紅崗電線電纜常識80問答?沈陽凱鵬電纜廠提供

來源(yuan):常見問題 閱讀:156983 發布時間:2023-03-07

1、常用的電線(xian)、電纜按用途(tu)分有(you)哪(na)些(xie)種類(lei)?

答:按(an)用途可分(fen)為裸(luo)導線(xian)、絕緣電(dian)(dian)線(xian)、耐熱電(dian)(dian)線(xian)、屏蔽(bi)電(dian)(dian)線(xian)、電(dian)(dian)力(li)電(dian)(dian)纜、控(kong)制電(dian)(dian)纜、通信電(dian)(dian)纜、射頻電(dian)(dian)纜等。


2、絕緣(yuan)電(dian)線有哪幾種?

答:常有的絕緣(yuan)(yuan)電(dian)線(xian)(xian)(xian)有以下(xia)幾種:聚(ju)(ju)氯乙(yi)烯(xi)(xi)絕緣(yuan)(yuan)電(dian)線(xian)(xian)(xian)、聚(ju)(ju)氯乙(yi)烯(xi)(xi)絕緣(yuan)(yuan)軟(ruan)線(xian)(xian)(xian)、丁腈聚(ju)(ju)氯乙(yi)烯(xi)(xi)混合(he)物絕緣(yuan)(yuan)軟(ruan)線(xian)(xian)(xian)、橡皮絕緣(yuan)(yuan)電(dian)線(xian)(xian)(xian)、農(nong)用地下(xia)直埋(mai)鋁芯塑料絕緣(yuan)(yuan)電(dian)線(xian)(xian)(xian)、橡皮絕緣(yuan)(yuan)棉紗紡織軟(ruan)線(xian)(xian)(xian)、聚(ju)(ju)氯乙(yi)烯(xi)(xi)絕緣(yuan)(yuan)尼龍護套電(dian)線(xian)(xian)(xian)、電(dian)力和照明用聚(ju)(ju)氯乙(yi)烯(xi)(xi)絕緣(yuan)(yuan)軟(ruan)線(xian)(xian)(xian)等。


3、電纜橋架適合(he)于何種場合(he)?

答:電(dian)(dian)(dian)(dian)纜橋(qiao)架適用(yong)于一(yi)般工礦企業室內外(wai)架空(kong)敷設電(dian)(dian)(dian)(dian)力電(dian)(dian)(dian)(dian)纜、控制電(dian)(dian)(dian)(dian)纜,亦可用(yong)于電(dian)(dian)(dian)(dian)信、廣播(bo)電(dian)(dian)(dian)(dian)視(shi)等部門在室內外(wai)架設。


4、電纜(lan)附件有哪些?

答:常(chang)用的電(dian)附(fu)件有(you)電(dian)纜(lan)終端接線(xian)(xian)盒(he)、電(dian)纜(lan)中間接線(xian)(xian)盒(he)、連接管及接線(xian)(xian)端子、鋼板(ban)接線(xian)(xian)槽、電(dian)纜(lan)橋架等(deng)。


5、什么叫電纜中間(jian)接(jie)頭(tou)?

答:連接電(dian)纜(lan)(lan)與電(dian)纜(lan)(lan)的(de)導體、絕緣屏蔽層和保護層,以(yi)使電(dian)纜(lan)(lan)線路連接的(de)裝置(zhi),稱為電(dian)纜(lan)(lan)中間接頭。


6、什么叫電氣(qi)主接線?

答:電氣主接(jie)線(xian)是發(fa)電廠、變電所中主要(yao)電氣設備(bei)和(he)母(mu)線(xian)的連接(jie)方式(shi),包(bao)括主母(mu)線(xian)和(he)廠用電系統按一(yi)定的功能要(yao)求的連接(jie)方式(shi)。


7、在選(xuan)擇電力電纜的(de)截面(mian)時,應遵(zun)照哪些規定?

答(da):電(dian)力電(dian)纜(lan)的(de)選擇應遵照以下原則:(1)電(dian)纜(lan)的(de)額(e)定電(dian)壓要(yao)大(da)于或(huo)(huo)等于安裝點供電(dian)系統的(de)額(e)定電(dian)壓;(2)電(dian)纜(lan)持續容許電(dian)流應等于或(huo)(huo)大(da)于供電(dian)負(fu)載的(de)更大(da) 持續電(dian)流;(3)線芯截面(mian)要(yao)滿足供電(dian)系統短路時的(de)穩定性的(de)要(yao)求(qiu)(qiu);(4)根據電(dian)纜(lan)長(chang)度驗算(suan)電(dian)壓降是否符合要(yao)求(qiu)(qiu);(5)線路末端(duan)的(de)最小短路電(dian)流應能使(shi)保護(hu)裝置可靠的(de)動作。


8、交聯聚(ju)乙烯電纜和油紙電纜比較有哪些優點?

答:(1)易安(an)裝,因為它允許最小(xiao)彎曲(qu)半徑小(xiao)、且重量輕;(2)不受線路落差*;(3)熱性能好(hao),允許工(gong)作溫度高(gao)(gao)、傳輸容(rong)量大;(4)電纜附件簡單,均為干(gan)式結構;(5)運行維護簡單,無漏油問題;(6)價格較低;(7)可(ke)靠性高(gao)(gao)、故(gu)障率(lv)低;(8)制造工(gong)序少(shao)、工(gong)藝簡單,經濟效益(yi)顯(xian)著。


9、固定交流單芯(xin)電纜的夾具(ju)有(you)什(shen)(shen)么要求?為什(shen)(shen)么?

答:夾具(ju)應無鐵(tie)(tie)(tie)件(jian)構(gou)成(cheng)閉(bi)合(he)磁路(lu),這是因(yin)為當(dang)電(dian)纜線(xian)芯通過電(dian)流時,在其周圍產(chan)生磁力線(xian),磁力線(xian)與通過線(xian)芯的電(dian)流大小成(cheng)正比,若(ruo)使(shi)(shi)(shi)用鐵(tie)(tie)(tie)件(jian)等導磁材(cai)料,根(gen)據電(dian)磁感應可知,將在鐵(tie)(tie)(tie)件(jian)中產(chan)生渦流使(shi)(shi)(shi)電(dian)纜發熱,甚至燒壞電(dian)纜。所以不可使(shi)(shi)(shi)用鐵(tie)(tie)(tie)件(jian)作單芯交流電(dian)纜的固(gu)定(ding)夾具(ju)。


10、以下的(de)(de)熱縮電纜頭的(de)(de)附件的(de)(de)更大(da) 特點和優點是什么?

答:熱縮(suo)附(fu)件的(de)更大 特點是用應(ying)力(li)管(guan)代替傳統(tong)的(de)應(ying)力(li)錐,它不僅簡化了施(shi)工工藝,還縮(suo)小了接頭(tou)的(de)終端的(de)尺寸,安裝方便,省時(shi)省工,性能優(you)(you)越,節(jie)約金屬。熱縮(suo)電(dian)纜附(fu)件集灌注式(shi)和干(gan)包式(shi)為一體,集合了這兩種附(fu)件的(de)優(you)(you)點。


11、電纜敷設前應進行哪些檢查工(gong)作?

答(da):(1)支架應齊全(quan)、油(you)(you)漆(qi)完整。(2)電(dian)(dian)纜(lan)型(xing)號、電(dian)(dian)壓(ya)、規格符(fu)合設計。(3)電(dian)(dian)纜(lan)絕(jue)緣良好(hao),當對(dui)油(you)(you)紙電(dian)(dian)纜(lan)的(de)(de)密封有懷疑(yi)時,應進行受潮判斷;直(zhi)埋電(dian)(dian)纜(lan)與小底電(dian)(dian)纜(lan)應經直(zhi)流耐壓(ya)試難合格;充油(you)(you)電(dian)(dian)纜(lan)的(de)(de)油(you)(you)樣應試驗合格。(4)充油(you)(you)電(dian)(dian)纜(lan)的(de)(de)油(you)(you)壓(ya)不宜低于(yu)1.47MPa。


11、交聯熱收縮(suo)電纜(lan)附件有哪些優(you)點?

