li)電(dian)(dian)(dian)纜(lan)(塑(su)料線(xian)纜(lan)、油紙力(li)(li)纜(lan)(基本被塑(su)料電(dian)(dian)(dian)力(li)(li)電(dian)(dian)(dian)纜(lan)代替)、橡套線(xian)纜(lan)、架空(kong)絕緣(yuan)電(dian)(dian)(dian)纜(lan))、分支電(dian)(dian)(dian)纜(lan)(取代部分母(mu)線(xian))、電(dian)(dian)(dian)磁線(xian)以及電(dian)(dian)(dian)力(li)(li)設備(bei)用電(dian)(dian)(dian)氣裝備(bei)電(dian)(dian)(dian)線(xian)電(dian)(dian)(dian)纜(lan)等。

(2)、信息傳(chuan)輸(shu)系統

用(yong)于信息傳輸系統的電線電纜(lan)(lan)主要(yao)有市話電纜(lan)(lan)、電視電纜(lan)(lan)、電子線纜(lan)(lan)、射頻電纜(lan)(lan)、光纖纜(lan)(lan)、數據電纜(lan)(lan)、電磁線、電力(li)通訊或其(qi)他復合(he)電纜(lan)(lan)等。

(3)、機械設備、儀器(qi)儀表系統

此部(bu)分(fen)除架空裸電(dian)(dian)線(xian)外幾(ji)乎(hu)其他(ta)所有(you)產品均有(you)應用,但主要是(shi)電(dian)(dian)力電(dian)(dian)纜、電(dian)(dian)磁線(xian)、數據電(dian)(dian)纜、儀器儀表線(xian)纜等。

31、電線電纜產品主(zhu)要分為五大類(lei):

(1)、裸電(dian)線(xian)(xian)及(ji)裸導(dao)體(ti)制品(pin) 本類產品(pin)的(de)主要(yao)特征(zheng)是:純的(de)導(dao)體(ti)金屬,無絕緣及(ji)護套層,如鋼芯鋁(lv)絞線(xian)(xian)、銅鋁(lv)匯流(liu)排、電(dian)力機車(che)線(xian)(xian)等;加工工藝主要(yao)是壓力加工,如熔煉、壓延(yan)、拉制、絞合(he)(he)/緊壓絞合(he)(he)等;產品(pin)主要(yao)用在城郊、農村、用戶主線(xian)(xian)、開(kai)關柜等。

(2)、電(dian)(dian)力(li)(li)電(dian)(dian)纜(lan)(lan)(lan)本類產(chan)品主(zhu)要(yao)特征是:在導體外擠(繞(rao))包絕(jue)緣(yuan)層,如(ru)架空絕(jue)緣(yuan)電(dian)(dian)纜(lan)(lan)(lan),或(huo)幾芯絞合(對應電(dian)(dian)力(li)(li)系統的相線、零線和地(di)線),如(ru)二芯以上架空絕(jue)緣(yuan)電(dian)(dian)纜(lan)(lan)(lan),或(huo)再增加護(hu)套層,如(ru)塑料/橡套電(dian)(dian)線電(dian)(dian)纜(lan)(lan)(lan)。主(zhu)要(yao)的工(gong)藝(yi)技(ji)術有拉(la)制(zhi)、絞合、絕(jue)緣(yuan)擠出(繞(rao)包)、成纜(lan)(lan)(lan)、鎧裝、護(hu)層擠出等,各種(zhong)產(chan)品的不同工(gong)序組合有一定區別(bie)。

產品主要(yao)用在發、配、輸、變、供電(dian)(dian)線路(lu)中的(de)強(qiang)電(dian)(dian)電(dian)(dian)能(neng)傳輸,通過的(de)電(dian)(dian)流(liu)大(幾(ji)十安至幾(ji)千安)、電(dian)(dian)壓高(220V至500kV及以上(shang))。

(3)、電氣裝備(bei)用(yong)電線(xian)(xian)電纜(lan)(lan)該類產品主(zhu)要特征是:品種規格繁多(duo),應用(yong)范圍廣泛,使(shi)用(yong)電壓在1kV及以下較多(duo),面對(dui)特殊場(chang)合不斷衍生新(xin)的(de)產品,如耐(nai)(nai)火線(xian)(xian)纜(lan)(lan)、阻燃線(xian)(xian)纜(lan)(lan)、低煙無(wu)鹵(lu)/低煙低鹵(lu)線(xian)(xian)纜(lan)(lan)、防(fang)白蟻、防(fang)老鼠線(xian)(xian)纜(lan)(lan)、耐(nai)(nai)油(you)/耐(nai)(nai)寒(han)/耐(nai)(nai)溫(wen)/耐(nai)(nai)磨線(xian)(xian)纜(lan)(lan)、醫用(yong)/農(nong)用(yong)/礦用(yong)線(xian)(xian)纜(lan)(lan)、薄(bo)壁電線(xian)(xian)等(deng)。

(4)、通(tong)訊(xun)電(dian)纜及光纖(簡略介紹)隨著近二十多(duo)年(nian)來,通(tong)訊(xun)行(xing)業的(de)(de)(de)飛速發(fa)展,產(chan)品也有驚人的(de)(de)(de)發(fa)展速度。從(cong)過去的(de)(de)(de)簡單的(de)(de)(de)電(dian)話電(dian)報線纜發(fa)展到(dao)幾(ji)千對的(de)(de)(de)話纜、同(tong)軸纜、光纜、數據電(dian)纜,甚至組合(he)通(tong)訊(xun)纜等。

