国产精品成人网站/两攻一受3p双龙h调教/玩弄人妻少妇500系列/人妻换人妻仑乱/国产成人一区二区三区别

中文

全國熱線:138-9810-2027

推薦資訊

全國服務熱線

138-9810-2027

綏中電線電纜常識80問答?沈陽凱鵬電纜廠提供

來源:常(chang)見問(wen)題 閱(yue)讀:157048 發布(bu)時間(jian):2023-03-07

1、常用的電線、電纜按用途分有哪些種類(lei)?

答:按用途(tu)可分為裸導線、絕(jue)緣電線、耐熱(re)電線、屏蔽電線、電力電纜、控(kong)制電纜、通信電纜、射頻電纜等。


2、絕(jue)緣電(dian)線有哪幾種?

答(da):常有的絕(jue)(jue)(jue)(jue)緣(yuan)(yuan)電(dian)(dian)(dian)線(xian)有以下(xia)幾(ji)種(zhong):聚(ju)氯(lv)(lv)乙烯絕(jue)(jue)(jue)(jue)緣(yuan)(yuan)電(dian)(dian)(dian)線(xian)、聚(ju)氯(lv)(lv)乙烯絕(jue)(jue)(jue)(jue)緣(yuan)(yuan)軟線(xian)、丁腈(jing)聚(ju)氯(lv)(lv)乙烯混合物絕(jue)(jue)(jue)(jue)緣(yuan)(yuan)軟線(xian)、橡皮絕(jue)(jue)(jue)(jue)緣(yuan)(yuan)電(dian)(dian)(dian)線(xian)、農用地下(xia)直埋(mai)鋁芯塑料絕(jue)(jue)(jue)(jue)緣(yuan)(yuan)電(dian)(dian)(dian)線(xian)、橡皮絕(jue)(jue)(jue)(jue)緣(yuan)(yuan)棉紗紡織軟線(xian)、聚(ju)氯(lv)(lv)乙烯絕(jue)(jue)(jue)(jue)緣(yuan)(yuan)尼龍(long)護套電(dian)(dian)(dian)線(xian)、電(dian)(dian)(dian)力和照明用聚(ju)氯(lv)(lv)乙烯絕(jue)(jue)(jue)(jue)緣(yuan)(yuan)軟線(xian)等。


3、電(dian)纜(lan)橋(qiao)架適合(he)于何種場合(he)?

答:電(dian)纜橋架(jia)適用(yong)于一般(ban)工礦(kuang)企(qi)業室(shi)內外架(jia)空(kong)敷設(she)電(dian)力電(dian)纜、控制電(dian)纜,亦可用(yong)于電(dian)信、廣播電(dian)視等部(bu)門在室(shi)內外架(jia)設(she)。


4、電纜(lan)附件有哪些?

答:常用(yong)的電附件有(you)電纜終端接線(xian)盒、電纜中間接線(xian)盒、連(lian)接管及接線(xian)端子、鋼板接線(xian)槽、電纜橋架等(deng)。


5、什么叫電纜中(zhong)間(jian)接(jie)頭?

答:連(lian)接電(dian)(dian)纜與電(dian)(dian)纜的導(dao)體、絕(jue)緣屏(ping)蔽層(ceng)(ceng)和(he)保護層(ceng)(ceng),以使電(dian)(dian)纜線路連(lian)接的裝置,稱為電(dian)(dian)纜中間接頭。


6、什(shen)么叫電氣主接線?

答:電(dian)(dian)氣主接線(xian)是發(fa)電(dian)(dian)廠、變電(dian)(dian)所中(zhong)主要(yao)電(dian)(dian)氣設備和(he)母線(xian)的連接方(fang)式,包括主母線(xian)和(he)廠用電(dian)(dian)系統按一定(ding)的功能(neng)要(yao)求的連接方(fang)式。


7、在選擇電力電纜(lan)的截面(mian)時,應(ying)遵照哪些規定?

答:電(dian)力(li)電(dian)纜的(de)選擇應遵(zun)照以(yi)下原則:(1)電(dian)纜的(de)額定(ding)電(dian)壓要大(da)于或等于安裝(zhuang)點供(gong)(gong)電(dian)系統的(de)額定(ding)電(dian)壓;(2)電(dian)纜持續容許電(dian)流(liu)(liu)應等于或大(da)于供(gong)(gong)電(dian)負載的(de)更大(da) 持續電(dian)流(liu)(liu);(3)線芯(xin)截(jie)面(mian)要滿足供(gong)(gong)電(dian)系統短路(lu)時(shi)的(de)穩(wen)定(ding)性(xing)的(de)要求(qiu);(4)根據電(dian)纜長度驗算電(dian)壓降是否符合要求(qiu);(5)線路(lu)末端的(de)最(zui)小短路(lu)電(dian)流(liu)(liu)應能(neng)使(shi)保護裝(zhuang)置(zhi)可(ke)靠的(de)動作。


8、交聯聚乙(yi)烯(xi)電(dian)纜(lan)和(he)油紙電(dian)纜(lan)比較有哪些優點?

答:(1)易安裝,因為(wei)它允許(xu)最(zui)小彎曲(qu)半徑小、且重量輕;(2)不受線路落(luo)差*;(3)熱性能好,允許(xu)工作(zuo)溫度高(gao)、傳輸容量大;(4)電纜附件簡(jian)單,均為(wei)干式結(jie)構;(5)運行維護簡(jian)單,無漏油問題;(6)價格較低;(7)可(ke)靠性高(gao)、故障率(lv)低;(8)制造工序(xu)少、工藝(yi)簡(jian)單,經(jing)濟效益顯著。


9、固(gu)定交流單(dan)芯(xin)電纜的夾具有(you)什么要求?為什么?

