1、常用(yong)的電(dian)(dian)線、電(dian)(dian)纜按用(yong)途分有哪些種類?

答:按用途可分(fen)為裸導線(xian)、絕(jue)緣電(dian)(dian)(dian)線(xian)、耐熱(re)電(dian)(dian)(dian)線(xian)、屏蔽(bi)電(dian)(dian)(dian)線(xian)、電(dian)(dian)(dian)力電(dian)(dian)(dian)纜、控制電(dian)(dian)(dian)纜、通信電(dian)(dian)(dian)纜、射頻電(dian)(dian)(dian)纜等。


2、絕緣電線有哪幾種?

答:常(chang)有(you)的絕(jue)(jue)緣(yuan)(yuan)(yuan)(yuan)(yuan)電(dian)(dian)線(xian)(xian)(xian)有(you)以下(xia)幾種:聚(ju)(ju)氯(lv)乙烯絕(jue)(jue)緣(yuan)(yuan)(yuan)(yuan)(yuan)電(dian)(dian)線(xian)(xian)(xian)、聚(ju)(ju)氯(lv)乙烯絕(jue)(jue)緣(yuan)(yuan)(yuan)(yuan)(yuan)軟(ruan)線(xian)(xian)(xian)、丁腈聚(ju)(ju)氯(lv)乙烯混合物絕(jue)(jue)緣(yuan)(yuan)(yuan)(yuan)(yuan)軟(ruan)線(xian)(xian)(xian)、橡(xiang)(xiang)皮絕(jue)(jue)緣(yuan)(yuan)(yuan)(yuan)(yuan)電(dian)(dian)線(xian)(xian)(xian)、農用(yong)地下(xia)直埋鋁芯塑(su)料絕(jue)(jue)緣(yuan)(yuan)(yuan)(yuan)(yuan)電(dian)(dian)線(xian)(xian)(xian)、橡(xiang)(xiang)皮絕(jue)(jue)緣(yuan)(yuan)(yuan)(yuan)(yuan)棉紗(sha)紡織軟(ruan)線(xian)(xian)(xian)、聚(ju)(ju)氯(lv)乙烯絕(jue)(jue)緣(yuan)(yuan)(yuan)(yuan)(yuan)尼龍(long)護套電(dian)(dian)線(xian)(xian)(xian)、電(dian)(dian)力和照明用(yong)聚(ju)(ju)氯(lv)乙烯絕(jue)(jue)緣(yuan)(yuan)(yuan)(yuan)(yuan)軟(ruan)線(xian)(xian)(xian)等。


3、電纜橋架適合于何種場合?

答(da):電(dian)纜橋架(jia)(jia)適用于(yu)一(yi)般工礦企業室內外架(jia)(jia)空敷設電(dian)力(li)電(dian)纜、控(kong)制電(dian)纜,亦可用于(yu)電(dian)信、廣播電(dian)視(shi)等部(bu)門在室內外架(jia)(jia)設。


4、電纜(lan)附件有哪些?

答:常用(yong)的電(dian)附件(jian)有電(dian)纜終端接(jie)(jie)(jie)線(xian)盒、電(dian)纜中間(jian)接(jie)(jie)(jie)線(xian)盒、連接(jie)(jie)(jie)管及接(jie)(jie)(jie)線(xian)端子(zi)、鋼板(ban)接(jie)(jie)(jie)線(xian)槽、電(dian)纜橋架等。


5、什么叫電(dian)纜中間(jian)接頭?

答:連(lian)接電(dian)(dian)纜(lan)(lan)與(yu)電(dian)(dian)纜(lan)(lan)的(de)導體、絕緣屏(ping)蔽層和(he)保護層,以使電(dian)(dian)纜(lan)(lan)線路連(lian)接的(de)裝置,稱為(wei)電(dian)(dian)纜(lan)(lan)中間接頭。


6、什么(me)叫電氣(qi)主接(jie)線?

答:電(dian)氣(qi)主(zhu)接(jie)線是發電(dian)廠、變電(dian)所中主(zhu)要(yao)電(dian)氣(qi)設(she)備(bei)和母線的(de)連(lian)接(jie)方式,包括主(zhu)母線和廠用電(dian)系(xi)統按一定的(de)功能要(yao)求的(de)連(lian)接(jie)方式。


7、在選擇電力(li)電纜的截面時,應(ying)遵照哪些規定?

答:電(dian)(dian)(dian)力電(dian)(dian)(dian)纜(lan)的(de)選擇(ze)應遵照以下原則(ze):(1)電(dian)(dian)(dian)纜(lan)的(de)額定(ding)(ding)電(dian)(dian)(dian)壓(ya)要(yao)(yao)大(da)于(yu)或等于(yu)安(an)裝點(dian)供電(dian)(dian)(dian)系統的(de)額定(ding)(ding)電(dian)(dian)(dian)壓(ya);(2)電(dian)(dian)(dian)纜(lan)持(chi)續容許(xu)電(dian)(dian)(dian)流應等于(yu)或大(da)于(yu)供電(dian)(dian)(dian)負載的(de)更大(da) 持(chi)續電(dian)(dian)(dian)流;(3)線芯(xin)截面要(yao)(yao)滿足供電(dian)(dian)(dian)系統短路時的(de)穩定(ding)(ding)性(xing)的(de)要(yao)(yao)求;(4)根據(ju)電(dian)(dian)(dian)纜(lan)長度驗(yan)算(suan)電(dian)(dian)(dian)壓(ya)降(jiang)是否符合(he)要(yao)(yao)求;(5)線路末端的(de)最小短路電(dian)(dian)(dian)流應能(neng)使保護裝置可靠的(de)動作。


8、交聯聚(ju)乙(yi)烯電(dian)纜(lan)和油紙(zhi)電(dian)纜(lan)比(bi)較有哪些(xie)優點?

答:(1)易安裝(zhuang),因為它允許(xu)(xu)最小彎曲半徑小、且(qie)重(zhong)量輕;(2)不(bu)受線路落(luo)差*;(3)熱性能好,允許(xu)(xu)工作溫(wen)度高(gao)、傳輸容量大;(4)電纜附(fu)件簡單,均為干式結構;(5)運行(xing)維(wei)護簡單,無漏油問題(ti);(6)價格(ge)較低;(7)可靠性高(gao)、故(gu)障率低;(8)制造工序少(shao)、工藝簡單,經濟效益(yi)顯著。


9、固定交(jiao)流(liu)單芯(xin)電纜的夾(jia)具有(you)什么(me)(me)要求?為什么(me)(me)?

答(da):夾(jia)具應無鐵件構成閉(bi)合磁路,這是因為當電(dian)(dian)(dian)纜(lan)線(xian)芯通過電(dian)(dian)(dian)流時,在其(qi)周圍產生磁力線(xian),磁力線(xian)與通過線(xian)芯的(de)電(dian)(dian)(dian)流大小成正比,若(ruo)使(shi)(shi)用(yong)(yong)鐵件等(deng)導磁材料,根據電(dian)(dian)(dian)磁感應可知(zhi),將在鐵件中產生渦(wo)流使(shi)(shi)電(dian)(dian)(dian)纜(lan)發熱,甚至燒壞電(dian)(dian)(dian)纜(lan)。所(suo)以不(bu)可使(shi)(shi)用(yong)(yong)鐵件作單芯交流電(dian)(dian)(dian)纜(lan)的(de)固(gu)定(ding)夾(jia)具。


10、以下的熱縮電纜頭的附件(jian)的更大 特點和(he)優點是什么?

答:熱縮(suo)附件的(de)更大 特點(dian)是用應力管代替(ti)傳(chuan)統(tong)的(de)應力錐(zhui),它不僅簡化(hua)了施工工藝,還縮(suo)小了接(jie)頭的(de)終端的(de)尺寸,安裝方便,省時(shi)省工,性能(neng)優越,節約金屬。熱縮(suo)電纜附件集(ji)灌(guan)注(zhu)式(shi)和干包式(shi)為一體(ti),集(ji)合了這兩(liang)種(zhong)附件的(de)優點(dian)。


11、電(dian)纜(lan)敷(fu)設前(qian)應進行(xing)哪些檢查工作?