答:這是一種新(xin)型(xing)材(cai)料,它與(yu)現在其(qi)他類型(xing)附件比較具(ju)有電氣性(xing)能優越、體積小、質(zhi)量小、安裝簡便、材(cai)料配套(tao)等優點(dian),另外還(huan)具(ju)有耐氣候(hou)、抗污穢性(xing)、阻燃自熄(xi)等能力(li)。


12、對油(you)紙絕緣電(dian)(dian)力電(dian)(dian)纜密(mi)封有懷疑時,如何用較(jiao)簡單的辦法檢查電(dian)(dian)纜絕緣紙是否(fou)受潮(chao)?

答:把(ba)電(dian)纜絕緣紙點燃(ran)或放入150℃左右的電(dian)纜油(you)中檢查,無“嘶嘶”聲或白(bai)色泡沫(mo)出現,說明未(wei)受潮(chao)。


13、電(dian)纜標志牌應注明(ming)什么(me)內容?編(bian)寫有(you)何要求?

答:標(biao)志牌上應(ying)注(zhu)明電纜(lan)線(xian)路設計編號(hao)、電纜(lan)型號(hao)、規格及始(shi)點,并聯使用的(de)電纜(lan)應(ying)有順序號(hao)。要求字跡清晰、不易脫落。


14、直埋電纜的方位標(biao)志應設置(zhi)在哪些位置(zhi)?

答:在電(dian)纜兩端,電(dian)纜直線段(duan)50~100m處(chu)電(dian)纜接頭幾電(dian)纜改變方(fang)向的彎角(jiao)處(chu)。


15、制作電纜(lan)接(jie)頭用的黃臘綢帶(dai)、黑(hei)玻璃漆帶(dai)、無堿玻璃絲(si)帶(dai)等,施(shi)工前如何進行排(pai)潮處(chu)理(li)?

答:(1)恒溫(wen)干(gan)燥法(fa):將絕緣帶(dai)(dai)卷成直(zhi)徑為25~30mm小卷,放入110~120℃恒溫(wen)干(gan)燥箱內(nei)烘(hong)4~5h,冷卻干(gan)取(qu)出,放入干(gan)燥的(de)密(mi)封筒內(nei)。(2)油(you)浸排潮法(fa):將絕緣帶(dai)(dai)小卷放入恒溫(wen)在120~130℃的(de)電纜油(you)中,離(li)鍋底保持30mm距離(li),經(jing)一(yi)定時間(jian)后(hou)油(you)面不再產生泡沫后(hou)取(qu)出,裝(zhuang)入貯(zhu)有電纜油(you)的(de)桶(tong)中,油(you)位應超過所(suo)有裝(zhuang)入的(de)物體并將其密(mi)封。


16、電纜外(wai)護層的作用是什么?

答:保(bao)護(hu)內護(hu)層(ceng)不受機械(xie)損傷和化學腐蝕,增強機械(xie)強度。


17、室(shi)外電纜溝(gou)應符(fu)合哪些要(yao)求?

答:電纜(lan)溝上部應比(bi)地(di)面稍高(gao),加蓋用混(hun)凝土制作的(de)蓋板,電纜(lan)應平(ping)敷在支(zhi)架上,有良好的(de)排水管。


18、電纜內護層的作用是什么(me)?

答;使絕(jue)緣層不(bu)會與水、空(kong)氣或其他物體接觸(chu),防(fang)止絕(jue)緣受潮和絕(jue)緣層不(bu)受機械傷害。


19、使用鋼絲(si)鉗時(shi)應注(zhu)意(yi)些什么?

答(da):使用前(qian),一定(ding)要檢查絕緣柄的絕緣是否完(wan)好無損,使用時不可用鋼絲鉗剪切超過(guo)規格所允許的金屬線材,并(bing)禁止(zhi)用鋼絲鉗代替(ti)錘子敲打工具,以免損壞。


20、什(shen)么叫絕緣強(qiang)度?

答:絕(jue)(jue)緣(yuan)物質在電場中,當電場強度(du)增大(da)到某一極(ji)限時就(jiu)會被(bei)擊穿,這個導(dao)致絕(jue)(jue)緣(yuan)擊穿的電場強度(du)稱為絕(jue)(jue)緣(yuan)強度(du)。


22、對電(dian)纜導體連接點的機械強度有何要求?

答:連接(jie)點的(de)機械(xie)強(qiang)度,一般低(di)于(yu)電纜導體(ti)本(ben)身的(de)抗拉(la)強(qiang)度,對(dui)于(yu)固定敷(fu)設的(de)電力電纜,其(qi)連接(jie)點的(de)抗拉(la)強(qiang)度要(yao)求不低(di)于(yu)導體(ti)本(ben)身抗拉(la)強(qiang)度的(de)60%。


23、電力電纜的絕緣層材料應(ying)具備哪(na)些主要(yao)性能?

答;應(ying)具備下列主要性(xing)能:(1)高的(de)(de)擊穿強度(du);(2)低的(de)(de)介質損耗;(3)相(xiang)當高的(de)(de)絕緣電阻;(4)優良的(de)(de)耐(nai)放電性(xing)能;(5)具有一定的(de)(de)柔軟性(xing)和(he)機械強度(du);(6)絕緣性(xing)能長期穩定。


24、機械敷設電纜時,牽(qian)引(yin)強(qiang)度有何規定?

答:對于銅芯電(dian)纜(lan)(lan)(lan),當(dang)牽(qian)引(yin)頭(tou)部(bu)時(shi),允(yun)許(xu)(xu)牽(qian)引(yin)強(qiang)(qiang)度為(wei)(wei)70N/cm;對于鋁芯電(dian)纜(lan)(lan)(lan),當(dang)牽(qian)引(yin)頭(tou)部(bu)時(shi),允(yun)許(xu)(xu)牽(qian)引(yin)強(qiang)(qiang)度為(wei)(wei)40N/cm;若利用鋼絲(si)網套牽(qian)引(yin)時(shi),鉛護套電(dian)纜(lan)(lan)(lan)允(yun)許(xu)(xu)強(qiang)(qiang)度為(wei)(wei)10N/cm;鉛護套電(dian)纜(lan)(lan)(lan)為(wei)(wei)40N/cm。


25、對電纜保(bao)護管有何規定?

答:(1)電纜(lan)需要穿保護(hu)管(guan)(guan)(guan)敷設時(shi),管(guan)(guan)(guan)子內(nei)徑不(bu)(bu)應(ying)小(xiao)于電纜(lan)外徑的1.5倍,混凝土管(guan)(guan)(guan)、陶土管(guan)(guan)(guan)、石棉、水泥管(guan)(guan)(guan)的內(nei)徑不(bu)(bu)應(ying)小(xiao)于100mm;

(2)電纜管的彎曲(qu)半徑(jing)應符合所(suo)穿入電纜彎曲(qu)半徑(jing)的規定;

(3)每根管子最多(duo)不應(ying)超過三(san)個彎頭,直角彎不應(ying)多(duo)于2個。

26、如何測(ce)量(liang)電纜(lan)護套(tao)的外(wai)徑(jing)?

答(da):在(zai)護(hu)套圓周上均勻(yun)分布的五點處,測量護(hu)套外(wai)徑和其平(ping)均值,其平(ping)均外(wai)徑既為護(hu)套的外(wai)徑。

27、不同截面的銅芯電纜如(ru)何(he)連接?

答:不(bu)(bu)同截面的銅芯電纜連接,可(ke)采(cai)用開口弱背銅接管(guan),以錫(xi)焊法(fa)(fa)連接,也可(ke)用純銅棒按(an)不(bu)(bu)同的截面要求連接成銅接管(guan),以壓接法(fa)(fa)連接。

28、簡述10KV交聯電纜熱縮(suo)式制作戶(hu)內終端頭(tou)的過程?