答:夾(jia)具應無鐵件(jian)構成閉合磁路(lu),這是因為當(dang)電(dian)纜線(xian)(xian)芯通(tong)過電(dian)流(liu)時,在其周(zhou)圍產生磁力(li)(li)線(xian)(xian),磁力(li)(li)線(xian)(xian)與通(tong)過線(xian)(xian)芯的電(dian)流(liu)大小成正(zheng)比,若使(shi)用鐵件(jian)等導磁材料,根據電(dian)磁感應可知,將(jiang)在鐵件(jian)中產生渦流(liu)使(shi)電(dian)纜發熱,甚至燒(shao)壞電(dian)纜。所以不(bu)可使(shi)用鐵件(jian)作單芯交流(liu)電(dian)纜的固定(ding)夾(jia)具。


10、以下的(de)(de)熱縮(suo)電纜(lan)頭的(de)(de)附件的(de)(de)更大(da) 特點和優點是什么?

答:熱縮(suo)(suo)附(fu)(fu)件的(de)更大 特點是用應力管代替傳統的(de)應力錐(zhui),它(ta)不僅(jin)簡化了施工(gong)工(gong)藝,還縮(suo)(suo)小了接頭的(de)終端(duan)的(de)尺寸,安裝方便,省時省工(gong),性能優越(yue),節(jie)約(yue)金屬(shu)。熱縮(suo)(suo)電纜(lan)附(fu)(fu)件集(ji)灌注式(shi)和干包式(shi)為一(yi)體,集(ji)合了這兩種附(fu)(fu)件的(de)優點。


11、電纜敷設前應進行哪些檢查工作?

答:(1)支(zhi)架應(ying)齊全、油(you)(you)漆完整。(2)電(dian)(dian)(dian)纜型號(hao)、電(dian)(dian)(dian)壓(ya)、規(gui)格(ge)符合設(she)計(ji)。(3)電(dian)(dian)(dian)纜絕緣良(liang)好,當(dang)對油(you)(you)紙電(dian)(dian)(dian)纜的(de)密(mi)封有懷疑時(shi),應(ying)進行受潮判(pan)斷;直埋電(dian)(dian)(dian)纜與小底電(dian)(dian)(dian)纜應(ying)經(jing)直流耐壓(ya)試難合格(ge);充油(you)(you)電(dian)(dian)(dian)纜的(de)油(you)(you)樣應(ying)試驗合格(ge)。(4)充油(you)(you)電(dian)(dian)(dian)纜的(de)油(you)(you)壓(ya)不宜低(di)于(yu)1.47MPa。


11、交聯(lian)熱收縮電(dian)纜附(fu)件有哪些優(you)點?

答:這是一種新型材料,它(ta)與現在其他類型附件比較具(ju)有電氣性(xing)能優(you)越、體積小、質量小、安(an)裝簡便、材料配套等(deng)(deng)優(you)點,另外還具(ju)有耐(nai)氣候(hou)、抗污(wu)穢性(xing)、阻燃自熄等(deng)(deng)能力。


12、對油紙(zhi)絕緣(yuan)電(dian)力(li)電(dian)纜密封(feng)有懷疑時,如何用較簡單(dan)的辦(ban)法檢查(cha)電(dian)纜絕緣(yuan)紙(zhi)是否受潮?

答:把電(dian)纜(lan)絕(jue)緣(yuan)紙點燃或放入150℃左右的電(dian)纜(lan)油(you)中檢查,無“嘶嘶”聲或白(bai)色泡(pao)沫出現,說明(ming)未受潮。


13、電纜標志牌(pai)應注明(ming)什么內容?編(bian)寫有(you)何要(yao)求?

答:標志牌上應注明電(dian)纜線路設計編號、電(dian)纜型號、規格及始(shi)點,并聯使(shi)用(yong)的電(dian)纜應有順(shun)序(xu)號。要求字跡清晰(xi)、不(bu)易脫落(luo)。


14、直埋電(dian)纜的方(fang)位標志應設置在(zai)哪些位置?

答:在電(dian)纜兩端,電(dian)纜直線(xian)段(duan)50~100m處(chu)電(dian)纜接頭幾(ji)電(dian)纜改變方(fang)向(xiang)的(de)彎(wan)角處(chu)。


15、制作電纜接頭用的黃(huang)臘綢(chou)帶(dai)、黑玻璃(li)漆帶(dai)、無堿玻璃(li)絲帶(dai)等,施(shi)工前如何進(jin)行排潮處理?

答(da):(1)恒溫干(gan)燥法:將絕緣(yuan)帶卷(juan)成(cheng)直徑為25~30mm小(xiao)卷(juan),放(fang)入110~120℃恒溫干(gan)燥箱(xiang)內烘4~5h,冷(leng)卻干(gan)取(qu)出,放(fang)入干(gan)燥的(de)密封(feng)筒內。(2)油(you)浸排潮法:將絕緣(yuan)帶小(xiao)卷(juan)放(fang)入恒溫在120~130℃的(de)電纜油(you)中(zhong)(zhong),離鍋底保持(chi)30mm距離,經一定時間(jian)后油(you)面不(bu)再(zai)產生泡沫(mo)后取(qu)出,裝入貯有(you)電纜油(you)的(de)桶中(zhong)(zhong),油(you)位應超過所有(you)裝入的(de)物體并將其(qi)密封(feng)。


16、電纜外護層的作(zuo)用(yong)是什么?

答(da):保(bao)護內護層不(bu)受機械損傷和化學腐蝕,增強機械強度。


17、室外電纜溝應符合哪些要求?

