1、常用(yong)的電線、電纜按(an)用(yong)途分有哪(na)些種類?
答:按(an)用(yong)途可(ke)分為裸(luo)導線、絕(jue)緣電(dian)(dian)(dian)(dian)線、耐熱電(dian)(dian)(dian)(dian)線、屏蔽電(dian)(dian)(dian)(dian)線、電(dian)(dian)(dian)(dian)力電(dian)(dian)(dian)(dian)纜、控制電(dian)(dian)(dian)(dian)纜、通信(xin)電(dian)(dian)(dian)(dian)纜、射頻電(dian)(dian)(dian)(dian)纜等(deng)。
2、絕緣電線有哪幾種(zhong)?
答:常有的絕緣(yuan)電(dian)(dian)(dian)線(xian)有以(yi)下(xia)幾種:聚(ju)氯乙(yi)(yi)烯絕緣(yuan)電(dian)(dian)(dian)線(xian)、聚(ju)氯乙(yi)(yi)烯絕緣(yuan)軟線(xian)、丁腈(jing)聚(ju)氯乙(yi)(yi)烯混(hun)合物(wu)絕緣(yuan)軟線(xian)、橡皮絕緣(yuan)電(dian)(dian)(dian)線(xian)、農用(yong)地(di)下(xia)直埋鋁芯塑料絕緣(yuan)電(dian)(dian)(dian)線(xian)、橡皮絕緣(yuan)棉(mian)紗(sha)紡(fang)織軟線(xian)、聚(ju)氯乙(yi)(yi)烯絕緣(yuan)尼龍護套電(dian)(dian)(dian)線(xian)、電(dian)(dian)(dian)力和照明用(yong)聚(ju)氯乙(yi)(yi)烯絕緣(yuan)軟線(xian)等。
3、電纜橋架適合于何種場合?
答:電(dian)纜橋架適用于一(yi)般工礦企業室(shi)內外架空敷設(she)電(dian)力(li)電(dian)纜、控制(zhi)電(dian)纜,亦可用于電(dian)信、廣播電(dian)視等(deng)部門在室(shi)內外架設(she)。
4、電(dian)纜(lan)附件有哪些?
答:常(chang)用的電(dian)附件有電(dian)纜終端(duan)接(jie)線盒、電(dian)纜中間接(jie)線盒、連(lian)接(jie)管及接(jie)線端(duan)子、鋼(gang)板接(jie)線槽、電(dian)纜橋架等。
5、什么(me)叫(jiao)電纜(lan)中間(jian)接(jie)頭?
答:連接電(dian)(dian)纜(lan)與電(dian)(dian)纜(lan)的導體、絕緣屏(ping)蔽層和保護層,以使電(dian)(dian)纜(lan)線路連接的裝置,稱為電(dian)(dian)纜(lan)中(zhong)間接頭。
6、什么叫電氣主(zhu)接線?
答:電氣(qi)主接線(xian)是發電廠(chang)、變電所中主要(yao)電氣(qi)設備(bei)和(he)母線(xian)的(de)連接方式,包括主母線(xian)和(he)廠(chang)用電系統按一定(ding)的(de)功能(neng)要(yao)求的(de)連接方式。
7、在選擇電力電纜(lan)的截面時,應(ying)遵(zun)照哪些規(gui)定?
答:電(dian)(dian)(dian)力(li)電(dian)(dian)(dian)纜的(de)(de)選(xuan)擇應(ying)遵照以(yi)下原則:(1)電(dian)(dian)(dian)纜的(de)(de)額(e)定(ding)電(dian)(dian)(dian)壓要(yao)大于(yu)或(huo)(huo)等(deng)于(yu)安裝點供電(dian)(dian)(dian)系統的(de)(de)額(e)定(ding)電(dian)(dian)(dian)壓;(2)電(dian)(dian)(dian)纜持續容許(xu)電(dian)(dian)(dian)流應(ying)等(deng)于(yu)或(huo)(huo)大于(yu)供電(dian)(dian)(dian)負載的(de)(de)更大 持續電(dian)(dian)(dian)流;(3)線芯截面要(yao)滿足供電(dian)(dian)(dian)系統短(duan)路時(shi)的(de)(de)穩定(ding)性的(de)(de)要(yao)求;(4)根據電(dian)(dian)(dian)纜長度驗算電(dian)(dian)(dian)壓降(jiang)是否符合要(yao)求;(5)線路末端(duan)的(de)(de)最小(xiao)短(duan)路電(dian)(dian)(dian)流應(ying)能使保護裝置可靠(kao)的(de)(de)動作。
8、交(jiao)聯聚乙(yi)烯電(dian)纜和(he)油紙電(dian)纜比較有哪些(xie)優點?
答:(1)易安裝,因為它允許最小彎曲半(ban)徑小、且重(zhong)量(liang)輕;(2)不受線路落差*;(3)熱性(xing)能(neng)好,允許工(gong)作溫(wen)度高、傳(chuan)輸(shu)容量(liang)大;(4)電(dian)纜附件簡(jian)單(dan),均(jun)為干(gan)式結構;(5)運行(xing)維護(hu)簡(jian)單(dan),無漏油問題;(6)價格較低(di);(7)可靠性(xing)高、故障率低(di);(8)制(zhi)造工(gong)序少、工(gong)藝簡(jian)單(dan),經濟效益顯著。
9、固(gu)定交流(liu)單(dan)芯電纜的夾具有什(shen)么要求?為什(shen)么?
答:夾具應(ying)無鐵(tie)件(jian)構成閉合磁(ci)(ci)路,這是因為(wei)當電(dian)纜線芯通(tong)過電(dian)流(liu)時(shi),在其周圍產生(sheng)磁(ci)(ci)力線,磁(ci)(ci)力線與通(tong)過線芯的電(dian)流(liu)大(da)小成正比,若使用鐵(tie)件(jian)等導(dao)磁(ci)(ci)材(cai)料,根據電(dian)磁(ci)(ci)感(gan)應(ying)可知,將在鐵(tie)件(jian)中產生(sheng)渦(wo)流(liu)使電(dian)纜發熱,甚(shen)至燒(shao)壞電(dian)纜。所以不可使用鐵(tie)件(jian)作單芯交流(liu)電(dian)纜的固定(ding)夾具。
10、以(yi)下的熱縮電纜(lan)頭的附件的更大 特點(dian)和優點(dian)是什么?
答:熱(re)縮附(fu)件的(de)更大 特點是(shi)用(yong)應力管代替傳統的(de)應力錐,它不僅簡化了(le)施工工藝,還縮小(xiao)了(le)接頭的(de)終(zhong)端的(de)尺寸,安裝方便,省時省工,性能優越,節約金屬。熱(re)縮電纜附(fu)件集灌注(zhu)式(shi)和干(gan)包式(shi)為一體,集合了(le)這兩種(zhong)附(fu)件的(de)優點。
11、電纜敷設(she)前應進行哪些檢查工作?
答(da):(1)支(zhi)架(jia)應(ying)齊(qi)全、油(you)(you)(you)漆完整(zheng)。(2)電纜(lan)型號、電壓、規格(ge)符合設計。(3)電纜(lan)絕緣良(liang)好(hao),當對油(you)(you)(you)紙電纜(lan)的密封有懷疑時,應(ying)進行(xing)受潮判斷;直埋電纜(lan)與小底電纜(lan)應(ying)經直流耐壓試難合格(ge);充(chong)油(you)(you)(you)電纜(lan)的油(you)(you)(you)樣應(ying)試驗合格(ge)。(4)充(chong)油(you)(you)(you)電纜(lan)的油(you)(you)(you)壓不宜低于(yu)1.47MPa。
11、交聯熱收縮電纜附件有哪些優點?
