1、常用的電線、電纜按用途分有哪(na)些種類?
答:按用(yong)途可分為裸導線(xian)(xian)、絕緣電(dian)(dian)線(xian)(xian)、耐熱電(dian)(dian)線(xian)(xian)、屏蔽電(dian)(dian)線(xian)(xian)、電(dian)(dian)力電(dian)(dian)纜、控制(zhi)電(dian)(dian)纜、通信電(dian)(dian)纜、射頻電(dian)(dian)纜等。
2、絕緣電線有哪幾種?
答:常(chang)有的絕(jue)緣(yuan)(yuan)(yuan)電線(xian)(xian)(xian)有以下幾種(zhong):聚氯乙(yi)烯(xi)(xi)絕(jue)緣(yuan)(yuan)(yuan)電線(xian)(xian)(xian)、聚氯乙(yi)烯(xi)(xi)絕(jue)緣(yuan)(yuan)(yuan)軟(ruan)(ruan)線(xian)(xian)(xian)、丁腈聚氯乙(yi)烯(xi)(xi)混合(he)物(wu)絕(jue)緣(yuan)(yuan)(yuan)軟(ruan)(ruan)線(xian)(xian)(xian)、橡(xiang)皮絕(jue)緣(yuan)(yuan)(yuan)電線(xian)(xian)(xian)、農用(yong)地下直埋鋁芯塑料絕(jue)緣(yuan)(yuan)(yuan)電線(xian)(xian)(xian)、橡(xiang)皮絕(jue)緣(yuan)(yuan)(yuan)棉(mian)紗紡(fang)織軟(ruan)(ruan)線(xian)(xian)(xian)、聚氯乙(yi)烯(xi)(xi)絕(jue)緣(yuan)(yuan)(yuan)尼龍護套電線(xian)(xian)(xian)、電力和照明(ming)用(yong)聚氯乙(yi)烯(xi)(xi)絕(jue)緣(yuan)(yuan)(yuan)軟(ruan)(ruan)線(xian)(xian)(xian)等。
3、電纜橋架(jia)適(shi)合(he)于何種場合(he)?
答(da):電(dian)(dian)纜(lan)(lan)橋(qiao)架適用于一般工礦企業室(shi)內(nei)外架空敷設(she)電(dian)(dian)力電(dian)(dian)纜(lan)(lan)、控制(zhi)電(dian)(dian)纜(lan)(lan),亦可用于電(dian)(dian)信、廣播(bo)電(dian)(dian)視等部門在(zai)室(shi)內(nei)外架設(she)。
4、電(dian)纜附件有(you)哪些?
答(da):常用的電附(fu)件有(you)電纜(lan)終端(duan)接(jie)(jie)線盒(he)、電纜(lan)中間接(jie)(jie)線盒(he)、連接(jie)(jie)管及接(jie)(jie)線端(duan)子、鋼板(ban)接(jie)(jie)線槽、電纜(lan)橋架等。
5、什么叫電纜中(zhong)間(jian)接頭?
答(da):連(lian)接電纜(lan)(lan)與電纜(lan)(lan)的導體、絕(jue)緣屏蔽層和保護層,以(yi)使電纜(lan)(lan)線路連(lian)接的裝置,稱為電纜(lan)(lan)中間接頭。
6、什么叫(jiao)電氣主接(jie)線(xian)?
答:電(dian)氣主接(jie)線是發電(dian)廠、變電(dian)所中主要(yao)(yao)電(dian)氣設備和(he)母(mu)線的連接(jie)方式,包括主母(mu)線和(he)廠用電(dian)系統按一定的功能要(yao)(yao)求的連接(jie)方式。
7、在選擇電(dian)力電(dian)纜的(de)截面時,應(ying)遵照哪些規(gui)定?
答(da):電(dian)力電(dian)纜的(de)(de)選擇應遵照以下(xia)原(yuan)則:(1)電(dian)纜的(de)(de)額(e)定電(dian)壓要大于或等(deng)于安裝點供(gong)電(dian)系統的(de)(de)額(e)定電(dian)壓;(2)電(dian)纜持續(xu)容許電(dian)流應等(deng)于或大于供(gong)電(dian)負載的(de)(de)更大 持續(xu)電(dian)流;(3)線芯截面(mian)要滿(man)足供(gong)電(dian)系統短(duan)路(lu)時的(de)(de)穩定性(xing)的(de)(de)要求;(4)根(gen)據電(dian)纜長度驗算(suan)電(dian)壓降是(shi)否符合要求;(5)線路(lu)末端的(de)(de)最小短(duan)路(lu)電(dian)流應能使保護裝置可(ke)靠的(de)(de)動(dong)作。
8、交(jiao)聯聚乙烯電纜和油(you)紙電纜比較有(you)哪些優點?
答:(1)易(yi)安裝,因為(wei)它允許最小彎曲半(ban)徑小、且(qie)重量(liang)(liang)輕;(2)不受線路落(luo)差*;(3)熱(re)性能(neng)好,允許工(gong)作溫度高、傳輸(shu)容量(liang)(liang)大;(4)電纜附件簡(jian)(jian)單,均為(wei)干式(shi)結構;(5)運行(xing)維護(hu)簡(jian)(jian)單,無漏油問(wen)題(ti);(6)價格較低;(7)可靠性高、故障率低;(8)制造工(gong)序(xu)少、工(gong)藝(yi)簡(jian)(jian)單,經濟效益顯(xian)著。
9、固定交流單(dan)芯電纜(lan)的夾(jia)具有什(shen)么要求?為什(shen)么?
答:夾(jia)具(ju)應(ying)無鐵件(jian)構成(cheng)閉合(he)磁(ci)路,這是(shi)因(yin)為當電(dian)纜(lan)(lan)(lan)(lan)線(xian)芯(xin)通(tong)過電(dian)流(liu)時,在(zai)其周圍產(chan)生(sheng)磁(ci)力(li)線(xian),磁(ci)力(li)線(xian)與通(tong)過線(xian)芯(xin)的電(dian)流(liu)大小成(cheng)正比(bi),若(ruo)使用鐵件(jian)等(deng)導(dao)磁(ci)材料,根據電(dian)磁(ci)感(gan)應(ying)可(ke)知,將在(zai)鐵件(jian)中產(chan)生(sheng)渦流(liu)使電(dian)纜(lan)(lan)(lan)(lan)發熱,甚至燒(shao)壞電(dian)纜(lan)(lan)(lan)(lan)。所以不可(ke)使用鐵件(jian)作單芯(xin)交流(liu)電(dian)纜(lan)(lan)(lan)(lan)的固定夾(jia)具(ju)。
10、以下的熱縮電纜頭的附件的更大 特點和優點是什么(me)?
答:熱縮附(fu)件(jian)的(de)更(geng)大 特點是用(yong)應力(li)管代(dai)替傳統的(de)應力(li)錐,它(ta)不(bu)僅簡(jian)化了施工工藝,還縮小了接頭的(de)終端(duan)的(de)尺寸,安裝(zhuang)方便,省(sheng)時省(sheng)工,性(xing)能優越,節(jie)約金屬。熱縮電纜附(fu)件(jian)集灌注式和干包(bao)式為一(yi)體,集合了這兩種附(fu)件(jian)的(de)優點。
11、電纜敷設前應(ying)進(jin)行哪(na)些檢查工作(zuo)?
答(da):(1)支(zhi)架應齊全、油漆完(wan)整。(2)電(dian)纜型號(hao)、電(dian)壓(ya)、規(gui)格符合設計。(3)電(dian)纜絕緣(yuan)良好,當對(dui)油紙電(dian)纜的密封有懷疑時,應進行受潮判斷;直埋電(dian)纜與小(xiao)底電(dian)纜應經(jing)直流(liu)耐壓(ya)試難合格;充(chong)油電(dian)纜的油樣應試驗合格。(4)充(chong)油電(dian)纜的油壓(ya)不宜低于1.47MPa。
11、交聯熱收縮(suo)電纜附件有(you)哪些(xie)優(you)點?