答:電纜(lan)溝(gou)上部應比地面稍(shao)高,加(jia)蓋用(yong)混凝土制作的蓋板,電纜(lan)應平(ping)敷在支架上,有良(liang)好的排水管。


18、電纜(lan)內護(hu)層的作用是什么(me)?

答;使絕緣層不會與水、空氣或其他物體(ti)接觸,防止絕緣受(shou)潮和絕緣層不受(shou)機(ji)械傷(shang)害。


19、使用鋼絲鉗(qian)時(shi)應(ying)注意(yi)些(xie)什么?

答:使(shi)用(yong)前,一定(ding)要(yao)檢查絕(jue)緣柄的絕(jue)緣是否完好(hao)無損(sun),使(shi)用(yong)時(shi)不可用(yong)鋼(gang)絲(si)鉗剪切超過(guo)規格所(suo)允(yun)許的金屬線材,并禁止(zhi)用(yong)鋼(gang)絲(si)鉗代替錘子(zi)敲打工具,以免損(sun)壞。


20、什(shen)么叫絕緣強度?

答:絕緣(yuan)(yuan)物質在電(dian)場(chang)中,當電(dian)場(chang)強度增大(da)到(dao)某一極(ji)限(xian)時就會(hui)被擊(ji)穿,這(zhe)個導致絕緣(yuan)(yuan)擊(ji)穿的(de)電(dian)場(chang)強度稱為(wei)絕緣(yuan)(yuan)強度。


22、對電(dian)纜導體連(lian)接點的機械(xie)強(qiang)度有何(he)要求?

答:連接點(dian)的(de)機械(xie)強度,一般低于(yu)電(dian)纜(lan)導體(ti)本身的(de)抗(kang)拉強度,對(dui)于(yu)固定敷(fu)設(she)的(de)電(dian)力電(dian)纜(lan),其連接點(dian)的(de)抗(kang)拉強度要求(qiu)不低于(yu)導體(ti)本身抗(kang)拉強度的(de)60%。


23、電(dian)力電(dian)纜的絕緣層材料應具備哪(na)些主(zhu)要性能?

答(da);應具備下列主要性(xing)(xing)(xing)(xing)能(neng):(1)高(gao)的(de)擊穿強(qiang)度;(2)低的(de)介質(zhi)損耗;(3)相當(dang)高(gao)的(de)絕(jue)緣電(dian)阻(zu);(4)優良的(de)耐放(fang)電(dian)性(xing)(xing)(xing)(xing)能(neng);(5)具有一定的(de)柔軟性(xing)(xing)(xing)(xing)和機械強(qiang)度;(6)絕(jue)緣性(xing)(xing)(xing)(xing)能(neng)長期穩定。


24、機械敷設電纜時,牽引強度(du)有何規定?

答:對于(yu)銅芯電(dian)(dian)纜,當牽(qian)引(yin)頭部時(shi)(shi),允(yun)許(xu)牽(qian)引(yin)強(qiang)(qiang)度為(wei)70N/cm;對于(yu)鋁芯電(dian)(dian)纜,當牽(qian)引(yin)頭部時(shi)(shi),允(yun)許(xu)牽(qian)引(yin)強(qiang)(qiang)度為(wei)40N/cm;若利用鋼絲網套牽(qian)引(yin)時(shi)(shi),鉛(qian)護(hu)套電(dian)(dian)纜允(yun)許(xu)強(qiang)(qiang)度為(wei)10N/cm;鉛(qian)護(hu)套電(dian)(dian)纜為(wei)40N/cm。


25、對電(dian)纜保護(hu)管有何規定?

答:(1)電纜需要穿(chuan)保護管敷設時,管子內(nei)徑不應(ying)小于(yu)電纜外徑的(de)1.5倍,混(hun)凝土(tu)管、陶土(tu)管、石(shi)棉、水泥管的(de)內(nei)徑不應(ying)小于(yu)100mm;

(2)電纜(lan)管(guan)的彎曲(qu)半徑(jing)應(ying)符合所穿入電纜(lan)彎曲(qu)半徑(jing)的規定;

(3)每根管子最多(duo)不應超過三(san)個彎頭(tou),直角彎不應多(duo)于2個。

26、如何測量電纜護套的外徑?

答:在護套圓周上均勻(yun)分布的(de)(de)五點(dian)處,測量護套外(wai)徑(jing)和其平均值,其平均外(wai)徑(jing)既為護套的(de)(de)外(wai)徑(jing)。

27、不同截(jie)面的銅芯電纜如何連接?

答:不(bu)同(tong)(tong)截面(mian)的銅芯電纜連(lian)接(jie),可采用(yong)開口弱背銅接(jie)管,以錫(xi)焊(han)法(fa)連(lian)接(jie),也可用(yong)純銅棒按(an)不(bu)同(tong)(tong)的截面(mian)要求(qiu)連(lian)接(jie)成銅接(jie)管,以壓接(jie)法(fa)連(lian)接(jie)。

28、簡(jian)述(shu)10KV交(jiao)聯電纜熱縮式制作(zuo)戶內終端頭的(de)過程?