答(da):這是一種新型材(cai)料,它與現在其他類型附件比較(jiao)具有(you)電氣性(xing)能優越、體積小、質量小、安裝簡(jian)便、材(cai)料配(pei)套等優點,另外還具有(you)耐氣候(hou)、抗污穢(hui)性(xing)、阻燃自(zi)熄等能力。
12、對(dui)油紙(zhi)絕緣電力電纜(lan)密封有懷(huai)疑時,如何用較簡單的辦法(fa)檢查(cha)電纜(lan)絕緣紙(zhi)是(shi)否(fou)受潮?
答:把電纜(lan)絕緣紙點燃(ran)或放入150℃左右(you)的電纜(lan)油中檢(jian)查(cha),無(wu)“嘶嘶”聲(sheng)或白色泡(pao)沫出現,說明(ming)未受潮。
13、電纜標志牌應注明什么內容?編(bian)寫有何要求?
答(da):標(biao)志牌上應注明電(dian)纜(lan)線路設計編號、電(dian)纜(lan)型(xing)號、規格及始點,并聯(lian)使(shi)用的電(dian)纜(lan)應有順(shun)序號。要求字跡清晰、不易脫落(luo)。
14、直埋(mai)電纜的方(fang)位標志應設置在哪些(xie)位置?
答:在電(dian)纜兩端,電(dian)纜直線段50~100m處(chu)電(dian)纜接(jie)頭幾電(dian)纜改變方向的彎角處(chu)。
15、制作電(dian)纜接頭用的(de)黃臘綢帶、黑(hei)玻(bo)璃漆帶、無堿玻(bo)璃絲帶等,施(shi)工前如(ru)何(he)進行(xing)排潮處理?
答:(1)恒(heng)(heng)溫干(gan)(gan)燥(zao)(zao)法(fa):將絕緣帶卷(juan)成直徑為25~30mm小(xiao)卷(juan),放(fang)入110~120℃恒(heng)(heng)溫干(gan)(gan)燥(zao)(zao)箱內(nei)烘4~5h,冷卻(que)干(gan)(gan)取出,放(fang)入干(gan)(gan)燥(zao)(zao)的密封筒內(nei)。(2)油(you)浸排潮法(fa):將絕緣帶小(xiao)卷(juan)放(fang)入恒(heng)(heng)溫在120~130℃的電纜油(you)中(zhong),離(li)鍋底保持(chi)30mm距離(li),經一定時(shi)間后油(you)面不再產(chan)生泡(pao)沫后取出,裝入貯有電纜油(you)的桶中(zhong),油(you)位(wei)應超過所有裝入的物體并將其密封。
16、電纜外(wai)護層(ceng)的作用是什么?
答:保(bao)護(hu)內護(hu)層不受機械損傷和化學(xue)腐蝕,增強(qiang)機械強(qiang)度。
17、室外電纜溝應符合哪些要求?
答:電纜溝上部應(ying)比地面稍(shao)高,加蓋用混凝土制(zhi)作的蓋板,電纜應(ying)平敷在支架(jia)上,有良(liang)好的排水管。
18、電纜內護層的作用是什么(me)?
答;使(shi)絕緣(yuan)層(ceng)(ceng)不(bu)會與水、空氣(qi)或其(qi)他物(wu)體(ti)接觸,防止(zhi)絕緣(yuan)受潮和絕緣(yuan)層(ceng)(ceng)不(bu)受機械傷(shang)害。
19、使用鋼絲鉗(qian)時(shi)應(ying)注意(yi)些什么(me)?
答:使(shi)用前,一定(ding)要(yao)檢查絕緣柄的絕緣是否完(wan)好無損,使(shi)用時不可用鋼絲鉗剪切超過規格所允許的金屬線材,并(bing)禁止(zhi)用鋼絲鉗代替錘子(zi)敲打工(gong)具,以(yi)免損壞(huai)。
20、什么叫(jiao)絕緣強(qiang)度?
答:絕(jue)緣(yuan)物質在電場中,當電場強度(du)增大到某一極限時就會被擊(ji)穿,這個導致(zhi)絕(jue)緣(yuan)擊(ji)穿的電場強度(du)稱(cheng)為絕(jue)緣(yuan)強度(du)。
22、對(dui)電纜(lan)導體連接點的機(ji)械強(qiang)度有何要求?
答:連接點的(de)機械強度(du),一(yi)般低于電纜(lan)導體(ti)本(ben)身的(de)抗(kang)拉(la)強度(du),對于固定(ding)敷(fu)設(she)的(de)電力電纜(lan),其(qi)連接點的(de)抗(kang)拉(la)強度(du)要求(qiu)不低于導體(ti)本(ben)身抗(kang)拉(la)強度(du)的(de)60%。
23、電力電纜(lan)的絕(jue)緣層(ceng)材料(liao)應具備哪(na)些主要性(xing)能?
答;應(ying)具備下列主要性(xing)能(neng):(1)高的(de)(de)擊穿強(qiang)度;(2)低(di)的(de)(de)介質(zhi)損耗;(3)相當高的(de)(de)絕緣(yuan)(yuan)電阻;(4)優良的(de)(de)耐(nai)放電性(xing)能(neng);(5)具有一定的(de)(de)柔(rou)軟性(xing)和機械強(qiang)度;(6)絕緣(yuan)(yuan)性(xing)能(neng)長期穩定。
24、機(ji)械敷(fu)設電纜時,牽引強度(du)有何規定?
答:對于(yu)銅芯電(dian)纜(lan)(lan),當牽引(yin)(yin)(yin)頭(tou)部時,允(yun)許(xu)(xu)牽引(yin)(yin)(yin)強(qiang)度(du)為(wei)70N/cm;對于(yu)鋁芯電(dian)纜(lan)(lan),當牽引(yin)(yin)(yin)頭(tou)部時,允(yun)許(xu)(xu)牽引(yin)(yin)(yin)強(qiang)度(du)為(wei)40N/cm;若(ruo)利用(yong)鋼絲網套牽引(yin)(yin)(yin)時,鉛(qian)護套電(dian)纜(lan)(lan)允(yun)許(xu)(xu)強(qiang)度(du)為(wei)10N/cm;鉛(qian)護套電(dian)纜(lan)(lan)為(wei)40N/cm。
25、對電纜保護管有何規定?
答:(1)電纜(lan)需要穿保(bao)護管(guan)(guan)敷設時(shi),管(guan)(guan)子內徑不應小于電纜(lan)外徑的(de)1.5倍,混凝土管(guan)(guan)、陶土管(guan)(guan)、石棉(mian)、水泥(ni)管(guan)(guan)的(de)內徑不應小于100mm;
(2)電纜(lan)管(guan)的彎(wan)曲半徑應符合(he)所穿入電纜(lan)彎(wan)曲半徑的規定(ding);
(3)每根管子最多不應超過三個彎頭(tou),直角(jiao)彎不應多于2個。
26、如何(he)測量(liang)電纜護(hu)套的外徑?
答:在護套圓周上(shang)均(jun)(jun)(jun)勻分布的(de)五點處,測量(liang)護套外(wai)徑和其平均(jun)(jun)(jun)值(zhi),其平均(jun)(jun)(jun)外(wai)徑既為護套的(de)外(wai)徑。
27、不同(tong)截面的(de)銅(tong)芯電(dian)纜如何連接?
答:不同截(jie)面的銅(tong)(tong)(tong)芯電(dian)纜連(lian)接,可(ke)采用開口(kou)弱背銅(tong)(tong)(tong)接管(guan),以錫焊(han)法連(lian)接,也可(ke)用純銅(tong)(tong)(tong)棒(bang)按(an)不同的截(jie)面要求連(lian)接成銅(tong)(tong)(tong)接管(guan),以壓接法連(lian)接。
28、簡述10KV交(jiao)聯電纜熱縮式(shi)制作戶內終端(duan)頭(tou)的(de)過程?