答;(1)準備(bei)(bei)階段:檢(jian)查熱縮電(dian)纜(lan)附件是否齊(qi)備(bei)(bei),型號(hao)是否相(xiang)配(pei),檢(jian)查并確認(ren)電(dian)纜(lan)有(you)無潮(chao)氣(qi)后(hou),檢(jian)查電(dian)纜(lan)。

(2)切除多余電(dian)纜(lan)(lan),根據現場(chang)情(qing)況決定(ding)電(dian)纜(lan)(lan)長度(du)。

(3)剝除護(hu)層(ceng)。

(4)焊(han)接接地(di)(di)線,將接地(di)(di)線焊(han)接在鋼帶上(shang)。

(5)填(tian)充三(san)叉口(kou)及繞包密封膠。

(6)安裝三(san)芯分支護(hu)套(tao)(tao),將(jiang)護(hu)套(tao)(tao)套(tao)(tao)入(ru)根(gen)部(bu)(bu),從(cong)中部(bu)(bu)開始(shi)收縮,先往根(gen)部(bu)(bu),再往指部(bu)(bu)。

(7)剝銅 帶和外(wai)半(ban)導(dao)電層(ceng),剝切(qie)三芯(xin)分支套口20mm以上的(de)銅帶,嚴禁損傷主絕緣,清除(chu)干(gan)凈(jing)半(ban)導(dao)電層(ceng)。

(8)安(an)裝應力(li)管,管口端部(bu)分支套(tao)對接后熱縮。

(9)安裝接線端子(zi)。

(10)安裝絕緣管。

(11)安裝密封管。

(12)核相(xiang)后安(an)裝(zhuang)相(xiang)色管。

29、戶內、戶外預(yu)制式終端安裝步驟(zou)有哪些?

答:(1) 將(jiang)電纜(lan)按(an)預(yu)定位置就(jiu)位、固(gu)定、清潔表面,參(can)照說明書剝除外護套(tao),如有特殊需要,外護套(tao)剝切長度可調整,分(fen)別由銅(tong)帶(dai)、外護套(tao)鎧(kai)裝引出2組地線。

(2) 由(you)外護套口向上(shang)量取(qu)需(xu)要尺寸,切除多余電纜,套入熱縮(suo)三指套至三叉口根部由(you)中間(jian)加(jia)熱收縮(suo),由(you)指套上(shang)口向上(shang)量取(qu)規定尺寸(35kv為350~380mm)。去掉(diao)多余銅(tong)帶(保留20mm),再保留半導體預(yu)定位置,壓(ya)接(jie)出線端(duan)子(zi)密封。

30、電線電纜的應用主(zhu)要(yao)分為三大類 :

(1)、電力系(xi)統

電(dian)(dian)(dian)(dian)力系統采用的電(dian)(dian)(dian)(dian)線(xian)電(dian)(dian)(dian)(dian)纜(lan)(lan)產(chan)品主要有架空裸電(dian)(dian)(dian)(dian)線(xian)、匯流排(pai)(母線(xian))、電(dian)(dian)(dian)(dian)力電(dian)(dian)(dian)(dian)纜(lan)(lan)(塑料線(xian)纜(lan)(lan)、油(you)紙(zhi)力纜(lan)(lan)(基本被塑料電(dian)(dian)(dian)(dian)力電(dian)(dian)(dian)(dian)纜(lan)(lan)代替)、橡套線(xian)纜(lan)(lan)、架空絕緣電(dian)(dian)(dian)(dian)纜(lan)(lan))、分(fen)支電(dian)(dian)(dian)(dian)纜(lan)(lan)(取(qu)代部分(fen)母線(xian))、電(dian)(dian)(dian)(dian)磁線(xian)以及電(dian)(dian)(dian)(dian)力設備用電(dian)(dian)(dian)(dian)氣裝備電(dian)(dian)(dian)(dian)線(xian)電(dian)(dian)(dian)(dian)纜(lan)(lan)等。

(2)、信息傳輸系統

用于(yu)信息傳輸系統(tong)的(de)電(dian)(dian)(dian)線電(dian)(dian)(dian)纜(lan)(lan)(lan)主要(yao)有市話電(dian)(dian)(dian)纜(lan)(lan)(lan)、電(dian)(dian)(dian)視電(dian)(dian)(dian)纜(lan)(lan)(lan)、電(dian)(dian)(dian)子(zi)線纜(lan)(lan)(lan)、射頻電(dian)(dian)(dian)纜(lan)(lan)(lan)、光纖纜(lan)(lan)(lan)、數據電(dian)(dian)(dian)纜(lan)(lan)(lan)、電(dian)(dian)(dian)磁線、電(dian)(dian)(dian)力通訊或其他復合電(dian)(dian)(dian)纜(lan)(lan)(lan)等。

(3)、機械設備、儀器儀表(biao)系統

此部(bu)分除架空(kong)裸電(dian)線(xian)外幾乎其(qi)他所有產品均有應用,但主要是電(dian)力電(dian)纜、電(dian)磁(ci)線(xian)、數(shu)據電(dian)纜、儀(yi)器儀(yi)表(biao)線(xian)纜等。

31、電(dian)線電(dian)纜產(chan)品主要分(fen)為五大類:

(1)、裸電線及裸導體制品(pin)(pin) 本類產品(pin)(pin)的主要特征(zheng)是:純的導體金屬(shu),無絕緣(yuan)及護套層(ceng),如(ru)(ru)鋼芯鋁絞線、銅鋁匯流排(pai)、電力(li)機車線等(deng);加(jia)工工藝主要是壓力(li)加(jia)工,如(ru)(ru)熔煉(lian)、壓延(yan)、拉制、絞合/緊壓絞合等(deng);產品(pin)(pin)主要用在城(cheng)郊、農村、用戶主線、開關柜(ju)等(deng)。

(2)、電(dian)力(li)電(dian)纜(lan)本類產品主要特征(zheng)是(shi):在導體外擠(ji)(繞)包絕緣(yuan)層,如架空絕緣(yuan)電(dian)纜(lan),或幾芯絞(jiao)合(對應電(dian)力(li)系統的(de)相線、零線和地線),如二芯以上架空絕緣(yuan)電(dian)纜(lan),或再增加(jia)護套(tao)層,如塑料/橡套(tao)電(dian)線電(dian)纜(lan)。主要的(de)工(gong)藝(yi)技術(shu)有拉制、絞(jiao)合、絕緣(yuan)擠(ji)出(繞包)、成纜(lan)、鎧裝、護層擠(ji)出等,各種產品的(de)不(bu)同工(gong)序(xu)組合有一(yi)定區別(bie)。

產品主(zhu)要用在發、配、輸(shu)、變(bian)、供電(dian)(dian)線路(lu)中的強電(dian)(dian)電(dian)(dian)能(neng)傳輸(shu),通過的電(dian)(dian)流(liu)大(幾十(shi)安(an)至(zhi)(zhi)幾千安(an))、電(dian)(dian)壓高(220V至(zhi)(zhi)500kV及以上)。

(3)、電氣裝備用(yong)(yong)電線(xian)(xian)電纜該類產(chan)品主要特征是:品種規格繁多,應用(yong)(yong)范(fan)圍廣(guang)泛,使用(yong)(yong)電壓在1kV及以下較多,面對特殊場(chang)合(he)不斷衍生新(xin)的(de)產(chan)品,如耐(nai)火線(xian)(xian)纜、阻燃線(xian)(xian)纜、低(di)(di)煙(yan)(yan)無鹵(lu)/低(di)(di)煙(yan)(yan)低(di)(di)鹵(lu)線(xian)(xian)纜、防白蟻、防老鼠線(xian)(xian)纜、耐(nai)油(you)/耐(nai)寒/耐(nai)溫/耐(nai)磨線(xian)(xian)纜、醫用(yong)(yong)/農(nong)用(yong)(yong)/礦用(yong)(yong)線(xian)(xian)纜、薄壁電線(xian)(xian)等。