答;(1)準備(bei)階段(duan):檢(jian)(jian)查熱縮電纜附件是(shi)否齊備(bei),型(xing)號(hao)是(shi)否相配(pei),檢(jian)(jian)查并確認電纜有無潮(chao)氣后,檢(jian)(jian)查電纜。

(2)切除多余電纜(lan),根(gen)據現場情況決(jue)定電纜(lan)長度。

(3)剝除護層。

(4)焊(han)接(jie)(jie)接(jie)(jie)地(di)線(xian),將(jiang)接(jie)(jie)地(di)線(xian)焊(han)接(jie)(jie)在鋼(gang)帶上。

(5)填充三(san)叉口及繞包密(mi)封(feng)膠(jiao)。

(6)安裝三芯分支護(hu)套,將護(hu)套套入根(gen)部,從中部開始收縮,先往(wang)根(gen)部,再往(wang)指(zhi)部。

(7)剝銅(tong) 帶和外半導電層(ceng),剝切三芯分(fen)支套(tao)口20mm以上的銅(tong)帶,嚴禁(jin)損傷主(zhu)絕緣,清(qing)除干凈半導電層(ceng)。

(8)安裝應(ying)力(li)管,管口端部分(fen)支(zhi)套(tao)對(dui)接后熱縮。

(9)安裝接線端子。

(10)安裝絕緣(yuan)管。

(11)安裝密封(feng)管。

(12)核相后安裝相色(se)管。

29、戶內、戶外預制(zhi)式終(zhong)端安裝步驟有哪(na)些(xie)?

答:(1) 將電(dian)纜按預定(ding)位置(zhi)就位、固定(ding)、清潔表面,參(can)照說明書剝除(chu)外(wai)護套,如有特殊(shu)需要(yao),外(wai)護套剝切長(chang)度可調整,分別由銅(tong)帶(dai)、外(wai)護套鎧裝引出2組地線。

(2) 由外護套口(kou)向(xiang)上量取需要尺寸(cun),切除多余(yu)電纜,套入熱縮(suo)三指套至三叉口(kou)根部由中(zhong)間加熱收縮(suo),由指套上口(kou)向(xiang)上量取規(gui)定尺寸(cun)(35kv為350~380mm)。去(qu)掉(diao)多余(yu)銅(tong)帶(保留20mm),再保留半導(dao)體預定位置,壓接(jie)出線端子密封。

30、電(dian)線電(dian)纜的(de)應用主要(yao)分為三大類 :

(1)、電力系(xi)統

電(dian)(dian)(dian)力系統采用(yong)的電(dian)(dian)(dian)線(xian)(xian)(xian)電(dian)(dian)(dian)纜(lan)產品(pin)主要有架(jia)(jia)空裸電(dian)(dian)(dian)線(xian)(xian)(xian)、匯流排(母(mu)線(xian)(xian)(xian))、電(dian)(dian)(dian)力電(dian)(dian)(dian)纜(lan)(塑料(liao)線(xian)(xian)(xian)纜(lan)、油紙力纜(lan)(基本被塑料(liao)電(dian)(dian)(dian)力電(dian)(dian)(dian)纜(lan)代替)、橡(xiang)套線(xian)(xian)(xian)纜(lan)、架(jia)(jia)空絕緣電(dian)(dian)(dian)纜(lan))、分支電(dian)(dian)(dian)纜(lan)(取代部(bu)分母(mu)線(xian)(xian)(xian))、電(dian)(dian)(dian)磁線(xian)(xian)(xian)以及電(dian)(dian)(dian)力設備用(yong)電(dian)(dian)(dian)氣裝備電(dian)(dian)(dian)線(xian)(xian)(xian)電(dian)(dian)(dian)纜(lan)等(deng)。

(2)、信(xin)息傳輸系統

用于(yu)信(xin)息傳(chuan)輸系統的電(dian)(dian)線(xian)電(dian)(dian)纜(lan)(lan)主要有市話(hua)電(dian)(dian)纜(lan)(lan)、電(dian)(dian)視電(dian)(dian)纜(lan)(lan)、電(dian)(dian)子線(xian)纜(lan)(lan)、射頻電(dian)(dian)纜(lan)(lan)、光纖纜(lan)(lan)、數據電(dian)(dian)纜(lan)(lan)、電(dian)(dian)磁(ci)線(xian)、電(dian)(dian)力通訊或其他復合電(dian)(dian)纜(lan)(lan)等。

(3)、機(ji)械設備、儀(yi)(yi)器儀(yi)(yi)表系統

此(ci)部(bu)分除架空裸電(dian)線外(wai)幾乎其他(ta)所有(you)產(chan)品均(jun)有(you)應用,但主(zhu)要是電(dian)力電(dian)纜(lan)、電(dian)磁(ci)線、數據(ju)電(dian)纜(lan)、儀器儀表線纜(lan)等。

31、電線(xian)電纜產品主要分為五(wu)大類(lei):

(1)、裸電線(xian)及(ji)裸導(dao)(dao)體制品 本類產品的主要(yao)特征(zheng)是:純的導(dao)(dao)體金屬(shu),無絕緣及(ji)護(hu)套層(ceng),如鋼(gang)芯鋁絞線(xian)、銅鋁匯流排、電力(li)機車線(xian)等;加工(gong)工(gong)藝主要(yao)是壓力(li)加工(gong),如熔煉、壓延、拉制、絞合(he)/緊壓絞合(he)等;產品主要(yao)用在(zai)城郊(jiao)、農村、用戶主線(xian)、開關柜(ju)等。

(2)、電力電纜(lan)(lan)本類產品主要(yao)特征(zheng)是:在導體外擠(繞)包絕(jue)緣(yuan)層,如架空絕(jue)緣(yuan)電纜(lan)(lan),或幾芯(xin)絞合(對應電力系(xi)統的相(xiang)線、零線和地(di)線),如二芯(xin)以上(shang)架空絕(jue)緣(yuan)電纜(lan)(lan),或再增加護套(tao)(tao)層,如塑料/橡套(tao)(tao)電線電纜(lan)(lan)。主要(yao)的工藝技術(shu)有(you)(you)拉制、絞合、絕(jue)緣(yuan)擠出(繞包)、成(cheng)纜(lan)(lan)、鎧(kai)裝、護層擠出等,各種產品的不同工序組合有(you)(you)一定(ding)區(qu)別。