答;(1)準備(bei)階段:檢(jian)(jian)查(cha)(cha)熱縮電纜附件是(shi)否齊備(bei),型號是(shi)否相配,檢(jian)(jian)查(cha)(cha)并(bing)確認電纜有無潮氣后,檢(jian)(jian)查(cha)(cha)電纜。
(2)切(qie)除多余(yu)電(dian)纜,根據現(xian)場情況決定電(dian)纜長度(du)。
(3)剝除護層。
(4)焊(han)接(jie)接(jie)地(di)線,將接(jie)地(di)線焊(han)接(jie)在鋼帶上。
(5)填充(chong)三叉口及繞包密封膠。
(6)安裝三芯分支護套(tao),將(jiang)護套(tao)套(tao)入根部(bu)(bu)(bu),從(cong)中部(bu)(bu)(bu)開始收(shou)縮,先往根部(bu)(bu)(bu),再往指部(bu)(bu)(bu)。
(7)剝(bo)(bo)銅(tong)(tong) 帶(dai)和外半導(dao)電(dian)層,剝(bo)(bo)切三芯分(fen)支套口20mm以上的銅(tong)(tong)帶(dai),嚴禁損傷主絕緣,清除干凈半導(dao)電(dian)層。
(8)安裝應力管,管口端部(bu)分支套對接后熱縮。
(9)安裝(zhuang)接線端子。
(10)安裝絕緣管。
(11)安裝(zhuang)密封(feng)管。
(12)核相后安裝(zhuang)相色管(guan)。
29、戶內、戶外預制式終端安裝步驟(zou)有哪(na)些?
答(da):(1) 將(jiang)電纜按預定位置就(jiu)位、固定、清潔(jie)表面,參照(zhao)說明書剝(bo)除外護(hu)套(tao)(tao),如有(you)特殊(shu)需要,外護(hu)套(tao)(tao)剝(bo)切(qie)長度可調整,分(fen)別由銅帶、外護(hu)套(tao)(tao)鎧裝引出2組地(di)線。
(2) 由外(wai)護套口向上量取(qu)需要尺(chi)寸,切除多(duo)余(yu)電(dian)纜(lan),套入(ru)熱(re)縮(suo)三指套至三叉口根部由中間加熱(re)收縮(suo),由指套上口向上量取(qu)規(gui)定尺(chi)寸(35kv為350~380mm)。去掉多(duo)余(yu)銅帶(保(bao)留20mm),再保(bao)留半導體預定位置,壓接出線端子密封。
30、電(dian)線(xian)電(dian)纜(lan)的應用(yong)主要分為三大(da)類 :
(1)、電力系(xi)統(tong)
電(dian)(dian)(dian)(dian)力(li)系統(tong)采用(yong)的電(dian)(dian)(dian)(dian)線(xian)電(dian)(dian)(dian)(dian)纜(lan)產(chan)品主(zhu)要有架空裸電(dian)(dian)(dian)(dian)線(xian)、匯流排(母(mu)線(xian))、電(dian)(dian)(dian)(dian)力(li)電(dian)(dian)(dian)(dian)纜(lan)(塑料線(xian)纜(lan)、油紙力(li)纜(lan)(基本被塑料電(dian)(dian)(dian)(dian)力(li)電(dian)(dian)(dian)(dian)纜(lan)代(dai)(dai)替)、橡(xiang)套線(xian)纜(lan)、架空絕緣電(dian)(dian)(dian)(dian)纜(lan))、分支電(dian)(dian)(dian)(dian)纜(lan)(取(qu)代(dai)(dai)部分母(mu)線(xian))、電(dian)(dian)(dian)(dian)磁線(xian)以(yi)及電(dian)(dian)(dian)(dian)力(li)設備用(yong)電(dian)(dian)(dian)(dian)氣裝備電(dian)(dian)(dian)(dian)線(xian)電(dian)(dian)(dian)(dian)纜(lan)等。
(2)、信息傳輸系(xi)統
用于信(xin)息傳輸(shu)系統的電(dian)(dian)(dian)(dian)線電(dian)(dian)(dian)(dian)纜(lan)主要有市話電(dian)(dian)(dian)(dian)纜(lan)、電(dian)(dian)(dian)(dian)視電(dian)(dian)(dian)(dian)纜(lan)、電(dian)(dian)(dian)(dian)子線纜(lan)、射(she)頻電(dian)(dian)(dian)(dian)纜(lan)、光纖纜(lan)、數據電(dian)(dian)(dian)(dian)纜(lan)、電(dian)(dian)(dian)(dian)磁線、電(dian)(dian)(dian)(dian)力通(tong)訊或其(qi)他復(fu)合電(dian)(dian)(dian)(dian)纜(lan)等。
(3)、機(ji)械設備、儀(yi)器儀(yi)表系統
此部(bu)分(fen)除架空裸(luo)電(dian)(dian)線外(wai)幾乎(hu)其他(ta)所有產品(pin)均有應(ying)用(yong),但主要是電(dian)(dian)力電(dian)(dian)纜(lan)、電(dian)(dian)磁線、數據(ju)電(dian)(dian)纜(lan)、儀器儀表線纜(lan)等。
31、電線電纜產(chan)品主(zhu)要分為五大類:
(1)、裸電線(xian)(xian)及裸導體(ti)(ti)制(zhi)(zhi)品(pin) 本類(lei)產品(pin)的主要特征是(shi):純的導體(ti)(ti)金屬(shu),無絕緣及護套層(ceng),如鋼芯鋁(lv)(lv)絞(jiao)線(xian)(xian)、銅(tong)鋁(lv)(lv)匯流排、電力機車線(xian)(xian)等;加工(gong)工(gong)藝主要是(shi)壓力加工(gong),如熔煉、壓延(yan)、拉制(zhi)(zhi)、絞(jiao)合(he)/緊壓絞(jiao)合(he)等;產品(pin)主要用(yong)在(zai)城郊、農村、用(yong)戶主線(xian)(xian)、開(kai)關柜等。
(2)、電(dian)(dian)力電(dian)(dian)纜本類產品(pin)主要特征是:在導體外擠(ji)(繞)包(bao)絕緣層(ceng),如架空絕緣電(dian)(dian)纜,或幾芯(xin)絞合(he)(對應電(dian)(dian)力系統的相線(xian)(xian)、零線(xian)(xian)和(he)地線(xian)(xian)),如二芯(xin)以(yi)上架空絕緣電(dian)(dian)纜,或再增加護套(tao)層(ceng),如塑料/橡套(tao)電(dian)(dian)線(xian)(xian)電(dian)(dian)纜。主要的工藝技術(shu)有(you)拉制、絞合(he)、絕緣擠(ji)出(chu)(繞包(bao))、成(cheng)纜、鎧(kai)裝、護層(ceng)擠(ji)出(chu)等,各(ge)種產品(pin)的不同工序組合(he)有(you)一定區別。
產(chan)品主要用在發、配、輸(shu)、變、供電(dian)(dian)線路中的(de)強電(dian)(dian)電(dian)(dian)能傳(chuan)輸(shu),通過的(de)電(dian)(dian)流大(幾(ji)十安(an)至幾(ji)千安(an))、電(dian)(dian)壓高(220V至500kV及以上)。
(3)、電(dian)(dian)氣裝備(bei)用電(dian)(dian)線(xian)(xian)電(dian)(dian)纜該類(lei)產(chan)品主(zhu)要(yao)特(te)征是:品種規(gui)格(ge)繁多,應用范(fan)圍(wei)廣(guang)泛,使(shi)用電(dian)(dian)壓在1kV及以下較多,面對(dui)特(te)殊場合(he)不斷衍(yan)生新的(de)產(chan)品,如(ru)耐火線(xian)(xian)纜、阻燃線(xian)(xian)纜、低(di)煙(yan)無鹵/低(di)煙(yan)低(di)鹵線(xian)(xian)纜、防白蟻、防老鼠線(xian)(xian)纜、耐油/耐寒/耐溫/耐磨線(xian)(xian)纜、醫(yi)用/農用/礦用線(xian)(xian)纜、薄壁電(dian)(dian)線(xian)(xian)等。
(4)、通訊(xun)電(dian)纜(lan)及光纖(簡(jian)略介紹)隨著(zhu)近二十(shi)多年來,通訊(xun)行業的(de)飛速發展(zhan),產品也(ye)有驚人的(de)發展(zhan)速度(du)。從過去(qu)的(de)簡(jian)單的(de)電(dian)話(hua)(hua)電(dian)報線纜(lan)發展(zhan)到幾千(qian)對的(de)話(hua)(hua)纜(lan)、同軸纜(lan)、光纜(lan)、數(shu)據電(dian)纜(lan),甚(shen)至組(zu)合(he)通訊(xun)纜(lan)等(deng)。
該類產(chan)品結構尺(chi)寸通常較小而(er)均勻,制造精(jing)度要(yao)求(qiu)高。
(5)、電(dian)磁線(繞組(zu)線)主要用于(yu)各種電(dian)機、儀(yi)器儀(yi)表等。
電線電纜的衍生/新產品
電(dian)線電(dian)纜的(de)衍生/新(xin)產品(pin)主(zhu)要(yao)是(shi)因(yin)應(ying)(ying)用(yong)(yong)場合、應(ying)(ying)用(yong)(yong)要(yao)求(qiu)(qiu)(qiu)不同(tong)(tong)及(ji)裝備的(de)方便性和降低裝備成本等的(de)要(yao)求(qiu)(qiu)(qiu),而(er)采用(yong)(yong)新(xin)材料、特殊(shu)材料、或改變產品(pin)結構、或提(ti)高工(gong)藝要(yao)求(qiu)(qiu)(qiu)、或將不同(tong)(tong)品(pin)種(zhong)的(de)產品(pin)進(jin)行組(zu)合而(er)產生。
采(cai)用不同材料如阻燃線(xian)(xian)纜(lan)、低(di)煙無鹵/低(di)煙低(di)鹵線(xian)(xian)纜(lan)、防白蟻、防老鼠線(xian)(xian)纜(lan)、耐油/耐寒/耐溫線(xian)(xian)纜(lan)等;
改變產品結構(gou)如:耐火電纜等;
提高工(gong)藝要求如:醫用線纜等;
組合(he)產(chan)品如(ru):OPGW等;
方(fang)便(bian)安裝和降低裝備成本如:預制分支電纜(lan)等。
32、母線裝置施工完,應進行(xing)哪些檢查?