(4)、通訊電纜(lan)及(ji)光纖(xian)(簡(jian)(jian)略介紹(shao))隨著近二十多年來(lai),通訊行(xing)業的飛速(su)發(fa)展,產品(pin)也有驚人的發(fa)展速(su)度。從過去的簡(jian)(jian)單的電話電報線纜(lan)發(fa)展到幾千(qian)對的話纜(lan)、同軸纜(lan)、光纜(lan)、數據(ju)電纜(lan),甚至組合通訊纜(lan)等。

該類產品結構尺寸通常(chang)較小而均勻,制造精(jing)度要(yao)求高。

(5)、電磁線(繞組線)主要(yao)用(yong)于各(ge)種電機、儀(yi)器(qi)儀(yi)表等。

電線電纜的衍生/新產(chan)品

電線(xian)電纜的(de)衍生(sheng)/新(xin)產品主要是因(yin)應(ying)(ying)用場(chang)合(he)、應(ying)(ying)用要求不同及(ji)裝備的(de)方便性和降低(di)裝備成本(ben)等(deng)的(de)要求,而(er)采用新(xin)材料、特殊材料、或(huo)改(gai)變產品結構、或(huo)提高工(gong)藝要求、或(huo)將不同品種的(de)產品進行(xing)組合(he)而(er)產生(sheng)。

采用不同材(cai)料(liao)如阻燃(ran)線纜、低煙無(wu)鹵/低煙低鹵線纜、防白蟻、防老鼠線纜、耐油/耐寒(han)/耐溫線纜等;

改變產品結構如:耐火電纜等;

提(ti)高工(gong)藝要求如:醫用線纜(lan)等(deng);

組合(he)產(chan)品(pin)如(ru):OPGW等;

方便安(an)裝(zhuang)和降低裝(zhuang)備成(cheng)本如:預制(zhi)分(fen)支電纜(lan)等。

32、母線裝置施工完,應進行哪些檢查?

答(da):應進(jin)行下(xia)列檢(jian)查:

(1)金屬構件的加(jia)工、配制、焊(han)接螺接應符合(he)規定(ding);

(2)各部螺栓、墊圈、開口(kou)銷等零部件(jian)應齊全(quan)可(ke)靠;

(3)母線配制及(ji)安裝架應符合規定,相間及(ji)對(dui)地電氣距離(li)符合要(yao)求;

(4)瓷件(jian)、鐵件(jian)及膠合處應(ying)完(wan)整(zheng),充油(you)(you)套管應(ying)無(wu)滲油(you)(you),油(you)(you)位正常;

(5)油漆完整,相(xiang)色正確,接地良好。

33、在35kv及以下電(dian)力(li)電(dian)纜接頭(tou)中(zhong),改善其護套(tao)斷開處電(dian)場分布的方法有(you)幾種(請列出五種),并簡述其方法。

答:(1)脹喇叭口:在(zai)鉛包割斷(duan)處把鉛包邊緣撬起,成喇叭狀,其邊緣應光滑、圓(yuan)整、對稱。

(2)預(yu)留統包絕(jue)緣:在鉛包切口至電纜(lan)芯線(xian)分開點之間留有(you)一段(duan)統包絕(jue)緣紙。

(3)切除半導(dao)電(dian)紙:將半導(dao)電(dian)紙切除到喇叭口(kou)以下(xia)。

(4)包繞應力錐(zhui):用絕緣(yuan)包帶(dai)和(he)導電金屬(shu)材(cai)料包成錐(zhui)形,人為地將屏(ping)蔽(bi)層(ceng)擴大(da),以改善電場(chang)分布(bu)。

(5)等電(dian)位法:對于干包型或交聯聚乙(yi)烯電(dian)纜頭(tou),在各(ge)線芯概況(kuang)絕緣表面上包一段金屬帶,并將其(qi)連接在一起。

(6)裝設(she)應(ying)力(li)控制管:對于35kv及發下熱縮管電纜(lan)頭,首先從線芯(xin)銅屏蔽(bi)(bi)層(ceng)末端方(fang)向經半(ban)導(dao)體帶(dai)至線芯(xin)絕緣概況包繞2層(ceng)半(ban)導(dao)體帶(dai),然(ran)后將相應(ying)規格折應(ying)力(li)管,套在銅屏蔽(bi)(bi)的末端處,熱縮成形。

34、電纜支架的(de)加工(gong)應符合哪些要求?

答:(1)鋼材應平直,無(wu)明(ming)顯扭曲,下料(liao)誤差應在5mm范圍內(nei),切口應無(wu)卷邊,毛剌(la);

(2)支架應焊接牢(lao)固,無顯(xian)蓍變形,各橫撐間的垂直凈距與設計偏差不應大于5mm;

(3)金(jin)屬支架(jia)必須進行防(fang)腐(fu)(fu)處(chu)(chu)理(li),位于濕熱、鹽(yan)、霧以及有化學腐(fu)(fu)蝕地區時,應根據設計作(zuo)特殊(shu)的(de)防(fang)腐(fu)(fu)處(chu)(chu)理(li)。

35、列舉(ju)出你熟悉的(de)電(dian)纜(lan)架。

答:拼焊式(shi)E型(xing)架(jia)(jia)、裝配式(shi)E型(xing)架(jia)(jia)、橋式(shi)電(dian)纜(lan)(lan)(lan)架(jia)(jia)、電(dian)纜(lan)(lan)(lan)托架(jia)(jia)、掛鉤式(shi)支架(jia)(jia)、單根(gen)電(dian)纜(lan)(lan)(lan)支架(jia)(jia)等。

36、敷設電(dian)纜應滿足哪些要求?

答:應(ying)滿足以下要求:

(1)安(an)全運行(xing)方面(mian),盡可能(neng)避免各種外來損壞,提高電纜線(xian)路的供電可靠性;

(2)經濟方面,從(cong)投資最(zui)省的方面考慮;

(3)施(shi)工方面,電纜線路的路徑(jing)必須便(bian)于旋工和投運后的維修(xiu)。

37、制作電纜終端頭或中間接頭的絕緣材料有哪(na)些?

答:有絕緣膠、絕緣帶(dai)、絕緣管(guan)、絕緣手套、絕緣樹脂(zhi)等(deng)。

38、簡(jian)述(shu)電(dian)纜頭制作的一般操作程序。答:(1)制作前的準備(bei):包括○1閱讀安裝說明書;○2察看(kan)現(xian)場;○3備(bei)料;○4電(dian)纜試潮;○5制作前測(ce)試等(deng)。

(2)接(jie)頭的制作過程:包括○1割斷多余電纜;○2電纜保護層的剝切(qie);○3導(dao)體連接(jie);○4包繞絕(jue)緣(或收縮管材);○5安裝接(jie)頭外殼;○6灌注絕(jue)緣劑;○7進(jin)行密封處理等。

(3)制作(zuo)后電氣測試。

39、電纜(lan)保(bao)護(hu)管的(de)加工應符合哪(na)些要求?

答:(1)管口應*剌(la)和尖銳(rui)楞角,管口宜(yi)做成喇(la)叭形。

(2)電纜管在彎(wan)制后,不(bu)(bu)應(ying)有(you)裂縫和顯著的凹(ao)癟(bie)現象,其彎(wan)扁程度(du)不(bu)(bu)宜(yi)大于管子外徑10%;電纜管的彎(wan)曲(qu)半(ban)徑不(bu)(bu)應(ying)小于所穿入電纜的最小允許彎(wan)曲(qu)半(ban)徑。

(3)金屬管應(ying)在外(wai)表涂防腐漆(qi)或(huo)瀝表,鍍(du)鋅(xin)管鋅(xin)層剝落處也應(ying)涂以(yi)防腐漆(qi)。

40、電(dian)(dian)纜的(de)排列符合哪(na)些要求?答:(1)電(dian)(dian)力電(dian)(dian)纜和控(kong)纜不應(ying)配置在(zai)同一層支架上(shang)。

(2)高(gao)、低(di)壓電(dian)纜(lan),強、弱電(dian)控纜(lan)應按(an)須序分層配(pei)置,一般情況宜由上而下,但在含有35kv以(yi)上高(gao)壓電(dian)纜(lan)引入柜盤(pan)時,為滿足(zu)彎曲(qu)半徑(jing),可由下面上配(pei)置。

41、電纜溝內敷設電纜的方(fang)法是什么?

