1、常(chang)用的電(dian)(dian)線(xian)、電(dian)(dian)纜按用途分有哪些種(zhong)類?
答:按用途可分為(wei)裸導線、絕(jue)緣電(dian)(dian)線、耐熱電(dian)(dian)線、屏蔽電(dian)(dian)線、電(dian)(dian)力電(dian)(dian)纜、控制電(dian)(dian)纜、通信電(dian)(dian)纜、射頻電(dian)(dian)纜等。
2、絕緣電(dian)線有哪幾種(zhong)?
答:常有的(de)絕緣(yuan)(yuan)(yuan)電(dian)線(xian)(xian)(xian)(xian)有以下(xia)幾種:聚(ju)氯(lv)(lv)(lv)乙烯(xi)絕緣(yuan)(yuan)(yuan)電(dian)線(xian)(xian)(xian)(xian)、聚(ju)氯(lv)(lv)(lv)乙烯(xi)絕緣(yuan)(yuan)(yuan)軟(ruan)線(xian)(xian)(xian)(xian)、丁(ding)腈聚(ju)氯(lv)(lv)(lv)乙烯(xi)混(hun)合物絕緣(yuan)(yuan)(yuan)軟(ruan)線(xian)(xian)(xian)(xian)、橡皮絕緣(yuan)(yuan)(yuan)電(dian)線(xian)(xian)(xian)(xian)、農用地下(xia)直埋鋁芯(xin)塑料絕緣(yuan)(yuan)(yuan)電(dian)線(xian)(xian)(xian)(xian)、橡皮絕緣(yuan)(yuan)(yuan)棉紗紡織軟(ruan)線(xian)(xian)(xian)(xian)、聚(ju)氯(lv)(lv)(lv)乙烯(xi)絕緣(yuan)(yuan)(yuan)尼龍護(hu)套電(dian)線(xian)(xian)(xian)(xian)、電(dian)力和(he)照明用聚(ju)氯(lv)(lv)(lv)乙烯(xi)絕緣(yuan)(yuan)(yuan)軟(ruan)線(xian)(xian)(xian)(xian)等。
3、電纜橋(qiao)架適合(he)于何(he)種場合(he)?
答:電(dian)纜橋架適用于(yu)一般工礦企業室內(nei)外架空敷(fu)設(she)電(dian)力電(dian)纜、控(kong)制電(dian)纜,亦(yi)可(ke)用于(yu)電(dian)信、廣播電(dian)視(shi)等部(bu)門在室內(nei)外架設(she)。
4、電纜附(fu)件有哪些(xie)?
答:常(chang)用的(de)電附(fu)件有電纜終端(duan)接(jie)(jie)線盒(he)、電纜中間(jian)接(jie)(jie)線盒(he)、連接(jie)(jie)管(guan)及(ji)接(jie)(jie)線端(duan)子、鋼(gang)板接(jie)(jie)線槽、電纜橋架等。
5、什么叫電纜中間接頭(tou)?
答:連(lian)(lian)接電(dian)纜與電(dian)纜的導(dao)體、絕(jue)緣屏蔽(bi)層(ceng)和保護層(ceng),以使電(dian)纜線路連(lian)(lian)接的裝置,稱(cheng)為電(dian)纜中間(jian)接頭。
6、什么叫電氣主接(jie)線?
答:電氣主接線是(shi)發電廠、變(bian)電所中主要(yao)電氣設(she)備和母線的(de)連接方(fang)式,包(bao)括(kuo)主母線和廠用電系(xi)統按(an)一定(ding)的(de)功能要(yao)求的(de)連接方(fang)式。
7、在選擇電(dian)力電(dian)纜的(de)截面時,應(ying)遵照哪(na)些規定(ding)?
答:電(dian)(dian)力(li)電(dian)(dian)纜(lan)的選擇應(ying)遵照以下原(yuan)則:(1)電(dian)(dian)纜(lan)的額(e)定(ding)電(dian)(dian)壓(ya)(ya)(ya)要(yao)大于或(huo)等于安(an)裝點供電(dian)(dian)系統(tong)(tong)的額(e)定(ding)電(dian)(dian)壓(ya)(ya)(ya);(2)電(dian)(dian)纜(lan)持續(xu)容(rong)許(xu)電(dian)(dian)流應(ying)等于或(huo)大于供電(dian)(dian)負載的更大 持續(xu)電(dian)(dian)流;(3)線芯截(jie)面要(yao)滿足供電(dian)(dian)系統(tong)(tong)短路時的穩定(ding)性的要(yao)求;(4)根據(ju)電(dian)(dian)纜(lan)長度驗算(suan)電(dian)(dian)壓(ya)(ya)(ya)降是否符合(he)要(yao)求;(5)線路末端的最小短路電(dian)(dian)流應(ying)能使保護裝置可靠的動(dong)作。
8、交聯聚(ju)乙烯電(dian)纜(lan)和(he)油(you)紙(zhi)電(dian)纜(lan)比較(jiao)有哪些優點?
答:(1)易安(an)裝,因為它允許最小彎曲(qu)半徑小、且重量(liang)輕;(2)不受線路落差*;(3)熱性能好(hao),允許工(gong)作溫度高、傳輸(shu)容量(liang)大;(4)電纜附件(jian)簡(jian)單,均(jun)為干式結構;(5)運行維護簡(jian)單,無漏油問題;(6)價格較低;(7)可靠性高、故障(zhang)率(lv)低;(8)制造工(gong)序少、工(gong)藝(yi)簡(jian)單,經濟效益顯(xian)著。
9、固定(ding)交流單芯(xin)電(dian)纜的(de)夾(jia)具有什么要(yao)求?為什么?
答:夾具應無鐵件構成閉合磁(ci)(ci)路,這是因(yin)為當電(dian)(dian)(dian)纜線(xian)芯(xin)通過(guo)電(dian)(dian)(dian)流時,在其周(zhou)圍產(chan)(chan)生磁(ci)(ci)力線(xian),磁(ci)(ci)力線(xian)與通過(guo)線(xian)芯(xin)的電(dian)(dian)(dian)流大小成正比,若使用(yong)鐵件等導磁(ci)(ci)材料(liao),根據(ju)電(dian)(dian)(dian)磁(ci)(ci)感應可知,將在鐵件中產(chan)(chan)生渦流使電(dian)(dian)(dian)纜發(fa)熱,甚至燒壞(huai)電(dian)(dian)(dian)纜。所以(yi)不可使用(yong)鐵件作(zuo)單(dan)芯(xin)交流電(dian)(dian)(dian)纜的固(gu)定(ding)夾具。
10、以下(xia)的熱縮電纜頭(tou)的附(fu)件的更(geng)大(da) 特點和優點是(shi)什么?
答(da):熱縮附(fu)件的更大 特點(dian)是(shi)用應力(li)管代替傳統(tong)的應力(li)錐(zhui),它不僅簡化了(le)施工工藝,還縮小了(le)接頭的終端(duan)的尺(chi)寸,安裝方(fang)便,省時省工,性能優越,節約金屬。熱縮電纜附(fu)件集灌注式(shi)和干包式(shi)為一體,集合了(le)這兩種附(fu)件的優點(dian)。
11、電(dian)纜敷設前應進行哪些檢查工作?
答:(1)支架(jia)應齊全、油(you)(you)漆完整(zheng)。(2)電(dian)(dian)(dian)(dian)纜型號、電(dian)(dian)(dian)(dian)壓(ya)(ya)、規格符合(he)設計。(3)電(dian)(dian)(dian)(dian)纜絕緣良好,當對油(you)(you)紙電(dian)(dian)(dian)(dian)纜的密(mi)封有(you)懷(huai)疑時,應進行受(shou)潮判斷;直埋電(dian)(dian)(dian)(dian)纜與(yu)小底電(dian)(dian)(dian)(dian)纜應經(jing)直流耐壓(ya)(ya)試難合(he)格;充(chong)油(you)(you)電(dian)(dian)(dian)(dian)纜的油(you)(you)樣應試驗合(he)格。(4)充(chong)油(you)(you)電(dian)(dian)(dian)(dian)纜的油(you)(you)壓(ya)(ya)不宜(yi)低于(yu)1.47MPa。
11、交(jiao)聯熱(re)收縮電纜附件有哪些優點?