答:應進(jin)行下列檢查:
(1)金屬構件的加工、配制、焊接螺(luo)接應符合規定;
(2)各部螺(luo)栓、墊圈、開口銷(xiao)等零部件應齊(qi)全可(ke)靠;
(3)母線(xian)配制及安裝架應符合規(gui)定,相間(jian)及對地(di)電氣距(ju)離(li)符合要求(qiu);
(4)瓷件(jian)(jian)、鐵件(jian)(jian)及膠合處應完整(zheng),充(chong)油套(tao)管應無(wu)滲油,油位正常;
(5)油漆完整,相色正(zheng)確,接(jie)地良好。
33、在35kv及(ji)以下電力電纜接(jie)頭中,改(gai)善(shan)其(qi)(qi)護套斷(duan)開(kai)處電場分(fen)布的(de)方(fang)法有幾種(請(qing)列出五(wu)種),并簡述其(qi)(qi)方(fang)法。
答:(1)脹喇叭口:在鉛包(bao)(bao)割斷處(chu)把鉛包(bao)(bao)邊(bian)緣(yuan)撬起,成喇叭狀,其(qi)邊(bian)緣(yuan)應光滑(hua)、圓整、對稱。
(2)預(yu)留統包(bao)絕緣:在鉛(qian)包(bao)切口至電纜芯線分開點之間留有一段統包(bao)絕緣紙。
(3)切除(chu)半導電紙(zhi):將半導電紙(zhi)切除(chu)到喇叭口以(yi)下。
(4)包(bao)繞應力錐:用(yong)絕(jue)緣(yuan)包(bao)帶(dai)和導電(dian)金(jin)屬(shu)材料包(bao)成錐形,人為地將(jiang)屏蔽層擴(kuo)大,以改善電(dian)場分布(bu)。
(5)等(deng)電位法:對(dui)于干(gan)包型或交聯聚乙烯電纜頭,在各線芯概況絕緣(yuan)表面上(shang)包一段金屬(shu)帶,并將其連接(jie)在一起。
(6)裝設應(ying)力控制管:對于35kv及發下熱(re)縮管電纜頭(tou),首先從線芯銅屏(ping)蔽(bi)層末端方向經半導體帶至線芯絕緣(yuan)概況包繞2層半導體帶,然后將相應(ying)規格折應(ying)力管,套在銅屏(ping)蔽(bi)的(de)末端處,熱(re)縮成形。
34、電纜(lan)支架的加工應符合哪些要求?
答:(1)鋼(gang)材應(ying)平直,無(wu)(wu)明顯扭曲,下料誤差應(ying)在5mm范圍(wei)內,切口(kou)應(ying)無(wu)(wu)卷邊,毛剌;
(2)支架應焊接牢(lao)固,無顯蓍變形,各橫撐間的垂直凈(jing)距與設計偏差不應大于5mm;
(3)金屬(shu)支(zhi)架必須進(jin)行防(fang)腐處(chu)理,位于濕熱、鹽、霧以及有(you)化學腐蝕(shi)地區時,應(ying)根據設計作特殊的防(fang)腐處(chu)理。
35、列(lie)舉(ju)出你熟悉的電(dian)纜架(jia)。
答:拼(pin)焊(han)式E型架(jia)、裝配式E型架(jia)、橋式電纜架(jia)、電纜托架(jia)、掛鉤式支(zhi)架(jia)、單根電纜支(zhi)架(jia)等。
36、敷設電纜應(ying)滿足哪些要求?
答:應滿足以下要求:
(1)安全運行方面,盡可(ke)能避(bi)免各(ge)種外來損壞(huai),提(ti)高電纜線路的供電可(ke)靠性;
(2)經(jing)濟方(fang)面,從投資最省的方(fang)面考慮;
(3)施工方(fang)面,電纜線(xian)路的路徑必須便于旋工和投運后的維(wei)修。
37、制作電纜終端頭或中間(jian)接頭的絕(jue)緣材(cai)料有哪(na)些?
答:有絕(jue)緣(yuan)(yuan)(yuan)膠、絕(jue)緣(yuan)(yuan)(yuan)帶、絕(jue)緣(yuan)(yuan)(yuan)管、絕(jue)緣(yuan)(yuan)(yuan)手(shou)套(tao)、絕(jue)緣(yuan)(yuan)(yuan)樹脂等。
38、簡述電纜頭制作(zuo)(zuo)的一(yi)般操作(zuo)(zuo)程(cheng)序。答:(1)制作(zuo)(zuo)前(qian)的準備(bei):包括○1閱讀安(an)裝說明書;○2察看現場;○3備(bei)料;○4電纜試(shi)潮;○5制作(zuo)(zuo)前(qian)測試(shi)等。
(2)接頭的制作過程:包括○1割斷多(duo)余電纜(lan);○2電纜(lan)保護層的剝(bo)切(qie);○3導體(ti)連接;○4包繞絕緣(yuan)(或收縮管(guan)材);○5安(an)裝接頭外殼;○6灌注絕緣(yuan)劑;○7進行密封處理等(deng)。
(3)制作(zuo)后電氣(qi)測(ce)試。
39、電纜保護管的加工應符合哪(na)些(xie)要(yao)求?