答:在電(dian)纜(lan)(lan)溝(gou)(gou)內(nei)(nei)敷(fu)設(she)電(dian)纜(lan)(lan)的方法與直埋(mai)電(dian)纜(lan)(lan)的敷(fu)設(she)方法相仿,一(yi)般(ban)可將滑輪放(fang)(fang)(fang)在溝(gou)(gou)內(nei)(nei),施放(fang)(fang)(fang)完畢(bi),將電(dian)纜(lan)(lan)放(fang)(fang)(fang)于溝(gou)(gou)底或支架上(shang),并(bing)在電(dian)纜(lan)(lan)上(shang)綁扎電(dian)纜(lan)(lan)標牌。

42、電纜敷設的常用設備有哪(na)些?

答:(1)空氣壓(ya)縮機,主要用來破壞路面,為以后(hou)敷設電纜作準備(bei);

(2)電(dian)動卷揚機或電(dian)纜牽引(yin)機,主要用(yong)來拖電(dian)纜;

(3)電纜(lan)輸(shu)送機(ji),配(pei)合牽(qian)引(yin)機(ji)使用來克服巨大的摩擦力(li),減輕對電纜(lan)的損壞;

(4)電(dian)纜(lan)盤放線(xian)支架;

(5)滾輪裝置;

(6)防(fang)捻 ,減鋼絲繩(sheng)出現的扭曲;

(7)電纜盤制動裝置;

(8)張(zhang)力計。

43、電(dian)(dian)纜(lan)溝中支架安裝距(ju)離(li)的要求(qiu)如何?答:電(dian)(dian)纜(lan)固定(ding)于電(dian)(dian)纜(lan)溝和隧道的墻上,水平裝置(zhi)時,當(dang)電(dian)(dian)纜(lan)外(wai)(wai)徑等于或小于50mm時應(ying)每(mei)隔1m加(jia)(jia)(jia)一(yi)支撐;外(wai)(wai)徑大于50mm的電(dian)(dian)纜(lan)每(mei)隔0.6m加(jia)(jia)(jia)一(yi)支撐;排(pai)成三角形(xing)的單電(dian)(dian)纜(lan),每(mei)隔1m應(ying)用綁帶扎(zha)牢,垂直裝置(zhi)時,每(mei)隔1~1.5m加(jia)(jia)(jia)以固定(ding)。

44、如何處理(li)電力電纜(lan)與控(kong)制電纜(lan)在同一(yi)托(tuo)架的安(an)裝?

答(da):電力(li)電纜與控制(zhi)電纜一般不應(ying)敷設在同(tong)一托架(jia)內,當(dang)電纜較少而(er)將控纜與電力(li)電纜敷設在同(tong)一托架(jia)內時(shi),應(ying)用隔(ge)板隔(ge)開。

45、電纜隧道內如何裝設(she)接地線(xian)?

答(da):隧(sui)道和溝的(de)全(quan)長應(ying)(ying)裝設(she)連續的(de)接(jie)地(di)線(xian)(xian),接(jie)地(di)線(xian)(xian)應(ying)(ying)和所有的(de)支(zhi)架相(xiang)連,兩頭和接(jie)地(di)極連通。接(jie)地(di)線(xian)(xian)的(de)規格應(ying)(ying)符合設(she)計要(yao)求。電(dian)纜鉛(qian)包和鎧裝除了有絕緣要(yao)求外,應(ying)(ying)全(quan)部(bu)相(xiang)互連接(jie)并和接(jie)地(di)線(xian)(xian)相(xiang)連,電(dian)纜架和接(jie)地(di)線(xian)(xian)均(jun)應(ying)(ying)涂防銹漆(qi)或鍍鋅(xin)。

46、對于電纜孔洞的防火封堵有何(he)要(yao)求(qiu)?

答:對于(yu)較(jiao)大的(de)電(dian)纜貫穿孔洞(dong),如電(dian)纜貫穿樓(lou)板處等,采用防火堵(du)(du)(du)料(liao)封堵(du)(du)(du)時(shi),應根據(ju)實際情況,先在電(dian)纜表面涂(tu)四至六層防火涂(tu)料(liao),長度自(zi)孔洞(dong)以下(xia)1.5m左(zuo)右,再用耐火材料(liao)加工成具(ju)有(you)一定(ding)強度的(de)板托防火堵(du)(du)(du)料(liao),保(bao)證封堵(du)(du)(du)后牢(lao)固并(bing)便(bian)于(yu)更(geng)換電(dian)纜時(shi)拆裝,封堵(du)(du)(du)密實無(wu)孔隙以有(you)效地堵(du)(du)(du)煙堵(du)(du)(du)火。

47、噴燈點火前應注(zhu)意哪些檢查?

答:應進(jin)行下列(lie)各項檢查(cha):

(1)打氣(qi)筒(tong)是否(fou)漏油(you)或滲油(you),油(you)桶及噴嘴處是否(fou)漏油(you)、漏氣(qi);

(2)油(you)(you)桶內的油(you)(you)量(liang)是(shi)(shi)否超過油(you)(you)桶容量(liang)的3/4,加油(you)(you)的螺絲塞是(shi)(shi)否擰緊。

48、使用噴燈應注意哪些(xie)事項(xiang)?

答:(1)噴燈更大 注油量為油筒容積的3/4;

(2)開始打氣壓(ya)力不要太大,點燃后火(huo)焰由(you)黃變藍即可使用;

(3)周圍不(bu)得有(you)易燃物,空氣要流通;

(4)停用時(shi)先(xian)關閉調節(jie)開(kai)關,火熄后(hou),慢(man)慢(man)旋(xuan)松(song)油(you)孔蓋(gai)放(fang)氣,空氣放(fang)完后(hou),要要旋(xuan)松(song)調節(jie)開(kai)關,完全冷卻后(hou)再旋(xuan)松(song)孔蓋(gai);

(5)煤(mei)油(you)噴(pen)燈(deng)與汽油(you)噴(pen)燈(deng)要分開(kai)使(shi)用。

49、手動油壓鉗有(you)何(he)(he)用途?如何(he)(he)操作?

答:兩(liang)根導線的(de)(de)連(lian)接通(tong)常是將(jiang)兩(liang)導線端穿入相同材料制成(cheng)的(de)(de)壓(ya)(ya)(ya)(ya)管中,用(yong)壓(ya)(ya)(ya)(ya)接鉗擠壓(ya)(ya)(ya)(ya)數個(ge)坑,使(shi)導線連(lian)接在一(yi)(yi)起(qi),壓(ya)(ya)(ya)(ya)接時(shi)(shi),手柄向上抬(tai)起(qi)時(shi)(shi),柱塞(sai)向外移(yi)(yi)動,進(jin)油(you)(you)(you)閥(fa)下(xia)腔產生真空,油(you)(you)(you)箱內的(de)(de)油(you)(you)(you)進(jin)入柱塞(sai)腔。手柄下(xia)壓(ya)(ya)(ya)(ya)時(shi)(shi),柱塞(sai)向內移(yi)(yi)動,油(you)(you)(you)受壓(ya)(ya)(ya)(ya)后,使(shi)進(jin)油(you)(you)(you)閥(fa)關(guan)閉,打(da)開出油(you)(you)(you)閥(fa),使(shi)油(you)(you)(you)壓(ya)(ya)(ya)(ya)進(jin)入液壓(ya)(ya)(ya)(ya)缸,推動活塞(sai)和陽模(mo),陽、陰(yin)模(mo)之間(jian)放有壓(ya)(ya)(ya)(ya)接管,當壓(ya)(ya)(ya)(ya)接被(bei)擠壓(ya)(ya)(ya)(ya)的(de)(de)坑深到一(yi)(yi)定值時(shi)(shi),開啟回油(you)(you)(you)閥(fa),活塞(sai)自動返回,壓(ya)(ya)(ya)(ya)完一(yi)(yi)個(ge)坑后,移(yi)(yi)動壓(ya)(ya)(ya)(ya)鉗,再壓(ya)(ya)(ya)(ya)下(xia)一(yi)(yi)個(ge)。

50、常用低壓電力(li)電纜按絕(jue)緣和(he)保護層(ceng)的不同,主要可分為哪幾類?