答(da):這是一種新型(xing)材料,它與現在其他類型(xing)附(fu)件比較具有電氣性能優(you)越、體積小、質(zhi)量小、安裝(zhuang)簡便、材料配套等優(you)點,另(ling)外還具有耐氣候、抗污穢性、阻燃(ran)自熄等能力(li)。
12、對(dui)油紙(zhi)絕緣電(dian)(dian)力電(dian)(dian)纜密封(feng)有懷(huai)疑時,如何(he)用(yong)較簡單的辦法檢查電(dian)(dian)纜絕緣紙(zhi)是否受潮(chao)?
答:把電纜絕緣紙點(dian)燃(ran)或放(fang)入150℃左右的電纜油(you)中檢查(cha),無“嘶嘶”聲或白(bai)色泡沫出(chu)現,說明未受(shou)潮(chao)。
13、電纜(lan)標志牌應注明什么(me)內容?編寫有(you)何要(yao)求?
答:標志牌(pai)上應注(zhu)明電(dian)纜線(xian)路設計編號、電(dian)纜型號、規格及始點,并聯使用(yong)的電(dian)纜應有順序號。要求(qiu)字跡清(qing)晰(xi)、不易脫落。
14、直埋電(dian)纜的方位標志應設置在(zai)哪些位置?
答:在電(dian)纜兩端(duan),電(dian)纜直線段50~100m處電(dian)纜接頭幾(ji)電(dian)纜改變方向的彎(wan)角處。
15、制作電纜接頭用的黃(huang)臘綢帶、黑玻璃漆(qi)帶、無堿玻璃絲帶等,施工(gong)前如(ru)何進行排潮處理?
答:(1)恒(heng)(heng)溫干燥(zao)法(fa):將(jiang)(jiang)絕緣(yuan)帶(dai)卷(juan)成直徑(jing)為25~30mm小(xiao)卷(juan),放(fang)入(ru)110~120℃恒(heng)(heng)溫干燥(zao)箱內烘(hong)4~5h,冷卻(que)干取出(chu),放(fang)入(ru)干燥(zao)的(de)密封(feng)筒內。(2)油(you)浸排(pai)潮法(fa):將(jiang)(jiang)絕緣(yuan)帶(dai)小(xiao)卷(juan)放(fang)入(ru)恒(heng)(heng)溫在120~130℃的(de)電(dian)纜油(you)中(zhong),離(li)(li)鍋底保持(chi)30mm距離(li)(li),經一(yi)定時(shi)間后油(you)面不再產(chan)生泡沫后取出(chu),裝入(ru)貯有(you)電(dian)纜油(you)的(de)桶中(zhong),油(you)位應超過所有(you)裝入(ru)的(de)物體并將(jiang)(jiang)其密封(feng)。
16、電纜外護層的作用是什么?
答:保(bao)護(hu)內護(hu)層不受機械損傷和化(hua)學腐蝕,增強機械強度。
17、室外電纜(lan)溝應(ying)符合哪些(xie)要求?
答:電纜溝(gou)上(shang)部應比地(di)面稍高(gao),加(jia)蓋(gai)用混(hun)凝(ning)土(tu)制作(zuo)的蓋(gai)板,電纜應平敷在(zai)支架上(shang),有良(liang)好的排水管。
18、電纜內護層的作用是什么?
答;使絕緣(yuan)(yuan)層(ceng)不(bu)(bu)會(hui)與水、空氣或(huo)其他物體接觸,防止絕緣(yuan)(yuan)受(shou)潮和絕緣(yuan)(yuan)層(ceng)不(bu)(bu)受(shou)機(ji)械傷害。
19、使(shi)用鋼絲鉗(qian)時應注意些什么(me)?
答:使用前,一定要檢查絕緣(yuan)柄的絕緣(yuan)是否完好(hao)無損(sun),使用時(shi)不可用鋼(gang)絲(si)鉗剪切超(chao)過規格所允許(xu)的金(jin)屬線材,并(bing)禁止用鋼(gang)絲(si)鉗代替錘子敲打(da)工具,以免損(sun)壞。
20、什么叫(jiao)絕緣強度?
答(da):絕緣物質(zhi)在(zai)電場(chang)(chang)中,當電場(chang)(chang)強度增大到某(mou)一(yi)極(ji)限時就會被(bei)擊(ji)穿(chuan),這個導(dao)致絕緣擊(ji)穿(chuan)的(de)電場(chang)(chang)強度稱(cheng)為絕緣強度。
22、對電纜導(dao)體(ti)連接點的機械(xie)強度(du)有(you)何(he)要求(qiu)?
答:連(lian)接點的(de)機械強(qiang)(qiang)度,一般低于(yu)(yu)電纜(lan)導(dao)體本身(shen)的(de)抗拉強(qiang)(qiang)度,對于(yu)(yu)固定敷設的(de)電力(li)電纜(lan),其連(lian)接點的(de)抗拉強(qiang)(qiang)度要求(qiu)不(bu)低于(yu)(yu)導(dao)體本身(shen)抗拉強(qiang)(qiang)度的(de)60%。
23、電力電纜的絕緣(yuan)層材料(liao)應具備哪些(xie)主要性能?
答;應具(ju)備下列主要(yao)性(xing)能:(1)高(gao)的(de)(de)擊穿(chuan)強度(du);(2)低的(de)(de)介(jie)質損耗;(3)相當(dang)高(gao)的(de)(de)絕(jue)緣電(dian)阻(zu);(4)優良(liang)的(de)(de)耐放電(dian)性(xing)能;(5)具(ju)有一定的(de)(de)柔軟性(xing)和機械強度(du);(6)絕(jue)緣性(xing)能長期穩定。
24、機械敷設電纜時,牽引強度有何(he)規定(ding)?
答:對于銅芯電(dian)纜,當牽(qian)(qian)引(yin)頭(tou)部時(shi),允(yun)許(xu)牽(qian)(qian)引(yin)強度為(wei)70N/cm;對于鋁(lv)芯電(dian)纜,當牽(qian)(qian)引(yin)頭(tou)部時(shi),允(yun)許(xu)牽(qian)(qian)引(yin)強度為(wei)40N/cm;若利用鋼絲網(wang)套(tao)(tao)牽(qian)(qian)引(yin)時(shi),鉛護套(tao)(tao)電(dian)纜允(yun)許(xu)強度為(wei)10N/cm;鉛護套(tao)(tao)電(dian)纜為(wei)40N/cm。
25、對電纜保(bao)護管(guan)有何規定?
答:(1)電纜需要穿保護管(guan)(guan)(guan)(guan)敷設時,管(guan)(guan)(guan)(guan)子內(nei)徑(jing)不(bu)應(ying)(ying)小于電纜外徑(jing)的(de)(de)1.5倍,混凝(ning)土管(guan)(guan)(guan)(guan)、陶土管(guan)(guan)(guan)(guan)、石(shi)棉、水泥管(guan)(guan)(guan)(guan)的(de)(de)內(nei)徑(jing)不(bu)應(ying)(ying)小于100mm;
(2)電(dian)纜(lan)管的(de)彎曲(qu)半徑應符(fu)合所穿(chuan)入電(dian)纜(lan)彎曲(qu)半徑的(de)規定;
(3)每根管子最多(duo)不應超過三個彎頭(tou),直角彎不應多(duo)于2個。
26、如何測量(liang)電纜(lan)護(hu)套的外徑?
答:在護套(tao)圓(yuan)周(zhou)上均(jun)勻(yun)分布(bu)的五(wu)點處,測量護套(tao)外徑和(he)其平均(jun)值,其平均(jun)外徑既為護套(tao)的外徑。
27、不同截(jie)面(mian)的(de)銅芯電纜如何連接(jie)?