答:(1)管(guan)口應(ying)*剌(la)和尖銳楞角,管(guan)口宜做成喇叭形。
(2)電(dian)纜(lan)(lan)管在彎制后,不(bu)應有(you)裂縫和顯著的凹癟現象,其彎扁程度不(bu)宜(yi)大于(yu)管子(zi)外(wai)徑(jing)10%;電(dian)纜(lan)(lan)管的彎曲半徑(jing)不(bu)應小(xiao)于(yu)所穿入電(dian)纜(lan)(lan)的最小(xiao)允許彎曲半徑(jing)。
(3)金屬管應在外表(biao)涂(tu)防腐(fu)漆或瀝表(biao),鍍(du)鋅(xin)管鋅(xin)層(ceng)剝落處也應涂(tu)以防腐(fu)漆。
40、電纜(lan)(lan)的(de)排列符合哪些(xie)要求?答:(1)電力電纜(lan)(lan)和控纜(lan)(lan)不(bu)應配置在同(tong)一層支架(jia)上。
(2)高、低壓電(dian)(dian)纜(lan),強、弱電(dian)(dian)控纜(lan)應(ying)按須序分層(ceng)配置,一般情況宜由上而下(xia),但在含有35kv以上高壓電(dian)(dian)纜(lan)引入柜盤時,為滿足彎曲半徑(jing),可由下(xia)面上配置。
41、電纜(lan)溝內敷設電纜(lan)的(de)方法(fa)是什么(me)?
答:在(zai)電纜(lan)溝(gou)內(nei)敷設電纜(lan)的(de)方法與直(zhi)埋電纜(lan)的(de)敷設方法相仿,一般(ban)可將滑輪放(fang)在(zai)溝(gou)內(nei),施放(fang)完畢,將電纜(lan)放(fang)于溝(gou)底(di)或支(zhi)架(jia)上(shang),并在(zai)電纜(lan)上(shang)綁扎電纜(lan)標牌(pai)。
42、電(dian)纜敷(fu)設的(de)常(chang)用設備有哪(na)些?
答:(1)空氣(qi)壓縮機,主(zhu)要(yao)用來破壞(huai)路面,為以后敷設(she)電纜作準備;
(2)電動(dong)卷(juan)揚機(ji)或電纜(lan)牽引機(ji),主要用來拖(tuo)電纜(lan);
(3)電纜輸送機(ji),配合牽(qian)引機(ji)使用來克服巨大的摩(mo)擦力(li),減輕對(dui)電纜的損壞;
(4)電纜盤放線支架;
(5)滾輪(lun)裝(zhuang)置;
(6)防捻 ,減(jian)鋼絲繩出現的(de)扭曲(qu);
(7)電纜(lan)盤制動(dong)裝置;
(8)張力計(ji)。
43、電(dian)纜(lan)(lan)(lan)(lan)溝(gou)中支架安裝(zhuang)距離的要求如何?答:電(dian)纜(lan)(lan)(lan)(lan)固(gu)定于(yu)電(dian)纜(lan)(lan)(lan)(lan)溝(gou)和(he)隧道的墻上,水平裝(zhuang)置時,當(dang)電(dian)纜(lan)(lan)(lan)(lan)外(wai)徑等(deng)于(yu)或(huo)小于(yu)50mm時應每(mei)(mei)隔1m加一支撐(cheng);外(wai)徑大于(yu)50mm的電(dian)纜(lan)(lan)(lan)(lan)每(mei)(mei)隔0.6m加一支撐(cheng);排成三角(jiao)形(xing)的單電(dian)纜(lan)(lan)(lan)(lan),每(mei)(mei)隔1m應用綁(bang)帶扎牢(lao),垂(chui)直裝(zhuang)置時,每(mei)(mei)隔1~1.5m加以固(gu)定。
44、如何處理電(dian)(dian)力(li)電(dian)(dian)纜與控制電(dian)(dian)纜在同一托架的安(an)裝?
答:電(dian)力(li)電(dian)纜與控制電(dian)纜一(yi)般不應敷(fu)設(she)在同一(yi)托架內(nei),當電(dian)纜較少而將控纜與電(dian)力(li)電(dian)纜敷(fu)設(she)在同一(yi)托架內(nei)時,應用隔板隔開(kai)。
45、電纜(lan)隧道內(nei)如何(he)裝設(she)接地線?
答(da):隧道(dao)和(he)(he)(he)溝的全(quan)長應(ying)裝設連(lian)續(xu)的接(jie)地(di)線(xian),接(jie)地(di)線(xian)應(ying)和(he)(he)(he)所有的支(zhi)架相連(lian),兩頭和(he)(he)(he)接(jie)地(di)極連(lian)通。接(jie)地(di)線(xian)的規(gui)格應(ying)符(fu)合(he)設計要(yao)求(qiu)。電纜鉛包和(he)(he)(he)鎧裝除了有絕緣要(yao)求(qiu)外(wai),應(ying)全(quan)部相互連(lian)接(jie)并和(he)(he)(he)接(jie)地(di)線(xian)相連(lian),電纜架和(he)(he)(he)接(jie)地(di)線(xian)均應(ying)涂防銹漆或(huo)鍍鋅。
46、對于電纜孔洞的防火封堵有何(he)要求?
答:對于(yu)較大的(de)電纜(lan)貫穿孔洞,如(ru)電纜(lan)貫穿樓板處等,采(cai)用防(fang)火(huo)堵(du)(du)(du)料(liao)(liao)封堵(du)(du)(du)時(shi),應根據實際情況,先在電纜(lan)表面涂(tu)四(si)至(zhi)六層防(fang)火(huo)涂(tu)料(liao)(liao),長度自孔洞以(yi)下1.5m左右,再用耐(nai)火(huo)材料(liao)(liao)加工成具(ju)有一定強(qiang)度的(de)板托防(fang)火(huo)堵(du)(du)(du)料(liao)(liao),保證封堵(du)(du)(du)后牢固并便于(yu)更換電纜(lan)時(shi)拆(chai)裝(zhuang),封堵(du)(du)(du)密實無孔隙以(yi)有效(xiao)地堵(du)(du)(du)煙(yan)堵(du)(du)(du)火(huo)。
47、噴燈(deng)點火前應注意哪些檢查(cha)?
答:應進行下(xia)列(lie)各項檢查:
(1)打氣筒是否漏(lou)油(you)(you)或滲(shen)油(you)(you),油(you)(you)桶及噴(pen)嘴處是否漏(lou)油(you)(you)、漏(lou)氣;
(2)油桶(tong)內的(de)(de)油量(liang)(liang)是(shi)否超過油桶(tong)容量(liang)(liang)的(de)(de)3/4,加油的(de)(de)螺絲塞(sai)是(shi)否擰(ning)緊。
48、使(shi)用噴(pen)燈應注意哪些(xie)事(shi)項(xiang)?
答(da):(1)噴燈更大 注油量為油筒容積的(de)3/4;
(2)開(kai)始打氣壓力(li)不(bu)要太(tai)大,點(dian)燃后火焰由黃變藍(lan)即可使用;
(3)周圍(wei)不得有易(yi)燃物,空氣要流通(tong);
(4)停用時先(xian)關(guan)閉調節(jie)開關(guan),火熄后,慢慢旋松油(you)孔(kong)蓋放氣,空氣放完后,要(yao)(yao)要(yao)(yao)旋松調節(jie)開關(guan),完全(quan)冷卻后再旋松孔(kong)蓋;
(5)煤油(you)噴燈(deng)與(yu)汽油(you)噴燈(deng)要分開使用。
49、手(shou)動油壓鉗有何(he)用(yong)途?如何(he)操作?