產品主要用在發、配、輸、變(bian)、供電(dian)線路(lu)中的(de)強(qiang)電(dian)電(dian)能傳輸,通過的(de)電(dian)流大(幾十安至幾千安)、電(dian)壓(ya)高(220V至500kV及以上)。

(3)、電氣裝備用(yong)電線電纜(lan)(lan)(lan)該類產品(pin)主要特征是:品(pin)種規格繁多,應用(yong)范(fan)圍(wei)廣泛,使用(yong)電壓在1kV及以下較多,面對特殊場合(he)不斷衍生新的產品(pin),如(ru)耐(nai)火線纜(lan)(lan)(lan)、阻(zu)燃線纜(lan)(lan)(lan)、低煙(yan)無鹵/低煙(yan)低鹵線纜(lan)(lan)(lan)、防白蟻、防老(lao)鼠線纜(lan)(lan)(lan)、耐(nai)油/耐(nai)寒(han)/耐(nai)溫/耐(nai)磨線纜(lan)(lan)(lan)、醫用(yong)/農用(yong)/礦用(yong)線纜(lan)(lan)(lan)、薄壁電線等。

(4)、通訊電(dian)纜(lan)(lan)及光(guang)纖(簡(jian)略(lve)介(jie)紹)隨(sui)著(zhu)近二十多年來,通訊行業(ye)的飛速(su)發展(zhan)(zhan),產品(pin)也有驚人的發展(zhan)(zhan)速(su)度。從過去的簡(jian)單的電(dian)話電(dian)報(bao)線纜(lan)(lan)發展(zhan)(zhan)到幾(ji)千對的話纜(lan)(lan)、同軸纜(lan)(lan)、光(guang)纜(lan)(lan)、數據電(dian)纜(lan)(lan),甚至組合(he)通訊纜(lan)(lan)等。

該(gai)類(lei)產(chan)品結構(gou)尺寸通(tong)常較小而(er)均勻,制造精度(du)要求高。

(5)、電磁線(xian)(繞組線(xian))主要(yao)用于各種電機、儀(yi)器儀(yi)表(biao)等。

電(dian)線(xian)電(dian)纜的衍生/新產(chan)品

電線電纜的(de)(de)衍生/新產品主(zhu)要是因應用(yong)場合、應用(yong)要求不同及裝(zhuang)備的(de)(de)方便性和降低裝(zhuang)備成本等的(de)(de)要求,而采用(yong)新材料、特(te)殊材料、或改(gai)變產品結構、或提高工藝要求、或將不同品種的(de)(de)產品進行組(zu)合而產生。

采用不同材料如(ru)阻燃線(xian)纜、低煙無鹵/低煙低鹵線(xian)纜、防(fang)白蟻、防(fang)老鼠線(xian)纜、耐(nai)油/耐(nai)寒/耐(nai)溫線(xian)纜等;

改(gai)變產品結構(gou)如:耐(nai)火電纜等;

提高工藝(yi)要求(qiu)如:醫用線(xian)纜等;

組合產品如:OPGW等;

方便安(an)裝(zhuang)和降低裝(zhuang)備成本如:預(yu)制分支電纜(lan)等(deng)。

32、母(mu)線裝置施工完(wan),應進行哪些檢查?

答:應進行下列檢查(cha):

(1)金屬構件的加工(gong)、配制、焊(han)接螺接應符(fu)合規定;

(2)各(ge)部螺栓、墊圈(quan)、開口銷(xiao)等零部件(jian)應齊全可靠;

(3)母(mu)線配制及安裝架(jia)應(ying)符合(he)規定,相間及對(dui)地電氣距離符合(he)要求;

(4)瓷(ci)件、鐵件及(ji)膠合處應完整(zheng),充油(you)套(tao)管應無(wu)滲油(you),油(you)位(wei)正(zheng)常;

(5)油漆(qi)完(wan)整,相色正確(que),接地良好。

33、在35kv及以下電力電纜接(jie)頭(tou)中,改善其(qi)護套(tao)斷開處電場分布的方(fang)法有幾種(zhong)(請(qing)列(lie)出五(wu)種(zhong)),并簡述其(qi)方(fang)法。

答:(1)脹喇叭口:在鉛(qian)包割斷(duan)處(chu)把鉛(qian)包邊緣撬起(qi),成(cheng)喇叭狀,其邊緣應(ying)光滑、圓整(zheng)、對稱。

(2)預留(liu)統包絕緣:在鉛包切口(kou)至電纜芯線(xian)分開點之間留(liu)有一段(duan)統包絕緣紙。

(3)切除(chu)半(ban)導電紙(zhi):將半(ban)導電紙(zhi)切除(chu)到喇叭(ba)口以下。

(4)包(bao)(bao)繞應(ying)力(li)錐:用絕緣(yuan)包(bao)(bao)帶和導電(dian)金(jin)屬(shu)材料包(bao)(bao)成錐形(xing),人為地將屏蔽層擴大,以(yi)改善電(dian)場分布。

(5)等電位法:對于干(gan)包型或交聯聚乙烯電纜(lan)頭,在各線芯概(gai)況絕緣表面上包一段金屬帶,并將其連接在一起(qi)。

(6)裝設應力(li)控制管:對于(yu)35kv及發下熱縮管電纜頭,首先(xian)從線(xian)芯銅屏蔽(bi)層末(mo)端方(fang)向經(jing)半(ban)導(dao)體(ti)帶至線(xian)芯絕緣(yuan)概況包繞2層半(ban)導(dao)體(ti)帶,然后將相應規(gui)格(ge)折應力(li)管,套在銅屏蔽(bi)的(de)末(mo)端處,熱縮成形。

34、電纜支架(jia)的加(jia)工應(ying)符合哪些要求(qiu)?