答:這是一(yi)種新型材料(liao),它與現(xian)在其他(ta)類(lei)型附件比較具有電氣(qi)性能(neng)優越、體積小(xiao)、質(zhi)量小(xiao)、安裝簡便、材料(liao)配套等優點(dian),另(ling)外(wai)還(huan)具有耐氣(qi)候(hou)、抗污穢性、阻燃(ran)自熄等能(neng)力。
12、對油紙絕緣電力電纜密封(feng)有懷(huai)疑時,如(ru)何用較簡(jian)單的辦法檢查電纜絕緣紙是否受(shou)潮?
答:把(ba)電(dian)纜(lan)絕緣紙點(dian)燃或放入(ru)150℃左右的電(dian)纜(lan)油中檢查,無“嘶嘶”聲或白色(se)泡沫出現,說明(ming)未受潮(chao)。
13、電纜標志(zhi)牌應注明什(shen)么內容?編寫(xie)有何要求?
答:標志(zhi)牌上應注明電纜(lan)線路設計編(bian)號(hao)、電纜(lan)型(xing)號(hao)、規格及始點(dian),并(bing)聯使(shi)用的電纜(lan)應有順序號(hao)。要求字跡清晰、不易脫落。
14、直埋(mai)電纜的方位(wei)標(biao)志應設置在哪些位(wei)置?
答(da):在電纜(lan)兩端,電纜(lan)直(zhi)線段50~100m處電纜(lan)接頭幾電纜(lan)改變方向的彎(wan)角處。
15、制作電纜(lan)接頭用(yong)的黃臘(la)綢帶(dai)、黑玻璃漆(qi)帶(dai)、無堿(jian)玻璃絲(si)帶(dai)等,施(shi)工前如何進行排潮處理?
答:(1)恒溫干燥法:將絕緣帶卷成直徑為25~30mm小卷,放(fang)(fang)入(ru)(ru)110~120℃恒溫干燥箱內(nei)烘4~5h,冷卻(que)干取出,放(fang)(fang)入(ru)(ru)干燥的(de)密封筒內(nei)。(2)油(you)浸(jin)排(pai)潮法:將絕緣帶小卷放(fang)(fang)入(ru)(ru)恒溫在120~130℃的(de)電(dian)纜油(you)中,離鍋底(di)保持30mm距離,經一定時(shi)間后(hou)油(you)面不(bu)再產生泡(pao)沫(mo)后(hou)取出,裝(zhuang)入(ru)(ru)貯有電(dian)纜油(you)的(de)桶中,油(you)位應超過所有裝(zhuang)入(ru)(ru)的(de)物體并將其密封。
16、電(dian)纜外(wai)護(hu)層的作用是(shi)什么(me)?
答:保護(hu)內護(hu)層不受機械(xie)損(sun)傷和(he)化學腐蝕,增(zeng)強(qiang)機械(xie)強(qiang)度。
17、室(shi)外電(dian)纜溝應符合哪些要求(qiu)?
答:電纜溝上(shang)部應比地面(mian)稍高,加蓋用混凝土制作的蓋板(ban),電纜應平敷在支(zhi)架上(shang),有良好(hao)的排水(shui)管。
18、電(dian)纜內(nei)護層的作(zuo)用(yong)是什么?
答;使絕(jue)緣(yuan)層不會與(yu)水、空氣或其他物體接觸(chu),防止(zhi)絕(jue)緣(yuan)受(shou)潮(chao)和絕(jue)緣(yuan)層不受(shou)機械傷害。
19、使用鋼絲鉗(qian)時應注意(yi)些什么?
答:使(shi)用(yong)(yong)前,一定要檢(jian)查絕緣(yuan)柄的(de)絕緣(yuan)是否完(wan)好(hao)無損(sun),使(shi)用(yong)(yong)時不可用(yong)(yong)鋼(gang)(gang)絲鉗剪切(qie)超過規(gui)格所(suo)允許的(de)金屬(shu)線材,并(bing)禁止用(yong)(yong)鋼(gang)(gang)絲鉗代替(ti)錘子敲打工具,以免損(sun)壞。
20、什么叫(jiao)絕緣強度?
答(da):絕緣物質在電(dian)場(chang)中,當(dang)電(dian)場(chang)強(qiang)度(du)增(zeng)大到某一極(ji)限時就(jiu)會被擊穿,這個導(dao)致絕緣擊穿的(de)電(dian)場(chang)強(qiang)度(du)稱(cheng)為絕緣強(qiang)度(du)。
22、對電纜(lan)導體連接點的機械強(qiang)度(du)有何要求?
答:連接點(dian)的(de)機械強度(du),一般低于電纜導(dao)體(ti)本身的(de)抗拉強度(du),對于固(gu)定敷設的(de)電力電纜,其連接點(dian)的(de)抗拉強度(du)要求不低于導(dao)體(ti)本身抗拉強度(du)的(de)60%。
23、電(dian)力電(dian)纜的絕(jue)緣(yuan)層材料應具備(bei)哪(na)些主要性能?
答;應具備(bei)下(xia)列主要性(xing)能(neng):(1)高(gao)的(de)擊穿強度;(2)低的(de)介質損耗;(3)相當高(gao)的(de)絕緣(yuan)(yuan)電阻;(4)優良的(de)耐放電性(xing)能(neng);(5)具有一定的(de)柔軟性(xing)和機(ji)械強度;(6)絕緣(yuan)(yuan)性(xing)能(neng)長期穩定。
24、機械敷(fu)設電纜時,牽引強(qiang)度有(you)何規定?
答:對于銅芯(xin)電(dian)(dian)纜(lan)(lan)(lan),當牽(qian)引(yin)頭(tou)部(bu)時(shi),允(yun)(yun)許(xu)(xu)(xu)牽(qian)引(yin)強度(du)為70N/cm;對于鋁芯(xin)電(dian)(dian)纜(lan)(lan)(lan),當牽(qian)引(yin)頭(tou)部(bu)時(shi),允(yun)(yun)許(xu)(xu)(xu)牽(qian)引(yin)強度(du)為40N/cm;若利用鋼絲網套牽(qian)引(yin)時(shi),鉛(qian)護套電(dian)(dian)纜(lan)(lan)(lan)允(yun)(yun)許(xu)(xu)(xu)強度(du)為10N/cm;鉛(qian)護套電(dian)(dian)纜(lan)(lan)(lan)為40N/cm。
25、對(dui)電纜(lan)保(bao)護管有(you)何(he)規定?
答:(1)電纜需要穿保護管(guan)(guan)(guan)敷(fu)設時(shi),管(guan)(guan)(guan)子內徑不應(ying)小(xiao)于電纜外徑的1.5倍,混(hun)凝土管(guan)(guan)(guan)、陶土管(guan)(guan)(guan)、石棉、水泥(ni)管(guan)(guan)(guan)的內徑不應(ying)小(xiao)于100mm;
(2)電纜(lan)管的彎(wan)曲半徑(jing)應(ying)符合所穿(chuan)入電纜(lan)彎(wan)曲半徑(jing)的規定;
(3)每根管(guan)子最(zui)多(duo)不(bu)應超過三個彎頭,直角彎不(bu)應多(duo)于2個。
26、如何(he)測量電(dian)纜護(hu)套(tao)的外徑?
答:在護(hu)(hu)套圓周上均勻分(fen)布的五點處(chu),測量護(hu)(hu)套外徑和其(qi)平均值,其(qi)平均外徑既為護(hu)(hu)套的外徑。
27、不同(tong)截面(mian)的銅芯(xin)電纜如何連接?
答:不同(tong)截面的(de)銅芯電纜(lan)連接(jie),可采用(yong)開口弱(ruo)背(bei)銅接(jie)管,以(yi)錫焊法連接(jie),也可用(yong)純(chun)銅棒(bang)按(an)不同(tong)的(de)截面要求連接(jie)成銅接(jie)管,以(yi)壓接(jie)法連接(jie)。
28、簡述10KV交(jiao)聯電(dian)纜熱(re)縮式制作戶(hu)內終端頭(tou)的過程?