答(da):(1)支架應(ying)齊全、油漆完整。(2)電(dian)纜(lan)型號、電(dian)壓、規格(ge)符合(he)設計。(3)電(dian)纜(lan)絕緣良好,當對油紙電(dian)纜(lan)的(de)密封(feng)有(you)懷疑時,應(ying)進行受潮判斷(duan);直(zhi)埋電(dian)纜(lan)與小(xiao)底電(dian)纜(lan)應(ying)經直(zhi)流(liu)耐壓試難合(he)格(ge);充油電(dian)纜(lan)的(de)油樣應(ying)試驗合(he)格(ge)。(4)充油電(dian)纜(lan)的(de)油壓不宜低(di)于(yu)1.47MPa。


11、交聯熱收縮電纜(lan)附(fu)件有哪些優點?

答:這(zhe)是一種新(xin)型材料(liao),它與現(xian)在其他類(lei)型附件比較具有(you)電氣(qi)性能(neng)優(you)越(yue)、體積小(xiao)、質量小(xiao)、安裝簡便、材料(liao)配套(tao)等(deng)優(you)點,另外還具有(you)耐(nai)氣(qi)候(hou)、抗污穢(hui)性、阻(zu)燃自熄等(deng)能(neng)力。


12、對油紙絕緣(yuan)電力電纜(lan)密封有懷疑時,如何用(yong)較簡(jian)單的辦法(fa)檢查電纜(lan)絕緣(yuan)紙是否受(shou)潮?

答(da):把電纜絕緣紙點(dian)燃(ran)或(huo)放入150℃左右(you)的電纜油(you)中檢查,無“嘶嘶”聲或(huo)白(bai)色泡沫(mo)出現,說明未受潮。


13、電纜標志(zhi)牌應注(zhu)明(ming)什么內容?編(bian)寫有何(he)要求?

答:標志牌(pai)上應(ying)注明(ming)電(dian)纜(lan)線路設計編號(hao)、電(dian)纜(lan)型號(hao)、規格及始點,并聯使用的(de)電(dian)纜(lan)應(ying)有(you)順序號(hao)。要求(qiu)字跡清晰、不易脫(tuo)落。


14、直埋電纜(lan)的方位標志應設置在哪些位置?

答:在(zai)電(dian)纜(lan)兩端(duan),電(dian)纜(lan)直(zhi)線段(duan)50~100m處(chu)電(dian)纜(lan)接頭幾(ji)電(dian)纜(lan)改變方向的彎角處(chu)。


15、制作電纜接頭用的(de)黃臘(la)綢(chou)帶、黑(hei)玻璃漆帶、無堿玻璃絲帶等,施工前如何進行排潮處(chu)理?

答:(1)恒(heng)溫(wen)干燥(zao)法:將(jiang)絕(jue)緣帶卷成直徑為25~30mm小(xiao)卷,放入(ru)110~120℃恒(heng)溫(wen)干燥(zao)箱內(nei)烘(hong)4~5h,冷(leng)卻干取出,放入(ru)干燥(zao)的密封(feng)筒內(nei)。(2)油(you)浸排潮法:將(jiang)絕(jue)緣帶小(xiao)卷放入(ru)恒(heng)溫(wen)在(zai)120~130℃的電纜油(you)中,離(li)鍋(guo)底(di)保持30mm距離(li),經一(yi)定時間后油(you)面不再(zai)產生(sheng)泡沫(mo)后取出,裝入(ru)貯有(you)電纜油(you)的桶中,油(you)位應超過所有(you)裝入(ru)的物體并將(jiang)其(qi)密封(feng)。


16、電纜外護層的作用是什么?

答:保護內護層(ceng)不受機械損傷和化學腐蝕(shi),增強(qiang)機械強(qiang)度。


17、室外(wai)電纜溝應符合(he)哪些(xie)要求?

答:電纜溝上部應比地面稍高,加蓋(gai)用混凝土制作的(de)蓋(gai)板,電纜應平敷在支(zhi)架上,有良好(hao)的(de)排水管。


18、電纜內護層的(de)作用是(shi)什么?

答(da);使絕緣(yuan)層不會與水、空氣(qi)或其(qi)他物體(ti)接觸(chu),防(fang)止絕緣(yuan)受潮(chao)和絕緣(yuan)層不受機械傷害(hai)。


19、使用鋼絲鉗時(shi)應注意些什么?

答:使(shi)用(yong)前,一(yi)定(ding)要(yao)檢查絕緣柄的絕緣是否完好無(wu)損(sun),使(shi)用(yong)時不可(ke)用(yong)鋼絲鉗(qian)剪切超(chao)過規格(ge)所允(yun)許的金屬線(xian)材,并禁止用(yong)鋼絲鉗(qian)代替錘子敲(qiao)打工具(ju),以免損(sun)壞。


20、什么叫絕(jue)緣強度(du)?

答:絕緣(yuan)物質在電(dian)場(chang)中,當電(dian)場(chang)強(qiang)度增大到某一(yi)極限時就會被擊(ji)穿,這個導(dao)致絕緣(yuan)擊(ji)穿的(de)電(dian)場(chang)強(qiang)度稱為絕緣(yuan)強(qiang)度。


22、對(dui)電纜導體(ti)連接(jie)點(dian)的(de)機械強度有何要(yao)求(qiu)?

答:連接(jie)點的(de)(de)機械強(qiang)(qiang)度(du)(du),一般低于(yu)電纜導體(ti)(ti)本身(shen)的(de)(de)抗拉(la)(la)強(qiang)(qiang)度(du)(du),對于(yu)固定敷設的(de)(de)電力(li)電纜,其連接(jie)點的(de)(de)抗拉(la)(la)強(qiang)(qiang)度(du)(du)要(yao)求不低于(yu)導體(ti)(ti)本身(shen)抗拉(la)(la)強(qiang)(qiang)度(du)(du)的(de)(de)60%。


23、電力(li)電纜(lan)的(de)絕(jue)緣層材料應具備哪些主(zhu)要性(xing)能?

答;應具(ju)備下列主要(yao)性能:(1)高的擊穿(chuan)強度;(2)低的介(jie)質損耗;(3)相(xiang)當高的絕(jue)緣電(dian)阻(zu);(4)優(you)良(liang)的耐放(fang)電(dian)性能;(5)具(ju)有(you)一定(ding)的柔軟性和(he)機械強度;(6)絕(jue)緣性能長期穩定(ding)。


24、機械敷設電纜時,牽引強度有(you)何規定?

答:對(dui)(dui)于(yu)銅芯電(dian)纜,當牽引頭(tou)部(bu)時(shi),允(yun)許牽引強度(du)為70N/cm;對(dui)(dui)于(yu)鋁芯電(dian)纜,當牽引頭(tou)部(bu)時(shi),允(yun)許牽引強度(du)為40N/cm;若利用(yong)鋼絲網(wang)套(tao)(tao)牽引時(shi),鉛護套(tao)(tao)電(dian)纜允(yun)許強度(du)為10N/cm;鉛護套(tao)(tao)電(dian)纜為40N/cm。


25、對電纜(lan)保(bao)護管有何規定(ding)?

答:(1)電(dian)纜(lan)(lan)需要穿保護(hu)管敷設時,管子內徑(jing)不應小于電(dian)纜(lan)(lan)外(wai)徑(jing)的1.5倍,混凝土管、陶土管、石棉、水泥管的內徑(jing)不應小于100mm;

(2)電(dian)纜管的彎曲半徑應符合(he)所穿入電(dian)纜彎曲半徑的規定;

(3)每根管子最多不應超過三個彎頭(tou),直(zhi)角彎不應多于2個。

26、如何測(ce)量電(dian)纜護套的外徑(jing)?

答(da):在護套圓(yuan)周上均(jun)勻(yun)分(fen)布的五點處(chu),測量護套外徑(jing)和其(qi)平均(jun)值,其(qi)平均(jun)外徑(jing)既為護套的外徑(jing)。

27、不同截面的銅芯電纜如何連接?