該類產品結(jie)構尺寸通常較(jiao)小而均勻,制(zhi)造精(jing)度(du)要(yao)求高。

(5)、電磁線(xian)(繞組線(xian))主要用于各(ge)種電機(ji)、儀(yi)器儀(yi)表(biao)等。

電線電纜(lan)的衍生/新產品

電線(xian)電纜的(de)衍生/新產品(pin)(pin)主要(yao)(yao)是因(yin)應用場合(he)、應用要(yao)(yao)求(qiu)不(bu)同及裝備(bei)的(de)方便性和降低裝備(bei)成本等(deng)的(de)要(yao)(yao)求(qiu),而(er)采用新材料、特(te)殊材料、或改變產品(pin)(pin)結(jie)構、或提高工藝要(yao)(yao)求(qiu)、或將(jiang)不(bu)同品(pin)(pin)種的(de)產品(pin)(pin)進行(xing)組(zu)合(he)而(er)產生。

采用(yong)不同材料如阻燃(ran)線纜、低(di)煙(yan)無鹵/低(di)煙(yan)低(di)鹵線纜、防(fang)白蟻、防(fang)老鼠線纜、耐(nai)油/耐(nai)寒/耐(nai)溫線纜等;

改(gai)變產品(pin)結(jie)構如:耐火電纜等;

提高工藝要(yao)求如:醫用線纜等;

組合產品如:OPGW等;

方便安裝和(he)降低(di)裝備成(cheng)本如:預制分支電纜等(deng)。

32、母線裝(zhuang)置施工(gong)完,應(ying)進行哪些檢查?

答:應進行下列(lie)檢查:

(1)金(jin)屬構件的加工(gong)、配制、焊(han)接螺(luo)接應符合規定(ding);

(2)各部(bu)螺栓、墊圈、開口銷等(deng)零部(bu)件(jian)應齊全可靠;

(3)母線配制(zhi)及安裝架(jia)應符合(he)規定,相間(jian)及對地電氣距離符合(he)要求;

(4)瓷(ci)件(jian)、鐵件(jian)及膠合處應完整,充油(you)套管(guan)應無滲(shen)油(you),油(you)位正常;

(5)油漆完整(zheng),相(xiang)色正確,接地良好。

33、在(zai)35kv及以下電力電纜接頭中,改善其(qi)護套(tao)斷(duan)開(kai)處電場分(fen)布的方法有(you)幾種(請列出五(wu)種),并簡述其(qi)方法。

答(da):(1)脹喇(la)(la)叭(ba)口:在鉛包(bao)割斷(duan)處把鉛包(bao)邊(bian)緣(yuan)撬起(qi),成喇(la)(la)叭(ba)狀(zhuang),其邊(bian)緣(yuan)應光滑、圓整、對稱。

(2)預留統(tong)包絕緣(yuan):在鉛(qian)包切口至(zhi)電(dian)纜芯線分開點之間留有一段統(tong)包絕緣(yuan)紙。

(3)切除(chu)半導電(dian)紙(zhi)(zhi):將半導電(dian)紙(zhi)(zhi)切除(chu)到喇(la)叭口以(yi)下。

(4)包(bao)繞應力錐:用絕緣包(bao)帶和導電金屬材料包(bao)成錐形,人為地將屏蔽(bi)層擴大,以改善電場分布。

(5)等電位法:對于干包型(xing)或交聯(lian)聚乙(yi)烯電纜頭,在各線芯概況絕緣表(biao)面上包一段(duan)金(jin)屬帶,并將(jiang)其連接在一起(qi)。

(6)裝設應(ying)力控制管(guan):對于(yu)35kv及發下熱(re)縮(suo)(suo)管(guan)電纜頭(tou),首先從(cong)線(xian)(xian)芯銅屏蔽(bi)層末端(duan)方(fang)向經半(ban)導體帶至線(xian)(xian)芯絕緣概況(kuang)包繞2層半(ban)導體帶,然后(hou)將相應(ying)規格折應(ying)力管(guan),套在銅屏蔽(bi)的末端(duan)處(chu),熱(re)縮(suo)(suo)成形(xing)。

34、電纜支架的加工應符合哪些(xie)要(yao)求?

答:(1)鋼材應平(ping)直(zhi),無(wu)(wu)明(ming)顯扭(niu)曲,下料誤差應在(zai)5mm范圍(wei)內,切(qie)口應無(wu)(wu)卷邊,毛剌(la);

(2)支架應(ying)焊接牢固,無顯(xian)蓍變形,各橫撐(cheng)間的垂直凈距(ju)與設計偏差(cha)不(bu)應(ying)大于5mm;

(3)金屬支(zhi)架必須(xu)進行防腐(fu)處(chu)理,位(wei)于濕熱、鹽、霧以(yi)及有化學腐(fu)蝕地區時,應(ying)根據設(she)計作特殊(shu)的防腐(fu)處(chu)理。

35、列舉出你熟悉(xi)的電纜架。

答:拼焊式(shi)E型架(jia)、裝配(pei)式(shi)E型架(jia)、橋式(shi)電(dian)纜架(jia)、電(dian)纜托架(jia)、掛鉤式(shi)支(zhi)架(jia)、單根電(dian)纜支(zhi)架(jia)等。

36、敷(fu)設電纜應(ying)滿足哪些要(yao)求?

答:應滿(man)足(zu)以下要(yao)求:

(1)安全(quan)運行方面,盡可能避免各種外來損壞,提高電纜線路的供電可靠性;

(2)經濟(ji)方(fang)面,從投資最(zui)省的方(fang)面考(kao)慮;

(3)施(shi)工方面(mian),電纜線路的(de)路徑必(bi)須便于旋(xuan)工和投運后(hou)的(de)維修。

37、制作(zuo)電纜終端頭(tou)或中間接頭(tou)的絕緣材料(liao)有哪些(xie)?