答;(1)準備階(jie)段:檢查(cha)熱縮電纜附件是否齊備,型號是否相(xiang)配,檢查(cha)并確認(ren)電纜有無潮氣(qi)后,檢查(cha)電纜。
(2)切除多余電纜(lan),根據現場情(qing)況決定(ding)電纜(lan)長度(du)。
(3)剝除護層。
(4)焊接接地線,將接地線焊接在鋼(gang)帶上。
(5)填充(chong)三叉口及繞包密封(feng)膠。
(6)安(an)裝三芯分支護套(tao),將護套(tao)套(tao)入根部,從中部開始收縮,先往(wang)根部,再(zai)往(wang)指部。
(7)剝銅(tong) 帶和外半導電層,剝切(qie)三芯分支(zhi)套口20mm以上(shang)的(de)銅(tong)帶,嚴禁損傷主絕(jue)緣,清除干凈半導電層。
(8)安裝(zhuang)應(ying)力管(guan),管(guan)口端(duan)部分支套對(dui)接后熱(re)縮。
(9)安裝接線端子。
(10)安(an)裝(zhuang)絕緣管。
(11)安裝(zhuang)密封管(guan)。
(12)核相(xiang)后安(an)裝相(xiang)色管。
29、戶(hu)內、戶(hu)外預制(zhi)式終端安(an)裝(zhuang)步驟有哪些?
答(da):(1) 將電纜按預定位置就(jiu)位、固定、清潔(jie)表面,參照說明(ming)書剝除外(wai)護套,如有特殊需要,外(wai)護套剝切長(chang)度可調整,分別由銅帶、外(wai)護套鎧裝引(yin)出2組地線。
(2) 由(you)外護套(tao)口向(xiang)上量取需要(yao)尺(chi)寸,切除(chu)多余(yu)(yu)電纜(lan),套(tao)入熱縮(suo)三指套(tao)至(zhi)三叉口根部由(you)中間加(jia)熱收縮(suo),由(you)指套(tao)上口向(xiang)上量取規(gui)定尺(chi)寸(35kv為350~380mm)。去掉多余(yu)(yu)銅帶(保留20mm),再保留半導體預定位置,壓接出線端子(zi)密(mi)封。
30、電(dian)線電(dian)纜(lan)的應用主要分為三大類 :
(1)、電(dian)力(li)系統
電(dian)(dian)(dian)(dian)力(li)(li)系統采(cai)用的電(dian)(dian)(dian)(dian)線(xian)電(dian)(dian)(dian)(dian)纜(lan)(lan)產品主要有架(jia)空(kong)(kong)裸(luo)電(dian)(dian)(dian)(dian)線(xian)、匯流排(母線(xian))、電(dian)(dian)(dian)(dian)力(li)(li)電(dian)(dian)(dian)(dian)纜(lan)(lan)(塑料(liao)線(xian)纜(lan)(lan)、油紙力(li)(li)纜(lan)(lan)(基本(ben)被塑料(liao)電(dian)(dian)(dian)(dian)力(li)(li)電(dian)(dian)(dian)(dian)纜(lan)(lan)代替)、橡套線(xian)纜(lan)(lan)、架(jia)空(kong)(kong)絕緣(yuan)電(dian)(dian)(dian)(dian)纜(lan)(lan))、分支(zhi)電(dian)(dian)(dian)(dian)纜(lan)(lan)(取代部(bu)分母線(xian))、電(dian)(dian)(dian)(dian)磁(ci)線(xian)以及電(dian)(dian)(dian)(dian)力(li)(li)設(she)備(bei)用電(dian)(dian)(dian)(dian)氣裝備(bei)電(dian)(dian)(dian)(dian)線(xian)電(dian)(dian)(dian)(dian)纜(lan)(lan)等。
(2)、信息傳輸(shu)系(xi)統
用于信息傳輸(shu)系統的電(dian)(dian)(dian)線電(dian)(dian)(dian)纜(lan)(lan)主(zhu)要有市話(hua)電(dian)(dian)(dian)纜(lan)(lan)、電(dian)(dian)(dian)視電(dian)(dian)(dian)纜(lan)(lan)、電(dian)(dian)(dian)子線纜(lan)(lan)、射頻電(dian)(dian)(dian)纜(lan)(lan)、光纖纜(lan)(lan)、數據電(dian)(dian)(dian)纜(lan)(lan)、電(dian)(dian)(dian)磁線、電(dian)(dian)(dian)力通訊(xun)或其他復合電(dian)(dian)(dian)纜(lan)(lan)等。
(3)、機械設備、儀器儀表(biao)系統
此部分除(chu)架(jia)空裸(luo)電線(xian)(xian)外幾乎其他(ta)所有(you)產品(pin)均有(you)應用,但主要是電力(li)電纜(lan)、電磁線(xian)(xian)、數據(ju)電纜(lan)、儀(yi)器(qi)儀(yi)表線(xian)(xian)纜(lan)等。
31、電線電纜產品主(zhu)要分為五(wu)大類:
(1)、裸電(dian)線(xian)及裸導(dao)體(ti)制(zhi)品(pin)(pin) 本類產品(pin)(pin)的主(zhu)(zhu)要特征是(shi):純的導(dao)體(ti)金屬,無絕緣及護套層,如鋼芯鋁絞(jiao)線(xian)、銅(tong)鋁匯(hui)流排、電(dian)力機車(che)線(xian)等;加工(gong)工(gong)藝主(zhu)(zhu)要是(shi)壓(ya)(ya)力加工(gong),如熔煉、壓(ya)(ya)延(yan)、拉制(zhi)、絞(jiao)合/緊(jin)壓(ya)(ya)絞(jiao)合等;產品(pin)(pin)主(zhu)(zhu)要用(yong)在城郊、農村、用(yong)戶主(zhu)(zhu)線(xian)、開關(guan)柜(ju)等。
(2)、電(dian)力電(dian)纜(lan)(lan)本類產(chan)品主(zhu)要特征是:在導體外擠(ji)(繞)包絕(jue)緣層,如(ru)架(jia)(jia)空絕(jue)緣電(dian)纜(lan)(lan),或幾芯絞合(he)(對應電(dian)力系(xi)統的(de)相線(xian)、零(ling)線(xian)和地線(xian)),如(ru)二(er)芯以上架(jia)(jia)空絕(jue)緣電(dian)纜(lan)(lan),或再增加(jia)護套(tao)層,如(ru)塑料/橡套(tao)電(dian)線(xian)電(dian)纜(lan)(lan)。主(zhu)要的(de)工藝技(ji)術有拉制、絞合(he)、絕(jue)緣擠(ji)出(chu)(繞包)、成纜(lan)(lan)、鎧裝、護層擠(ji)出(chu)等,各種產(chan)品的(de)不(bu)同工序組(zu)合(he)有一定區別。
產(chan)品主要用(yong)在發、配、輸(shu)、變、供(gong)電(dian)(dian)線路中的(de)強(qiang)電(dian)(dian)電(dian)(dian)能傳輸(shu),通過的(de)電(dian)(dian)流大(da)(幾十安至(zhi)幾千(qian)安)、電(dian)(dian)壓高(220V至(zhi)500kV及以上(shang))。
(3)、電(dian)(dian)(dian)(dian)氣裝備(bei)用(yong)電(dian)(dian)(dian)(dian)線(xian)(xian)電(dian)(dian)(dian)(dian)纜該類產(chan)品主要特征是:品種規格繁多,應用(yong)范圍(wei)廣(guang)泛,使用(yong)電(dian)(dian)(dian)(dian)壓在1kV及以下較多,面對特殊(shu)場合不(bu)斷衍生(sheng)新的(de)產(chan)品,如耐火線(xian)(xian)纜、阻燃線(xian)(xian)纜、低煙無鹵/低煙低鹵線(xian)(xian)纜、防(fang)(fang)白蟻、防(fang)(fang)老鼠線(xian)(xian)纜、耐油(you)/耐寒/耐溫(wen)/耐磨線(xian)(xian)纜、醫(yi)用(yong)/農(nong)用(yong)/礦用(yong)線(xian)(xian)纜、薄壁電(dian)(dian)(dian)(dian)線(xian)(xian)等(deng)。
(4)、通訊電(dian)纜及光(guang)(guang)纖(簡略(lve)介紹)隨(sui)著近二(er)十多年來(lai),通訊行業的(de)(de)飛速(su)發(fa)(fa)展(zhan),產品也有驚人的(de)(de)發(fa)(fa)展(zhan)速(su)度(du)。從(cong)過(guo)去的(de)(de)簡單的(de)(de)電(dian)話(hua)電(dian)報線纜發(fa)(fa)展(zhan)到(dao)幾(ji)千對的(de)(de)話(hua)纜、同軸(zhou)纜、光(guang)(guang)纜、數據電(dian)纜,甚(shen)至(zhi)組合(he)通訊纜等。
該類產品結(jie)構尺寸(cun)通(tong)常(chang)較(jiao)小而均勻,制造精度要求(qiu)高。
(5)、電(dian)磁線(xian)(繞組(zu)線(xian))主(zhu)要(yao)用于(yu)各種電(dian)機、儀器儀表等。
電(dian)線電(dian)纜的衍生(sheng)/新(xin)產(chan)品(pin)
電(dian)線電(dian)纜的(de)衍生/新(xin)產品主要(yao)(yao)是因應用場合(he)(he)、應用要(yao)(yao)求(qiu)不同(tong)及裝(zhuang)備(bei)(bei)的(de)方便性和降低裝(zhuang)備(bei)(bei)成本等(deng)的(de)要(yao)(yao)求(qiu),而采用新(xin)材料(liao)、特殊材料(liao)、或(huo)改變產品結構、或(huo)提高工藝要(yao)(yao)求(qiu)、或(huo)將不同(tong)品種的(de)產品進行組(zu)合(he)(he)而產生。
采(cai)用不同材料如(ru)阻燃線纜、低煙無鹵(lu)/低煙低鹵(lu)線纜、防白蟻(yi)、防老(lao)鼠線纜、耐油/耐寒(han)/耐溫線纜等(deng);
改變產品結構如:耐(nai)火電纜等(deng);
提高(gao)工藝要求如:醫用線纜等;
組合產品如:OPGW等;
方便安裝(zhuang)和降低(di)裝(zhuang)備(bei)成本如:預制(zhi)分支(zhi)電纜等。
32、母線裝置施工完,應進行(xing)哪些檢查(cha)?