答:兩根導線(xian)的(de)連(lian)接(jie)(jie)通常是將兩導線(xian)端穿入相(xiang)同材料制(zhi)成的(de)壓(ya)(ya)(ya)管中,用壓(ya)(ya)(ya)接(jie)(jie)鉗擠(ji)壓(ya)(ya)(ya)數個(ge)坑,使導線(xian)連(lian)接(jie)(jie)在一(yi)起(qi),壓(ya)(ya)(ya)接(jie)(jie)時,手柄向上抬起(qi)時,柱塞(sai)向外移(yi)(yi)動(dong),進油(you)(you)(you)(you)閥下腔產生真(zhen)空,油(you)(you)(you)(you)箱(xiang)內(nei)的(de)油(you)(you)(you)(you)進入柱塞(sai)腔。手柄下壓(ya)(ya)(ya)時,柱塞(sai)向內(nei)移(yi)(yi)動(dong),油(you)(you)(you)(you)受壓(ya)(ya)(ya)后,使進油(you)(you)(you)(you)閥關(guan)閉,打(da)開(kai)出(chu)油(you)(you)(you)(you)閥,使油(you)(you)(you)(you)壓(ya)(ya)(ya)進入液壓(ya)(ya)(ya)缸(gang),推動(dong)活塞(sai)和陽(yang)模(mo)(mo),陽(yang)、陰(yin)模(mo)(mo)之(zhi)間放(fang)有壓(ya)(ya)(ya)接(jie)(jie)管,當壓(ya)(ya)(ya)接(jie)(jie)被擠(ji)壓(ya)(ya)(ya)的(de)坑深到一(yi)定值時,開(kai)啟回(hui)油(you)(you)(you)(you)閥,活塞(sai)自(zi)動(dong)返回(hui),壓(ya)(ya)(ya)完一(yi)個(ge)坑后,移(yi)(yi)動(dong)壓(ya)(ya)(ya)鉗,再(zai)壓(ya)(ya)(ya)下一(yi)個(ge)。
50、常用低壓(ya)電(dian)力電(dian)纜按絕緣和保護(hu)層(ceng)的不同(tong),主要可分為哪幾(ji)類(lei)?
答:(1)油浸紙絕緣鉛(qian)包(或鋁(lv)包)電(dian)力電(dian)纜;
(2)不滴流油浸紙絕緣電力電纜;
(3)聚(ju)(ju)氯乙烯絕緣聚(ju)(ju)氯乙烯護套電(dian)力電(dian)纜;
(4)交(jiao)聯聚氯(lv)乙烯絕(jue)緣聚乙烯護套電力電纜;
(5)交(jiao)聯聚(ju)氯乙烯絕緣聚(ju)氯乙烯護套電(dian)力電(dian)纜;
(6)橡皮絕緣電力電纜(lan)。
51、常用絕緣材料的類(lei)別哪些?舉(ju)例說明?
答:(1)無(wu)機絕(jue)緣材(cai)料:有云母、石棉(mian)、大理石、瓷器(qi)、玻(bo)璃等;
(2)有(you)機絕緣材料:有(you)樹(shu)脂、橡膠(jiao)、紙、麻(ma)、棉(mian)紗等(deng);
(3)混合絕(jue)緣材料:用以上絕(jue)緣材料加工而(er)成型的名種(zhong)絕(jue)緣材料。
52、在哪種情況下采用排(pai)管敷設?有什(shen)么優點(dian)?
答:排管敷設一般(ban)用在與其他建(jian)筑(zhu)物、公路或(huo)鐵路相(xiang)交叉的地(di)方(fang),有時也(ye)在建(jian)筑(zhu)物密集(ji)區內采用。主要優點是占地(di)少,能承受大的荷重,電纜相(xiang)互間互不影響(xiang),比較安全。
53、何(he)謂電纜長期允許載流(liu)量?
答:電(dian)(dian)纜(lan)(lan)長期允許(xu)載(zai)流(liu)量是指(zhi)在(zai)電(dian)(dian)纜(lan)(lan)內通過規定電(dian)(dian)流(liu)時,在(zai)熱(re)穩定后,電(dian)(dian)纜(lan)(lan)導體(ti)達到長期允許(xu)工作溫(wen)度時的電(dian)(dian)流(liu)數值。
54、決定電(dian)纜長期允許載流量的因素有哪些(xie)?
答:有以下三個因素決(jue)定:
(1)電纜的長期容許工作溫度;
(2)電纜本身的散熱性能;
(3)電纜(lan)裝置情(qing)況及周(zhou)圍環境的散熱條件。
55、電纜的(de)敷設方式(shi)有幾種(zhong)?
答:有以下幾種:
(1)直埋在(zai)地下;
(2)安裝在電纜溝(gou)內;
(3)安裝(zhuang)在(zai)地下隧道內;
(4)安裝在建(jian)筑物內(nei)部墻上或天棚上;
(5)安裝(zhuang)在橋架上(shang);
(6)敷設在(zai)排(pai)管內;
(7)敷設在水底。
56、如(ru)何進行電纜(lan)管的連接(jie)工作?
答:電纜管(guan)(guan)連(lian)(lian)接(jie)(jie)時(shi)(shi),必須用(yong)(yong)扣(kou)和(he)管(guan)(guan)接(jie)(jie)頭連(lian)(lian)接(jie)(jie),如采用(yong)(yong)焊(han)接(jie)(jie)時(shi)(shi),不能(neng)直接(jie)(jie)對焊(han),連(lian)(lian)接(jie)(jie)處要套上(shang)一段粗(cu)管(guan)(guan)再進行焊(han)接(jie)(jie),以免焊(han)渣掉入管(guan)(guan)內。
57、制(zhi)作電(dian)(dian)纜(lan)頭時,對上(shang)下(xia)扳彎電(dian)(dian)纜(lan)芯線有何(he)要求(qiu)?
答:扳彎線(xian)(xian)芯時,不得(de)損傷(shang)紙絕(jue)緣(yuan),芯線(xian)(xian)的彎曲半徑不得(de)小于(yu)電纜線(xian)(xian)芯的10倍(bei)。制作時要特別小心,應使線(xian)(xian)芯彎曲部分均(jun)勻受力,否則(ze)極(ji)易損傷(shang)絕(jue)緣(yuan)紙。
58、簡述(shu)塑料電纜(lan)的(de)熱收縮密封(feng)法。
答(da):熱(re)縮法適用于中、低(di)壓橡、塑(su)電(dian)纜接頭和(he)終端(duan)頭的密封,也可適用于不(bu)滴流(liu)和(he)黏(nian)性浸漬絕(jue)緣電(dian)纜。采用交聯聚乙烯型和(he)硅橡膠型兩大類(lei)遇熱(re)后能均(jun)勻收縮的熱(re)收縮管(guan)(guan)。將這種(zhong)管(guan)(guan)材套于預定的粘合密封部位,并在(zai)粘和(he)部位涂上熱(re)熔膠,當加熱(re)到(dao)一定溫度(du)后,熱(re)縮管(guan)(guan)將收縮,同(tong)時熱(re)熔膠熔化,待自然冷卻后即形成(cheng)一道良好(hao)的密封封層。
59、用電(dian)動彎管(guan)機彎制電(dian)纜保護管(guan)時(shi)應注意什么?
答:(1)彎管機應由了解其性能并熟悉操(cao)作知(zhi)識(shi)的人員操(cao)作;
(2)使用前必(bi)須(xu)進行檢(jian)查(cha),按鈕、操(cao)作把手、行程開(kai)關應完好,彎(wan)管機必(bi)須(xu)可靠接(jie)地;
(3)選用符合要求的模具,確定好所需要的彎曲(qu)半徑;
(4)施(shi)工場地周(zhou)圍,應(ying)有充足的活(huo)動范(fan)圍;
(5)使(shi)用時待(dai)空轉正常后,方可帶負荷工作,運行中,嚴禁用手腳接觸其轉動部分;
(6)工(gong)作完畢應(ying)及(ji)時停電(dian),釋(shi)放油(you)壓。
60、電纜清冊(ce)的內容及電纜編(bian)號的含義是(shi)什么?
答(da):電(dian)纜(lan)(lan)清(qing)冊是施放電(dian)纜(lan)(lan)和指(zhi)導(dao)施工的(de)(de)依據,運行維護的(de)(de)檔(dang)案資料(liao)。應列(lie)入每根電(dian)纜(lan)(lan)的(de)(de)編號、起(qi)始點、型號、規(gui)格、長度,并分類統(tong)計(ji)出(chu)總長度,控纜(lan)(lan)還應列(lie)出(chu)每根電(dian)纜(lan)(lan)的(de)(de)備用芯(xin)。
電纜編(bian)號(hao)是識別電纜的(de)標志,故要(yao)求(qiu)全廠編(bian)號(hao)不重(zhong)復,并且(qie)有一(yi)定的(de)含(han)義和規律,能表達(da)電纜的(de)特征。
61、電纜目前采(cai)用的敷設(she)方(fang)法可分為幾類?