答(da):有絕緣膠(jiao)、絕緣帶、絕緣管(guan)、絕緣手(shou)套、絕緣樹脂(zhi)等(deng)。

38、簡述電纜頭制(zhi)作(zuo)的(de)(de)一(yi)般操作(zuo)程序。答:(1)制(zhi)作(zuo)前的(de)(de)準(zhun)備:包括○1閱(yue)讀安(an)裝說明書;○2察(cha)看現場;○3備料;○4電纜試潮;○5制(zhi)作(zuo)前測試等(deng)。

(2)接頭(tou)的制(zhi)作過程:包括(kuo)○1割斷多余電纜(lan);○2電纜(lan)保護(hu)層的剝(bo)切;○3導體連接;○4包繞絕緣(或收縮管材);○5安(an)裝接頭(tou)外殼;○6灌注絕緣劑(ji);○7進行(xing)密封(feng)處理等(deng)。

(3)制作后(hou)電氣(qi)測試。

39、電(dian)纜保(bao)護(hu)管的加工(gong)應符(fu)合哪(na)些(xie)要求?

答:(1)管口應*剌和(he)尖(jian)銳(rui)楞角,管口宜做成(cheng)喇叭形。

(2)電(dian)(dian)纜管在彎制后,不(bu)(bu)應有裂縫和顯著的凹癟現象,其彎扁程度(du)不(bu)(bu)宜大于管子外徑(jing)10%;電(dian)(dian)纜管的彎曲(qu)半徑(jing)不(bu)(bu)應小于所穿入電(dian)(dian)纜的最小允(yun)許彎曲(qu)半徑(jing)。

(3)金屬管(guan)應(ying)在外表(biao)涂防腐漆或瀝表(biao),鍍鋅(xin)管(guan)鋅(xin)層(ceng)剝落處也應(ying)涂以防腐漆。

40、電(dian)纜的排列符合(he)哪些(xie)要(yao)求?答:(1)電(dian)力電(dian)纜和控(kong)纜不(bu)應配(pei)置在(zai)同一層支架上。

(2)高(gao)、低(di)壓電(dian)(dian)(dian)纜(lan)(lan),強(qiang)、弱電(dian)(dian)(dian)控(kong)纜(lan)(lan)應按(an)須序(xu)分層(ceng)配置,一般情(qing)況(kuang)宜由上(shang)(shang)而下,但在含(han)有35kv以上(shang)(shang)高(gao)壓電(dian)(dian)(dian)纜(lan)(lan)引(yin)入柜盤(pan)時,為滿足彎(wan)曲半徑,可由下面(mian)上(shang)(shang)配置。

41、電纜(lan)溝(gou)內敷(fu)設電纜(lan)的方法是什么?

答:在電(dian)纜溝內敷(fu)設(she)電(dian)纜的方法與直埋電(dian)纜的敷(fu)設(she)方法相仿,一(yi)般(ban)可將滑輪放(fang)在溝內,施放(fang)完畢,將電(dian)纜放(fang)于(yu)溝底(di)或(huo)支(zhi)架上(shang),并在電(dian)纜上(shang)綁扎電(dian)纜標牌。

42、電(dian)纜敷(fu)設的常用設備有哪些?

答:(1)空氣壓縮機,主要(yao)用來破壞路面,為以后(hou)敷設(she)電纜作準備;

(2)電(dian)(dian)(dian)動卷揚(yang)機或電(dian)(dian)(dian)纜(lan)牽引機,主(zhu)要用(yong)來拖電(dian)(dian)(dian)纜(lan);

(3)電纜輸送機,配合牽引機使(shi)用來(lai)克服巨(ju)大的摩擦力(li),減輕對電纜的損壞;

(4)電纜盤放線支架;

(5)滾輪裝置;

(6)防捻 ,減鋼(gang)絲繩出現的扭曲;

(7)電(dian)纜盤制動裝置;

(8)張(zhang)力(li)計。

43、電(dian)(dian)(dian)纜溝中支架安裝距離的要(yao)求如何?答:電(dian)(dian)(dian)纜固定(ding)于(yu)電(dian)(dian)(dian)纜溝和隧道(dao)的墻上,水(shui)平裝置時(shi),當電(dian)(dian)(dian)纜外(wai)徑(jing)等于(yu)或小于(yu)50mm時(shi)應每隔1m加一支撐(cheng);外(wai)徑(jing)大(da)于(yu)50mm的電(dian)(dian)(dian)纜每隔0.6m加一支撐(cheng);排(pai)成三角形的單電(dian)(dian)(dian)纜,每隔1m應用綁帶扎牢,垂(chui)直裝置時(shi),每隔1~1.5m加以固定(ding)。

44、如何處(chu)理電力(li)電纜與控制電纜在(zai)同(tong)一托架的安裝(zhuang)?

答:電(dian)(dian)(dian)力電(dian)(dian)(dian)纜(lan)(lan)與(yu)控制(zhi)電(dian)(dian)(dian)纜(lan)(lan)一般不應敷(fu)設(she)在同(tong)一托(tuo)架內(nei),當電(dian)(dian)(dian)纜(lan)(lan)較少而將控纜(lan)(lan)與(yu)電(dian)(dian)(dian)力電(dian)(dian)(dian)纜(lan)(lan)敷(fu)設(she)在同(tong)一托(tuo)架內(nei)時(shi),應用(yong)隔板隔開(kai)。

45、電纜隧道(dao)內如何裝設接地線?