答(da):不同截面的銅(tong)芯電纜連接(jie)(jie),可采用開口弱背銅(tong)接(jie)(jie)管,以(yi)錫焊(han)法連接(jie)(jie),也可用純銅(tong)棒按不同的截面要求連接(jie)(jie)成銅(tong)接(jie)(jie)管,以(yi)壓接(jie)(jie)法連接(jie)(jie)。

28、簡述10KV交聯電纜熱縮式制作戶內(nei)終端(duan)頭(tou)的(de)過程?

答;(1)準備(bei)階段:檢查(cha)熱縮電(dian)纜(lan)附件是否(fou)齊(qi)備(bei),型號是否(fou)相配,檢查(cha)并確(que)認(ren)電(dian)纜(lan)有無(wu)潮(chao)氣后,檢查(cha)電(dian)纜(lan)。

(2)切除(chu)多余電纜(lan),根據(ju)現場情況(kuang)決定電纜(lan)長度。

(3)剝(bo)除護層。

(4)焊接(jie)接(jie)地(di)線,將(jiang)接(jie)地(di)線焊接(jie)在鋼帶上。

(5)填充三叉口及繞包密封(feng)膠。

(6)安裝(zhuang)三芯分支護套(tao),將(jiang)護套(tao)套(tao)入根部,從中部開始(shi)收縮(suo),先往根部,再往指部。

(7)剝(bo)銅(tong) 帶(dai)和外半(ban)(ban)導電(dian)層,剝(bo)切三芯分(fen)支(zhi)套口20mm以上的銅(tong)帶(dai),嚴禁損傷主絕緣,清除干(gan)凈半(ban)(ban)導電(dian)層。

(8)安裝應力管,管口端(duan)部分支套對接后熱(re)縮。

(9)安裝接(jie)線端子(zi)。

(10)安裝絕(jue)緣管(guan)。

(11)安裝密封管(guan)。

(12)核相后安裝相色管。

29、戶(hu)內(nei)、戶(hu)外預制(zhi)式終端安裝(zhuang)步驟有哪(na)些?

答(da):(1) 將電纜(lan)按預定位(wei)置就位(wei)、固定、清(qing)潔(jie)表面,參照說明書(shu)剝除(chu)外護套,如(ru)有特殊需要,外護套剝切長度(du)可調整,分別(bie)由銅(tong)帶、外護套鎧裝引(yin)出2組地線。

(2) 由(you)外護套(tao)口(kou)向上量(liang)取需要尺寸(cun),切除多(duo)余電纜,套(tao)入熱縮三(san)指套(tao)至三(san)叉口(kou)根部由(you)中間加熱收縮,由(you)指套(tao)上口(kou)向上量(liang)取規定(ding)尺寸(cun)(35kv為350~380mm)。去掉多(duo)余銅帶(保(bao)留20mm),再保(bao)留半(ban)導體預定(ding)位(wei)置,壓接(jie)出線端子密封(feng)。

30、電(dian)線電(dian)纜的應用主(zhu)要分為三(san)大類 :

(1)、電力系統

電(dian)(dian)力系統采用的電(dian)(dian)線(xian)電(dian)(dian)纜(lan)(lan)產品主要(yao)有架空(kong)裸電(dian)(dian)線(xian)、匯流排(母線(xian))、電(dian)(dian)力電(dian)(dian)纜(lan)(lan)(塑(su)料線(xian)纜(lan)(lan)、油紙(zhi)力纜(lan)(lan)(基(ji)本被塑(su)料電(dian)(dian)力電(dian)(dian)纜(lan)(lan)代替)、橡(xiang)套線(xian)纜(lan)(lan)、架空(kong)絕緣電(dian)(dian)纜(lan)(lan))、分支電(dian)(dian)纜(lan)(lan)(取代部分母線(xian))、電(dian)(dian)磁(ci)線(xian)以(yi)及電(dian)(dian)力設備(bei)(bei)用電(dian)(dian)氣裝備(bei)(bei)電(dian)(dian)線(xian)電(dian)(dian)纜(lan)(lan)等。

(2)、信(xin)息傳輸系統

用于信(xin)息傳輸系統的電(dian)(dian)線電(dian)(dian)纜(lan)主(zhu)要(yao)有市(shi)話電(dian)(dian)纜(lan)、電(dian)(dian)視電(dian)(dian)纜(lan)、電(dian)(dian)子線纜(lan)、射頻電(dian)(dian)纜(lan)、光纖纜(lan)、數(shu)據(ju)電(dian)(dian)纜(lan)、電(dian)(dian)磁線、電(dian)(dian)力通(tong)訊或其他復合電(dian)(dian)纜(lan)等。

(3)、機械設備、儀器(qi)儀表系統

此部分除架空裸電(dian)線(xian)外幾乎其他所有產(chan)品均有應用,但主要是(shi)電(dian)力電(dian)纜(lan)、電(dian)磁線(xian)、數據電(dian)纜(lan)、儀(yi)器儀(yi)表線(xian)纜(lan)等。

31、電(dian)線電(dian)纜產品主要分(fen)為五大類(lei):

(1)、裸(luo)電線及裸(luo)導(dao)體制品(pin) 本類產品(pin)的(de)(de)主(zhu)要特征是(shi):純的(de)(de)導(dao)體金(jin)屬(shu),無絕緣及護套層,如鋼芯鋁絞(jiao)線、銅鋁匯流(liu)排、電力機車線等;加工工藝主(zhu)要是(shi)壓力加工,如熔煉、壓延、拉制、絞(jiao)合(he)/緊壓絞(jiao)合(he)等;產品(pin)主(zhu)要用在城(cheng)郊、農村(cun)、用戶(hu)主(zhu)線、開(kai)關(guan)柜等。

(2)、電力電纜本類產品主要特征是(shi):在導體外擠(ji)(繞(rao))包(bao)(bao)絕(jue)(jue)緣(yuan)層,如架空絕(jue)(jue)緣(yuan)電纜,或幾芯絞(jiao)合(he)(對應電力系統的(de)相線、零線和地(di)線),如二芯以上架空絕(jue)(jue)緣(yuan)電纜,或再增加護套層,如塑料(liao)/橡套電線電纜。主要的(de)工藝技術有(you)拉(la)制(zhi)、絞(jiao)合(he)、絕(jue)(jue)緣(yuan)擠(ji)出(繞(rao)包(bao)(bao))、成纜、鎧(kai)裝、護層擠(ji)出等(deng),各種產品的(de)不(bu)同(tong)工序組合(he)有(you)一定(ding)區別。

產品主要(yao)用在發、配、輸、變、供電線(xian)路中(zhong)的強電電能傳輸,通(tong)過的電流大(幾(ji)十安(an)至幾(ji)千安(an))、電壓(ya)高(220V至500kV及以上)。

(3)、電(dian)(dian)氣(qi)裝備用(yong)(yong)(yong)電(dian)(dian)線(xian)(xian)電(dian)(dian)纜(lan)(lan)該(gai)類產品主要特征是:品種規(gui)格繁多(duo),應用(yong)(yong)(yong)范圍廣泛(fan),使用(yong)(yong)(yong)電(dian)(dian)壓在1kV及以下(xia)較多(duo),面對特殊場合不斷(duan)衍生新的產品,如耐(nai)(nai)火線(xian)(xian)纜(lan)(lan)、阻燃(ran)線(xian)(xian)纜(lan)(lan)、低(di)煙(yan)無鹵/低(di)煙(yan)低(di)鹵線(xian)(xian)纜(lan)(lan)、防白蟻、防老鼠線(xian)(xian)纜(lan)(lan)、耐(nai)(nai)油/耐(nai)(nai)寒/耐(nai)(nai)溫/耐(nai)(nai)磨線(xian)(xian)纜(lan)(lan)、醫用(yong)(yong)(yong)/農用(yong)(yong)(yong)/礦用(yong)(yong)(yong)線(xian)(xian)纜(lan)(lan)、薄壁電(dian)(dian)線(xian)(xian)等(deng)。