答:(1)人工敷設(she),即采用人海戰術,在一人或多人協(xie)調指(zhi)揮下,按(an)規定進行敷設(she);
(2)機(ji)械(xie)化(hua)敷(fu)設(she),即采用滾輪、牽(qian)引器(qi)、輸(shu)送(song)機(ji),通過一同(tong)步(bu)電源進行控制,比較安(an)全;
(3)人工(gong)和機械相結合,有些現(xian)場由于轉彎較多,施(shi)工(gong)難(nan)度大(da),全用機械較困(kun)難(nan),所以采(cai)用此法。
62、控制二(er)次回路(lu)接線應符合哪些要求?
答:(1)按圖施工接線(xian)正(zheng)確;
(2)導線(xian)的電氣連接應牢固(gu)可靠;
(3)盤柜內的導線不應有(you)接頭,導線芯線應無損傷;
(4)電(dian)纜(lan)芯線(xian)端(duan)部應標明其回路編(bian)號(hao),編(bian)號(hao)應正確,字跡(ji)清晰且不易脫色;
(5)配線應(ying)整齊、清晰(xi)、美觀,導線絕緣應(ying)良好(hao)、無(wu)損(sun);
(6)每(mei)個(ge)接線(xian)端子(zi)的每(mei)側接線(xian)宜(yi)為一根,最多不得超過兩根。
63、電纜排管(guan)有何(he)要求?
答(da):(1)排管頂部至地面距離,在(zai)廠(chang)房內(nei)為0.2m,人行(xing)道下為0.5m,一(yi)般(ban)地區(qu)為0.7m;
(2)在變更(geng)方向(xiang)及分支處均應裝置排(pai)管井坑,長度(du)超過30mm時(shi)也應加設井坑;
(3)井坑(keng)深度不(bu)小(xiao)于(yu)0.8m,人孔直徑不(bu)小(xiao)于(yu)0.7mm;
(4)排管應有(you)傾(qing)向井(jing)坑0.5%~1%的排水坡度。
64、對于電纜導體連(lian)接點的電阻有何要求?
答:要求連接點(dian)的(de)電阻小(xiao)而且穩定,連接點(dian)的(de)電阻與相(xiang)同長度、相(xiang)同截面的(de)導(dao)體之比值,對于新安裝(zhuang)的(de)終端頭和中間頭,應不(bu)大于1;對于運(yun)行中的(de)終端頭和中間頭這個比值不(bu)應大于1.2。
65、電纜接頭(tou)和中間頭(tou)的(de)設計應(ying)滿足哪些要(yao)求?
答:應滿足的要(yao)求有:
(1)耐壓強(qiang)度高,導體連接好;
(2)機械強(qiang)度大(da),介(jie)質損(sun)失小(xiao);
(3)結構簡單(dan),密封(feng)性(xing)強。
66、什么是(shi)電纜故障?有幾種常見(jian)的(de)類型?
答:電(dian)(dian)(dian)纜故(gu)(gu)障(zhang)是指電(dian)(dian)(dian)纜在預防(fang)性(xing)試驗時(shi)發生(sheng)絕緣擊穿或在運行中,因絕緣擊穿、導線(xian)(xian)燒斷(duan)等(deng)而(er)迫使電(dian)(dian)(dian)纜線(xian)(xian)路停電(dian)(dian)(dian)的故(gu)(gu)障(zhang)。常見(jian)的故(gu)(gu)障(zhang)有接地故(gu)(gu)障(zhang)、短路故(gu)(gu)障(zhang)、斷(duan)線(xian)(xian)故(gu)(gu)障(zhang)、閃絡性(xing)故(gu)(gu)障(zhang)和(he)混(hun)合型故(gu)(gu)障(zhang)等(deng)。
67、如何處(chu)理電(dian)纜線路的單相(xiang)接地(di)故障?
答:電(dian)纜(lan)線路單相(xiang)接地(di)故(gu)障(zhang)一般來(lai)說,電(dian)纜(lan)導體的損傷(shang)只(zhi)是局(ju)部的,如果屬于機械(xie)損傷(shang),而(er)故(gu)障(zhang)點附(fu)近的土(tu)壤又較(jiao)干燥時,一般可(ke)(ke)進(jin)行局(ju)部修理(li),加(jia)添一只(zhi)假接頭,即不將電(dian)纜(lan)芯鋸斷,僅將故(gu)障(zhang)點絕緣(yuan)加(jia)強(qiang)后密封即可(ke)(ke)。
68、電(dian)力電(dian)纜在敷設前應進行哪些試驗和檢查?
答(da):敷設前應檢查電(dian)纜的型(xing)號、規格及長度(du)是否(fou)(fou)符(fu)合要求,是否(fou)(fou)有外力損傷,低壓電(dian)纜用1000V兆歐表遙測(ce)絕緣電(dian)阻(zu),阻(zu)值(zhi)一般不低于(yu)10MΩ,高壓電(dian)纜用2500V兆歐表搖(yao)測(ce)阻(zu)值(zhi)一般不抵(di)于(yu)400MΩ。
69、主(zhu)廠房內敷設電纜時一般應注(zhu)意什么?
答:在主廠房內敷設電(dian)纜時一般(ban)應(ying)注意:
(1)凡引至集控室的控制電纜(lan)宜架空敷設;
(2)6KV電纜宜(yi)用隧道或排管敷設,地下水位高處亦可架空或用排管敷設;
(3)380V電纜當兩端(duan)電纜在(zai)零米時(shi)宜用隧道、溝或排管,當一端(duan)設備在(zai)上、一端(duan)在(zai)下時(shi),可部分架空敷設,當地(di)下水位較高時(shi),宜架空。
70、電力(li)電纜的內屏蔽(bi)層與外屏蔽(bi)層各(ge)在什么部位(wei)?采用什么材料(liao)?有何作用?
答:為了(le)使絕(jue)(jue)緣層(ceng)(ceng)和(he)電(dian)纜導(dao)體(ti)有較(jiao)好的接(jie)觸,消(xiao)除導(dao)體(ti)表面(mian)的不(bu)光(guang)滑引起的導(dao)體(ti)表面(mian)電(dian)場強(qiang)度的增加,一(yi)般在導(dao)體(ti)表面(mian)包有金屬化(hua)紙或半(ban)導(dao)體(ti)紙帶(dai)的內屏(ping)蔽(bi)層(ceng)(ceng)。為了(le)使絕(jue)(jue)緣層(ceng)(ceng)和(he)金屬護(hu)套有較(jiao)好的接(jie)觸,一(yi)般在絕(jue)(jue)緣層(ceng)(ceng)外(wai)表面(mian)包有外(wai)層(ceng)(ceng)屏(ping)蔽(bi)層(ceng)(ceng)。外(wai)屏(ping)層(ceng)(ceng)與(yu)內屏(ping)層(ceng)(ceng)的材料(liao)相同(tong),有時還外(wai)扎銅(tong)帶(dai)或編織(zhi)銅(tong)絲(si)帶(dai)。
71、簡述環氧樹(shu)脂復合物的構(gou)成及性能。
答:環氧樹脂復合(he)物由環氧樹脂加入硬化(hua)劑(ji)、填充劑(ji)增韌劑(ji)和稀釋劑(ji)組(zu)成。具有(you)以下性(xing)能:
(1)有(you)足(zu)夠的機械強度;
(2)電氣性能優良;
(3)電氣性能穩定;
(4)與有色金屬有足夠(gou)的黏附力;
(5)耐腐蝕性好;
(6)戶外使用時(shi),耐(nai)雨、耐(nai)光、耐(nai)濕熱。
72、單芯(xin)電纜護套一端接地方式(shi)中為什么必(bi)須安裝一條沿電纜平(ping)行敷設(she)的回流線(xian)?