答:隧(sui)道和(he)(he)溝的全(quan)長應(ying)裝設(she)連(lian)續的接(jie)(jie)(jie)地(di)(di)線(xian),接(jie)(jie)(jie)地(di)(di)線(xian)應(ying)和(he)(he)所(suo)有的支架相連(lian),兩頭和(he)(he)接(jie)(jie)(jie)地(di)(di)極連(lian)通。接(jie)(jie)(jie)地(di)(di)線(xian)的規格應(ying)符合設(she)計(ji)要求。電纜鉛包和(he)(he)鎧裝除了有絕緣要求外,應(ying)全(quan)部相互連(lian)接(jie)(jie)(jie)并和(he)(he)接(jie)(jie)(jie)地(di)(di)線(xian)相連(lian),電纜架和(he)(he)接(jie)(jie)(jie)地(di)(di)線(xian)均應(ying)涂防銹漆或鍍鋅。

46、對(dui)于電纜孔洞的防(fang)火封(feng)堵有何要求(qiu)?

答:對于較大的電纜(lan)(lan)貫(guan)穿(chuan)孔洞,如(ru)電纜(lan)(lan)貫(guan)穿(chuan)樓板處等,采(cai)用防火(huo)堵(du)料封(feng)堵(du)時(shi),應根據(ju)實際情況,先在電纜(lan)(lan)表面涂(tu)四至(zhi)六層防火(huo)涂(tu)料,長(chang)度自孔洞以下1.5m左右,再(zai)用耐火(huo)材料加工(gong)成具有一(yi)定強度的板托防火(huo)堵(du)料,保證封(feng)堵(du)后(hou)牢固并便于更換電纜(lan)(lan)時(shi)拆(chai)裝,封(feng)堵(du)密(mi)實無孔隙(xi)以有效地堵(du)煙堵(du)火(huo)。

47、噴燈點火(huo)前應(ying)注意哪些檢查(cha)?

答:應進(jin)行下列各項(xiang)檢查:

(1)打(da)氣(qi)筒是(shi)否(fou)漏(lou)(lou)油(you)或滲油(you),油(you)桶(tong)及噴嘴處是(shi)否(fou)漏(lou)(lou)油(you)、漏(lou)(lou)氣(qi);

(2)油(you)桶內的(de)油(you)量是(shi)否超過油(you)桶容(rong)量的(de)3/4,加油(you)的(de)螺絲塞是(shi)否擰緊(jin)。

48、使用噴燈應注意哪些(xie)事項?

答:(1)噴燈更大 注油量為油筒(tong)容積的3/4;

(2)開始打(da)氣壓(ya)力不要太大(da),點燃后火(huo)焰由黃變藍即可使用;

(3)周圍不得有易燃物,空氣(qi)要(yao)流通;

(4)停(ting)用(yong)時先關閉調節(jie)開關,火(huo)熄(xi)后,慢慢旋松油(you)孔蓋放氣,空(kong)氣放完(wan)后,要要旋松調節(jie)開關,完(wan)全冷卻后再旋松孔蓋;

(5)煤油噴燈與汽油噴燈要分開使(shi)用。

49、手動油壓鉗有何(he)用途?如何(he)操作?

答:兩(liang)根導線(xian)的(de)連接(jie)(jie)通常是將兩(liang)導線(xian)端穿(chuan)入(ru)相(xiang)同材(cai)料制成的(de)壓(ya)管(guan)中,用壓(ya)接(jie)(jie)鉗擠(ji)壓(ya)數個(ge)坑,使導線(xian)連接(jie)(jie)在一起(qi),壓(ya)接(jie)(jie)時,手(shou)柄(bing)向上(shang)抬起(qi)時,柱塞(sai)向外移(yi)動,進(jin)油(you)(you)(you)閥下腔(qiang)產生真(zhen)空,油(you)(you)(you)箱內的(de)油(you)(you)(you)進(jin)入(ru)柱塞(sai)腔(qiang)。手(shou)柄(bing)下壓(ya)時,柱塞(sai)向內移(yi)動,油(you)(you)(you)受(shou)壓(ya)后,使進(jin)油(you)(you)(you)閥關(guan)閉,打開出(chu)油(you)(you)(you)閥,使油(you)(you)(you)壓(ya)進(jin)入(ru)液壓(ya)缸,推動活塞(sai)和陽(yang)模,陽(yang)、陰模之間放有壓(ya)接(jie)(jie)管(guan),當壓(ya)接(jie)(jie)被擠(ji)壓(ya)的(de)坑深到一定值(zhi)時,開啟回油(you)(you)(you)閥,活塞(sai)自動返回,壓(ya)完一個(ge)坑后,移(yi)動壓(ya)鉗,再壓(ya)下一個(ge)。

50、常用低壓電力電纜(lan)按絕緣和(he)保護(hu)層的不同,主要可(ke)分(fen)為哪幾類(lei)?

答:(1)油浸紙(zhi)絕緣鉛包(bao)(或鋁包(bao))電力電纜(lan);

(2)不滴流(liu)油浸(jin)紙(zhi)絕緣電力電纜;

(3)聚(ju)氯乙烯(xi)絕緣聚(ju)氯乙烯(xi)護套電(dian)力(li)電(dian)纜;

(4)交聯聚氯乙(yi)烯絕緣聚乙(yi)烯護套電(dian)力(li)電(dian)纜;

(5)交(jiao)聯聚氯乙烯絕緣聚氯乙烯護(hu)套電力電纜(lan);

(6)橡皮絕(jue)緣電力電纜。

51、常用(yong)絕緣材料(liao)的類別哪些?舉例說明(ming)?