答:不(bu)同截面(mian)的銅(tong)(tong)(tong)芯電(dian)纜(lan)連(lian)接(jie),可采用(yong)(yong)開口弱背(bei)銅(tong)(tong)(tong)接(jie)管,以錫焊法連(lian)接(jie),也可用(yong)(yong)純銅(tong)(tong)(tong)棒(bang)按不(bu)同的截面(mian)要求連(lian)接(jie)成銅(tong)(tong)(tong)接(jie)管,以壓接(jie)法連(lian)接(jie)。
28、簡述10KV交聯電纜熱縮式制作戶內終端頭的過程?
答;(1)準備(bei)階(jie)段:檢查熱(re)縮(suo)電(dian)纜(lan)附件(jian)是否(fou)齊備(bei),型號是否(fou)相配,檢查并確認電(dian)纜(lan)有無(wu)潮氣后(hou),檢查電(dian)纜(lan)。
(2)切除(chu)多余電(dian)纜,根據現場情(qing)況決定電(dian)纜長(chang)度。
(3)剝除護層(ceng)。
(4)焊(han)(han)接(jie)接(jie)地(di)線,將(jiang)接(jie)地(di)線焊(han)(han)接(jie)在(zai)鋼帶(dai)上。
(5)填充三叉口及繞包密封膠。
(6)安裝三(san)芯分支護套,將護套套入根(gen)部,從中部開始(shi)收縮,先(xian)往根(gen)部,再往指部。
(7)剝(bo)銅(tong) 帶(dai)和外(wai)半(ban)導電(dian)層,剝(bo)切(qie)三芯分支套口(kou)20mm以上的銅(tong)帶(dai),嚴禁損傷主絕緣(yuan),清除干凈半(ban)導電(dian)層。
(8)安裝應力管(guan),管(guan)口端(duan)部分支套對接后(hou)熱縮。
(9)安裝接線端子。
(10)安裝絕緣管。
(11)安裝(zhuang)密封管。
(12)核相后安裝相色管。
29、戶內(nei)、戶外預制式終端安裝(zhuang)步驟(zou)有哪些?
答:(1) 將電纜按(an)預定位置就位、固定、清潔表面(mian),參照說明書剝除外護(hu)套,如有特殊(shu)需(xu)要,外護(hu)套剝切長度(du)可調整,分別由(you)銅帶、外護(hu)套鎧裝(zhuang)引出2組地(di)線(xian)。
(2) 由外(wai)護套(tao)(tao)(tao)口(kou)向(xiang)上(shang)(shang)量取(qu)需要尺寸(cun),切除多余電纜,套(tao)(tao)(tao)入熱(re)縮三指套(tao)(tao)(tao)至三叉口(kou)根部由中(zhong)間加熱(re)收縮,由指套(tao)(tao)(tao)上(shang)(shang)口(kou)向(xiang)上(shang)(shang)量取(qu)規定尺寸(cun)(35kv為350~380mm)。去掉多余銅(tong)帶(保留(liu)20mm),再保留(liu)半導(dao)體預定位置,壓接(jie)出線端子(zi)密封。
30、電(dian)線電(dian)纜的應用主(zhu)要(yao)分為三大類 :
(1)、電力系統
電(dian)(dian)力(li)系統采用的電(dian)(dian)線(xian)(xian)(xian)(xian)(xian)電(dian)(dian)纜(lan)產品主要(yao)有架空(kong)裸(luo)電(dian)(dian)線(xian)(xian)(xian)(xian)(xian)、匯流(liu)排(pai)(母(mu)線(xian)(xian)(xian)(xian)(xian))、電(dian)(dian)力(li)電(dian)(dian)纜(lan)(塑料線(xian)(xian)(xian)(xian)(xian)纜(lan)、油紙(zhi)力(li)纜(lan)(基本被(bei)塑料電(dian)(dian)力(li)電(dian)(dian)纜(lan)代替(ti))、橡套線(xian)(xian)(xian)(xian)(xian)纜(lan)、架空(kong)絕緣電(dian)(dian)纜(lan))、分支電(dian)(dian)纜(lan)(取代部(bu)分母(mu)線(xian)(xian)(xian)(xian)(xian))、電(dian)(dian)磁線(xian)(xian)(xian)(xian)(xian)以及電(dian)(dian)力(li)設備(bei)用電(dian)(dian)氣裝備(bei)電(dian)(dian)線(xian)(xian)(xian)(xian)(xian)電(dian)(dian)纜(lan)等(deng)。
(2)、信息傳輸系(xi)統(tong)
用于信息傳輸系統的電(dian)(dian)(dian)線電(dian)(dian)(dian)纜(lan)(lan)(lan)(lan)主要有市話電(dian)(dian)(dian)纜(lan)(lan)(lan)(lan)、電(dian)(dian)(dian)視電(dian)(dian)(dian)纜(lan)(lan)(lan)(lan)、電(dian)(dian)(dian)子線纜(lan)(lan)(lan)(lan)、射頻電(dian)(dian)(dian)纜(lan)(lan)(lan)(lan)、光纖纜(lan)(lan)(lan)(lan)、數據電(dian)(dian)(dian)纜(lan)(lan)(lan)(lan)、電(dian)(dian)(dian)磁線、電(dian)(dian)(dian)力通訊或其他復合電(dian)(dian)(dian)纜(lan)(lan)(lan)(lan)等(deng)。
(3)、機(ji)械(xie)設(she)備(bei)、儀(yi)器儀(yi)表系統(tong)
此部(bu)分除(chu)架空裸(luo)電線(xian)(xian)外幾乎(hu)其(qi)他所有產品均有應用,但主要是電力(li)電纜(lan)、電磁線(xian)(xian)、數據電纜(lan)、儀器(qi)儀表線(xian)(xian)纜(lan)等。
31、電線電纜產品主要分為五大類:
(1)、裸電線(xian)及裸導體(ti)制品 本類產(chan)品的主(zhu)要(yao)特(te)征是(shi):純的導體(ti)金屬(shu),無絕緣及護套層(ceng),如鋼(gang)芯鋁絞(jiao)線(xian)、銅(tong)鋁匯(hui)流排(pai)、電力(li)機車線(xian)等(deng)(deng);加(jia)(jia)工工藝主(zhu)要(yao)是(shi)壓(ya)力(li)加(jia)(jia)工,如熔煉、壓(ya)延、拉制、絞(jiao)合/緊壓(ya)絞(jiao)合等(deng)(deng);產(chan)品主(zhu)要(yao)用(yong)在城郊、農村、用(yong)戶主(zhu)線(xian)、開關柜(ju)等(deng)(deng)。
(2)、電(dian)(dian)(dian)力(li)電(dian)(dian)(dian)纜本類產品(pin)主要特征(zheng)是(shi):在導體外擠(繞)包絕緣(yuan)層,如(ru)架(jia)空(kong)絕緣(yuan)電(dian)(dian)(dian)纜,或(huo)幾芯(xin)絞(jiao)合(he)(he)(對應電(dian)(dian)(dian)力(li)系統的(de)(de)相(xiang)線、零(ling)線和地線),如(ru)二芯(xin)以上(shang)架(jia)空(kong)絕緣(yuan)電(dian)(dian)(dian)纜,或(huo)再(zai)增加護套層,如(ru)塑料/橡套電(dian)(dian)(dian)線電(dian)(dian)(dian)纜。主要的(de)(de)工藝技術(shu)有拉制、絞(jiao)合(he)(he)、絕緣(yuan)擠出(繞包)、成纜、鎧裝、護層擠出等,各(ge)種產品(pin)的(de)(de)不同工序組合(he)(he)有一(yi)定(ding)區別(bie)。