答:(1)鋼材應(ying)平直,無明顯扭曲,下料誤差應(ying)在(zai)5mm范圍內(nei),切(qie)口應(ying)無卷邊,毛剌;

(2)支架(jia)應(ying)(ying)焊接牢固(gu),無顯蓍變形,各橫撐間(jian)的垂直凈距與設計偏差(cha)不應(ying)(ying)大于(yu)5mm;

(3)金屬支架必(bi)須進(jin)行防腐(fu)處理,位(wei)于濕熱(re)、鹽、霧以及有化學腐(fu)蝕地區(qu)時,應根據設計作特殊的防腐(fu)處理。

35、列舉出你熟(shu)悉的電(dian)纜架。

答:拼焊式(shi)E型(xing)架(jia)、裝配式(shi)E型(xing)架(jia)、橋式(shi)電(dian)纜(lan)架(jia)、電(dian)纜(lan)托架(jia)、掛鉤式(shi)支(zhi)(zhi)架(jia)、單根電(dian)纜(lan)支(zhi)(zhi)架(jia)等(deng)。

36、敷(fu)設電(dian)纜(lan)應(ying)滿足哪(na)些要求?

答(da):應滿(man)足以(yi)下要求:

(1)安全運行方面(mian),盡(jin)可能避免各種外來損壞,提高電纜線(xian)路的(de)供電可靠性(xing);

(2)經濟方(fang)(fang)面(mian),從(cong)投資最省的方(fang)(fang)面(mian)考慮;

(3)施工方面,電纜線(xian)路的路徑(jing)必須便于旋工和投(tou)運后的維修。

37、制作電(dian)纜終端頭(tou)或中間接頭(tou)的絕(jue)緣材料(liao)有(you)哪(na)些?

答:有絕(jue)緣(yuan)膠、絕(jue)緣(yuan)帶、絕(jue)緣(yuan)管、絕(jue)緣(yuan)手(shou)套、絕(jue)緣(yuan)樹脂等。

38、簡述電(dian)(dian)纜頭制(zhi)(zhi)作的一般(ban)操作程序(xu)。答:(1)制(zhi)(zhi)作前的準備:包(bao)括○1閱讀安(an)裝說(shuo)明書;○2察看(kan)現場;○3備料;○4電(dian)(dian)纜試(shi)潮;○5制(zhi)(zhi)作前測試(shi)等。

(2)接頭的制作過程:包括(kuo)○1割斷多余電纜;○2電纜保護層的剝切(qie);○3導(dao)體連(lian)接;○4包繞絕(jue)緣(或收縮管材(cai));○5安裝接頭外(wai)殼(ke);○6灌注絕(jue)緣劑;○7進行密封(feng)處(chu)理等。

(3)制作后(hou)電氣測試。

39、電纜保(bao)護(hu)管(guan)的(de)加工應符合哪些要求?

答:(1)管(guan)口應*剌和尖(jian)銳(rui)楞角,管(guan)口宜做成(cheng)喇叭形。

(2)電纜(lan)管在彎制后(hou),不應有(you)裂縫(feng)和顯著的(de)(de)凹(ao)癟現象,其彎扁程(cheng)度不宜大于管子外徑(jing)10%;電纜(lan)管的(de)(de)彎曲(qu)半徑(jing)不應小于所穿(chuan)入電纜(lan)的(de)(de)最小允(yun)許彎曲(qu)半徑(jing)。

(3)金屬管應(ying)在外表(biao)涂(tu)防腐漆或瀝表(biao),鍍鋅(xin)管鋅(xin)層剝(bo)落(luo)處也應(ying)涂(tu)以防腐漆。

40、電纜的(de)排列符(fu)合(he)哪些要求?答(da):(1)電力(li)電纜和控纜不(bu)應配置在同一層支(zhi)架上。

(2)高、低壓電(dian)(dian)纜(lan)(lan),強、弱電(dian)(dian)控纜(lan)(lan)應按須序分層配(pei)置(zhi),一般情況宜由上(shang)而下,但在含有35kv以上(shang)高壓電(dian)(dian)纜(lan)(lan)引入柜盤時,為(wei)滿足彎曲半(ban)徑,可由下面上(shang)配(pei)置(zhi)。

41、電纜(lan)溝內敷(fu)設電纜(lan)的方(fang)法(fa)是(shi)什么?

答(da):在(zai)電(dian)(dian)(dian)(dian)纜(lan)(lan)(lan)溝(gou)內敷設(she)電(dian)(dian)(dian)(dian)纜(lan)(lan)(lan)的方(fang)法(fa)與(yu)直埋電(dian)(dian)(dian)(dian)纜(lan)(lan)(lan)的敷設(she)方(fang)法(fa)相仿,一般可(ke)將滑輪放在(zai)溝(gou)內,施放完畢,將電(dian)(dian)(dian)(dian)纜(lan)(lan)(lan)放于溝(gou)底或(huo)支架上,并(bing)在(zai)電(dian)(dian)(dian)(dian)纜(lan)(lan)(lan)上綁扎電(dian)(dian)(dian)(dian)纜(lan)(lan)(lan)標(biao)牌(pai)。

42、電纜(lan)敷設(she)的常用設(she)備有哪些(xie)?