答:(1)油浸(jin)紙絕緣鉛(qian)包(或鋁(lv)包)電(dian)(dian)力電(dian)(dian)纜;

(2)不滴(di)流油浸(jin)紙絕緣電(dian)力(li)電(dian)纜;

(3)聚氯乙(yi)(yi)烯絕緣聚氯乙(yi)(yi)烯護(hu)套電力電纜;

(4)交聯聚氯乙烯絕緣(yuan)聚乙烯護(hu)套電力電纜;

(5)交聯聚(ju)氯(lv)乙(yi)烯絕緣聚(ju)氯(lv)乙(yi)烯護套電力電纜(lan);

(6)橡(xiang)皮絕緣電力電纜。

51、常用絕緣材料的類(lei)別(bie)哪(na)些?舉例說明?

答(da):(1)無機(ji)絕緣材料:有云母、石棉、大理(li)石、瓷(ci)器(qi)、玻璃等;

(2)有機絕緣材料:有樹(shu)脂、橡(xiang)膠、紙、麻、棉紗(sha)等;

(3)混合絕緣(yuan)材料:用(yong)以上(shang)絕緣(yuan)材料加工而成型的名種(zhong)絕緣(yuan)材料。

52、在哪種(zhong)情況下采(cai)用排(pai)管敷設?有什么(me)優點?

答:排管敷設一般用在與其他建(jian)筑物、公(gong)路或鐵路相(xiang)交叉的地(di)方,有(you)時也在建(jian)筑物密(mi)集(ji)區內(nei)采用。主要優點是(shi)占(zhan)地(di)少,能承受大(da)的荷重(zhong),電纜相(xiang)互(hu)間互(hu)不影響,比較安(an)全。

53、何謂電(dian)纜長(chang)期允許載流量?

答:電(dian)纜(lan)(lan)長(chang)期允許載流(liu)量(liang)是指(zhi)在電(dian)纜(lan)(lan)內通過規定電(dian)流(liu)時,在熱穩(wen)定后,電(dian)纜(lan)(lan)導體(ti)達到(dao)長(chang)期允許工作溫度時的電(dian)流(liu)數值(zhi)。

54、決定電纜長(chang)期(qi)允許載流量的因素有哪些?

答:有以下三個因(yin)素決(jue)定:

(1)電(dian)纜的長(chang)期容許工作溫度;

(2)電纜本身的散熱性(xing)能;

(3)電纜(lan)裝置情況(kuang)及(ji)周圍(wei)環(huan)境的散熱條件。

55、電(dian)纜的敷(fu)設方式(shi)有幾種?

答:有以下幾(ji)種(zhong):

(1)直埋在地下(xia);

(2)安裝在電纜溝內(nei);

(3)安裝在地(di)下隧道內;

(4)安裝(zhuang)在建筑(zhu)物內部(bu)墻上(shang)或天(tian)棚上(shang);

(5)安(an)裝(zhuang)在橋架上;

(6)敷設在排管內(nei);

(7)敷設(she)在水(shui)底。

56、如何(he)進行電(dian)纜管(guan)的連接工作?

答(da):電(dian)纜管(guan)(guan)連(lian)接(jie)時,必須用(yong)(yong)扣(kou)和管(guan)(guan)接(jie)頭連(lian)接(jie),如(ru)采用(yong)(yong)焊接(jie)時,不能直接(jie)對焊,連(lian)接(jie)處要套上(shang)一(yi)段粗管(guan)(guan)再進行焊接(jie),以免(mian)焊渣(zha)掉入管(guan)(guan)內。

57、制作電纜頭時,對上下扳彎(wan)電纜芯線有何要求?

答:扳彎(wan)線芯(xin)時,不得損傷紙絕(jue)緣,芯(xin)線的彎(wan)曲半(ban)徑不得小于電(dian)纜線芯(xin)的10倍。制作時要特別小心,應使線芯(xin)彎(wan)曲部分均勻(yun)受(shou)力,否(fou)則極易損傷絕(jue)緣紙。

58、簡述塑料電纜(lan)的熱收縮密封法。

答(da):熱(re)縮(suo)(suo)法適(shi)用(yong)于(yu)(yu)中、低(di)壓橡、塑(su)電纜(lan)(lan)接頭和(he)(he)終端頭的(de)密(mi)封,也可適(shi)用(yong)于(yu)(yu)不滴(di)流和(he)(he)黏性(xing)浸漬絕緣電纜(lan)(lan)。采用(yong)交(jiao)聯聚乙(yi)烯型(xing)和(he)(he)硅(gui)橡膠(jiao)型(xing)兩大類(lei)遇熱(re)后(hou)能均勻收縮(suo)(suo)的(de)熱(re)收縮(suo)(suo)管。將這種管材套(tao)于(yu)(yu)預定的(de)粘(zhan)合(he)密(mi)封部位,并在(zai)粘(zhan)和(he)(he)部位涂(tu)上熱(re)熔(rong)(rong)膠(jiao),當加熱(re)到一定溫度后(hou),熱(re)縮(suo)(suo)管將收縮(suo)(suo),同時熱(re)熔(rong)(rong)膠(jiao)熔(rong)(rong)化(hua),待自然冷卻后(hou)即(ji)形(xing)成一道(dao)良好的(de)密(mi)封封層。

59、用電動彎(wan)管(guan)機(ji)彎(wan)制電纜(lan)保(bao)護管(guan)時(shi)應(ying)注意什么?

答:(1)彎管(guan)機應由(you)了解(jie)其(qi)性能(neng)并(bing)熟(shu)悉操作知(zhi)識的人員操作;

(2)使用前必須進(jin)行檢查,按鈕、操(cao)作(zuo)把(ba)手、行程開關(guan)應完好,彎管機(ji)必須可靠接地;

(3)選用符合(he)要求的模具,確(que)定好(hao)所需要的彎曲(qu)半徑(jing);

(4)施工場地周(zhou)圍,應(ying)有充足(zu)的活(huo)動范圍;

(5)使用時待空轉正常后,方可帶負荷工作,運行中,嚴禁用手腳接觸其轉動(dong)部(bu)分;

(6)工(gong)作完畢應及時停電(dian),釋放(fang)油壓。

60、電纜清冊的(de)內容(rong)及電纜編號的(de)含義(yi)是什么?

答:電(dian)纜(lan)(lan)清冊是(shi)施放電(dian)纜(lan)(lan)和(he)指導(dao)施工的依據,運行(xing)維護的檔(dang)案資(zi)料。應(ying)列入每根電(dian)纜(lan)(lan)的編號、起始點、型號、規格、長度,并分類統計出(chu)總長度,控纜(lan)(lan)還應(ying)列出(chu)每根電(dian)纜(lan)(lan)的備(bei)用芯。

電纜(lan)(lan)(lan)編號是識別電纜(lan)(lan)(lan)的標(biao)志,故要求全廠(chang)編號不重復,并(bing)且有(you)一定的含義和規律(lv),能表達電纜(lan)(lan)(lan)的特征(zheng)。

61、電纜(lan)目前(qian)采用的(de)敷(fu)設方法可分為幾類?

答:(1)人(ren)工(gong)敷設(she),即(ji)采用人(ren)海戰術,在一人(ren)或多人(ren)協(xie)調指揮下,按規定進行(xing)敷設(she);

(2)機(ji)械(xie)化敷設,即采用滾輪、牽引(yin)器、輸(shu)送機(ji),通過一同步電源進行(xing)控(kong)制,比較安(an)全;

(3)人(ren)工和機械相(xiang)結合,有些現場由于轉彎較多(duo),施(shi)工難度大(da),全用(yong)(yong)機械較困(kun)難,所以采用(yong)(yong)此法。

62、控制二(er)次回(hui)路接線(xian)應符合哪些(xie)要求?