產品主要用(yong)在發、配、輸、變(bian)、供電(dian)線路中的強電(dian)電(dian)能傳輸,通過的電(dian)流(liu)大(da)(幾十安(an)至(zhi)(zhi)幾千安(an))、電(dian)壓高(220V至(zhi)(zhi)500kV及以(yi)上)。
(3)、電(dian)氣裝(zhuang)備(bei)用(yong)電(dian)線(xian)電(dian)纜該(gai)類產品(pin)主要特征是:品(pin)種規格繁多,應用(yong)范圍廣泛,使用(yong)電(dian)壓在1kV及(ji)以(yi)下(xia)較(jiao)多,面對特殊場合不斷(duan)衍生新的產品(pin),如(ru)耐火線(xian)纜、阻燃線(xian)纜、低煙(yan)無鹵/低煙(yan)低鹵線(xian)纜、防白蟻(yi)、防老鼠線(xian)纜、耐油/耐寒(han)/耐溫/耐磨線(xian)纜、醫用(yong)/農用(yong)/礦用(yong)線(xian)纜、薄壁(bi)電(dian)線(xian)等。
(4)、通(tong)訊(xun)(xun)電纜(lan)及光纖(簡略介紹)隨著(zhu)近二十多年來,通(tong)訊(xun)(xun)行業的飛速(su)(su)發(fa)展(zhan),產品也有驚人的發(fa)展(zhan)速(su)(su)度(du)。從過去(qu)的簡單的電話電報線纜(lan)發(fa)展(zhan)到(dao)幾千對的話纜(lan)、同軸纜(lan)、光纜(lan)、數據電纜(lan),甚至組合通(tong)訊(xun)(xun)纜(lan)等。
該(gai)類產品結(jie)構尺寸通(tong)常(chang)較小而均(jun)勻(yun),制造精度要(yao)求高。
(5)、電磁線(xian)(繞組線(xian))主(zhu)要用(yong)于各種電機、儀器儀表(biao)等。
電(dian)線電(dian)纜的衍(yan)生(sheng)/新產品
電線電纜的衍生/新(xin)產品(pin)主(zhu)要是因應用(yong)(yong)場(chang)合(he)、應用(yong)(yong)要求不同(tong)及裝備的方便(bian)性和(he)降低裝備成(cheng)本(ben)等(deng)的要求,而采用(yong)(yong)新(xin)材料、特殊材料、或改(gai)變(bian)產品(pin)結(jie)構、或提高工(gong)藝要求、或將不同(tong)品(pin)種的產品(pin)進(jin)行組合(he)而產生。
采用不同材料如(ru)阻燃(ran)線(xian)纜、低(di)煙(yan)無鹵/低(di)煙(yan)低(di)鹵線(xian)纜、防白蟻、防老鼠線(xian)纜、耐(nai)(nai)油(you)/耐(nai)(nai)寒(han)/耐(nai)(nai)溫線(xian)纜等;
改變產(chan)品結構如:耐(nai)火電(dian)纜等(deng);
提高工藝要求如(ru):醫用線纜等;
組合產品如(ru):OPGW等;
方便(bian)安裝和降(jiang)低裝備成(cheng)本如:預制分支電纜等。
32、母(mu)線裝(zhuang)置施工完(wan),應進行哪些檢查(cha)?
答:應進(jin)行(xing)下列檢查(cha):
(1)金屬(shu)構件(jian)的加工(gong)、配制、焊接螺接應(ying)符合規定;
(2)各(ge)部(bu)螺(luo)栓、墊圈、開口(kou)銷等零部(bu)件應(ying)齊全(quan)可靠;
(3)母線配制(zhi)及安裝架應符合規定,相(xiang)間及對地電氣距離符合要求;
(4)瓷件、鐵(tie)件及膠合處(chu)應完整,充油套管應無滲油,油位(wei)正(zheng)常;
(5)油漆完整(zheng),相色正確,接地良好。
33、在35kv及以下電力電纜接(jie)頭中,改善其(qi)護套(tao)斷開處電場分布的方(fang)法有(you)幾種(請列出五(wu)種),并簡述其(qi)方(fang)法。
答(da):(1)脹喇叭(ba)(ba)口:在鉛包割(ge)斷處把鉛包邊緣撬起,成喇叭(ba)(ba)狀,其邊緣應光滑、圓整、對(dui)稱。
(2)預(yu)留(liu)統包絕緣(yuan)(yuan):在鉛包切口至電纜芯線分開(kai)點之間留(liu)有一段統包絕緣(yuan)(yuan)紙。
(3)切除半(ban)導電紙:將半(ban)導電紙切除到喇叭口以下(xia)。
(4)包(bao)(bao)繞應(ying)力(li)錐:用絕緣包(bao)(bao)帶(dai)和導電金屬材料包(bao)(bao)成錐形,人為地將屏蔽(bi)層擴大(da),以(yi)改善電場分布。
(5)等(deng)電(dian)位法(fa):對于干包型或交聯(lian)聚乙烯電(dian)纜頭,在各(ge)線芯概(gai)況絕緣表面上包一段金屬帶(dai),并將其連(lian)接在一起。
(6)裝(zhuang)設(she)應(ying)力控制(zhi)管:對于35kv及發下熱(re)縮管電纜頭,首先(xian)從線(xian)芯(xin)銅屏(ping)蔽層末(mo)(mo)端(duan)方(fang)向經(jing)半導體(ti)帶(dai)至線(xian)芯(xin)絕緣概況包(bao)繞2層半導體(ti)帶(dai),然(ran)后將相應(ying)規格折應(ying)力管,套(tao)在銅屏(ping)蔽的末(mo)(mo)端(duan)處,熱(re)縮成(cheng)形(xing)。
34、電纜支架的加(jia)工應符(fu)合哪些要求?
答:(1)鋼材(cai)應平直,無(wu)明顯(xian)扭(niu)曲,下料誤(wu)差應在5mm范圍內,切(qie)口應無(wu)卷邊,毛剌(la);
(2)支架(jia)應(ying)焊接牢固,無(wu)顯蓍(shi)變形(xing),各橫撐間的垂(chui)直凈距與(yu)設計(ji)偏差不(bu)應(ying)大(da)于5mm;
(3)金屬支架必須進(jin)行防腐處(chu)理,位于濕熱、鹽(yan)、霧以及有化學腐蝕地區時,應根據(ju)設計作特殊的(de)防腐處(chu)理。
35、列(lie)舉出你熟悉的(de)電纜架(jia)。
答:拼焊式(shi)E型(xing)架(jia)(jia)、裝(zhuang)配式(shi)E型(xing)架(jia)(jia)、橋式(shi)電(dian)纜架(jia)(jia)、電(dian)纜托架(jia)(jia)、掛鉤式(shi)支(zhi)架(jia)(jia)、單根電(dian)纜支(zhi)架(jia)(jia)等。
36、敷設(she)電纜應滿(man)足(zu)哪些要求(qiu)?
答(da):應滿足以下要求:
(1)安全運行方面,盡可(ke)能避免各種外來損壞,提(ti)高電(dian)纜線(xian)路(lu)的供電(dian)可(ke)靠性;
(2)經濟方面(mian),從投資(zi)最省的方面(mian)考慮;
(3)施工方面,電纜線路的(de)路徑必須便于旋(xuan)工和投運后的(de)維修。
37、制作電纜終端頭(tou)或(huo)中間(jian)接頭(tou)的絕(jue)緣材料(liao)有哪些?
答(da):有(you)絕(jue)(jue)緣(yuan)膠、絕(jue)(jue)緣(yuan)帶、絕(jue)(jue)緣(yuan)管、絕(jue)(jue)緣(yuan)手套、絕(jue)(jue)緣(yuan)樹(shu)脂(zhi)等。
38、簡述電纜頭制(zhi)(zhi)作(zuo)的一般操作(zuo)程序(xu)。答:(1)制(zhi)(zhi)作(zuo)前的準備:包括○1閱讀安(an)裝說明書;○2察(cha)看(kan)現場(chang);○3備料(liao);○4電纜試(shi)(shi)潮;○5制(zhi)(zhi)作(zuo)前測試(shi)(shi)等。
(2)接頭(tou)的制作(zuo)過程:包括○1割斷多余電(dian)纜(lan);○2電(dian)纜(lan)保護層的剝切;○3導(dao)體連(lian)接;○4包繞絕緣(yuan)(yuan)(或收縮管材);○5安裝接頭(tou)外殼(ke);○6灌注絕緣(yuan)(yuan)劑(ji);○7進行密封處理(li)等。
(3)制(zhi)作后電(dian)氣(qi)測試。
39、電纜保護管的加工(gong)應符合哪些要求?