(4)、通訊電(dian)纜(lan)(lan)及光纖(xian)(簡略(lve)介紹)隨(sui)著近(jin)二十多年(nian)來(lai),通訊行業的(de)飛(fei)速發展,產品也有驚人(ren)的(de)發展速度。從過(guo)去的(de)簡單(dan)的(de)電(dian)話(hua)電(dian)報線纜(lan)(lan)發展到(dao)幾千對的(de)話(hua)纜(lan)(lan)、同軸纜(lan)(lan)、光纜(lan)(lan)、數據電(dian)纜(lan)(lan),甚至組合通訊纜(lan)(lan)等。

該(gai)類產品結構(gou)尺寸通常較小而均勻,制造精度要求高。

(5)、電磁線(xian)(繞組(zu)線(xian))主要(yao)用(yong)于各種電機(ji)、儀(yi)器儀(yi)表等。

電(dian)線電(dian)纜的衍生(sheng)/新(xin)產品(pin)

電(dian)線電(dian)纜(lan)的衍生/新產(chan)品(pin)(pin)主要是因(yin)應(ying)用場合(he)、應(ying)用要求(qiu)不(bu)同及裝備的方便性和降低裝備成本等的要求(qiu),而采用新材(cai)料、特殊材(cai)料、或改變(bian)產(chan)品(pin)(pin)結構、或提高(gao)工藝(yi)要求(qiu)、或將(jiang)不(bu)同品(pin)(pin)種的產(chan)品(pin)(pin)進行組合(he)而產(chan)生。

采用不同材(cai)料如阻燃線(xian)纜(lan)、低煙無鹵/低煙低鹵線(xian)纜(lan)、防白蟻(yi)、防老(lao)鼠線(xian)纜(lan)、耐油/耐寒/耐溫線(xian)纜(lan)等;

改變(bian)產品結構如:耐火電纜等;

提高工藝要求(qiu)如(ru):醫用(yong)線纜等(deng);

組合(he)產(chan)品如:OPGW等;

方便安裝和降低裝備成本如:預(yu)制(zhi)分支電纜(lan)等。

32、母線(xian)裝(zhuang)置施工(gong)完,應進行(xing)哪些檢查?

答:應進行(xing)下列檢查:

(1)金屬構件的加工、配制、焊接螺接應符合規定(ding);

(2)各部螺(luo)栓(shuan)、墊(dian)圈(quan)、開(kai)口銷等零部件應(ying)齊(qi)全可(ke)靠;

(3)母線配制及安裝架應符合規定,相間及對地電(dian)氣距離符合要求;

(4)瓷件(jian)、鐵件(jian)及(ji)膠合(he)處應完整,充油(you)套管(guan)應無滲油(you),油(you)位正常;

(5)油漆完整,相色正確,接(jie)地良(liang)好。

33、在35kv及以下電(dian)(dian)力(li)電(dian)(dian)纜接頭(tou)中,改善其護套斷開處電(dian)(dian)場分布的方(fang)法有幾種(zhong)(請(qing)列出五種(zhong)),并簡述(shu)其方(fang)法。

答:(1)脹喇(la)叭(ba)(ba)口:在鉛包割斷處把鉛包邊緣撬起,成喇(la)叭(ba)(ba)狀,其邊緣應光滑、圓整、對稱(cheng)。

(2)預留統包(bao)絕(jue)緣(yuan):在(zai)鉛包(bao)切口至電纜(lan)芯(xin)線分開點之間留有一段統包(bao)絕(jue)緣(yuan)紙(zhi)。

(3)切(qie)除(chu)半(ban)導電紙:將半(ban)導電紙切(qie)除(chu)到喇叭口以下。

(4)包(bao)(bao)繞應力錐:用絕緣包(bao)(bao)帶和導電金屬(shu)材料包(bao)(bao)成錐形,人為(wei)地(di)將屏蔽(bi)層(ceng)擴大,以改(gai)善(shan)電場分布(bu)。

(5)等電位法:對于干包型或(huo)交聯聚乙烯電纜頭,在(zai)各線芯概況絕緣表面(mian)上包一段金屬帶(dai),并將其連接在(zai)一起(qi)。

(6)裝設應(ying)力控(kong)制管(guan):對于35kv及發下(xia)熱縮(suo)(suo)管(guan)電纜頭,首(shou)先從線芯(xin)銅(tong)屏蔽(bi)層末(mo)端(duan)方向經半(ban)導(dao)(dao)體帶至線芯(xin)絕緣(yuan)概況包繞2層半(ban)導(dao)(dao)體帶,然后將相應(ying)規(gui)格折應(ying)力管(guan),套在銅(tong)屏蔽(bi)的末(mo)端(duan)處,熱縮(suo)(suo)成形(xing)。

34、電纜支(zhi)架的加工應符合哪(na)些(xie)要求?

答:(1)鋼材(cai)應(ying)平直,無(wu)明(ming)顯扭曲(qu),下(xia)料誤差應(ying)在5mm范圍內,切口應(ying)無(wu)卷邊,毛剌;

(2)支架應焊接牢固,無(wu)顯(xian)蓍(shi)變形(xing),各橫撐(cheng)間的垂直(zhi)凈(jing)距(ju)與設(she)計偏差不應大于5mm;

(3)金(jin)屬支架必須進行防(fang)腐處(chu)理(li)(li),位于濕熱(re)、鹽、霧以及有(you)化學(xue)腐蝕地區時,應根據設計(ji)作特殊的(de)防(fang)腐處(chu)理(li)(li)。

35、列舉出你熟悉的電纜架。

答:拼焊式(shi)E型(xing)架、裝配式(shi)E型(xing)架、橋式(shi)電(dian)纜(lan)架、電(dian)纜(lan)托架、掛鉤(gou)式(shi)支架、單根電(dian)纜(lan)支架等。

36、敷設(she)電纜應滿(man)足哪些要求(qiu)?

答:應滿足(zu)以下(xia)要求:

(1)安(an)全運(yun)行方面,盡可能(neng)避免各(ge)種外來損壞,提高(gao)電纜線路的(de)供(gong)電可靠(kao)性;

(2)經濟方面,從投資(zi)最省的(de)方面考慮;

(3)施(shi)工(gong)方面,電纜(lan)線路(lu)的路(lu)徑必(bi)須便(bian)于旋工(gong)和投運(yun)后的維修。

37、制作電纜終端頭或中間接(jie)頭的絕緣材料(liao)有哪些?

答:有(you)絕(jue)(jue)(jue)緣(yuan)(yuan)(yuan)膠、絕(jue)(jue)(jue)緣(yuan)(yuan)(yuan)帶、絕(jue)(jue)(jue)緣(yuan)(yuan)(yuan)管、絕(jue)(jue)(jue)緣(yuan)(yuan)(yuan)手套、絕(jue)(jue)(jue)緣(yuan)(yuan)(yuan)樹脂(zhi)等。

38、簡述電纜(lan)(lan)頭(tou)制作(zuo)的(de)一般(ban)操作(zuo)程序。答:(1)制作(zuo)前(qian)的(de)準備(bei):包(bao)括○1閱(yue)讀安裝說明書;○2察看(kan)現(xian)場;○3備(bei)料(liao);○4電纜(lan)(lan)試潮;○5制作(zuo)前(qian)測試等。

(2)接頭的制作(zuo)過程(cheng):包(bao)括○1割斷(duan)多(duo)余(yu)電纜(lan);○2電纜(lan)保護層(ceng)的剝切;○3導(dao)體連接;○4包(bao)繞絕緣(或收縮管材);○5安裝接頭外殼;○6灌注絕緣劑;○7進行密封處理(li)等。

(3)制作后(hou)電(dian)氣測試(shi)。

39、電纜保護管(guan)的加工應符合哪些(xie)要求?