答:在金屬護(hu)套一端接地(di)的(de)(de)電(dian)纜(lan)線(xian)路中,為(wei)(wei)確保(bao)護(hu)套中的(de)(de)感應電(dian)壓不超過允(yun)許標準,必須安裝一條沿電(dian)纜(lan)線(xian)路平行敷設(she)的(de)(de)導體,且導體的(de)(de)兩端接地(di),這種導體稱(cheng)為(wei)(wei)回(hui)流(liu)(liu)(liu)線(xian)。當(dang)發(fa)生單相接地(di)故障時,接地(di)短路電(dian)流(liu)(liu)(liu)可以通(tong)過回(hui)流(liu)(liu)(liu)線(xian)流(liu)(liu)(liu)回(hui)系統中心點,由于通(tong)過回(hui)流(liu)(liu)(liu)線(xian)的(de)(de)接地(di)電(dian)流(liu)(liu)(liu)產生的(de)(de)磁通(tong)抵消了一部分電(dian)纜(lan)導線(xian)接地(di)電(dian)流(liu)(liu)(liu)所(suo)產生的(de)(de)磁通(tong),因而(er)可降低(di)短路故障時護(hu)套的(de)(de)感應電(dian)壓。
73、電纜工(gong)程可劃分(fen)為幾個(ge)項目?
答:(1)工(gong)地(di)運(yun)輸(shu):包括工(gong)程材料從(cong)倉庫到施工(gong)點(dian)的裝卸、運(yun)輸(shu)和空車回程。
(2)地方(fang)工程:包(bao)括路面開挖、隧、溝(gou)道施(shi)工等。
(3)敷(fu)設工程:包括(kuo)敷(fu)設、中間頭制作、掀蓋板(ban)、埋管、校(xiao)潮、牽引頭制作等。
(4)兩端(duan)工程:包括支、吊橋(qiao)架和(he)其基(ji)礎(chu)的制作(zuo)安(an)裝,終(zhong)端(duan)頭(tou)制作(zuo),油壓(ya)力和(he)信號裝置的安(an)裝,名種電氣性能(neng)測(ce)試等。
(5)塞止(zhi)工(gong)程:包(bao)括充油(you)電纜(lan)塞止(zhi)頭制作,供油(you)箱(xiang)、自動(dong)排水(shui)及信號裝置的安(an)裝等。
(6)接(jie)(jie)地工(gong)程:包括絕緣接(jie)(jie)頭(tou)、換位箱、保護(hu)器(qi)、接(jie)(jie)地箱安裝等。
74、電纜(lan)線(xian)路的驗收(shou)應進行哪些檢查?
答(da):(1)電纜規格應符合(he)規定,排列應整(zheng)齊(qi),無損傷,標牌齊(qi)全、正確、清晰(xi);
(2)電(dian)纜的(de)固定彎曲半徑、有關距(ju)離及單(dan)芯電(dian)力電(dian)纜的(de)金屬護(hu)層(ceng)的(de)接線應符合要求;
(3)電(dian)纜終(zhong)端、中間頭不滲漏油,安裝牢固(gu),充油電(dian)纜油壓及表計整(zheng)定(ding)值(zhi)應(ying)符合(he)要求;
(4)接地良好;
(5)電纜終端相色正確,支架等(deng)的金屬部(bu)件油漆完整;
(6)電纜溝及隧道(dao)內、橋架上應(ying)無雜物,蓋板齊(qi)全。
75、電纜(lan)線路正序阻抗測(ce)量過(guo)程中有什(shen)么要求(qiu)?
答:電(dian)纜導體的交(jiao)流(liu)電(dian)阻和電(dian)纜三相(xiang)同(tong)感(gan)抗的相(xiang)量和稱為正(zheng)序阻抗。
電(dian)纜線路的(de)正(zheng)序(xu)阻抗一般可在電(dian)纜盤上(shang)直接測(ce)量(liang),測(ce)量(liang)時(shi)(shi)一般使用(yong)較(jiao)低的(de)電(dian)壓(ya),因此,需要用(yong)降壓(ya)變壓(ya)器進行降壓(ya),降壓(ya)器采用(yong)星形接線,容量(liang)一般為10kVA以上(shang),有較(jiao)廣的(de)電(dian)壓(ya)調(diao)節范圍,測(ce)量(liang)時(shi)(shi)交流電(dian)源應比較(jiao)穩(wen)定,以保證測(ce)量(liang)時(shi)(shi)電(dian)流達到規定的(de)要求(qiu),實際電(dian)壓(ya)表的(de)讀(du)數值(zhi)必須是(shi)電(dian)纜端(duan)的(de)電(dian)壓(ya),試驗(yan)電(dian)流更好 接近電(dian)纜長(chang)期允許載(zai)流量(liang),測(ce)讀(du)各表計的(de)數值(zhi)時(shi)(shi),合上(shang)電(dian)流后同時(shi)(shi)讀(du)取三個表的(de)數值(zhi)。
76、根據《電業生產安全規定》,電氣工作人(ren)員必須(xu)具備的(de)條件是什(shen)么?
答:必須具(ju)備(bei)下列條件:
(1)經(jing)醫生鑒定身(shen)體健康,無妨礙工作的病癥;
(2)具備必要的電氣知識,按其職務和工作性質掌(zhang)握(wo)相關的規程、專業技術(shu)(shu)及安全操作技術(shu)(shu),并(bing)經考試合格;
(3)熟(shu)練掌握觸電急救方(fang)法。
77、電纜在運輸裝卸過程中應注意什么?
答:(1)在(zai)運輸裝卸過(guo)程中,不(bu)應(ying)使(shi)電纜(lan)及電纜(lan)盤受到損傷,嚴禁將電纜(lan)盤直(zhi)接(jie)由車上推下,電纜(lan)般不(bu)應(ying)平放(fang)運輸,平放(fang)貯存。
(2)運輸或滾動電(dian)纜盤(pan)前,必須保證(zheng)電(dian)纜盤(pan)牢固(gu),電(dian)纜繞緊、充油(you)(you)電(dian)纜至(zhi)壓力(li)油(you)(you)箱間的油(you)(you)管應固(gu)定,不得(de)損傷,壓力(li)油(you)(you)箱應牢固(gu),壓力(li)指(zhi)示應符合要求。
78、電(dian)纜防火有哪些措施?
答:(1)采用阻燃電纜(lan);
(2)采用防火電纜托架(jia);
(3)采用防火(huo)涂料(liao);
(4)電纜隧道、夾層(ceng)出口等處設置(zhi)防火隔墻、防火擋板;
(5)架空電(dian)纜應避開油管(guan)道、防(fang)爆門,否則應有要取局部(bu)穿管(guan)或隔熱防(fang)火措施(shi)。
79、選(xuan)擇電力電纜(lan)的截面應從哪幾個方面考(kao)慮?
答:應考慮如下(xia)幾個(ge)方(fang)面(mian):
(1)電纜長期允許通過的(de)工作電流;
(2)一旦(dan)短路時的熱穩定性(xing);
(3)線路上(shang)的電壓降不(bu)能超(chao)出允許工作(zuo)范(fan)圍。
80、電力(li)電纜和架(jia)空(kong)線比較有哪些優點?
答:(1)運行可(ke)靠(kao),由于安裝在(zai)地下等(deng)隱蔽處,受外力破壞(huai)小,發生故障的機會較(jiao)少,供電(dian)安全,不會給(gei)人(ren)身造成危害;
(2)維(wei)護工作量小,不需(xu)頻(pin)繁(fan)的巡檢;
(3)不需架設桿塔;
(4)有助于(yu)提高(gao)功(gong)率因數(shu)。