答:(1)空氣壓縮機,主要(yao)用來破(po)壞(huai)路面,為以后敷設電纜(lan)作準(zhun)備;

(2)電(dian)動卷揚機或電(dian)纜牽(qian)引機,主(zhu)要用來拖電(dian)纜;

(3)電(dian)(dian)纜(lan)輸(shu)送(song)機,配合(he)牽引機使用來克(ke)服巨大(da)的(de)摩擦力,減輕對電(dian)(dian)纜(lan)的(de)損壞(huai);

(4)電(dian)纜(lan)盤放線支架(jia);

(5)滾(gun)輪裝置;

(6)防捻(nian) ,減鋼絲繩出現的扭曲;

(7)電纜盤制動裝置;

(8)張(zhang)力計(ji)。

43、電(dian)纜(lan)溝中支架安裝距離的(de)(de)要求(qiu)如何?答:電(dian)纜(lan)固(gu)定于(yu)(yu)電(dian)纜(lan)溝和隧(sui)道的(de)(de)墻(qiang)上,水平裝置(zhi)時,當電(dian)纜(lan)外(wai)(wai)徑等于(yu)(yu)或小(xiao)于(yu)(yu)50mm時應每(mei)隔(ge)1m加(jia)一支撐;外(wai)(wai)徑大于(yu)(yu)50mm的(de)(de)電(dian)纜(lan)每(mei)隔(ge)0.6m加(jia)一支撐;排成三(san)角(jiao)形(xing)的(de)(de)單(dan)電(dian)纜(lan),每(mei)隔(ge)1m應用綁帶扎牢,垂(chui)直裝置(zhi)時,每(mei)隔(ge)1~1.5m加(jia)以固(gu)定。

44、如何處(chu)理電(dian)力電(dian)纜與控制電(dian)纜在同(tong)一托架(jia)的安裝?

答(da):電力電纜(lan)(lan)(lan)與(yu)控(kong)制電纜(lan)(lan)(lan)一(yi)般不應敷設(she)在同(tong)一(yi)托(tuo)架(jia)內,當電纜(lan)(lan)(lan)較少而將控(kong)纜(lan)(lan)(lan)與(yu)電力電纜(lan)(lan)(lan)敷設(she)在同(tong)一(yi)托(tuo)架(jia)內時,應用隔板隔開(kai)。

45、電纜隧道內(nei)如何裝設接地(di)線?

答:隧道和(he)溝(gou)的(de)(de)全長應(ying)(ying)裝(zhuang)設連(lian)(lian)續的(de)(de)接(jie)(jie)(jie)地(di)線,接(jie)(jie)(jie)地(di)線應(ying)(ying)和(he)所(suo)有(you)的(de)(de)支架相連(lian)(lian),兩頭和(he)接(jie)(jie)(jie)地(di)極連(lian)(lian)通(tong)。接(jie)(jie)(jie)地(di)線的(de)(de)規格應(ying)(ying)符合(he)設計要求(qiu)。電纜(lan)鉛包和(he)鎧裝(zhuang)除了(le)有(you)絕(jue)緣(yuan)要求(qiu)外,應(ying)(ying)全部(bu)相互連(lian)(lian)接(jie)(jie)(jie)并和(he)接(jie)(jie)(jie)地(di)線相連(lian)(lian),電纜(lan)架和(he)接(jie)(jie)(jie)地(di)線均應(ying)(ying)涂防銹漆或鍍鋅。

46、對于電纜孔洞的防火封堵有何要(yao)求?

答:對于較大的(de)電(dian)纜(lan)(lan)貫穿(chuan)孔洞,如電(dian)纜(lan)(lan)貫穿(chuan)樓板(ban)處(chu)等,采(cai)用防火堵(du)(du)料(liao)封(feng)堵(du)(du)時,應根據實際情況,先在電(dian)纜(lan)(lan)表面涂四(si)至六層防火涂料(liao),長(chang)度自(zi)孔洞以下1.5m左(zuo)右,再用耐火材料(liao)加工成具有一(yi)定強度的(de)板(ban)托防火堵(du)(du)料(liao),保(bao)證封(feng)堵(du)(du)后牢固并便于更(geng)換電(dian)纜(lan)(lan)時拆裝,封(feng)堵(du)(du)密實無(wu)孔隙(xi)以有效地(di)堵(du)(du)煙(yan)堵(du)(du)火。

47、噴燈點火前應注意哪些檢查?

答:應(ying)進行下列各(ge)項(xiang)檢查:

(1)打氣筒(tong)是(shi)否漏(lou)油或滲油,油桶及(ji)噴嘴處是(shi)否漏(lou)油、漏(lou)氣;

(2)油(you)(you)桶內(nei)的油(you)(you)量是(shi)否(fou)超過油(you)(you)桶容(rong)量的3/4,加油(you)(you)的螺絲塞是(shi)否(fou)擰緊(jin)。

48、使用(yong)噴燈應(ying)注意哪些事項?

答:(1)噴(pen)燈(deng)更(geng)大(da) 注油(you)量為(wei)油(you)筒容(rong)積的3/4;

(2)開(kai)始(shi)打氣壓力不(bu)要太大,點(dian)燃后(hou)火焰由黃變藍即可使用;

(3)周圍不(bu)得(de)有易燃物,空氣要流通;

(4)停用時先(xian)關閉調節(jie)開關,火熄(xi)后(hou),慢(man)慢(man)旋松油孔蓋放(fang)氣,空氣放(fang)完(wan)后(hou),要(yao)要(yao)旋松調節(jie)開關,完(wan)全冷卻后(hou)再旋松孔蓋;

(5)煤油噴燈與汽油噴燈要分開使用。

49、手動油壓鉗(qian)有何(he)用途?如何(he)操作(zuo)?