答:(1)無機絕緣(yuan)材(cai)料:有云母、石棉、大(da)理石、瓷(ci)器(qi)、玻(bo)璃等;

(2)有機絕緣材料:有樹脂、橡(xiang)膠、紙、麻、棉(mian)紗等;

(3)混合絕緣材(cai)料(liao):用(yong)以上絕緣材(cai)料(liao)加工而成型的名種絕緣材(cai)料(liao)。

52、在哪種情況下采用排管(guan)敷設(she)?有什(shen)么優點?

答:排管(guan)敷設一般用在與其他建筑物、公路或鐵路相交叉(cha)的(de)地方,有時也在建筑物密(mi)集區內采(cai)用。主要優點是占地少,能承受大的(de)荷重,電(dian)纜(lan)相互間互不(bu)影響(xiang),比較安全。

53、何謂(wei)電纜長期允(yun)許載(zai)流量?

答:電(dian)(dian)(dian)(dian)纜長期允許載流(liu)量是指(zhi)在電(dian)(dian)(dian)(dian)纜內通過(guo)規定電(dian)(dian)(dian)(dian)流(liu)時,在熱穩定后,電(dian)(dian)(dian)(dian)纜導(dao)體達(da)到(dao)長期允許工作溫(wen)度(du)時的電(dian)(dian)(dian)(dian)流(liu)數值(zhi)。

54、決定電纜長(chang)期允許載流量的因素有哪些?

答(da):有(you)以下三個因素決定:

(1)電纜(lan)的長期容許工作溫度;

(2)電纜本身(shen)的散熱性能;

(3)電纜(lan)裝置情(qing)況及周(zhou)圍環境的散熱(re)條件。

55、電纜的敷(fu)設(she)方式有幾種?

答:有以下幾(ji)種:

(1)直(zhi)埋在(zai)地下;

(2)安裝在(zai)電纜(lan)溝(gou)內;

(3)安裝在(zai)地下隧道內;

(4)安裝(zhuang)在建筑(zhu)物(wu)內部墻上或(huo)天(tian)棚上;

(5)安(an)裝在橋架上;

(6)敷(fu)設在排管內;

(7)敷(fu)設(she)在水底。

56、如何進行電纜管的連接工作?

答:電(dian)纜管(guan)連接時,必(bi)須用扣和(he)管(guan)接頭連接,如采用焊(han)接時,不能直接對焊(han),連接處要套上一段(duan)粗管(guan)再進(jin)行焊(han)接,以免焊(han)渣掉入(ru)管(guan)內。

57、制作(zuo)電纜頭時,對上(shang)下扳彎(wan)電纜芯線有何要(yao)求?

答:扳彎線芯(xin)(xin)時(shi),不得(de)損傷紙絕(jue)(jue)緣,芯(xin)(xin)線的(de)彎曲半徑(jing)不得(de)小于(yu)電(dian)纜線芯(xin)(xin)的(de)10倍(bei)。制作時(shi)要特(te)別(bie)小心,應(ying)使線芯(xin)(xin)彎曲部分(fen)均勻(yun)受力(li),否則極易損傷絕(jue)(jue)緣紙。

58、簡(jian)述塑料電纜的熱(re)收縮密封法。

答:熱(re)縮法適用于(yu)(yu)中、低(di)壓橡(xiang)、塑電(dian)纜接頭(tou)和(he)(he)終端頭(tou)的密(mi)封(feng),也可適用于(yu)(yu)不滴流和(he)(he)黏性浸漬絕緣電(dian)纜。采用交聯聚乙烯型和(he)(he)硅橡(xiang)膠型兩大類遇熱(re)后能均勻(yun)收縮的熱(re)收縮管。將(jiang)這(zhe)種管材套于(yu)(yu)預定的粘合(he)密(mi)封(feng)部位(wei),并在粘和(he)(he)部位(wei)涂(tu)上熱(re)熔(rong)膠,當加熱(re)到一定溫度后,熱(re)縮管將(jiang)收縮,同時熱(re)熔(rong)膠熔(rong)化,待自然冷卻(que)后即形成一道良好的密(mi)封(feng)封(feng)層。

59、用電動彎管機彎制電纜保護管時應注意什么?

答(da):(1)彎管機應由了(le)解其性能(neng)并熟悉操作知識的人員操作;

(2)使用(yong)前必(bi)須進行檢查,按鈕(niu)、操作把(ba)手(shou)、行程開關應完好,彎管機(ji)必(bi)須可靠(kao)接(jie)地;

(3)選用符合(he)要求(qiu)的模(mo)具(ju),確定好(hao)所需要的彎曲半徑;

(4)施工場地周圍(wei),應有充(chong)足的活(huo)動(dong)范圍(wei);

(5)使用(yong)(yong)時待空轉(zhuan)正常后,方可(ke)帶負(fu)荷(he)工作(zuo),運行中,嚴(yan)禁用(yong)(yong)手腳接觸其轉(zhuan)動部分;

(6)工作完畢應及時停電,釋放油壓(ya)。

60、電(dian)纜清冊的(de)內容及電(dian)纜編號(hao)的(de)含義是什么?

答:電纜(lan)(lan)清冊是施放電纜(lan)(lan)和指導施工(gong)的(de)(de)依據,運行維(wei)護的(de)(de)檔案(an)資料。應(ying)列入每根電纜(lan)(lan)的(de)(de)編號、起(qi)始點、型號、規格(ge)、長度(du),并分類統計出總長度(du),控纜(lan)(lan)還應(ying)列出每根電纜(lan)(lan)的(de)(de)備(bei)用芯。

電纜(lan)編號是(shi)識(shi)別電纜(lan)的(de)標志,故要求全廠(chang)編號不重復,并且有一定(ding)的(de)含義和規律,能表達電纜(lan)的(de)特征。

61、電纜目(mu)前采(cai)用的敷設方法(fa)可分為幾類?