答:(1)管口應(ying)*剌(la)和(he)尖銳楞角,管口宜做成喇叭形。

(2)電(dian)纜(lan)管在彎制后,不(bu)應有裂縫和(he)顯著(zhu)的凹癟現象(xiang),其彎扁程度不(bu)宜大(da)于管子(zi)外徑(jing)10%;電(dian)纜(lan)管的彎曲(qu)半(ban)(ban)徑(jing)不(bu)應小于所穿入(ru)電(dian)纜(lan)的最小允許彎曲(qu)半(ban)(ban)徑(jing)。

(3)金屬管應(ying)在外表(biao)涂(tu)防(fang)腐漆或瀝表(biao),鍍鋅(xin)(xin)管鋅(xin)(xin)層剝落處也(ye)應(ying)涂(tu)以防(fang)腐漆。

40、電(dian)纜(lan)的排列符(fu)合哪些要求?答:(1)電(dian)力電(dian)纜(lan)和控纜(lan)不(bu)應配置在(zai)同一層支架上。

(2)高、低壓電纜(lan),強、弱電控纜(lan)應按須序分層(ceng)配置,一般情(qing)況宜由上而(er)下,但在含有35kv以上高壓電纜(lan)引(yin)入(ru)柜盤時,為滿足彎曲半徑(jing),可(ke)由下面上配置。

41、電(dian)(dian)纜溝內敷設電(dian)(dian)纜的方法是什么(me)?

答:在電(dian)纜(lan)溝(gou)內(nei)敷(fu)設(she)(she)電(dian)纜(lan)的方(fang)法(fa)與直埋(mai)電(dian)纜(lan)的敷(fu)設(she)(she)方(fang)法(fa)相(xiang)仿,一(yi)般可將(jiang)滑(hua)輪(lun)放在溝(gou)內(nei),施放完畢(bi),將(jiang)電(dian)纜(lan)放于溝(gou)底或支架上,并在電(dian)纜(lan)上綁扎電(dian)纜(lan)標(biao)牌。

42、電纜敷設的常用設備有哪些?

答:(1)空氣壓縮機,主要用(yong)來(lai)破壞路面,為以(yi)后敷設(she)電纜(lan)作準備(bei);

(2)電(dian)動卷揚機(ji)或(huo)電(dian)纜(lan)(lan)牽引機(ji),主要用來拖(tuo)電(dian)纜(lan)(lan);

(3)電纜(lan)輸送(song)機,配(pei)合牽引(yin)機使用(yong)來克服(fu)巨大的(de)摩擦力,減(jian)輕對電纜(lan)的(de)損壞;

(4)電(dian)纜盤(pan)放線支架;

(5)滾輪裝(zhuang)置;

(6)防捻(nian) ,減鋼(gang)絲繩出現(xian)的扭曲;

(7)電(dian)纜盤制動裝置;

(8)張力計。

43、電(dian)(dian)(dian)纜(lan)溝(gou)(gou)中支(zhi)架(jia)安裝距離(li)的(de)要(yao)求如何(he)?答(da):電(dian)(dian)(dian)纜(lan)固(gu)定(ding)于(yu)電(dian)(dian)(dian)纜(lan)溝(gou)(gou)和隧道的(de)墻(qiang)上,水平裝置(zhi)時,當(dang)電(dian)(dian)(dian)纜(lan)外徑等于(yu)或(huo)小于(yu)50mm時應每(mei)隔(ge)1m加一(yi)支(zhi)撐;外徑大于(yu)50mm的(de)電(dian)(dian)(dian)纜(lan)每(mei)隔(ge)0.6m加一(yi)支(zhi)撐;排成三角形(xing)的(de)單電(dian)(dian)(dian)纜(lan),每(mei)隔(ge)1m應用綁(bang)帶扎(zha)牢,垂直裝置(zhi)時,每(mei)隔(ge)1~1.5m加以(yi)固(gu)定(ding)。

44、如何(he)處理電(dian)(dian)力電(dian)(dian)纜與控制電(dian)(dian)纜在同一托架(jia)的(de)安(an)裝?

答:電(dian)力(li)電(dian)纜(lan)(lan)與控制電(dian)纜(lan)(lan)一(yi)般不應敷(fu)設(she)在同一(yi)托架內,當電(dian)纜(lan)(lan)較少而將控纜(lan)(lan)與電(dian)力(li)電(dian)纜(lan)(lan)敷(fu)設(she)在同一(yi)托架內時,應用隔板(ban)隔開。

45、電(dian)纜隧道內如(ru)何裝設接地(di)線(xian)?

答:隧道和(he)(he)溝的全長應(ying)(ying)裝(zhuang)設(she)連(lian)續的接地(di)線(xian),接地(di)線(xian)應(ying)(ying)和(he)(he)所有(you)的支(zhi)架(jia)相(xiang)連(lian),兩頭(tou)和(he)(he)接地(di)極連(lian)通。接地(di)線(xian)的規格應(ying)(ying)符合設(she)計要求。電纜(lan)鉛(qian)包(bao)和(he)(he)鎧(kai)裝(zhuang)除(chu)了有(you)絕緣要求外,應(ying)(ying)全部相(xiang)互連(lian)接并(bing)和(he)(he)接地(di)線(xian)相(xiang)連(lian),電纜(lan)架(jia)和(he)(he)接地(di)線(xian)均應(ying)(ying)涂防銹(xiu)漆(qi)或鍍鋅。

46、對(dui)于電(dian)纜孔(kong)洞的(de)防火(huo)封堵有(you)何(he)要求?

答:對于(yu)較大的電(dian)纜(lan)(lan)貫(guan)穿孔洞,如電(dian)纜(lan)(lan)貫(guan)穿樓板(ban)(ban)處等,采用防火(huo)堵(du)料(liao)封堵(du)時(shi)(shi),應根(gen)據實際情況,先在電(dian)纜(lan)(lan)表(biao)面涂四至六層防火(huo)涂料(liao),長度自孔洞以下1.5m左(zuo)右(you),再用耐(nai)火(huo)材料(liao)加(jia)工成(cheng)具(ju)有一定強(qiang)度的板(ban)(ban)托(tuo)防火(huo)堵(du)料(liao),保證封堵(du)后牢固并便于(yu)更(geng)換電(dian)纜(lan)(lan)時(shi)(shi)拆(chai)裝,封堵(du)密實無孔隙以有效地堵(du)煙堵(du)火(huo)。

47、噴燈(deng)點(dian)火前應注意(yi)哪些檢(jian)查?

答:應進行(xing)下列各項檢查:

(1)打氣(qi)筒是(shi)否(fou)漏油(you)或(huo)滲油(you),油(you)桶及噴嘴處是(shi)否(fou)漏油(you)、漏氣(qi);

(2)油桶內的油量是否(fou)(fou)超過油桶容量的3/4,加油的螺絲(si)塞(sai)是否(fou)(fou)擰緊(jin)。

48、使用噴燈應注(zhu)意哪些事項?

答:(1)噴燈更大 注油量為油筒容積的3/4;

(2)開始打(da)氣(qi)壓力不要(yao)太(tai)大,點燃后(hou)火焰由黃(huang)變藍即可使用;

(3)周圍不得有易(yi)燃物,空(kong)氣要流通;

(4)停用時先關閉調(diao)節開關,火熄(xi)后(hou),慢(man)慢(man)旋(xuan)松油(you)孔(kong)蓋放(fang)氣,空(kong)氣放(fang)完后(hou),要(yao)要(yao)旋(xuan)松調(diao)節開關,完全冷(leng)卻后(hou)再旋(xuan)松孔(kong)蓋;

(5)煤(mei)油噴燈與汽油噴燈要分(fen)開使用。

49、手動油壓鉗有何(he)用途?如(ru)何(he)操作(zuo)?