答(da):(1)管(guan)口(kou)應(ying)*剌和(he)尖銳(rui)楞角,管(guan)口(kou)宜做成喇叭形(xing)。
(2)電(dian)纜(lan)(lan)管在彎(wan)制后,不(bu)應有裂縫和顯著的(de)(de)凹(ao)癟現象,其彎(wan)扁程度不(bu)宜(yi)大(da)于(yu)(yu)管子外徑10%;電(dian)纜(lan)(lan)管的(de)(de)彎(wan)曲(qu)半徑不(bu)應小(xiao)(xiao)于(yu)(yu)所穿(chuan)入電(dian)纜(lan)(lan)的(de)(de)最小(xiao)(xiao)允許彎(wan)曲(qu)半徑。
(3)金屬管(guan)應(ying)在外表(biao)涂防(fang)腐(fu)漆或瀝表(biao),鍍鋅(xin)(xin)管(guan)鋅(xin)(xin)層剝落處也應(ying)涂以防(fang)腐(fu)漆。
40、電纜的排列符合哪些要求?答:(1)電力電纜和控纜不應配置在同一層支(zhi)架上。
(2)高(gao)、低(di)壓(ya)電(dian)(dian)纜,強、弱電(dian)(dian)控(kong)纜應(ying)按(an)須序分層(ceng)配(pei)置,一般情(qing)況宜由上(shang)而下(xia),但在(zai)含有35kv以(yi)上(shang)高(gao)壓(ya)電(dian)(dian)纜引入柜盤(pan)時,為滿足彎曲半徑,可由下(xia)面上(shang)配(pei)置。
41、電纜(lan)溝內敷設電纜(lan)的方法是什么?
答:在(zai)電纜溝(gou)(gou)內(nei)敷設(she)電纜的(de)方法與直(zhi)埋電纜的(de)敷設(she)方法相仿,一般可將(jiang)滑(hua)輪(lun)放(fang)在(zai)溝(gou)(gou)內(nei),施(shi)放(fang)完畢,將(jiang)電纜放(fang)于溝(gou)(gou)底(di)或支(zhi)架(jia)上,并在(zai)電纜上綁扎電纜標牌。
42、電纜敷設(she)的常用(yong)設(she)備有哪(na)些?
答:(1)空(kong)氣壓縮機(ji),主要(yao)用來破(po)壞(huai)路面,為(wei)以(yi)后敷(fu)設電纜作準備(bei);
(2)電(dian)動卷揚(yang)機或電(dian)纜牽引(yin)機,主要(yao)用來(lai)拖電(dian)纜;
(3)電纜輸送機(ji)(ji),配(pei)合牽(qian)引機(ji)(ji)使用來克服(fu)巨大的摩擦力,減輕對電纜的損壞;
(4)電纜盤(pan)放線支架;
(5)滾輪裝置(zhi);
(6)防捻(nian) ,減鋼絲繩出現的扭(niu)曲(qu);
(7)電纜盤制動裝置;
(8)張(zhang)力(li)計。
43、電纜(lan)溝(gou)中支(zhi)(zhi)架安裝(zhuang)(zhuang)距(ju)離的(de)要(yao)求如(ru)何?答:電纜(lan)固定于(yu)(yu)電纜(lan)溝(gou)和隧道的(de)墻上(shang),水(shui)平裝(zhuang)(zhuang)置時(shi),當電纜(lan)外徑等于(yu)(yu)或小于(yu)(yu)50mm時(shi)應每(mei)(mei)隔1m加(jia)一支(zhi)(zhi)撐;外徑大于(yu)(yu)50mm的(de)電纜(lan)每(mei)(mei)隔0.6m加(jia)一支(zhi)(zhi)撐;排成三角形的(de)單電纜(lan),每(mei)(mei)隔1m應用綁帶扎牢,垂直裝(zhuang)(zhuang)置時(shi),每(mei)(mei)隔1~1.5m加(jia)以固定。
44、如何處理電力電纜(lan)與(yu)控制電纜(lan)在(zai)同(tong)一托(tuo)架的安裝(zhuang)?
答:電(dian)(dian)(dian)力電(dian)(dian)(dian)纜與控制電(dian)(dian)(dian)纜一般(ban)不應敷(fu)設在同一托(tuo)架(jia)內(nei),當電(dian)(dian)(dian)纜較少而將(jiang)控纜與電(dian)(dian)(dian)力電(dian)(dian)(dian)纜敷(fu)設在同一托(tuo)架(jia)內(nei)時,應用隔板隔開(kai)。
45、電(dian)纜隧道內如何(he)裝設接地線?
答:隧道和溝的(de)全長應(ying)裝設連(lian)(lian)續的(de)接(jie)地線(xian)(xian),接(jie)地線(xian)(xian)應(ying)和所有(you)的(de)支(zhi)架(jia)相連(lian)(lian),兩頭和接(jie)地極(ji)連(lian)(lian)通。接(jie)地線(xian)(xian)的(de)規格應(ying)符合(he)設計要求。電(dian)纜鉛(qian)包(bao)和鎧裝除了有(you)絕緣要求外,應(ying)全部相互(hu)連(lian)(lian)接(jie)并和接(jie)地線(xian)(xian)相連(lian)(lian),電(dian)纜架(jia)和接(jie)地線(xian)(xian)均應(ying)涂防銹漆或(huo)鍍鋅。
46、對于電(dian)纜孔洞(dong)的防火(huo)封堵有何(he)要求?
答:對于較大的電(dian)纜貫穿孔(kong)洞(dong),如(ru)電(dian)纜貫穿樓板處等(deng),采(cai)用防火(huo)堵(du)料封堵(du)時,應根據實際(ji)情況,先在電(dian)纜表面(mian)涂四至六層(ceng)防火(huo)涂料,長度自孔(kong)洞(dong)以(yi)(yi)下1.5m左右,再用耐火(huo)材(cai)料加工成具(ju)有(you)(you)一定強度的板托(tuo)防火(huo)堵(du)料,保證封堵(du)后牢(lao)固(gu)并便于更(geng)換電(dian)纜時拆(chai)裝,封堵(du)密(mi)實無孔(kong)隙以(yi)(yi)有(you)(you)效地堵(du)煙(yan)堵(du)火(huo)。
47、噴燈點火前(qian)應注意哪(na)些檢(jian)查?
答(da):應進行(xing)下列各項檢查:
(1)打氣(qi)筒(tong)是(shi)否漏油(you)或滲油(you),油(you)桶及噴嘴(zui)處是(shi)否漏油(you)、漏氣(qi);
(2)油(you)(you)(you)桶(tong)內的油(you)(you)(you)量是否(fou)超過(guo)油(you)(you)(you)桶(tong)容量的3/4,加油(you)(you)(you)的螺絲塞(sai)是否(fou)擰緊。
48、使(shi)用(yong)噴燈應(ying)注(zhu)意哪些事項(xiang)?
答:(1)噴燈更(geng)大 注油(you)量為油(you)筒容積的3/4;
(2)開(kai)始(shi)打氣壓力不要太大(da),點燃后火焰由黃變藍(lan)即(ji)可使(shi)用;
(3)周圍不得有易燃物,空氣要流通;
(4)停用(yong)時先關(guan)閉調(diao)節開關(guan),火熄(xi)后(hou),慢(man)慢(man)旋(xuan)松油孔(kong)(kong)蓋(gai)放氣,空氣放完后(hou),要(yao)(yao)要(yao)(yao)旋(xuan)松調(diao)節開關(guan),完全冷卻后(hou)再旋(xuan)松孔(kong)(kong)蓋(gai);
(5)煤(mei)油(you)(you)噴燈與汽油(you)(you)噴燈要分開使用。
49、手動油壓鉗有何用途?如何操作?