答(da):應進行下列檢查:
(1)金屬(shu)構件的加工、配制、焊接(jie)螺接(jie)應符合規定;
(2)各部螺(luo)栓(shuan)、墊圈、開口銷等零部件應齊全可靠;
(3)母(mu)線配(pei)制及安裝架應符合規(gui)定(ding),相間及對地電氣(qi)距離符合要求;
(4)瓷(ci)件(jian)、鐵件(jian)及膠(jiao)合處應完整(zheng),充油套管應無滲油,油位(wei)正常;
(5)油漆完整,相(xiang)色正(zheng)確(que),接地良好。
33、在35kv及以下電力電纜接頭(tou)中,改善其護套斷開處(chu)電場分布的方法有幾種(請(qing)列出(chu)五種),并簡述其方法。
答(da):(1)脹(zhang)喇叭口:在鉛包(bao)割斷處把鉛包(bao)邊緣撬起(qi),成喇叭狀,其(qi)邊緣應光滑(hua)、圓整、對稱。
(2)預留(liu)統包(bao)絕(jue)緣(yuan):在(zai)鉛包(bao)切口至(zhi)電纜芯(xin)線(xian)分開點之間留(liu)有一段統包(bao)絕(jue)緣(yuan)紙。
(3)切除(chu)半(ban)(ban)導(dao)電紙:將半(ban)(ban)導(dao)電紙切除(chu)到喇叭(ba)口以(yi)下。
(4)包(bao)(bao)繞應力(li)錐:用(yong)絕緣(yuan)包(bao)(bao)帶和(he)導(dao)電(dian)金(jin)屬材料包(bao)(bao)成錐形,人為地將屏蔽(bi)層擴大(da),以改善電(dian)場分布。
(5)等(deng)電位法:對于干(gan)包型(xing)或交(jiao)聯聚乙烯(xi)電纜頭,在(zai)各線芯(xin)概(gai)況絕緣表面上包一段金屬帶,并將其連接在(zai)一起。
(6)裝設應(ying)力控制管:對于35kv及發下熱縮(suo)管電纜頭,首先從線芯銅屏蔽(bi)層末端方向經半(ban)導體帶(dai)至線芯絕緣(yuan)概況包繞2層半(ban)導體帶(dai),然后將相(xiang)應(ying)規格折應(ying)力管,套在銅屏蔽(bi)的(de)末端處,熱縮(suo)成形。
34、電纜(lan)支(zhi)架的加(jia)工應符合(he)哪些(xie)要(yao)求?
答:(1)鋼材應平直,無明顯扭曲,下料誤差應在5mm范圍內,切口應無卷邊,毛剌;
(2)支(zhi)架應焊接牢固(gu),無顯蓍(shi)變形,各橫(heng)撐間的垂(chui)直凈距與設(she)計偏差不應大于5mm;
(3)金屬(shu)支架必須進行防(fang)(fang)腐(fu)(fu)處理,位(wei)于(yu)濕熱、鹽、霧以及(ji)有(you)化學腐(fu)(fu)蝕地區時,應根據設(she)計作特殊(shu)的防(fang)(fang)腐(fu)(fu)處理。
35、列舉(ju)出你熟悉的電纜架。
答:拼焊式E型架(jia)(jia)(jia)(jia)、裝配式E型架(jia)(jia)(jia)(jia)、橋式電纜架(jia)(jia)(jia)(jia)、電纜托架(jia)(jia)(jia)(jia)、掛鉤式支架(jia)(jia)(jia)(jia)、單根電纜支架(jia)(jia)(jia)(jia)等。
36、敷(fu)設電纜應滿(man)足哪些要求?
答:應滿(man)足以下要求:
(1)安(an)全運行(xing)方面,盡(jin)可(ke)能避免各種(zhong)外(wai)來損(sun)壞,提高電(dian)纜線(xian)路的供電(dian)可(ke)靠性;
(2)經濟方(fang)面(mian),從(cong)投資最省(sheng)的方(fang)面(mian)考慮;
(3)施工(gong)方(fang)面,電纜線路(lu)的(de)路(lu)徑必須便于旋工(gong)和投(tou)運后(hou)的(de)維修。
37、制作電纜終端(duan)頭或中間接頭的絕緣材(cai)料(liao)有哪(na)些?
答:有絕(jue)(jue)緣膠、絕(jue)(jue)緣帶、絕(jue)(jue)緣管(guan)、絕(jue)(jue)緣手套、絕(jue)(jue)緣樹脂等。
38、簡述電纜頭(tou)制(zhi)(zhi)作的一(yi)般(ban)操作程(cheng)序。答:(1)制(zhi)(zhi)作前(qian)的準備(bei):包(bao)括○1閱讀(du)安裝說(shuo)明書;○2察看(kan)現場;○3備(bei)料;○4電纜試潮;○5制(zhi)(zhi)作前(qian)測試等。
(2)接(jie)(jie)頭的制(zhi)作(zuo)過(guo)程:包括○1割斷多余電(dian)纜;○2電(dian)纜保護(hu)層的剝切;○3導體連接(jie)(jie);○4包繞絕(jue)(jue)緣(或收(shou)縮管(guan)材);○5安裝接(jie)(jie)頭外殼;○6灌注絕(jue)(jue)緣劑;○7進(jin)行密封處(chu)理等。
(3)制作(zuo)后電氣測試。
39、電(dian)纜保護管的加(jia)工應(ying)符合哪些要求(qiu)?