答:(1)按圖(tu)施工(gong)接線正(zheng)確;

(2)導線的電(dian)氣連接(jie)應牢固可靠;

(3)盤柜內的導線(xian)不應有接(jie)頭,導線(xian)芯(xin)線(xian)應無損傷(shang);

(4)電纜芯線端(duan)部應(ying)標明(ming)其回(hui)路編號(hao),編號(hao)應(ying)正確(que),字跡清晰(xi)且不易脫(tuo)色;

(5)配線(xian)應整齊、清晰、美觀,導線(xian)絕緣應良好、無損;

(6)每個接線端子的(de)每側(ce)接線宜為一根(gen),最(zui)多不(bu)得超(chao)過兩(liang)根(gen)。

63、電纜排管有(you)何要求?

答:(1)排管頂部至地面距離(li),在廠房內為(wei)0.2m,人(ren)行道下為(wei)0.5m,一般地區為(wei)0.7m;

(2)在變更(geng)方向及(ji)分支處均應裝置(zhi)排管井坑,長度超(chao)過30mm時也應加設井坑;

(3)井坑深度不(bu)(bu)小于(yu)0.8m,人孔直(zhi)徑不(bu)(bu)小于(yu)0.7mm;

(4)排(pai)管(guan)應有傾向(xiang)井坑(keng)0.5%~1%的排(pai)水坡(po)度。

64、對于電纜導(dao)體連(lian)接點的電阻有何要(yao)求(qiu)?

答:要求(qiu)連接點的(de)(de)(de)電阻小而且穩定,連接點的(de)(de)(de)電阻與相同長(chang)度(du)、相同截面的(de)(de)(de)導(dao)體之比值(zhi),對(dui)于新安(an)裝的(de)(de)(de)終端頭(tou)和(he)(he)中(zhong)(zhong)間頭(tou),應不大于1;對(dui)于運行中(zhong)(zhong)的(de)(de)(de)終端頭(tou)和(he)(he)中(zhong)(zhong)間頭(tou)這個比值(zhi)不應大于1.2。

65、電纜接頭和中間頭的設計(ji)應(ying)滿足哪(na)些要求?

答(da):應滿足的要求有:

(1)耐壓強度高(gao),導體連接好;

(2)機(ji)械強度大,介質(zhi)損失小;

(3)結(jie)構簡單(dan),密封(feng)性強。

66、什么(me)是電纜故障?有幾種常見的類型?

答:電纜故(gu)(gu)(gu)障是(shi)指電纜在預防(fang)性(xing)試驗(yan)時發生絕(jue)緣擊(ji)穿或在運行中,因絕(jue)緣擊(ji)穿、導(dao)線(xian)燒斷等而迫使(shi)電纜線(xian)路停電的故(gu)(gu)(gu)障。常見的故(gu)(gu)(gu)障有接(jie)地(di)故(gu)(gu)(gu)障、短路故(gu)(gu)(gu)障、斷線(xian)故(gu)(gu)(gu)障、閃絡性(xing)故(gu)(gu)(gu)障和混合型故(gu)(gu)(gu)障等。

67、如(ru)何處理(li)電(dian)纜線路的單相(xiang)接地故(gu)障?

答:電(dian)(dian)纜線路單(dan)相接(jie)地故障一(yi)般來說(shuo),電(dian)(dian)纜導體的損傷(shang)只是(shi)局部的,如果屬于機械損傷(shang),而(er)故障點(dian)(dian)附近的土壤又較干燥時,一(yi)般可進行局部修理,加添一(yi)只假接(jie)頭,即不將電(dian)(dian)纜芯(xin)鋸斷(duan),僅(jin)將故障點(dian)(dian)絕緣(yuan)加強后密(mi)封即可。

68、電力電纜在敷(fu)設前應進行哪些(xie)試驗和(he)檢查?

答:敷設(she)前(qian)應檢查電(dian)纜的型號、規格(ge)及長度(du)是(shi)否符合要求,是(shi)否有外力損傷,低(di)壓電(dian)纜用1000V兆(zhao)歐表遙測絕緣電(dian)阻(zu),阻(zu)值一般(ban)(ban)不低(di)于10MΩ,高壓電(dian)纜用2500V兆(zhao)歐表搖(yao)測阻(zu)值一般(ban)(ban)不抵(di)于400MΩ。

69、主廠房內(nei)敷設電纜時一般應注意什么?

答:在主廠房內敷設電纜時一般應注(zhu)意(yi):

(1)凡引至集控室的控制電纜宜(yi)架空敷設;

(2)6KV電纜宜用隧道或排管敷(fu)設,地下(xia)水(shui)位高處(chu)亦可架(jia)空(kong)或用排管敷(fu)設;

(3)380V電纜(lan)當兩端電纜(lan)在零米時宜(yi)用隧道、溝或排管,當一(yi)端設備在上、一(yi)端在下(xia)(xia)時,可部(bu)分(fen)架空敷設,當地下(xia)(xia)水位(wei)較(jiao)高時,宜(yi)架空。

70、電力電纜的內屏蔽層與外屏蔽層各(ge)在(zai)什么(me)部(bu)位(wei)?采用(yong)什么(me)材料(liao)?有何(he)作用(yong)?

答:為了使(shi)絕緣層(ceng)(ceng)(ceng)(ceng)和電(dian)纜導體有(you)(you)(you)較(jiao)好的(de)(de)接觸,消除導體表面(mian)的(de)(de)不光滑引起的(de)(de)導體表面(mian)電(dian)場強度的(de)(de)增加,一般在導體表面(mian)包有(you)(you)(you)金(jin)屬化(hua)紙或半(ban)導體紙帶(dai)(dai)的(de)(de)內屏(ping)蔽(bi)(bi)層(ceng)(ceng)(ceng)(ceng)。為了使(shi)絕緣層(ceng)(ceng)(ceng)(ceng)和金(jin)屬護套有(you)(you)(you)較(jiao)好的(de)(de)接觸,一般在絕緣層(ceng)(ceng)(ceng)(ceng)外表面(mian)包有(you)(you)(you)外層(ceng)(ceng)(ceng)(ceng)屏(ping)蔽(bi)(bi)層(ceng)(ceng)(ceng)(ceng)。外屏(ping)層(ceng)(ceng)(ceng)(ceng)與(yu)內屏(ping)層(ceng)(ceng)(ceng)(ceng)的(de)(de)材料相(xiang)同,有(you)(you)(you)時還外扎銅帶(dai)(dai)或編(bian)織(zhi)銅絲(si)帶(dai)(dai)。

71、簡述環氧(yang)樹(shu)脂(zhi)復合物的構(gou)成及(ji)性能(neng)。

答:環氧樹(shu)脂(zhi)復合物由環氧樹(shu)脂(zhi)加入硬化(hua)劑、填充(chong)劑增韌劑和(he)稀(xi)釋劑組成(cheng)。具有(you)以下性(xing)能(neng):

(1)有足夠的機械強(qiang)度;

(2)電(dian)氣性能優良(liang);

(3)電氣性能穩定;

(4)與有(you)色金屬有(you)足夠的(de)黏附(fu)力;

(5)耐腐(fu)蝕性好;

(6)戶外使用時(shi),耐雨、耐光、耐濕熱。

72、單芯電纜(lan)護套一(yi)端接地方式中(zhong)為什么必(bi)須安裝一(yi)條沿電纜(lan)平行敷設的(de)回流線?