答:兩根導(dao)(dao)(dao)線的(de)連接(jie)(jie)通常是將兩導(dao)(dao)(dao)線端穿入(ru)相同材料制成的(de)壓(ya)(ya)(ya)(ya)(ya)(ya)管(guan)中(zhong),用壓(ya)(ya)(ya)(ya)(ya)(ya)接(jie)(jie)鉗擠壓(ya)(ya)(ya)(ya)(ya)(ya)數個(ge)坑(keng),使(shi)(shi)導(dao)(dao)(dao)線連接(jie)(jie)在一起,壓(ya)(ya)(ya)(ya)(ya)(ya)接(jie)(jie)時(shi),手柄向上抬(tai)起時(shi),柱塞(sai)向外移動(dong),進(jin)油(you)閥下(xia)腔產生(sheng)真空,油(you)箱內(nei)的(de)油(you)進(jin)入(ru)柱塞(sai)腔。手柄下(xia)壓(ya)(ya)(ya)(ya)(ya)(ya)時(shi),柱塞(sai)向內(nei)移動(dong),油(you)受壓(ya)(ya)(ya)(ya)(ya)(ya)后,使(shi)(shi)進(jin)油(you)閥關(guan)閉,打(da)開(kai)出油(you)閥,使(shi)(shi)油(you)壓(ya)(ya)(ya)(ya)(ya)(ya)進(jin)入(ru)液壓(ya)(ya)(ya)(ya)(ya)(ya)缸,推動(dong)活(huo)塞(sai)和陽模,陽、陰模之間放有壓(ya)(ya)(ya)(ya)(ya)(ya)接(jie)(jie)管(guan),當壓(ya)(ya)(ya)(ya)(ya)(ya)接(jie)(jie)被擠壓(ya)(ya)(ya)(ya)(ya)(ya)的(de)坑(keng)深到一定(ding)值時(shi),開(kai)啟回(hui)油(you)閥,活(huo)塞(sai)自動(dong)返回(hui),壓(ya)(ya)(ya)(ya)(ya)(ya)完一個(ge)坑(keng)后,移動(dong)壓(ya)(ya)(ya)(ya)(ya)(ya)鉗,再壓(ya)(ya)(ya)(ya)(ya)(ya)下(xia)一個(ge)。
50、常用低壓(ya)電力電纜按(an)絕緣(yuan)和(he)保(bao)護層的不(bu)同,主要可分為哪幾類?
答:(1)油浸紙(zhi)絕緣鉛包(或鋁包)電力電纜;
(2)不滴流油浸紙絕緣電力電纜;
(3)聚氯乙烯絕(jue)緣聚氯乙烯護套電力電纜(lan);
(4)交聯(lian)聚氯乙烯(xi)絕緣聚乙烯(xi)護套電(dian)力電(dian)纜(lan);
(5)交聯(lian)聚(ju)氯乙(yi)(yi)烯絕緣聚(ju)氯乙(yi)(yi)烯護套電力電纜;
(6)橡皮絕緣(yuan)電力(li)電纜。
51、常用絕緣材料(liao)的類別(bie)哪些?舉例說明(ming)?
答(da):(1)無機(ji)絕(jue)緣材料:有云(yun)母、石(shi)棉(mian)、大理石(shi)、瓷器、玻璃等;
(2)有(you)機絕緣材料:有(you)樹(shu)脂、橡(xiang)膠、紙、麻、棉紗等;
(3)混合絕緣材(cai)料:用以上絕緣材(cai)料加工而成(cheng)型(xing)的名種絕緣材(cai)料。
52、在(zai)哪種(zhong)情況下采用排管敷(fu)設?有什么優(you)點?
答(da):排(pai)管敷設(she)一(yi)般(ban)用在與其(qi)他建筑物、公路(lu)(lu)或鐵路(lu)(lu)相交叉的地(di)方(fang),有時也在建筑物密集(ji)區內采用。主要優點是占地(di)少,能(neng)承受(shou)大的荷(he)重,電纜相互(hu)間互(hu)不影響,比較(jiao)安全。
53、何謂電纜長期允許(xu)載流量(liang)?
答:電纜長期允許(xu)載(zai)流量是指在(zai)電纜內通過規定(ding)電流時,在(zai)熱穩定(ding)后,電纜導體達到長期允許(xu)工作溫度時的電流數值。
54、決定電纜長期允許載流量的因素有哪些?
答:有以(yi)下(xia)三(san)個因素決定:
(1)電纜的長期容(rong)許工作溫度;
(2)電(dian)纜本身的散熱性能(neng);
(3)電纜裝置(zhi)情況及(ji)周圍環境(jing)的散(san)熱條件。
55、電纜(lan)的敷(fu)設方(fang)式有(you)幾種(zhong)?
答:有以下(xia)幾種:
(1)直埋在(zai)地下;
(2)安裝在電纜溝內;
(3)安(an)裝在地下隧(sui)道內;
(4)安裝在建筑(zhu)物內部墻上(shang)或天棚上(shang);
(5)安(an)裝(zhuang)在橋架(jia)上;
(6)敷設在排管內;
(7)敷設(she)在(zai)水底。
56、如何進行電纜管(guan)的連(lian)接工(gong)作?
答(da):電纜(lan)管(guan)(guan)連(lian)接時,必須用(yong)(yong)扣(kou)和(he)管(guan)(guan)接頭連(lian)接,如(ru)采用(yong)(yong)焊(han)接時,不(bu)能直接對(dui)焊(han),連(lian)接處要套上一段粗管(guan)(guan)再進行焊(han)接,以免焊(han)渣掉(diao)入管(guan)(guan)內。
57、制(zhi)作電纜頭時,對上下扳彎電纜芯線有何(he)要求?
答:扳(ban)彎線芯(xin)(xin)(xin)時(shi),不得損傷(shang)(shang)紙絕緣,芯(xin)(xin)(xin)線的(de)彎曲半徑不得小于電纜(lan)線芯(xin)(xin)(xin)的(de)10倍。制作時(shi)要(yao)特別小心(xin),應使(shi)線芯(xin)(xin)(xin)彎曲部分均勻受力(li),否則極易損傷(shang)(shang)絕緣紙。
58、簡述塑料(liao)電纜的熱收縮密封法。
答:熱縮(suo)(suo)法適用(yong)于(yu)(yu)中(zhong)、低壓橡(xiang)、塑電纜(lan)(lan)接頭和(he)終(zhong)端頭的密(mi)封(feng),也可適用(yong)于(yu)(yu)不滴流(liu)和(he)黏性浸漬(zi)絕緣(yuan)電纜(lan)(lan)。采用(yong)交聯聚乙烯型和(he)硅(gui)橡(xiang)膠型兩大類遇熱后能均勻收(shou)縮(suo)(suo)的熱收(shou)縮(suo)(suo)管。將這種管材(cai)套(tao)于(yu)(yu)預(yu)定的粘合密(mi)封(feng)部(bu)位,并(bing)在粘和(he)部(bu)位涂上熱熔膠,當加(jia)熱到一(yi)定溫度(du)后,熱縮(suo)(suo)管將收(shou)縮(suo)(suo),同時(shi)熱熔膠熔化,待自然冷卻后即形成一(yi)道良(liang)好的密(mi)封(feng)封(feng)層。
59、用電動彎管機彎制電纜保護(hu)管時應(ying)注意什么?
答(da):(1)彎管(guan)機應(ying)由了解其性能并(bing)熟悉操(cao)作(zuo)知(zhi)識(shi)的人員操(cao)作(zuo);
(2)使用前必須進行檢查,按鈕、操作把手、行程(cheng)開關(guan)應完好(hao),彎管(guan)機必須可靠接地(di);
(3)選用符合要(yao)求的模具,確定好所需(xu)要(yao)的彎曲(qu)半徑;
(4)施工(gong)場地周圍(wei),應有(you)充足的活動(dong)范(fan)圍(wei);
(5)使用時待空轉正常后,方可帶負(fu)荷(he)工(gong)作,運(yun)行中(zhong),嚴禁用手腳接觸(chu)其(qi)轉動部分;
(6)工作完畢應及時停電,釋放油壓。
60、電纜清冊的(de)內容及電纜編號的(de)含義是什(shen)么?