答:(1)管口應*剌和尖(jian)銳楞角,管口宜做成(cheng)喇叭形。
(2)電纜管(guan)在(zai)彎(wan)制(zhi)后,不應有裂縫和(he)顯著(zhu)的(de)凹癟現象,其彎(wan)扁程度不宜(yi)大于管(guan)子外徑10%;電纜管(guan)的(de)彎(wan)曲半(ban)徑不應小(xiao)于所(suo)穿入(ru)電纜的(de)最小(xiao)允(yun)許彎(wan)曲半(ban)徑。
(3)金(jin)屬(shu)管應(ying)在外表涂防腐(fu)漆或瀝表,鍍鋅(xin)管鋅(xin)層(ceng)剝(bo)落處也應(ying)涂以(yi)防腐(fu)漆。
40、電(dian)纜的(de)排列符合哪些要(yao)求?答:(1)電(dian)力電(dian)纜和控纜不應配置在(zai)同一(yi)層支架上。
(2)高、低(di)壓(ya)電(dian)(dian)纜,強、弱(ruo)電(dian)(dian)控(kong)纜應按須(xu)序(xu)分層配(pei)置(zhi),一(yi)般情況(kuang)宜由上而下(xia),但在含有35kv以上高壓(ya)電(dian)(dian)纜引(yin)入柜盤時,為(wei)滿(man)足彎曲半徑,可由下(xia)面上配(pei)置(zhi)。
41、電纜溝(gou)內敷設電纜的方(fang)法(fa)是什(shen)么?
答:在電(dian)(dian)纜(lan)溝(gou)內敷(fu)設電(dian)(dian)纜(lan)的方法與直埋電(dian)(dian)纜(lan)的敷(fu)設方法相仿,一般可將滑輪放在溝(gou)內,施(shi)放完(wan)畢,將電(dian)(dian)纜(lan)放于溝(gou)底或支架上,并在電(dian)(dian)纜(lan)上綁扎電(dian)(dian)纜(lan)標牌。
42、電(dian)纜敷(fu)設(she)的常用設(she)備(bei)有哪(na)些?
答:(1)空氣壓縮機,主要用來破壞路(lu)面(mian),為(wei)以后敷設(she)電纜作準備;
(2)電(dian)動(dong)卷揚機(ji)或(huo)電(dian)纜(lan)牽引機(ji),主要用來(lai)拖電(dian)纜(lan);
(3)電纜輸送機,配合牽(qian)引機使用來克(ke)服巨大的(de)摩擦力,減(jian)輕對(dui)電纜的(de)損壞;
(4)電(dian)纜(lan)盤放線(xian)支架;
(5)滾輪裝(zhuang)置;
(6)防(fang)捻 ,減鋼絲繩出現的扭曲(qu);
(7)電纜盤制動(dong)裝置;
(8)張(zhang)力(li)計。
43、電纜(lan)溝中支(zhi)(zhi)架(jia)安裝距離的(de)要求如何(he)?答:電纜(lan)固定(ding)于(yu)電纜(lan)溝和(he)隧道的(de)墻上(shang),水平裝置(zhi)時,當(dang)電纜(lan)外徑等于(yu)或小于(yu)50mm時應每(mei)(mei)(mei)隔1m加一支(zhi)(zhi)撐;外徑大于(yu)50mm的(de)電纜(lan)每(mei)(mei)(mei)隔0.6m加一支(zhi)(zhi)撐;排成三角形的(de)單電纜(lan),每(mei)(mei)(mei)隔1m應用綁帶(dai)扎(zha)牢,垂(chui)直裝置(zhi)時,每(mei)(mei)(mei)隔1~1.5m加以固定(ding)。
44、如何處(chu)理電(dian)(dian)力電(dian)(dian)纜與(yu)控制(zhi)電(dian)(dian)纜在同一托架(jia)的安裝?
答:電力電纜(lan)與(yu)控制電纜(lan)一般不應(ying)敷(fu)設(she)在同一托架內,當電纜(lan)較少而將控纜(lan)與(yu)電力電纜(lan)敷(fu)設(she)在同一托架內時,應(ying)用隔(ge)板隔(ge)開(kai)。
45、電纜隧道內如何裝(zhuang)設接(jie)地線(xian)?
答(da):隧(sui)道和(he)溝的(de)(de)全長應(ying)(ying)裝(zhuang)設連(lian)(lian)續(xu)的(de)(de)接(jie)(jie)(jie)(jie)地(di)(di)線,接(jie)(jie)(jie)(jie)地(di)(di)線應(ying)(ying)和(he)所(suo)有(you)(you)的(de)(de)支架(jia)相(xiang)連(lian)(lian),兩頭和(he)接(jie)(jie)(jie)(jie)地(di)(di)極連(lian)(lian)通。接(jie)(jie)(jie)(jie)地(di)(di)線的(de)(de)規格(ge)應(ying)(ying)符合設計要求(qiu)(qiu)。電纜鉛(qian)包和(he)鎧裝(zhuang)除了有(you)(you)絕緣要求(qiu)(qiu)外,應(ying)(ying)全部相(xiang)互連(lian)(lian)接(jie)(jie)(jie)(jie)并和(he)接(jie)(jie)(jie)(jie)地(di)(di)線相(xiang)連(lian)(lian),電纜架(jia)和(he)接(jie)(jie)(jie)(jie)地(di)(di)線均應(ying)(ying)涂(tu)防銹漆或鍍鋅。
46、對于電(dian)纜(lan)孔洞(dong)的防火封(feng)堵有何(he)要求?
答(da):對于較大的(de)電纜貫(guan)穿孔洞,如電纜貫(guan)穿樓板(ban)處等(deng),采(cai)用防(fang)(fang)火(huo)堵(du)(du)(du)(du)料封堵(du)(du)(du)(du)時,應根據(ju)實際情況,先在電纜表(biao)面涂(tu)四至六層防(fang)(fang)火(huo)涂(tu)料,長度自孔洞以(yi)下1.5m左右,再用耐(nai)火(huo)材(cai)料加工成具有一定強度的(de)板(ban)托防(fang)(fang)火(huo)堵(du)(du)(du)(du)料,保證封堵(du)(du)(du)(du)后牢固并(bing)便于更換電纜時拆裝,封堵(du)(du)(du)(du)密實無孔隙以(yi)有效地堵(du)(du)(du)(du)煙(yan)堵(du)(du)(du)(du)火(huo)。
47、噴燈點火前應注(zhu)意哪(na)些檢查(cha)?
答:應進行下列(lie)各項檢查:
(1)打氣筒(tong)是(shi)否漏(lou)油或滲油,油桶及(ji)噴嘴處(chu)是(shi)否漏(lou)油、漏(lou)氣;
(2)油(you)(you)桶內的油(you)(you)量是(shi)否超過油(you)(you)桶容量的3/4,加油(you)(you)的螺絲塞是(shi)否擰緊。
48、使用噴燈(deng)應注意哪些事項?
答(da):(1)噴燈更大 注油量為油筒容積的3/4;
(2)開始打氣壓力不要太(tai)大,點燃后火焰由黃(huang)變(bian)藍即可使(shi)用;
(3)周圍(wei)不得有易燃物(wu),空(kong)氣要流通;
(4)停用時先(xian)關閉調節開關,火熄后,慢慢旋松(song)油(you)孔蓋放氣,空氣放完后,要要旋松(song)調節開關,完全(quan)冷(leng)卻后再旋松(song)孔蓋;
(5)煤油噴(pen)(pen)燈與汽油噴(pen)(pen)燈要分開使(shi)用(yong)。
49、手(shou)動油壓(ya)鉗(qian)有何用途?如何操作?