答:在金屬護(hu)套(tao)一(yi)(yi)端(duan)接地的(de)(de)(de)電(dian)纜線(xian)路中,為(wei)確保(bao)護(hu)套(tao)中的(de)(de)(de)感應(ying)(ying)電(dian)壓不超過允許標(biao)準,必(bi)須(xu)安裝一(yi)(yi)條沿電(dian)纜線(xian)路平行敷設的(de)(de)(de)導(dao)(dao)體,且(qie)導(dao)(dao)體的(de)(de)(de)兩(liang)端(duan)接地,這種(zhong)導(dao)(dao)體稱為(wei)回流(liu)線(xian)。當發生單相接地故障(zhang)時,接地短(duan)路電(dian)流(liu)可(ke)以(yi)通過回流(liu)線(xian)流(liu)回系(xi)統中心點(dian),由于通過回流(liu)線(xian)的(de)(de)(de)接地電(dian)流(liu)產(chan)生的(de)(de)(de)磁通抵消了一(yi)(yi)部分(fen)電(dian)纜導(dao)(dao)線(xian)接地電(dian)流(liu)所產(chan)生的(de)(de)(de)磁通,因而可(ke)降低短(duan)路故障(zhang)時護(hu)套(tao)的(de)(de)(de)感應(ying)(ying)電(dian)壓。

73、電纜工程可劃分為幾個(ge)項(xiang)目(mu)?

答(da):(1)工地運(yun)輸:包括工程(cheng)材料從倉庫到施工點的(de)裝(zhuang)卸、運(yun)輸和空車(che)回程(cheng)。

(2)地(di)方工(gong)程(cheng):包括路(lu)面開挖、隧(sui)、溝道施(shi)工(gong)等。

(3)敷設工程:包括敷設、中間頭制作、掀(xian)蓋板(ban)、埋管(guan)、校(xiao)潮(chao)、牽引頭制作等。

(4)兩端工程(cheng):包(bao)括支、吊橋架(jia)和其基礎的制作安(an)裝,終端頭制作,油壓(ya)力和信號(hao)裝置的安(an)裝,名種(zhong)電氣性能測(ce)試(shi)等(deng)。

(5)塞(sai)止工程:包括充油電纜(lan)塞(sai)止頭制作,供油箱、自(zi)動排(pai)水及(ji)信(xin)號(hao)裝置(zhi)的(de)安裝等。

(6)接(jie)地(di)工(gong)程:包括絕(jue)緣(yuan)接(jie)頭(tou)、換(huan)位箱、保(bao)護器、接(jie)地(di)箱安裝等。

74、電纜線(xian)路的驗(yan)收應進行(xing)哪些檢(jian)查(cha)?

答:(1)電纜規(gui)格應符合規(gui)定,排列應整齊,無(wu)損傷,標牌齊全、正確、清晰;

(2)電(dian)纜的(de)固定彎曲半徑、有關距離及單芯(xin)電(dian)力電(dian)纜的(de)金屬護(hu)層(ceng)的(de)接(jie)線應符合要求;

(3)電纜(lan)終端、中間頭(tou)不滲漏油,安裝(zhuang)牢固,充油電纜(lan)油壓(ya)及表計整定值應(ying)符合要求;

(4)接地良好;

(5)電纜(lan)終端相(xiang)色(se)正(zheng)確,支架等的金(jin)屬部(bu)件油漆完整;

(6)電纜溝(gou)及(ji)隧道內、橋架上(shang)應無(wu)雜(za)物,蓋(gai)板齊全。

75、電纜線路正序阻抗測量(liang)過程中有什么要求?

答:電纜導(dao)體的(de)交流電阻和電纜三(san)相(xiang)同感抗的(de)相(xiang)量和稱(cheng)為正序阻抗。

電(dian)(dian)(dian)纜(lan)線(xian)路的(de)(de)正序阻(zu)抗一般可在電(dian)(dian)(dian)纜(lan)盤上(shang)直接測(ce)量(liang)(liang),測(ce)量(liang)(liang)時(shi)一般使用(yong)較低的(de)(de)電(dian)(dian)(dian)壓(ya)(ya)(ya),因此,需要用(yong)降(jiang)壓(ya)(ya)(ya)變壓(ya)(ya)(ya)器(qi)進(jin)行降(jiang)壓(ya)(ya)(ya),降(jiang)壓(ya)(ya)(ya)器(qi)采用(yong)星(xing)形接線(xian),容量(liang)(liang)一般為10kVA以上(shang),有較廣的(de)(de)電(dian)(dian)(dian)壓(ya)(ya)(ya)調節范圍,測(ce)量(liang)(liang)時(shi)交流電(dian)(dian)(dian)源應比較穩定,以保證測(ce)量(liang)(liang)時(shi)電(dian)(dian)(dian)流達到規定的(de)(de)要求,實(shi)際電(dian)(dian)(dian)壓(ya)(ya)(ya)表的(de)(de)讀(du)(du)數值(zhi)必須是(shi)電(dian)(dian)(dian)纜(lan)端的(de)(de)電(dian)(dian)(dian)壓(ya)(ya)(ya),試驗電(dian)(dian)(dian)流更(geng)好 接近電(dian)(dian)(dian)纜(lan)長期(qi)允許(xu)載流量(liang)(liang),測(ce)讀(du)(du)各表計的(de)(de)數值(zhi)時(shi),合上(shang)電(dian)(dian)(dian)流后同時(shi)讀(du)(du)取(qu)三(san)個表的(de)(de)數值(zhi)。

76、根據《電業(ye)生產安全(quan)規定》,電氣工(gong)作人員(yuan)必須具備的條件是什(shen)么?

答(da):必(bi)須(xu)具(ju)備下列條件:

(1)經醫(yi)生鑒定身體健(jian)康,無妨(fang)礙工作的病癥(zheng);

(2)具備(bei)必要(yao)的電氣知識,按其(qi)職(zhi)務(wu)和工作性質掌握(wo)相關的規程、專(zhuan)業技術及安全(quan)操作技術,并經考試合格;

(3)熟(shu)練掌握觸電(dian)急(ji)救方法。

77、電纜在運(yun)輸裝卸過程中應注意什么(me)?

答:(1)在運輸裝(zhuang)卸過(guo)程中,不應使電(dian)(dian)(dian)纜(lan)及電(dian)(dian)(dian)纜(lan)盤(pan)(pan)受(shou)到損傷,嚴禁將電(dian)(dian)(dian)纜(lan)盤(pan)(pan)直(zhi)接(jie)由車上(shang)推下,電(dian)(dian)(dian)纜(lan)般不應平放(fang)運輸,平放(fang)貯存。

(2)運輸或滾(gun)動電(dian)纜(lan)(lan)盤前,必須保證電(dian)纜(lan)(lan)盤牢固(gu),電(dian)纜(lan)(lan)繞緊、充油電(dian)纜(lan)(lan)至壓(ya)力油箱間的油管應固(gu)定(ding),不得損傷,壓(ya)力油箱應牢固(gu),壓(ya)力指(zhi)示應符合要求。

78、電纜防火有哪(na)些措施?

答:(1)采用阻(zu)燃電纜;

(2)采(cai)用防火電纜(lan)托架;

(3)采用防火涂(tu)料;

(4)電(dian)纜隧道(dao)、夾層出口等處設置防火(huo)隔墻、防火(huo)擋板;

(5)架(jia)空電纜應避開油管道、防(fang)爆(bao)門,否則應有要(yao)取局(ju)部穿管或隔熱防(fang)火措(cuo)施(shi)。

79、選擇電力電纜的截面應從(cong)哪幾個(ge)方面考慮?

答(da):應(ying)考慮如下幾(ji)個方面:

(1)電纜長(chang)期允許通(tong)過的(de)工(gong)作電流;

(2)一(yi)旦短路時的熱穩(wen)定性(xing);

(3)線(xian)路上(shang)的(de)電壓降不(bu)能超出允許工作(zuo)范圍。

80、電力電纜和架空線(xian)比(bi)較有哪(na)些(xie)優點(dian)?

答:(1)運行(xing)可靠,由于安(an)裝在地下等隱蔽處,受外力(li)破壞小(xiao),發生故障的機(ji)會(hui)較少,供(gong)電安(an)全,不會(hui)給人身造成危害;

(2)維護工作量小,不需頻繁的(de)巡檢;

(3)不需(xu)架設桿塔;

(4)有(you)助于提高(gao)功率因數(shu)。