答:(1)人工敷設,即采用人海戰(zhan)術,在一人或多人協調指(zhi)揮(hui)下,按規定進行敷設;

(2)機械(xie)化(hua)敷設,即采(cai)用(yong)滾輪、牽(qian)引器(qi)、輸送機,通過(guo)一同步電源進行控制,比較安全;

(3)人(ren)工(gong)和(he)機(ji)械相(xiang)結合,有些現場由于轉彎較多,施工(gong)難(nan)度大,全用機(ji)械較困(kun)難(nan),所以采用此法。

62、控(kong)制二次回路接線(xian)應符合(he)哪(na)些要(yao)求?

答:(1)按圖施工(gong)接線(xian)正(zheng)確;

(2)導線的電氣連接應(ying)牢固可(ke)靠;

(3)盤(pan)柜內(nei)的(de)導(dao)線(xian)(xian)不(bu)應有接頭,導(dao)線(xian)(xian)芯線(xian)(xian)應無損傷(shang);

(4)電纜(lan)芯(xin)線端部應標明其回路編(bian)號(hao),編(bian)號(hao)應正(zheng)確,字跡清晰且不易脫(tuo)色;

(5)配線應整齊、清晰、美觀,導線絕(jue)緣應良好、無損;

(6)每個接線端(duan)子的每側(ce)接線宜為一根,最(zui)多不得(de)超(chao)過兩根。

63、電纜排管有何要求?

答:(1)排管頂部至地面距離,在廠房(fang)內為0.2m,人行道下為0.5m,一般地區(qu)為0.7m;

(2)在(zai)變更方向及分支處(chu)均(jun)應(ying)裝置(zhi)排管井坑(keng),長度(du)超過30mm時也應(ying)加設(she)井坑(keng);

(3)井坑深度不(bu)小于0.8m,人孔(kong)直徑不(bu)小于0.7mm;

(4)排管應有傾向(xiang)井坑0.5%~1%的排水(shui)坡度。

64、對于(yu)電(dian)纜導(dao)體連接點的電(dian)阻有何要求(qiu)?

答:要(yao)求(qiu)連(lian)接點的電阻(zu)小而(er)且穩(wen)定,連(lian)接點的電阻(zu)與相同(tong)長度、相同(tong)截面的導體之比值(zhi),對(dui)(dui)于(yu)新安(an)裝的終(zhong)端(duan)頭(tou)和中(zhong)間頭(tou),應不(bu)大于(yu)1;對(dui)(dui)于(yu)運行中(zhong)的終(zhong)端(duan)頭(tou)和中(zhong)間頭(tou)這個比值(zhi)不(bu)應大于(yu)1.2。

65、電纜接頭和(he)中間頭的設計應(ying)滿足哪些要求?

答:應滿足的要(yao)求(qiu)有:

(1)耐壓(ya)強度高,導(dao)體(ti)連接好(hao);

(2)機械(xie)強度大,介質損失小;

(3)結(jie)構簡單,密封性強。

66、什么是電纜故障?有(you)幾種常見的(de)類型?

答:電(dian)纜故(gu)(gu)(gu)(gu)(gu)障(zhang)(zhang)是指電(dian)纜在預防性(xing)試驗時發生絕緣擊穿(chuan)或(huo)在運行中,因(yin)絕緣擊穿(chuan)、導線燒(shao)斷等而迫使電(dian)纜線路停電(dian)的(de)故(gu)(gu)(gu)(gu)(gu)障(zhang)(zhang)。常(chang)見的(de)故(gu)(gu)(gu)(gu)(gu)障(zhang)(zhang)有接地故(gu)(gu)(gu)(gu)(gu)障(zhang)(zhang)、短路故(gu)(gu)(gu)(gu)(gu)障(zhang)(zhang)、斷線故(gu)(gu)(gu)(gu)(gu)障(zhang)(zhang)、閃絡性(xing)故(gu)(gu)(gu)(gu)(gu)障(zhang)(zhang)和混合型(xing)故(gu)(gu)(gu)(gu)(gu)障(zhang)(zhang)等。

67、如(ru)何處(chu)理電纜線路(lu)的單相接地故障?

答:電(dian)纜(lan)(lan)線路單(dan)相接地故障(zhang)一(yi)般(ban)來(lai)說,電(dian)纜(lan)(lan)導體(ti)的損傷只是(shi)局部的,如(ru)果(guo)屬于機械(xie)損傷,而故障(zhang)點(dian)附(fu)近的土壤(rang)又較(jiao)干燥時(shi),一(yi)般(ban)可(ke)進行局部修理,加添一(yi)只假接頭,即(ji)不將電(dian)纜(lan)(lan)芯鋸斷,僅將故障(zhang)點(dian)絕(jue)緣加強(qiang)后(hou)密封即(ji)可(ke)。

68、電(dian)力電(dian)纜在敷設前應進(jin)行哪些試驗和檢查?

答(da):敷設(she)前應檢查(cha)電纜(lan)的型號、規(gui)格及長度(du)是否符合要求,是否有外力(li)損傷,低壓(ya)電纜(lan)用(yong)1000V兆(zhao)歐表(biao)(biao)遙測絕緣電阻(zu),阻(zu)值(zhi)一般不低于10MΩ,高壓(ya)電纜(lan)用(yong)2500V兆(zhao)歐表(biao)(biao)搖測阻(zu)值(zhi)一般不抵(di)于400MΩ。

69、主廠(chang)房內敷設(she)電纜時一般應注意什么?