答:兩根導(dao)(dao)線(xian)的(de)連(lian)接(jie)通常(chang)是將兩導(dao)(dao)線(xian)端穿入相同材料制成的(de)壓(ya)(ya)(ya)(ya)管中,用壓(ya)(ya)(ya)(ya)接(jie)鉗擠壓(ya)(ya)(ya)(ya)數個坑,使導(dao)(dao)線(xian)連(lian)接(jie)在一(yi)(yi)起(qi),壓(ya)(ya)(ya)(ya)接(jie)時(shi),手(shou)柄向(xiang)(xiang)上抬起(qi)時(shi),柱(zhu)塞(sai)向(xiang)(xiang)外移動(dong),進(jin)油(you)(you)閥(fa)下腔(qiang)產生真空,油(you)(you)箱內的(de)油(you)(you)進(jin)入柱(zhu)塞(sai)腔(qiang)。手(shou)柄下壓(ya)(ya)(ya)(ya)時(shi),柱(zhu)塞(sai)向(xiang)(xiang)內移動(dong),油(you)(you)受壓(ya)(ya)(ya)(ya)后(hou),使進(jin)油(you)(you)閥(fa)關閉,打(da)開出油(you)(you)閥(fa),使油(you)(you)壓(ya)(ya)(ya)(ya)進(jin)入液壓(ya)(ya)(ya)(ya)缸,推動(dong)活塞(sai)和陽模,陽、陰模之(zhi)間放有壓(ya)(ya)(ya)(ya)接(jie)管,當壓(ya)(ya)(ya)(ya)接(jie)被擠壓(ya)(ya)(ya)(ya)的(de)坑深到一(yi)(yi)定值時(shi),開啟回油(you)(you)閥(fa),活塞(sai)自(zi)動(dong)返(fan)回,壓(ya)(ya)(ya)(ya)完一(yi)(yi)個坑后(hou),移動(dong)壓(ya)(ya)(ya)(ya)鉗,再壓(ya)(ya)(ya)(ya)下一(yi)(yi)個。
50、常用低壓電(dian)力(li)電(dian)纜按絕緣和保護層的不同,主要(yao)可(ke)分為哪幾類(lei)?
答:(1)油浸紙絕緣鉛包(或鋁包)電力(li)電纜;
(2)不(bu)滴流(liu)油浸紙絕緣電力電纜;
(3)聚氯(lv)乙(yi)烯絕緣(yuan)聚氯(lv)乙(yi)烯護套電力(li)電纜;
(4)交聯聚(ju)氯乙(yi)烯絕緣聚(ju)乙(yi)烯護套電力電纜;
(5)交聯聚(ju)氯乙(yi)烯絕緣聚(ju)氯乙(yi)烯護套電(dian)力電(dian)纜;
(6)橡(xiang)皮絕(jue)緣(yuan)電(dian)力電(dian)纜(lan)。
51、常用(yong)絕(jue)緣材料的類(lei)別哪些?舉例說明?
答:(1)無機絕緣材料:有(you)云母、石棉(mian)、大理石、瓷器(qi)、玻璃等;
(2)有(you)機(ji)絕緣材(cai)料:有(you)樹脂、橡膠(jiao)、紙、麻、棉紗等;
(3)混(hun)合絕緣(yuan)材料:用以上絕緣(yuan)材料加工而成(cheng)型的名種絕緣(yuan)材料。
52、在哪種情況下采用排管敷設(she)?有什(shen)么優(you)點(dian)?
答:排管敷設(she)一般用(yong)在與其他建(jian)(jian)筑(zhu)物、公(gong)路(lu)(lu)或鐵(tie)路(lu)(lu)相(xiang)交叉的地方,有(you)時(shi)也在建(jian)(jian)筑(zhu)物密集區內采用(yong)。主要優點是占地少,能(neng)承受大(da)的荷重,電纜(lan)相(xiang)互(hu)間互(hu)不影(ying)響(xiang),比較(jiao)安(an)全。
53、何謂(wei)電纜長期允許(xu)載(zai)流量?
答:電纜長(chang)(chang)期允許載流(liu)(liu)量(liang)是(shi)指在電纜內(nei)通過規定(ding)電流(liu)(liu)時,在熱穩(wen)定(ding)后,電纜導體達到長(chang)(chang)期允許工作(zuo)溫(wen)度時的(de)電流(liu)(liu)數值。
54、決定電纜(lan)長期允許載(zai)流量的因素有哪些?
答:有以下三個(ge)因素(su)決定:
(1)電纜的長(chang)期容許(xu)工作溫度;
(2)電纜本身(shen)的散熱性能;
(3)電纜裝置情(qing)況及周圍環境的散(san)熱條件。
55、電(dian)纜的敷設方式有幾(ji)種?
答:有(you)以下幾(ji)種:
(1)直埋在(zai)地下;
(2)安(an)裝在電纜溝內;
(3)安裝在地下隧道(dao)內;
(4)安(an)裝在建筑(zhu)物(wu)內部墻(qiang)上(shang)或(huo)天(tian)棚上(shang);
(5)安裝在橋架上(shang);
(6)敷設在排管內(nei);
(7)敷設(she)在水底。
56、如何進行(xing)電纜管的連(lian)接工作?
答:電纜管(guan)連(lian)接(jie)(jie)(jie)時,必須用扣和(he)管(guan)接(jie)(jie)(jie)頭連(lian)接(jie)(jie)(jie),如采用焊(han)接(jie)(jie)(jie)時,不(bu)能直接(jie)(jie)(jie)對(dui)焊(han),連(lian)接(jie)(jie)(jie)處要(yao)套上一段粗管(guan)再進行焊(han)接(jie)(jie)(jie),以免焊(han)渣掉入(ru)管(guan)內。
57、制作電纜頭時(shi),對上下扳彎(wan)電纜芯線有何(he)要求?
答(da):扳彎(wan)線(xian)(xian)芯時(shi),不得損(sun)傷紙絕(jue)緣,芯線(xian)(xian)的彎(wan)曲(qu)半(ban)徑不得小于電纜線(xian)(xian)芯的10倍。制作時(shi)要特(te)別小心(xin),應(ying)使(shi)線(xian)(xian)芯彎(wan)曲(qu)部分均勻(yun)受力,否(fou)則極易損(sun)傷絕(jue)緣紙。
58、簡(jian)述塑料電纜的熱(re)收縮密封法。
答:熱(re)(re)縮(suo)法適(shi)用(yong)(yong)于中、低壓橡、塑(su)電纜接頭(tou)和(he)終端頭(tou)的(de)密封,也可適(shi)用(yong)(yong)于不滴流(liu)和(he)黏性(xing)浸漬絕緣電纜。采用(yong)(yong)交聯聚乙烯型和(he)硅橡膠(jiao)型兩(liang)大類(lei)遇熱(re)(re)后(hou)能(neng)均勻(yun)收(shou)縮(suo)的(de)熱(re)(re)收(shou)縮(suo)管。將(jiang)(jiang)這種管材套于預定(ding)的(de)粘合密封部(bu)位,并在粘和(he)部(bu)位涂上(shang)熱(re)(re)熔膠(jiao),當加熱(re)(re)到一定(ding)溫度后(hou),熱(re)(re)縮(suo)管將(jiang)(jiang)收(shou)縮(suo),同時熱(re)(re)熔膠(jiao)熔化(hua),待(dai)自然冷卻后(hou)即形成一道(dao)良好的(de)密封封層。
59、用電動(dong)彎(wan)管機彎(wan)制電纜保護管時應注意(yi)什么?
答:(1)彎管機應由(you)了解其性(xing)能并熟(shu)悉操(cao)作知識的人員操(cao)作;
(2)使用(yong)前必須(xu)進(jin)行檢查,按鈕、操作把手(shou)、行程開關應完好,彎(wan)管機必須(xu)可(ke)靠接地;
(3)選用(yong)符合要(yao)求(qiu)的模具(ju),確定好(hao)所需要(yao)的彎曲(qu)半徑;
(4)施工場地(di)周圍,應有充足的活(huo)動范圍;
(5)使用時待空轉正常后,方可帶負荷工作,運行中(zhong),嚴禁用手腳接觸(chu)其轉動部分(fen);
(6)工作完(wan)畢應(ying)及時停電,釋放油壓。
60、電纜(lan)清冊的內(nei)容及電纜(lan)編號的含義是什么(me)?
答:電纜清冊是施(shi)放電纜和指導施(shi)工的依據,運(yun)行(xing)維(wei)護的檔案資料。應(ying)列入(ru)每根電纜的編號、起始點、型(xing)號、規格(ge)、長(chang)度,并分類統計(ji)出總長(chang)度,控纜還應(ying)列出每根電纜的備(bei)用(yong)芯。
電(dian)(dian)纜(lan)編(bian)號(hao)是識(shi)別電(dian)(dian)纜(lan)的(de)標(biao)志(zhi),故要求全廠編(bian)號(hao)不重復,并且(qie)有一定的(de)含義(yi)和(he)規律,能(neng)表(biao)達電(dian)(dian)纜(lan)的(de)特征。
61、電纜(lan)目前采用(yong)的(de)敷設方法可分(fen)為幾類(lei)?