答:兩根導(dao)線(xian)的連(lian)接通(tong)常是將兩導(dao)線(xian)端穿入相同材料(liao)制成的壓(ya)(ya)(ya)管(guan)中(zhong),用壓(ya)(ya)(ya)接鉗擠壓(ya)(ya)(ya)數(shu)個坑(keng)(keng)(keng),使(shi)導(dao)線(xian)連(lian)接在一(yi)(yi)起,壓(ya)(ya)(ya)接時(shi),手柄向上抬起時(shi),柱塞(sai)(sai)向外移動(dong),進油(you)(you)閥(fa)下(xia)腔產生真空,油(you)(you)箱內的油(you)(you)進入柱塞(sai)(sai)腔。手柄下(xia)壓(ya)(ya)(ya)時(shi),柱塞(sai)(sai)向內移動(dong),油(you)(you)受壓(ya)(ya)(ya)后,使(shi)進油(you)(you)閥(fa)關閉,打開(kai)(kai)出油(you)(you)閥(fa),使(shi)油(you)(you)壓(ya)(ya)(ya)進入液(ye)壓(ya)(ya)(ya)缸,推動(dong)活塞(sai)(sai)和陽(yang)模,陽(yang)、陰模之間(jian)放有壓(ya)(ya)(ya)接管(guan),當壓(ya)(ya)(ya)接被擠壓(ya)(ya)(ya)的坑(keng)(keng)(keng)深到一(yi)(yi)定值時(shi),開(kai)(kai)啟回油(you)(you)閥(fa),活塞(sai)(sai)自動(dong)返回,壓(ya)(ya)(ya)完一(yi)(yi)個坑(keng)(keng)(keng)后,移動(dong)壓(ya)(ya)(ya)鉗,再壓(ya)(ya)(ya)下(xia)一(yi)(yi)個。

50、常用(yong)低壓電(dian)力電(dian)纜(lan)按絕緣(yuan)和保護層(ceng)的不同,主要可分為(wei)哪幾類?

答:(1)油浸(jin)紙(zhi)絕緣鉛包(或鋁包)電力電纜;

(2)不滴流(liu)油浸紙(zhi)絕緣電力電纜;

(3)聚(ju)氯乙烯(xi)絕緣(yuan)聚(ju)氯乙烯(xi)護套電力電纜;

(4)交聯聚氯乙烯絕緣聚乙烯護套電力電纜(lan);

(5)交(jiao)聯聚(ju)(ju)氯乙(yi)烯(xi)(xi)絕緣聚(ju)(ju)氯乙(yi)烯(xi)(xi)護(hu)套電力(li)電纜;

(6)橡皮絕緣電力(li)電纜(lan)。

51、常用絕緣(yuan)材料的類別哪些?舉例說明(ming)?

答:(1)無機絕緣材料(liao):有云母、石棉、大理石、瓷器、玻璃等;

(2)有(you)機絕緣材料(liao):有(you)樹脂(zhi)、橡膠、紙、麻、棉(mian)紗等;

(3)混合絕緣(yuan)材(cai)(cai)(cai)料:用以上絕緣(yuan)材(cai)(cai)(cai)料加(jia)工而成型的名種絕緣(yuan)材(cai)(cai)(cai)料。

52、在哪種情況下采用排管(guan)敷設?有什(shen)么優點?

答:排管敷設一(yi)般用在與其他建筑物、公路或鐵路相交叉的(de)(de)地方,有時也在建筑物密(mi)集區內采用。主(zhu)要(yao)優點是占地少,能承(cheng)受大的(de)(de)荷(he)重,電纜(lan)相互(hu)(hu)間互(hu)(hu)不影響,比較安全。

53、何謂電纜長期(qi)允許載(zai)流量?

答:電(dian)(dian)纜長(chang)期允許(xu)載流(liu)量是指在(zai)電(dian)(dian)纜內通(tong)過規(gui)定電(dian)(dian)流(liu)時(shi),在(zai)熱穩定后,電(dian)(dian)纜導體達到長(chang)期允許(xu)工作溫度時(shi)的電(dian)(dian)流(liu)數(shu)值。

54、決(jue)定電纜長(chang)期允許載流量(liang)的(de)因素有哪些(xie)?

答:有(you)以(yi)下三個因素決定:

(1)電纜的長(chang)期(qi)容許工作溫度;

(2)電纜本身的散熱性能;

(3)電纜裝(zhuang)置(zhi)情況及周圍環境的散(san)熱條件。

55、電纜(lan)的敷設方式有幾種?

答:有(you)以下幾種:

(1)直(zhi)埋(mai)在地下;

(2)安裝(zhuang)在電纜(lan)溝內;

(3)安裝在地下隧道(dao)內(nei);

(4)安裝在建筑(zhu)物內部墻上或(huo)天(tian)棚上;

(5)安裝在橋(qiao)架上;

(6)敷設在排管內(nei);

(7)敷設在水(shui)底。

56、如何進行(xing)電(dian)纜管的連接(jie)工作?

答(da):電(dian)纜管(guan)連接(jie)(jie)(jie)時,必須用(yong)(yong)扣(kou)和(he)管(guan)接(jie)(jie)(jie)頭連接(jie)(jie)(jie),如采用(yong)(yong)焊接(jie)(jie)(jie)時,不能直接(jie)(jie)(jie)對焊,連接(jie)(jie)(jie)處(chu)要套上一段粗(cu)管(guan)再進行焊接(jie)(jie)(jie),以免(mian)焊渣掉入管(guan)內。

57、制作(zuo)電纜頭時,對上下扳彎電纜芯(xin)線有何要(yao)求?

答:扳彎線芯時,不(bu)得損傷(shang)(shang)紙絕(jue)緣,芯線的彎曲半徑(jing)不(bu)得小于電纜(lan)線芯的10倍。制作時要(yao)特別(bie)小心,應(ying)使(shi)線芯彎曲部分均勻(yun)受力(li),否則(ze)極易損傷(shang)(shang)絕(jue)緣紙。

58、簡述塑料電纜的熱收縮(suo)密封法。

答(da):熱(re)縮(suo)法適用(yong)于(yu)中、低壓橡、塑電(dian)纜(lan)接(jie)頭(tou)和(he)終端頭(tou)的(de)(de)密(mi)(mi)封(feng),也可(ke)適用(yong)于(yu)不滴流(liu)和(he)黏性浸漬絕緣電(dian)纜(lan)。采用(yong)交聯聚乙烯型和(he)硅橡膠型兩大類遇熱(re)后(hou)能均勻收(shou)(shou)縮(suo)的(de)(de)熱(re)收(shou)(shou)縮(suo)管。將這種管材套于(yu)預定的(de)(de)粘合(he)密(mi)(mi)封(feng)部位(wei),并在粘和(he)部位(wei)涂(tu)上熱(re)熔膠,當(dang)加熱(re)到一(yi)定溫度后(hou),熱(re)縮(suo)管將收(shou)(shou)縮(suo),同時熱(re)熔膠熔化,待自(zi)然冷卻后(hou)即形(xing)成一(yi)道良好的(de)(de)密(mi)(mi)封(feng)封(feng)層。

59、用電動彎管機彎制電纜(lan)保護管時(shi)應注意什(shen)么?

答(da):(1)彎管機應由了(le)解其性能并熟悉操(cao)作知識的人員操(cao)作;

(2)使(shi)用前必須(xu)進行檢(jian)查,按鈕、操(cao)作(zuo)把手(shou)、行程(cheng)開關(guan)應(ying)完好,彎(wan)管機必須(xu)可靠接地;

(3)選用符合(he)要(yao)求的(de)模具,確定好所需要(yao)的(de)彎曲半徑;

(4)施工場地周圍,應有充足的活動(dong)范圍;

(5)使用時待空(kong)轉(zhuan)正(zheng)常后,方可帶負(fu)荷(he)工作(zuo),運行中,嚴禁用手腳接觸其(qi)轉(zhuan)動部分;

(6)工(gong)作完畢應及(ji)時停電(dian),釋放油壓(ya)。

60、電纜清冊(ce)的(de)(de)內容及電纜編(bian)號的(de)(de)含義(yi)是什么?

答(da):電纜(lan)(lan)(lan)清冊是施(shi)放(fang)電纜(lan)(lan)(lan)和指導施(shi)工的依據,運行維護的檔案資料。應(ying)(ying)列入(ru)每根電纜(lan)(lan)(lan)的編號、起始點、型號、規(gui)格、長度(du),并分類(lei)統計(ji)出總長度(du),控(kong)纜(lan)(lan)(lan)還應(ying)(ying)列出每根電纜(lan)(lan)(lan)的備用芯。

電纜(lan)(lan)編號是識別電纜(lan)(lan)的標志,故(gu)要求全廠編號不(bu)重復,并且有一(yi)定(ding)的含義和規律,能(neng)表達電纜(lan)(lan)的特(te)征。

61、電纜目前采用的(de)敷設(she)方(fang)法可分為幾類?