答:在(zai)主廠房(fang)內敷(fu)設電(dian)纜時(shi)一般(ban)應注(zhu)意:

(1)凡(fan)引至(zhi)集控(kong)室的控(kong)制電纜(lan)宜架空敷設;

(2)6KV電纜宜用隧道(dao)或排管敷(fu)設(she),地下水位高(gao)處(chu)亦可架空或用排管敷(fu)設(she);

(3)380V電纜當(dang)兩端(duan)電纜在零米(mi)時(shi)宜(yi)用隧道、溝(gou)或排管,當(dang)一端(duan)設備在上、一端(duan)在下時(shi),可(ke)部分架空敷設,當(dang)地下水位(wei)較高時(shi),宜(yi)架空。

70、電力電纜的內(nei)屏(ping)蔽(bi)層(ceng)與外屏(ping)蔽(bi)層(ceng)各(ge)在什么(me)(me)部位?采(cai)用什么(me)(me)材料?有何作用?

答:為了(le)使(shi)絕(jue)緣層(ceng)和電(dian)纜(lan)導(dao)體(ti)(ti)有較好的(de)接觸,消(xiao)除導(dao)體(ti)(ti)表(biao)面(mian)的(de)不(bu)光滑(hua)引(yin)起的(de)導(dao)體(ti)(ti)表(biao)面(mian)電(dian)場強度(du)的(de)增加,一(yi)般在導(dao)體(ti)(ti)表(biao)面(mian)包有金屬化紙(zhi)或(huo)半導(dao)體(ti)(ti)紙(zhi)帶的(de)內(nei)屏(ping)蔽層(ceng)。為了(le)使(shi)絕(jue)緣層(ceng)和金屬護(hu)套有較好的(de)接觸,一(yi)般在絕(jue)緣層(ceng)外(wai)(wai)(wai)表(biao)面(mian)包有外(wai)(wai)(wai)層(ceng)屏(ping)蔽層(ceng)。外(wai)(wai)(wai)屏(ping)層(ceng)與(yu)內(nei)屏(ping)層(ceng)的(de)材料相同,有時還(huan)外(wai)(wai)(wai)扎銅(tong)帶或(huo)編織(zhi)銅(tong)絲帶。

71、簡述環氧樹脂復合物的構成及性能。

答:環氧(yang)(yang)樹脂(zhi)復合物由環氧(yang)(yang)樹脂(zhi)加(jia)入硬化劑(ji)(ji)、填充劑(ji)(ji)增韌劑(ji)(ji)和(he)稀釋劑(ji)(ji)組成(cheng)。具有以下(xia)性能:

(1)有足夠的機械強度;

(2)電氣性能優良;

(3)電氣性能穩定;

(4)與有色金屬有足(zu)夠的黏附力;

(5)耐腐蝕(shi)性好(hao);

(6)戶外使用時,耐雨、耐光、耐濕熱。

72、單芯(xin)電纜護套一端接地方式中為什么(me)必(bi)須安裝一條沿(yan)電纜平行敷設(she)的回流線?

答:在金屬護套(tao)一(yi)(yi)端接地(di)的(de)(de)電(dian)纜(lan)線(xian)(xian)(xian)路(lu)(lu)中,為確保護套(tao)中的(de)(de)感(gan)應電(dian)壓不超過允許標準,必(bi)須安(an)裝一(yi)(yi)條沿(yan)電(dian)纜(lan)線(xian)(xian)(xian)路(lu)(lu)平行敷(fu)設的(de)(de)導體(ti)(ti),且導體(ti)(ti)的(de)(de)兩端接地(di),這(zhe)種導體(ti)(ti)稱為回流(liu)(liu)線(xian)(xian)(xian)。當發(fa)生單相接地(di)故障時,接地(di)短路(lu)(lu)電(dian)流(liu)(liu)可以通(tong)過回流(liu)(liu)線(xian)(xian)(xian)流(liu)(liu)回系(xi)統中心(xin)點,由于(yu)通(tong)過回流(liu)(liu)線(xian)(xian)(xian)的(de)(de)接地(di)電(dian)流(liu)(liu)產(chan)生的(de)(de)磁(ci)通(tong)抵(di)消了一(yi)(yi)部分電(dian)纜(lan)導線(xian)(xian)(xian)接地(di)電(dian)流(liu)(liu)所產(chan)生的(de)(de)磁(ci)通(tong),因而(er)可降低(di)短路(lu)(lu)故障時護套(tao)的(de)(de)感(gan)應電(dian)壓。

73、電纜工程可劃分為幾個(ge)項目?

答:(1)工地運(yun)輸:包括工程材(cai)料從倉庫到施(shi)工點的裝卸、運(yun)輸和空車回程。

(2)地方工程(cheng):包括路面開挖、隧、溝道(dao)施工等。

(3)敷設工程:包(bao)括敷設、中間頭制作、掀蓋板、埋管、校(xiao)潮(chao)、牽引頭制作等。

(4)兩端(duan)工程:包括支、吊橋架和其(qi)基礎(chu)的制(zhi)作安裝,終端(duan)頭制(zhi)作,油壓力和信號裝置的安裝,名種電氣(qi)性(xing)能測試(shi)等。

(5)塞止(zhi)工程:包(bao)括(kuo)充油電纜塞止(zhi)頭制作(zuo),供油箱(xiang)、自動排水及信號裝置的安裝等。

(6)接地工(gong)程:包括絕緣接頭、換位箱、保(bao)護(hu)器(qi)、接地箱安裝等。

74、電纜線路的(de)驗收應進(jin)行哪(na)些檢查?