答:(1)人(ren)(ren)工敷(fu)設,即采用人(ren)(ren)海(hai)戰(zhan)術,在一人(ren)(ren)或多人(ren)(ren)協調指揮下,按規定(ding)進行(xing)敷(fu)設;
(2)機(ji)械(xie)化敷(fu)設(she),即采用滾輪、牽引(yin)器(qi)、輸送機(ji),通(tong)過一同步電源(yuan)進行控制,比較安全(quan);
(3)人(ren)工和(he)機械相(xiang)結合,有些現場由于轉彎較多,施工難度大(da),全用機械較困難,所(suo)以采用此法。
62、控制二次回路接(jie)線應(ying)符合哪些要求?
答:(1)按圖施工接線正確;
(2)導線的電氣連接應(ying)牢固可(ke)靠;
(3)盤柜內(nei)的導線不應(ying)有接頭,導線芯線應(ying)無損傷;
(4)電纜芯線端部應標明其回路編號,編號應正(zheng)確,字(zi)跡(ji)清晰(xi)且不易(yi)脫(tuo)色;
(5)配線(xian)應(ying)整齊、清晰、美觀,導線(xian)絕(jue)緣應(ying)良(liang)好、無(wu)損;
(6)每個接線端子(zi)的每側接線宜為一根,最多不得超過兩根。
63、電(dian)纜排管有何要求?
答:(1)排(pai)管頂部至地(di)面距離,在廠(chang)房內為0.2m,人行道下(xia)為0.5m,一般(ban)地(di)區(qu)為0.7m;
(2)在變更方(fang)向及(ji)分支處均(jun)應裝置排管井坑,長(chang)度超過30mm時也應加(jia)設井坑;
(3)井坑深度不(bu)小于0.8m,人孔(kong)直徑(jing)不(bu)小于0.7mm;
(4)排(pai)管應有傾向井坑(keng)0.5%~1%的排(pai)水坡度。
64、對于電纜導(dao)體連接點的電阻有何要求?
答:要求連接點(dian)的(de)電阻(zu)小而且穩(wen)定(ding),連接點(dian)的(de)電阻(zu)與相同長度、相同截(jie)面的(de)導體之比值(zhi)(zhi),對(dui)于(yu)新安裝的(de)終(zhong)端頭(tou)和中(zhong)間頭(tou),應(ying)不(bu)大(da)于(yu)1;對(dui)于(yu)運行中(zhong)的(de)終(zhong)端頭(tou)和中(zhong)間頭(tou)這個比值(zhi)(zhi)不(bu)應(ying)大(da)于(yu)1.2。
65、電纜接頭和中間頭的設計應滿足哪些要(yao)求?
答:應滿足(zu)的要(yao)求有:
(1)耐(nai)壓強度高(gao),導體(ti)連接好;
(2)機械強(qiang)度大,介質損失小;
(3)結構(gou)簡(jian)單,密封性(xing)強。
66、什么是電(dian)纜(lan)故障?有幾(ji)種常(chang)見的(de)類型?
答:電纜(lan)故(gu)障(zhang)(zhang)是(shi)指電纜(lan)在預(yu)防性試驗時發生絕(jue)緣(yuan)擊(ji)穿或在運行(xing)中,因絕(jue)緣(yuan)擊(ji)穿、導線(xian)燒斷等(deng)而迫使電纜(lan)線(xian)路(lu)(lu)停(ting)電的故(gu)障(zhang)(zhang)。常(chang)見的故(gu)障(zhang)(zhang)有接地(di)故(gu)障(zhang)(zhang)、短路(lu)(lu)故(gu)障(zhang)(zhang)、斷線(xian)故(gu)障(zhang)(zhang)、閃絡性故(gu)障(zhang)(zhang)和混合型故(gu)障(zhang)(zhang)等(deng)。
67、如何處理電纜線(xian)路的單(dan)相接地故(gu)障?
答(da):電纜線路單相(xiang)接地故(gu)障(zhang)(zhang)一(yi)(yi)般來說,電纜導(dao)體的損(sun)傷(shang)只是局部的,如(ru)果屬于(yu)機械損(sun)傷(shang),而故(gu)障(zhang)(zhang)點(dian)附近的土壤又較干燥(zao)時,一(yi)(yi)般可進(jin)行(xing)局部修理,加添(tian)一(yi)(yi)只假接頭,即不(bu)將(jiang)(jiang)電纜芯鋸斷,僅將(jiang)(jiang)故(gu)障(zhang)(zhang)點(dian)絕緣加強(qiang)后密封即可。
68、電力電纜在敷設(she)前應進行哪些試驗和檢查(cha)?
答:敷設前應(ying)檢查電(dian)(dian)纜(lan)的型(xing)號、規格(ge)及長度是否(fou)符合要求,是否(fou)有(you)外力損(sun)傷,低(di)壓電(dian)(dian)纜(lan)用1000V兆歐表遙測(ce)絕緣電(dian)(dian)阻,阻值一般(ban)不低(di)于10MΩ,高(gao)壓電(dian)(dian)纜(lan)用2500V兆歐表搖測(ce)阻值一般(ban)不抵(di)于400MΩ。
69、主廠房(fang)內敷設電纜時一般應注意(yi)什(shen)么?
答:在主廠房內敷設電纜時一般應(ying)注意:
(1)凡引至集控(kong)室的(de)控(kong)制電(dian)纜宜(yi)架空敷設;
(2)6KV電纜宜用隧(sui)道(dao)或排管敷(fu)設,地下水(shui)位(wei)高處亦可架空(kong)或用排管敷(fu)設;
(3)380V電纜當(dang)兩端電纜在(zai)零米時宜(yi)用隧道、溝或排管,當(dang)一端設備在(zai)上、一端在(zai)下(xia)(xia)時,可部分架空(kong)敷設,當(dang)地下(xia)(xia)水位(wei)較高(gao)時,宜(yi)架空(kong)。
70、電力(li)電纜的內屏蔽(bi)層(ceng)與(yu)外(wai)屏蔽(bi)層(ceng)各在什么部位?采用什么材(cai)料?有何作用?
答:為了(le)使絕緣層(ceng)和電纜導(dao)體(ti)有(you)較(jiao)好(hao)的(de)接觸,消除(chu)導(dao)體(ti)表面(mian)的(de)不光滑引起的(de)導(dao)體(ti)表面(mian)電場強度的(de)增加,一般在導(dao)體(ti)表面(mian)包有(you)金屬(shu)(shu)化紙(zhi)或半導(dao)體(ti)紙(zhi)帶(dai)的(de)內(nei)(nei)屏(ping)(ping)蔽層(ceng)。為了(le)使絕緣層(ceng)和金屬(shu)(shu)護套有(you)較(jiao)好(hao)的(de)接觸,一般在絕緣層(ceng)外(wai)表面(mian)包有(you)外(wai)層(ceng)屏(ping)(ping)蔽層(ceng)。外(wai)屏(ping)(ping)層(ceng)與內(nei)(nei)屏(ping)(ping)層(ceng)的(de)材(cai)料相同,有(you)時還外(wai)扎銅帶(dai)或編織銅絲(si)帶(dai)。
71、簡述環(huan)氧樹脂復合物的構(gou)成及(ji)性能。
答(da):環氧(yang)樹(shu)脂復合物由環氧(yang)樹(shu)脂加(jia)入硬化劑、填充(chong)劑增(zeng)韌(ren)劑和稀釋劑組(zu)成。具有以下性(xing)能:
(1)有足(zu)夠的機械(xie)強度;
(2)電氣(qi)性能優良;
(3)電氣性能穩(wen)定;
(4)與有色金屬有足夠的(de)黏附力;
(5)耐腐蝕性(xing)好;
(6)戶外使用(yong)時,耐(nai)(nai)雨、耐(nai)(nai)光、耐(nai)(nai)濕熱。
72、單芯電纜護套一端接地方式中為什(shen)么必須安裝一條沿電纜平行敷設的回(hui)流線?