答:(1)人(ren)工敷設(she),即(ji)采用(yong)人(ren)海戰術(shu),在一人(ren)或多(duo)人(ren)協調指揮下,按規定進行敷設(she);

(2)機械化敷設,即采用滾(gun)輪、牽引器、輸送(song)機,通過一同(tong)步(bu)電源進行控制,比較安全(quan);

(3)人(ren)工和機械(xie)相(xiang)結(jie)合,有些現場由于轉彎較多,施(shi)工難度(du)大,全用(yong)機械(xie)較困(kun)難,所以采用(yong)此法。

62、控制(zhi)二次回(hui)路接(jie)線(xian)應符合哪(na)些要求?

答:(1)按圖施工接線正確(que);

(2)導線的電氣連接應牢固可靠(kao);

(3)盤(pan)柜內的導線不應有接頭,導線芯線應無(wu)損傷;

(4)電纜芯線端部應標明其(qi)回(hui)路編號(hao),編號(hao)應正確,字(zi)跡(ji)清晰且不易脫(tuo)色;

(5)配線應整齊、清(qing)晰、美觀,導線絕緣(yuan)應良好、無損;

(6)每個接(jie)線(xian)端子的每側接(jie)線(xian)宜為一根,最多不(bu)得超過兩根。

63、電纜排管有何要求?

答:(1)排管頂部至地(di)面(mian)距離(li),在(zai)廠房(fang)內為0.2m,人行道(dao)下為0.5m,一般地(di)區(qu)為0.7m;

(2)在變更方向及分支(zhi)處均應(ying)裝置排管井坑,長度超過(guo)30mm時也應(ying)加設井坑;

(3)井(jing)坑深度(du)不小于(yu)(yu)0.8m,人孔(kong)直徑不小于(yu)(yu)0.7mm;

(4)排管(guan)應有傾向井坑0.5%~1%的排水坡(po)度。

64、對(dui)于電(dian)纜導體連接點(dian)的電(dian)阻有何要(yao)求?

答:要求連接(jie)點的電阻小(xiao)而且穩定,連接(jie)點的電阻與相同(tong)長度、相同(tong)截面的導體之比值,對于(yu)新安裝(zhuang)的終(zhong)端頭(tou)和(he)中(zhong)間(jian)頭(tou),應不大(da)于(yu)1;對于(yu)運行(xing)中(zhong)的終(zhong)端頭(tou)和(he)中(zhong)間(jian)頭(tou)這個比值不應大(da)于(yu)1.2。

65、電纜接頭和(he)中間頭的設(she)計應滿(man)足哪些要求?

答:應滿足(zu)的要求有:

(1)耐壓(ya)強(qiang)度(du)高,導體連(lian)接好;

(2)機械(xie)強度大,介質損失小;

(3)結構簡(jian)單(dan),密封性強。

66、什么是(shi)電纜故障?有幾種(zhong)常見的類型?

答:電纜故(gu)(gu)障(zhang)(zhang)(zhang)(zhang)是(shi)指(zhi)電纜在預(yu)防性(xing)試驗時發生絕(jue)緣擊穿(chuan)或在運(yun)行中,因絕(jue)緣擊穿(chuan)、導線燒(shao)斷等而(er)迫(po)使電纜線路停(ting)電的故(gu)(gu)障(zhang)(zhang)(zhang)(zhang)。常見的故(gu)(gu)障(zhang)(zhang)(zhang)(zhang)有接地(di)故(gu)(gu)障(zhang)(zhang)(zhang)(zhang)、短路故(gu)(gu)障(zhang)(zhang)(zhang)(zhang)、斷線故(gu)(gu)障(zhang)(zhang)(zhang)(zhang)、閃絡性(xing)故(gu)(gu)障(zhang)(zhang)(zhang)(zhang)和混合型故(gu)(gu)障(zhang)(zhang)(zhang)(zhang)等。

67、如何處理電纜(lan)線路的單相接(jie)地故障?

答:電(dian)纜(lan)線路(lu)單相接地故(gu)障(zhang)(zhang)一般來說,電(dian)纜(lan)導(dao)體的(de)(de)損(sun)傷(shang)只是局部的(de)(de),如果(guo)屬于機械損(sun)傷(shang),而故(gu)障(zhang)(zhang)點附近的(de)(de)土壤又(you)較干燥時,一般可(ke)進行局部修理,加添一只假接頭,即不將(jiang)電(dian)纜(lan)芯(xin)鋸斷,僅將(jiang)故(gu)障(zhang)(zhang)點絕(jue)緣加強后密封即可(ke)。

68、電(dian)力電(dian)纜(lan)在敷設前應進行哪些試驗(yan)和檢查?

答:敷設(she)前應檢查電纜(lan)的型號、規格及長度是否(fou)(fou)符合要(yao)求(qiu),是否(fou)(fou)有外力損傷,低(di)壓(ya)電纜(lan)用1000V兆歐表遙測絕緣電阻(zu),阻(zu)值一般(ban)不(bu)低(di)于10MΩ,高壓(ya)電纜(lan)用2500V兆歐表搖測阻(zu)值一般(ban)不(bu)抵于400MΩ。

69、主廠房內敷設電纜時一般應注意什(shen)么?

答:在主廠房內敷設電(dian)纜時一(yi)般應注意:

(1)凡引至(zhi)集控室的控制電纜宜架空敷設;

(2)6KV電纜宜用隧道或排管(guan)敷(fu)(fu)設,地(di)下水位高處亦可架空或用排管(guan)敷(fu)(fu)設;

(3)380V電(dian)纜當(dang)(dang)兩端電(dian)纜在(zai)零(ling)米時(shi)宜用隧道、溝或(huo)排管(guan),當(dang)(dang)一端設(she)備在(zai)上(shang)、一端在(zai)下(xia)(xia)時(shi),可(ke)部分架空敷設(she),當(dang)(dang)地(di)下(xia)(xia)水位(wei)較高時(shi),宜架空。

70、電力電纜的內屏(ping)蔽層與外屏(ping)蔽層各在什(shen)么部位(wei)?采用什(shen)么材料?有何作用?

答:為(wei)了使絕緣(yuan)層(ceng)(ceng)和電(dian)纜導(dao)體(ti)(ti)有(you)較(jiao)好的(de)接觸,消(xiao)除導(dao)體(ti)(ti)表(biao)面的(de)不光滑引起的(de)導(dao)體(ti)(ti)表(biao)面電(dian)場(chang)強度的(de)增加,一般(ban)(ban)在(zai)導(dao)體(ti)(ti)表(biao)面包(bao)有(you)金(jin)屬化(hua)紙(zhi)或(huo)(huo)半導(dao)體(ti)(ti)紙(zhi)帶(dai)的(de)內屏蔽層(ceng)(ceng)。為(wei)了使絕緣(yuan)層(ceng)(ceng)和金(jin)屬護套有(you)較(jiao)好的(de)接觸,一般(ban)(ban)在(zai)絕緣(yuan)層(ceng)(ceng)外(wai)表(biao)面包(bao)有(you)外(wai)層(ceng)(ceng)屏蔽層(ceng)(ceng)。外(wai)屏層(ceng)(ceng)與(yu)內屏層(ceng)(ceng)的(de)材(cai)料相(xiang)同,有(you)時還外(wai)扎銅(tong)帶(dai)或(huo)(huo)編(bian)織銅(tong)絲帶(dai)。

71、簡述環氧樹脂復(fu)合(he)物的構成(cheng)及性能。

答:環氧(yang)樹(shu)脂復合物由環氧(yang)樹(shu)脂加入硬化劑、填充劑增(zeng)韌劑和稀釋劑組成。具有以下性能:

(1)有足(zu)夠的機械(xie)強度;

(2)電(dian)氣性能(neng)優良;

(3)電氣性能(neng)穩定(ding);

(4)與有色金屬(shu)有足夠(gou)的(de)黏(nian)附(fu)力;

(5)耐腐蝕性好;

(6)戶外使用(yong)時,耐(nai)雨、耐(nai)光、耐(nai)濕熱(re)。

72、單芯電纜護(hu)套(tao)一端接(jie)地方(fang)式中為什么(me)必(bi)須安(an)裝一條沿電纜平(ping)行敷設的回流線?