答:電纜(lan)清冊是施放電纜(lan)和(he)指導施工的(de)依據,運行維護(hu)的(de)檔案資料。應列入(ru)每(mei)根電纜(lan)的(de)編號(hao)(hao)、起始點、型號(hao)(hao)、規格、長(chang)(chang)度,并(bing)分類統計出總長(chang)(chang)度,控(kong)纜(lan)還應列出每(mei)根電纜(lan)的(de)備用芯。
電纜編號是識別電纜的(de)(de)標志,故要求全廠編號不重復,并(bing)且有一定的(de)(de)含義和規律(lv),能表達電纜的(de)(de)特征。
61、電纜(lan)目(mu)前采用的敷設方(fang)法可(ke)分為(wei)幾類(lei)?
答:(1)人工敷設,即采用人海戰術,在一人或多人協調指揮下,按規定(ding)進行(xing)敷設;
(2)機(ji)械(xie)化敷設,即(ji)采用滾(gun)輪、牽引器、輸送機(ji),通過一同步電源進(jin)行控制,比較安全;
(3)人工和機(ji)械相結(jie)合(he),有(you)些現場由于轉彎較多,施(shi)工難度大(da),全用(yong)機(ji)械較困難,所以采(cai)用(yong)此(ci)法。
62、控制二次(ci)回路接線應(ying)符合(he)哪些要求(qiu)?
答:(1)按圖施工接(jie)線正確;
(2)導線的(de)電氣連接(jie)應(ying)牢(lao)固可靠(kao);
(3)盤柜(ju)內的(de)導線不應(ying)有接頭(tou),導線芯線應(ying)無損傷;
(4)電纜芯線端部(bu)應標(biao)明其(qi)回路編(bian)號(hao),編(bian)號(hao)應正(zheng)確,字跡清晰且不(bu)易脫色;
(5)配線(xian)應整(zheng)齊、清晰、美觀,導線(xian)絕(jue)緣應良好、無損;
(6)每(mei)個接線端子的每(mei)側接線宜為一根(gen),最多不得超(chao)過兩(liang)根(gen)。
63、電纜(lan)排(pai)管有何要求?
答:(1)排管(guan)頂部至(zhi)地面(mian)距離,在廠房內為(wei)(wei)0.2m,人(ren)行道下為(wei)(wei)0.5m,一般地區(qu)為(wei)(wei)0.7m;
(2)在(zai)變更方(fang)向及分支處均應裝置排管井坑(keng)(keng),長度超過30mm時也應加設(she)井坑(keng)(keng);
(3)井(jing)坑深度(du)不小于(yu)0.8m,人(ren)孔直(zhi)徑不小于(yu)0.7mm;
(4)排(pai)管應(ying)有(you)傾向井坑0.5%~1%的排(pai)水坡度。
64、對(dui)于電纜導(dao)體連(lian)接點的(de)電阻有何要求?
答(da):要求連接點的(de)電阻小而且(qie)穩(wen)定,連接點的(de)電阻與相(xiang)同長度、相(xiang)同截面的(de)導(dao)體之比(bi)值,對于(yu)新安裝的(de)終端(duan)頭(tou)和(he)中(zhong)(zhong)間頭(tou),應不(bu)(bu)大于(yu)1;對于(yu)運行中(zhong)(zhong)的(de)終端(duan)頭(tou)和(he)中(zhong)(zhong)間頭(tou)這個比(bi)值不(bu)(bu)應大于(yu)1.2。
65、電纜接頭和中間頭的(de)設(she)計應滿足哪些要求?
答(da):應滿足的要求有:
(1)耐壓強度(du)高,導體連接好;
(2)機(ji)械強度大,介質損失(shi)小;
(3)結構簡單(dan),密封性強。
66、什么(me)是(shi)電纜故障?有幾種常見的類型?
答:電(dian)纜(lan)故(gu)(gu)障是指電(dian)纜(lan)在(zai)預防性試(shi)驗(yan)時發(fa)生絕緣擊穿或在(zai)運行(xing)中,因絕緣擊穿、導線(xian)燒斷(duan)等而迫使電(dian)纜(lan)線(xian)路停(ting)電(dian)的故(gu)(gu)障。常見的故(gu)(gu)障有接地故(gu)(gu)障、短路故(gu)(gu)障、斷(duan)線(xian)故(gu)(gu)障、閃(shan)絡性故(gu)(gu)障和混合型故(gu)(gu)障等。
67、如何處理電纜線(xian)路的(de)單相接(jie)地故障?
答:電(dian)纜(lan)(lan)線路(lu)單相接(jie)(jie)地故(gu)障一般(ban)來說,電(dian)纜(lan)(lan)導(dao)體的(de)(de)損(sun)(sun)傷只是局部的(de)(de),如(ru)果屬于機械損(sun)(sun)傷,而故(gu)障點附(fu)近的(de)(de)土壤(rang)又(you)較干燥(zao)時,一般(ban)可(ke)進(jin)行局部修(xiu)理,加添一只假接(jie)(jie)頭,即不將(jiang)(jiang)電(dian)纜(lan)(lan)芯鋸斷,僅將(jiang)(jiang)故(gu)障點絕緣加強后密封即可(ke)。
68、電力電纜在敷設前應進(jin)行哪些(xie)試(shi)驗和檢查?
答:敷設前應檢查電(dian)(dian)纜的(de)型號、規格(ge)及(ji)長度是(shi)否符(fu)合要求,是(shi)否有外力損(sun)傷,低壓電(dian)(dian)纜用(yong)1000V兆歐(ou)表(biao)(biao)遙測絕緣電(dian)(dian)阻(zu),阻(zu)值一(yi)般不低于(yu)10MΩ,高壓電(dian)(dian)纜用(yong)2500V兆歐(ou)表(biao)(biao)搖測阻(zu)值一(yi)般不抵于(yu)400MΩ。
69、主廠房內(nei)敷設電(dian)纜時一般應注意什(shen)么?
答:在主廠房(fang)內敷(fu)設電纜時一般應注意:
(1)凡引至集控(kong)室的控(kong)制電纜宜架空敷設;
(2)6KV電纜宜(yi)用(yong)隧道或(huo)排管(guan)敷設,地下(xia)水(shui)位高處亦可架空或(huo)用(yong)排管(guan)敷設;
(3)380V電纜當(dang)(dang)兩端電纜在(zai)零(ling)米時(shi)宜(yi)用隧道(dao)、溝或排管,當(dang)(dang)一端設備在(zai)上、一端在(zai)下時(shi),可部分架(jia)空敷(fu)設,當(dang)(dang)地下水位(wei)較(jiao)高時(shi),宜(yi)架(jia)空。
70、電(dian)力電(dian)纜(lan)的內(nei)屏蔽層(ceng)與外屏蔽層(ceng)各在什(shen)么(me)部位?采用(yong)什(shen)么(me)材(cai)料?有何作用(yong)?
答:為了使(shi)(shi)絕(jue)(jue)緣(yuan)層(ceng)和電纜導(dao)體(ti)(ti)有(you)較好(hao)的(de)(de)(de)接觸,消除導(dao)體(ti)(ti)表面(mian)(mian)的(de)(de)(de)不光滑引起的(de)(de)(de)導(dao)體(ti)(ti)表面(mian)(mian)電場強度的(de)(de)(de)增(zeng)加,一般在導(dao)體(ti)(ti)表面(mian)(mian)包有(you)金(jin)屬(shu)化紙(zhi)或半導(dao)體(ti)(ti)紙(zhi)帶的(de)(de)(de)內(nei)屏蔽層(ceng)。為了使(shi)(shi)絕(jue)(jue)緣(yuan)層(ceng)和金(jin)屬(shu)護套(tao)有(you)較好(hao)的(de)(de)(de)接觸,一般在絕(jue)(jue)緣(yuan)層(ceng)外(wai)表面(mian)(mian)包有(you)外(wai)層(ceng)屏蔽層(ceng)。外(wai)屏層(ceng)與(yu)內(nei)屏層(ceng)的(de)(de)(de)材料(liao)相(xiang)同,有(you)時還外(wai)扎銅帶或編織銅絲帶。
71、簡述環氧樹脂復(fu)合(he)物(wu)的構成及性能。
答(da):環(huan)氧(yang)樹脂復合物由環(huan)氧(yang)樹脂加入(ru)硬(ying)化(hua)劑、填充劑增韌劑和稀釋劑組(zu)成。具有以下性能:
(1)有足夠的機(ji)械強度;
(2)電氣性能優良;
(3)電氣性能穩定;
(4)與有色(se)金屬有足夠的黏附力;
(5)耐腐蝕性好;
(6)戶外(wai)使用時,耐(nai)雨、耐(nai)光、耐(nai)濕(shi)熱。
72、單芯(xin)電纜(lan)護套(tao)一端接地方式中(zhong)為什么必須安裝(zhuang)一條沿電纜(lan)平行敷(fu)設的回流線(xian)?