答:在金(jin)屬護(hu)(hu)套一端接(jie)(jie)地(di)(di)的(de)(de)(de)電纜線路(lu)(lu)(lu)中,為(wei)確保護(hu)(hu)套中的(de)(de)(de)感應(ying)電壓不超過(guo)允(yun)許(xu)標準,必須安裝一條沿電纜線路(lu)(lu)(lu)平(ping)行(xing)敷設的(de)(de)(de)導體(ti),且導體(ti)的(de)(de)(de)兩端接(jie)(jie)地(di)(di),這種(zhong)導體(ti)稱為(wei)回(hui)流線。當發生單相接(jie)(jie)地(di)(di)故障(zhang)時,接(jie)(jie)地(di)(di)短路(lu)(lu)(lu)電流可以通(tong)過(guo)回(hui)流線流回(hui)系(xi)統中心點,由于通(tong)過(guo)回(hui)流線的(de)(de)(de)接(jie)(jie)地(di)(di)電流產(chan)生的(de)(de)(de)磁(ci)通(tong)抵消了一部分電纜導線接(jie)(jie)地(di)(di)電流所產(chan)生的(de)(de)(de)磁(ci)通(tong),因而可降低(di)短路(lu)(lu)(lu)故障(zhang)時護(hu)(hu)套的(de)(de)(de)感應(ying)電壓。
73、電纜(lan)工程可劃(hua)分為幾(ji)個(ge)項(xiang)目?
答:(1)工地(di)運(yun)輸:包(bao)括工程材料從倉(cang)庫到施工點的裝(zhuang)卸、運(yun)輸和(he)空(kong)車回程。
(2)地方(fang)工程:包括(kuo)路面(mian)開挖、隧(sui)、溝道(dao)施工等。
(3)敷設(she)工程:包(bao)括敷設(she)、中(zhong)間頭制(zhi)作(zuo)、掀蓋板、埋(mai)管、校潮、牽引(yin)頭制(zhi)作(zuo)等。
(4)兩(liang)端工(gong)程:包括(kuo)支(zhi)、吊橋架和(he)其基礎的制(zhi)作安裝,終端頭制(zhi)作,油(you)壓力和(he)信號裝置的安裝,名種(zhong)電氣性能測試(shi)等。
(5)塞(sai)止(zhi)工程:包(bao)括(kuo)充油電纜塞(sai)止(zhi)頭(tou)制作,供油箱(xiang)、自動排水及信(xin)號裝(zhuang)置的安裝(zhuang)等。
(6)接(jie)地工程:包括絕緣(yuan)接(jie)頭、換位箱、保(bao)護器、接(jie)地箱安裝等(deng)。
74、電(dian)纜線路的驗收應進行哪些檢查?
答:(1)電(dian)纜規格應符(fu)合規定,排列應整齊(qi),無損傷,標(biao)牌齊(qi)全、正確、清(qing)晰;
(2)電纜(lan)的(de)固定彎曲半(ban)徑、有(you)關距(ju)離(li)及單芯電力電纜(lan)的(de)金(jin)屬護層的(de)接線應符合要(yao)求;
(3)電(dian)纜(lan)終(zhong)端、中間頭不滲漏油(you),安裝(zhuang)牢(lao)固,充油(you)電(dian)纜(lan)油(you)壓及表計整定值應(ying)符(fu)合要求;
(4)接地良好;
(5)電纜終端相(xiang)色正確,支架等的金(jin)屬部件油漆完整;
(6)電(dian)纜(lan)溝及隧道內、橋架上應無(wu)雜物,蓋板齊全。
75、電纜線路正(zheng)序阻抗測量過(guo)程中有什么要求?
答(da):電(dian)(dian)纜(lan)導體的(de)交流電(dian)(dian)阻和電(dian)(dian)纜(lan)三相同感抗的(de)相量(liang)和稱為正序阻抗。
電(dian)纜線路的(de)正序阻(zu)抗一(yi)般(ban)可(ke)在電(dian)纜盤上(shang)直接(jie)測量(liang),測量(liang)時(shi)(shi)(shi)一(yi)般(ban)使用較(jiao)低(di)的(de)電(dian)壓(ya),因(yin)此,需要用降壓(ya)變壓(ya)器(qi)進(jin)行降壓(ya),降壓(ya)器(qi)采(cai)用星形接(jie)線,容(rong)量(liang)一(yi)般(ban)為10kVA以上(shang),有(you)較(jiao)廣(guang)的(de)電(dian)壓(ya)調節范圍,測量(liang)時(shi)(shi)(shi)交流(liu)(liu)電(dian)源應比較(jiao)穩(wen)定(ding),以保證測量(liang)時(shi)(shi)(shi)電(dian)流(liu)(liu)達到(dao)規(gui)定(ding)的(de)要求,實際電(dian)壓(ya)表(biao)的(de)讀(du)數(shu)值必(bi)須是(shi)電(dian)纜端的(de)電(dian)壓(ya),試(shi)驗電(dian)流(liu)(liu)更(geng)好 接(jie)近電(dian)纜長期允許載流(liu)(liu)量(liang),測讀(du)各表(biao)計的(de)數(shu)值時(shi)(shi)(shi),合上(shang)電(dian)流(liu)(liu)后同(tong)時(shi)(shi)(shi)讀(du)取三個表(biao)的(de)數(shu)值。
76、根據《電業生產安全規(gui)定》,電氣工作人員必須具備的條件(jian)是什么?
答:必須具備下列條(tiao)件:
(1)經(jing)醫生鑒定身體健康,無妨礙工作的病癥(zheng);
(2)具備必要的(de)電氣知識,按(an)其(qi)職務和工作(zuo)性質掌握(wo)相關的(de)規程(cheng)、專業(ye)技(ji)術及安全(quan)操(cao)作(zuo)技(ji)術,并經(jing)考試(shi)合(he)格;
(3)熟練掌握觸(chu)電(dian)急救(jiu)方法。
77、電(dian)纜在運輸裝卸過(guo)程(cheng)中應注意什么?
答:(1)在運輸裝卸過程中,不應使電(dian)(dian)(dian)纜(lan)(lan)及電(dian)(dian)(dian)纜(lan)(lan)盤受(shou)到損傷,嚴禁將電(dian)(dian)(dian)纜(lan)(lan)盤直接由車上(shang)推下(xia),電(dian)(dian)(dian)纜(lan)(lan)般不應平(ping)放運輸,平(ping)放貯存。
(2)運輸或滾動(dong)電纜(lan)盤前,必須保證(zheng)電纜(lan)盤牢固,電纜(lan)繞緊、充油(you)(you)電纜(lan)至壓力油(you)(you)箱間的油(you)(you)管應固定,不得損傷,壓力油(you)(you)箱應牢固,壓力指示應符(fu)合要(yao)求(qiu)。
78、電(dian)纜防(fang)火有哪些措施?
答:(1)采用阻燃電纜;
(2)采用防火(huo)電纜托架;
(3)采(cai)用防(fang)火涂料;
(4)電纜隧道(dao)、夾層(ceng)出口等處設置防火(huo)隔(ge)墻、防火(huo)擋板(ban);
(5)架空電纜應(ying)避開油管(guan)道(dao)、防爆門,否則應(ying)有要取局部(bu)穿管(guan)或隔熱防火措施(shi)。
79、選(xuan)擇電力電纜的截面(mian)應(ying)從哪幾個(ge)方(fang)面(mian)考(kao)慮?
答(da):應(ying)考慮如(ru)下幾個方(fang)面:
(1)電纜長期(qi)允許(xu)通過的工作(zuo)電流;
(2)一旦短路時(shi)的(de)熱穩定性(xing);
(3)線(xian)路上的電壓降不能超(chao)出允許工(gong)作范圍。
80、電(dian)力電(dian)纜和架空線比較有哪些優(you)點?
答:(1)運(yun)行可靠,由(you)于安裝在地下等隱蔽處,受(shou)外力(li)破(po)壞小,發生故(gu)障的機會較少,供(gong)電(dian)安全,不會給人(ren)身造(zao)成危(wei)害;
(2)維(wei)護工作量(liang)小,不需(xu)頻繁(fan)的巡檢;
(3)不需(xu)架設桿塔;
(4)有助于(yu)提(ti)高功率(lv)因數。