答:在金(jin)屬護套一(yi)端接地(di)(di)的(de)(de)電(dian)纜(lan)線路中,為確保護套中的(de)(de)感(gan)(gan)應電(dian)壓(ya)不超過允許標準,必須安裝一(yi)條沿電(dian)纜(lan)線路平(ping)行敷設(she)的(de)(de)導(dao)體,且導(dao)體的(de)(de)兩端接地(di)(di),這種(zhong)導(dao)體稱為回流(liu)(liu)(liu)線。當(dang)發生單相接地(di)(di)故障(zhang)時,接地(di)(di)短(duan)路電(dian)流(liu)(liu)(liu)可以通(tong)過回流(liu)(liu)(liu)線流(liu)(liu)(liu)回系統(tong)中心(xin)點(dian),由(you)于通(tong)過回流(liu)(liu)(liu)線的(de)(de)接地(di)(di)電(dian)流(liu)(liu)(liu)產生的(de)(de)磁通(tong)抵(di)消(xiao)了一(yi)部分電(dian)纜(lan)導(dao)線接地(di)(di)電(dian)流(liu)(liu)(liu)所(suo)產生的(de)(de)磁通(tong),因而可降低短(duan)路故障(zhang)時護套的(de)(de)感(gan)(gan)應電(dian)壓(ya)。

73、電纜工程可(ke)劃分為幾個(ge)項目(mu)?

答:(1)工(gong)(gong)地(di)運(yun)輸:包括工(gong)(gong)程材料(liao)從倉庫到施(shi)工(gong)(gong)點的裝卸(xie)、運(yun)輸和空(kong)車回程。

(2)地方(fang)工程:包(bao)括路面(mian)開(kai)挖(wa)、隧、溝(gou)道施工等。

(3)敷(fu)(fu)設(she)工程(cheng):包括敷(fu)(fu)設(she)、中間頭(tou)制作(zuo)、掀(xian)蓋板、埋管、校潮、牽引頭(tou)制作(zuo)等。

(4)兩端(duan)工程:包括(kuo)支(zhi)、吊(diao)橋架和其(qi)基礎的制作安(an)裝(zhuang),終端(duan)頭制作,油壓力和信號裝(zhuang)置的安(an)裝(zhuang),名(ming)種電氣(qi)性能測試(shi)等。

(5)塞(sai)止工(gong)程:包括充油電(dian)纜塞(sai)止頭制作,供油箱、自動排水及信(xin)號裝置的安(an)裝等。

(6)接地工(gong)程:包(bao)括(kuo)絕緣(yuan)接頭、換位箱(xiang)、保護器、接地箱(xiang)安裝等。

74、電纜(lan)線(xian)路的驗收應進(jin)行(xing)哪些檢(jian)查?

答:(1)電纜規格應(ying)符合規定,排(pai)列應(ying)整齊,無(wu)損傷,標(biao)牌齊全(quan)、正(zheng)確、清晰;

(2)電纜的(de)固定彎曲半徑(jing)、有關(guan)距離及單芯電力(li)電纜的(de)金屬護層的(de)接線應符合(he)要(yao)求;

(3)電(dian)纜終(zhong)端、中間頭不滲漏油(you),安裝牢(lao)固,充(chong)油(you)電(dian)纜油(you)壓及表計整定值應符合要求;

(4)接地良(liang)好;

(5)電纜終端相色(se)正確,支架等的金屬部件(jian)油漆完整;

(6)電纜溝及隧道內、橋架上應(ying)無雜(za)物,蓋板齊全。

75、電纜線(xian)路正(zheng)序阻抗測量過程中有什(shen)么要求(qiu)?

答:電纜導(dao)體的交流(liu)電阻和電纜三相同(tong)感(gan)抗(kang)的相量和稱為正序阻抗(kang)。

電(dian)(dian)纜(lan)線路的(de)(de)正序阻抗一般可在電(dian)(dian)纜(lan)盤上(shang)(shang)直接(jie)測(ce)(ce)量(liang),測(ce)(ce)量(liang)時一般使(shi)用(yong)(yong)較低(di)的(de)(de)電(dian)(dian)壓(ya),因此,需要用(yong)(yong)降壓(ya)變壓(ya)器進行降壓(ya),降壓(ya)器采用(yong)(yong)星形(xing)接(jie)線,容(rong)量(liang)一般為10kVA以上(shang)(shang),有(you)較廣的(de)(de)電(dian)(dian)壓(ya)調節范(fan)圍,測(ce)(ce)量(liang)時交流(liu)電(dian)(dian)源應比(bi)較穩定,以保證(zheng)測(ce)(ce)量(liang)時電(dian)(dian)流(liu)達到(dao)規定的(de)(de)要求,實際電(dian)(dian)壓(ya)表(biao)的(de)(de)讀數(shu)值必須是電(dian)(dian)纜(lan)端(duan)的(de)(de)電(dian)(dian)壓(ya),試驗電(dian)(dian)流(liu)更好 接(jie)近電(dian)(dian)纜(lan)長期(qi)允許載流(liu)量(liang),測(ce)(ce)讀各表(biao)計的(de)(de)數(shu)值時,合上(shang)(shang)電(dian)(dian)流(liu)后同時讀取三(san)個表(biao)的(de)(de)數(shu)值。

76、根(gen)據《電業生產安全規定(ding)》,電氣(qi)工作人員(yuan)必須具備的條件是什么?

答(da):必須具備下列條件:

(1)經醫(yi)生鑒定身體(ti)健康,無妨礙工作(zuo)的病癥;

(2)具(ju)備必要(yao)的(de)電氣知(zhi)識,按其職務和工(gong)作(zuo)性質掌握相關的(de)規程、專業(ye)技術及安全操作(zuo)技術,并(bing)經考試合格;

(3)熟練掌握觸(chu)電急救方法。

77、電纜(lan)在運(yun)輸裝卸過(guo)程中應注意(yi)什(shen)么?

答:(1)在運輸裝卸過程中(zhong),不應使電纜(lan)及電纜(lan)盤受到(dao)損(sun)傷,嚴(yan)禁將電纜(lan)盤直接由車上推(tui)下,電纜(lan)般不應平放運輸,平放貯存。

(2)運輸或滾動電(dian)纜(lan)盤(pan)前,必須(xu)保證電(dian)纜(lan)盤(pan)牢固,電(dian)纜(lan)繞緊、充(chong)油(you)(you)電(dian)纜(lan)至壓(ya)力油(you)(you)箱(xiang)間(jian)的油(you)(you)管應(ying)(ying)固定,不得(de)損傷,壓(ya)力油(you)(you)箱(xiang)應(ying)(ying)牢固,壓(ya)力指示應(ying)(ying)符(fu)合要求(qiu)。

78、電纜防火(huo)有(you)哪些措施?

答:(1)采用(yong)阻燃(ran)電纜;

(2)采用防火電纜(lan)托架;

(3)采用(yong)防(fang)火涂料(liao);

(4)電纜隧道、夾層出口等(deng)處設置防火(huo)隔(ge)墻、防火(huo)擋板;

(5)架空電纜應避開油(you)管(guan)道(dao)、防(fang)爆門,否則應有要取局部穿管(guan)或隔熱防(fang)火措施。

79、選擇電力電纜(lan)的(de)截面應從(cong)哪幾個方(fang)面考慮?

答:應(ying)考慮(lv)如下幾個方(fang)面:

(1)電(dian)纜長(chang)期允許通過的工作(zuo)電(dian)流;

(2)一旦短(duan)路(lu)時的熱穩定性;

(3)線路上的電壓降不(bu)能超出允許(xu)工(gong)作范(fan)圍。

80、電力電纜和(he)架空(kong)線比(bi)較有(you)哪些優點?

答:(1)運行可(ke)靠,由于安(an)裝在(zai)地下等(deng)隱蔽處,受外力破壞小,發生故障的(de)機會較少,供電安(an)全,不會給人身造(zao)成危害;

(2)維護工(gong)作量小,不(bu)需頻繁的(de)巡檢;

(3)不需架設桿(gan)塔;

(4)有助(zhu)于提(ti)高功率因數。