答:在金屬(shu)護(hu)套一端接地(di)(di)的(de)(de)電(dian)(dian)纜(lan)線(xian)路中,為(wei)確(que)保護(hu)套中的(de)(de)感應(ying)電(dian)(dian)壓不(bu)超過(guo)允許標準(zhun),必須安(an)裝一條沿電(dian)(dian)纜(lan)線(xian)路平行(xing)敷設(she)的(de)(de)導(dao)體(ti),且導(dao)體(ti)的(de)(de)兩端接地(di)(di),這種導(dao)體(ti)稱為(wei)回流(liu)線(xian)。當發(fa)生單(dan)相接地(di)(di)故(gu)障時(shi),接地(di)(di)短路電(dian)(dian)流(liu)可以通過(guo)回流(liu)線(xian)流(liu)回系統(tong)中心點(dian),由(you)于通過(guo)回流(liu)線(xian)的(de)(de)接地(di)(di)電(dian)(dian)流(liu)產生的(de)(de)磁通抵消了一部分電(dian)(dian)纜(lan)導(dao)線(xian)接地(di)(di)電(dian)(dian)流(liu)所產生的(de)(de)磁通,因(yin)而(er)可降低(di)短路故(gu)障時(shi)護(hu)套的(de)(de)感應(ying)電(dian)(dian)壓。
73、電纜工程可劃分為幾個(ge)項目?
答(da):(1)工(gong)(gong)地(di)運輸(shu):包括工(gong)(gong)程材料(liao)從倉庫到施工(gong)(gong)點的(de)裝卸、運輸(shu)和空車回程。
(2)地方工程:包(bao)括路面開挖、隧、溝道施工等(deng)。
(3)敷(fu)設工程:包括敷(fu)設、中間頭制作(zuo)、掀蓋板、埋管、校潮、牽引頭制作(zuo)等。
(4)兩(liang)端(duan)工程:包括支、吊橋架和其基礎的制作(zuo)安裝(zhuang),終(zhong)端(duan)頭(tou)制作(zuo),油壓力(li)和信號(hao)裝(zhuang)置的安裝(zhuang),名種電氣性(xing)能(neng)測試等。
(5)塞(sai)止工程:包括(kuo)充油(you)電纜塞(sai)止頭(tou)制作,供油(you)箱、自動(dong)排水(shui)及信號(hao)裝置的(de)安(an)裝等。
(6)接(jie)地工程(cheng):包括絕(jue)緣接(jie)頭、換位箱、保護(hu)器、接(jie)地箱安裝等。
74、電纜線路的驗收(shou)應進行哪些(xie)檢查?
答:(1)電纜規格應(ying)符合(he)規定,排列應(ying)整齊,無(wu)損(sun)傷,標牌齊全、正(zheng)確(que)、清晰(xi);
(2)電(dian)纜(lan)的(de)固(gu)定(ding)彎曲半(ban)徑(jing)、有關距離及單芯電(dian)力電(dian)纜(lan)的(de)金屬護層的(de)接線應(ying)符合要求;
(3)電纜終(zhong)端、中間頭不滲漏油(you),安裝(zhuang)牢固,充油(you)電纜油(you)壓及表計(ji)整(zheng)定(ding)值應符(fu)合(he)要求(qiu);
(4)接(jie)地良好;
(5)電纜終(zhong)端相色正確,支架等的金屬部件油漆完(wan)整;
(6)電纜溝及隧道內、橋架上應無(wu)雜物,蓋板齊全。
75、電纜線(xian)路正序阻抗測量過程中(zhong)有什么要求?
答:電纜導體的交流電阻和電纜三(san)相同感抗的相量和稱為正序阻抗。
電纜(lan)線路的(de)正序(xu)阻抗(kang)一般可(ke)在電纜(lan)盤上(shang)(shang)直接(jie)測(ce)量(liang),測(ce)量(liang)時一般使用(yong)較低的(de)電壓,因此,需要用(yong)降(jiang)壓變壓器進行降(jiang)壓,降(jiang)壓器采用(yong)星形接(jie)線,容量(liang)一般為10kVA以上(shang)(shang),有較廣的(de)電壓調節范圍,測(ce)量(liang)時交流(liu)(liu)電源(yuan)應比(bi)較穩定,以保(bao)證測(ce)量(liang)時電流(liu)(liu)達(da)到規定的(de)要求,實際電壓表的(de)讀(du)數(shu)值必(bi)須(xu)是電纜(lan)端的(de)電壓,試驗電流(liu)(liu)更好 接(jie)近電纜(lan)長期允(yun)許載流(liu)(liu)量(liang),測(ce)讀(du)各表計的(de)數(shu)值時,合上(shang)(shang)電流(liu)(liu)后同時讀(du)取三個表的(de)數(shu)值。
76、根據《電業生(sheng)產安全規定》,電氣工作人(ren)員(yuan)必須具備(bei)的條件(jian)是(shi)什么?
答(da):必須具(ju)備(bei)下列條件:
(1)經醫生鑒定身體健(jian)康,無妨礙(ai)工作的(de)病癥;
(2)具(ju)備必要(yao)的電(dian)氣知(zhi)識,按其職務和工(gong)作性質(zhi)掌握相關的規(gui)程、專業技術及安全操作技術,并經(jing)考試(shi)合格;
(3)熟練掌握觸電急救(jiu)方法。
77、電(dian)纜在運輸裝卸(xie)過程中(zhong)應注意什么(me)?
答:(1)在(zai)運(yun)輸(shu)裝卸(xie)過(guo)程中,不應(ying)使電(dian)纜(lan)及電(dian)纜(lan)盤(pan)受(shou)到損傷,嚴(yan)禁將電(dian)纜(lan)盤(pan)直接由車上推下,電(dian)纜(lan)般不應(ying)平放運(yun)輸(shu),平放貯存。
(2)運輸或滾動(dong)電纜盤(pan)前,必須保證電纜盤(pan)牢固(gu)(gu)(gu),電纜繞緊、充(chong)油電纜至壓力(li)油箱間(jian)的油管應固(gu)(gu)(gu)定,不得損傷,壓力(li)油箱應牢固(gu)(gu)(gu),壓力(li)指示應符合要求。
78、電纜防火(huo)有哪(na)些措施(shi)?
答:(1)采用阻燃電纜;
(2)采用防火電纜托架;
(3)采用防(fang)火涂料;
(4)電纜(lan)隧道、夾層出口等(deng)處設置防火(huo)隔墻、防火(huo)擋板(ban);
(5)架空電纜應避(bi)開油管道、防爆門,否則應有要取局(ju)部穿管或隔(ge)熱防火措施。
79、選擇電力電纜的截面應(ying)從哪幾個(ge)方面考(kao)慮?
答(da):應考(kao)慮如下幾個方(fang)面:
(1)電纜(lan)長期(qi)允許通過的工作電流;
(2)一旦短路時的(de)熱穩定性;
(3)線(xian)路(lu)上的電壓降不(bu)能超(chao)出允(yun)許工(gong)作(zuo)范圍。
80、電力電纜和架空線比(bi)較有哪些(xie)優點?
答(da):(1)運行可靠,由于安裝在地下等隱蔽(bi)處,受外(wai)力破(po)壞小,發生故障(zhang)的機會較(jiao)少,供電安全,不會給人身造(zao)成危害;
(2)維護工作量小(xiao),不需頻繁的巡檢;
(3)不需架設(she)桿(gan)塔;
(4)有助于提高功(gong)率因數。