答:(1)電纜規(gui)格應符合(he)規(gui)定,排列(lie)應整齊(qi)(qi),無損(sun)傷(shang),標(biao)牌(pai)齊(qi)(qi)全、正確、清(qing)晰;

(2)電纜(lan)的(de)固(gu)定彎(wan)曲半(ban)徑、有關距離及單芯電力電纜(lan)的(de)金屬(shu)護層(ceng)的(de)接線應符合要求;

(3)電纜終端、中間頭不(bu)滲(shen)漏油,安裝牢固,充油電纜油壓(ya)及表計整定值應符合要求;

(4)接(jie)地良好(hao);

(5)電(dian)纜終(zhong)端相(xiang)色正確,支(zhi)架等的金(jin)屬部件(jian)油漆完整;

(6)電纜溝及隧道內、橋架(jia)上(shang)應無雜物,蓋板齊全。

75、電纜線(xian)路(lu)正序阻抗測(ce)量過程中有什么要求(qiu)?

答:電纜導體的(de)交(jiao)流電阻和電纜三相同感抗的(de)相量和稱為正序阻抗。

電(dian)(dian)(dian)纜線路(lu)的(de)(de)正序阻抗一(yi)般(ban)可在電(dian)(dian)(dian)纜盤(pan)上直接測(ce)量(liang)(liang),測(ce)量(liang)(liang)時一(yi)般(ban)使用(yong)較低的(de)(de)電(dian)(dian)(dian)壓(ya)(ya)(ya),因此,需(xu)要(yao)用(yong)降(jiang)(jiang)壓(ya)(ya)(ya)變壓(ya)(ya)(ya)器進行降(jiang)(jiang)壓(ya)(ya)(ya),降(jiang)(jiang)壓(ya)(ya)(ya)器采用(yong)星形(xing)接線,容(rong)量(liang)(liang)一(yi)般(ban)為10kVA以上,有(you)較廣的(de)(de)電(dian)(dian)(dian)壓(ya)(ya)(ya)調節范圍,測(ce)量(liang)(liang)時交流電(dian)(dian)(dian)源應比(bi)較穩定(ding),以保證(zheng)測(ce)量(liang)(liang)時電(dian)(dian)(dian)流達(da)到(dao)規定(ding)的(de)(de)要(yao)求,實際電(dian)(dian)(dian)壓(ya)(ya)(ya)表(biao)的(de)(de)讀(du)數(shu)(shu)值(zhi)必須是電(dian)(dian)(dian)纜端(duan)的(de)(de)電(dian)(dian)(dian)壓(ya)(ya)(ya),試驗(yan)電(dian)(dian)(dian)流更好 接近(jin)電(dian)(dian)(dian)纜長期允許(xu)載流量(liang)(liang),測(ce)讀(du)各表(biao)計的(de)(de)數(shu)(shu)值(zhi)時,合上電(dian)(dian)(dian)流后(hou)同(tong)時讀(du)取三(san)個(ge)表(biao)的(de)(de)數(shu)(shu)值(zhi)。

76、根(gen)據《電(dian)業生產安(an)全(quan)規定(ding)》,電(dian)氣工作人員必須具備的條件是什么?

答:必(bi)須具備下列條件(jian):

(1)經醫(yi)生鑒定身體健康,無(wu)妨礙工作的病癥(zheng);

(2)具(ju)備必要的電氣知識(shi),按其職(zhi)務和工作(zuo)性質(zhi)掌握相關(guan)的規程(cheng)、專業(ye)技術及安全(quan)操作(zuo)技術,并(bing)經(jing)考試合格;

(3)熟練掌握觸電急救方(fang)法(fa)。

77、電纜在(zai)運輸裝卸過(guo)程(cheng)中應注意(yi)什么?

答:(1)在運輸裝卸過程中,不應使電(dian)纜(lan)及電(dian)纜(lan)盤受到損傷,嚴禁將(jiang)電(dian)纜(lan)盤直(zhi)接由車上推下,電(dian)纜(lan)般(ban)不應平放運輸,平放貯存。

(2)運輸或滾動電(dian)纜(lan)盤(pan)前(qian),必須保證電(dian)纜(lan)盤(pan)牢固,電(dian)纜(lan)繞緊、充(chong)油(you)(you)電(dian)纜(lan)至壓(ya)(ya)力(li)油(you)(you)箱間的(de)油(you)(you)管應(ying)(ying)固定,不(bu)得損傷(shang),壓(ya)(ya)力(li)油(you)(you)箱應(ying)(ying)牢固,壓(ya)(ya)力(li)指示(shi)應(ying)(ying)符合要求。

78、電纜防火有哪些措施?

答:(1)采用阻燃電纜;

(2)采用防火(huo)電纜托架;

(3)采用防火涂(tu)料;

(4)電纜隧道、夾層出口等處設置防火隔墻(qiang)、防火擋板;

(5)架空電纜應(ying)避開油管道、防(fang)爆門,否則應(ying)有要取局部(bu)穿管或隔熱防(fang)火措施。

79、選(xuan)擇電力電纜的截面應從(cong)哪幾(ji)個方面考慮?

答:應考慮如下幾個(ge)方面:

(1)電(dian)纜長期(qi)允(yun)許(xu)通過(guo)的工作電(dian)流;

(2)一旦短路時(shi)的熱穩(wen)定(ding)性;

(3)線(xian)路上的電壓降(jiang)不能超出允(yun)許工(gong)作范圍。

80、電力電纜和架空線比較有(you)哪些優點?

答:(1)運行可靠,由(you)于安(an)裝在地下(xia)等隱蔽處,受外力破壞小,發(fa)生故障的機會較少,供電安(an)全,不會給人身造成危害;

(2)維護工作量小,不需(xu)頻繁的巡檢;

(3)不需(xu)架設桿(gan)塔;

(4)有助于提高(gao)功率(lv)因數(shu)。