答:兩根(gen)導線的(de)連接(jie)通常是將兩導線端(duan)穿入相同材料制成(cheng)的(de)壓管(guan)中,用壓接(jie)鉗(qian)(qian)擠(ji)(ji)壓數個坑,使導線連接(jie)在一(yi)起,壓接(jie)時(shi)(shi),手(shou)(shou)柄(bing)向(xiang)上抬起時(shi)(shi),柱(zhu)塞(sai)(sai)向(xiang)外移(yi)(yi)動,進(jin)油(you)閥(fa)下腔產生真空(kong),油(you)箱內的(de)油(you)進(jin)入柱(zhu)塞(sai)(sai)腔。手(shou)(shou)柄(bing)下壓時(shi)(shi),柱(zhu)塞(sai)(sai)向(xiang)內移(yi)(yi)動,油(you)受壓后(hou),使進(jin)油(you)閥(fa)關(guan)閉,打開出(chu)油(you)閥(fa),使油(you)壓進(jin)入液壓缸(gang),推動活塞(sai)(sai)和(he)陽模(mo)(mo),陽、陰模(mo)(mo)之間放(fang)有壓接(jie)管(guan),當壓接(jie)被擠(ji)(ji)壓的(de)坑深到一(yi)定值時(shi)(shi),開啟回油(you)閥(fa),活塞(sai)(sai)自動返回,壓完一(yi)個坑后(hou),移(yi)(yi)動壓鉗(qian)(qian),再壓下一(yi)個。

50、常用(yong)低壓電(dian)力電(dian)纜(lan)按絕緣和(he)保(bao)護層的不(bu)同,主要可分為哪幾類?

答:(1)油浸紙(zhi)絕緣鉛包(或(huo)鋁(lv)包)電力電纜;

(2)不滴流油浸紙絕緣(yuan)電(dian)力(li)電(dian)纜(lan);

(3)聚氯乙烯絕(jue)緣(yuan)聚氯乙烯護套電力電纜;

(4)交聯聚氯乙烯絕緣聚乙烯護套電力電纜;

(5)交聯聚(ju)氯(lv)乙烯絕緣聚(ju)氯(lv)乙烯護套電(dian)力電(dian)纜;

(6)橡皮絕緣電(dian)力電(dian)纜(lan)。

51、常用絕(jue)緣材料的類(lei)別哪(na)些(xie)?舉(ju)例說明?

答(da):(1)無機絕緣材料:有云母、石(shi)棉、大理石(shi)、瓷器(qi)、玻璃等;

(2)有機絕緣材料:有樹(shu)脂、橡膠、紙(zhi)、麻、棉紗等;

(3)混合絕(jue)緣(yuan)材(cai)料:用以(yi)上絕(jue)緣(yuan)材(cai)料加工而成型的名種絕(jue)緣(yuan)材(cai)料。

52、在哪種(zhong)情(qing)況(kuang)下采用排(pai)管敷(fu)設?有什(shen)么優點?

答:排管敷設一(yi)般用(yong)在與其他建筑(zhu)物(wu)、公路或鐵路相交(jiao)叉(cha)的地方,有(you)時也在建筑(zhu)物(wu)密集(ji)區內(nei)采用(yong)。主要優點是占地少,能承(cheng)受大(da)的荷(he)重(zhong),電纜相互間互不影響,比(bi)較安全。

53、何謂電纜長期(qi)允(yun)許載流量(liang)?

答(da):電纜長期允(yun)許載流(liu)量(liang)是(shi)指在(zai)電纜內通(tong)過(guo)規定(ding)電流(liu)時,在(zai)熱穩定(ding)后(hou),電纜導(dao)體(ti)達到長期允(yun)許工作溫度時的電流(liu)數(shu)值。

54、決定(ding)電纜(lan)長期允許載(zai)流量的(de)因素有(you)哪些(xie)?

答:有以下三個因素決定:

(1)電纜(lan)的(de)長期(qi)容許工作溫度;

(2)電(dian)纜本(ben)身的(de)散熱性能;

(3)電纜裝(zhuang)置情況及(ji)周圍環境的散熱條件。

55、電(dian)纜的敷設方式有幾(ji)種?

答:有以下(xia)幾種:

(1)直埋在地(di)下;

(2)安裝在電(dian)纜溝內;

(3)安裝在(zai)地下(xia)隧道內;

(4)安裝(zhuang)在(zai)建筑物(wu)內部墻(qiang)上或(huo)天棚上;

(5)安裝(zhuang)在橋架(jia)上;

(6)敷設在排管(guan)內;

(7)敷(fu)設在水(shui)底。

56、如何進行電(dian)纜(lan)管的連(lian)接工(gong)作?

答:電纜(lan)管(guan)(guan)連接(jie)(jie)(jie)時(shi),必須用(yong)扣和管(guan)(guan)接(jie)(jie)(jie)頭(tou)連接(jie)(jie)(jie),如采用(yong)焊(han)接(jie)(jie)(jie)時(shi),不能直(zhi)接(jie)(jie)(jie)對(dui)焊(han),連接(jie)(jie)(jie)處(chu)要套上一段(duan)粗管(guan)(guan)再進行(xing)焊(han)接(jie)(jie)(jie),以免焊(han)渣掉入管(guan)(guan)內。

57、制作電纜(lan)頭時,對上(shang)下(xia)扳彎電纜(lan)芯線有(you)何要(yao)求?

答:扳彎線(xian)芯(xin)(xin)時,不(bu)(bu)得損(sun)傷紙絕(jue)緣,芯(xin)(xin)線(xian)的(de)彎曲(qu)半徑不(bu)(bu)得小(xiao)(xiao)于電纜線(xian)芯(xin)(xin)的(de)10倍(bei)。制(zhi)作(zuo)時要特別小(xiao)(xiao)心,應使(shi)線(xian)芯(xin)(xin)彎曲(qu)部分(fen)均(jun)勻受(shou)力,否(fou)則極易損(sun)傷絕(jue)緣紙。

58、簡述塑(su)料電纜的熱(re)收縮(suo)密封(feng)法。

答(da):熱(re)(re)縮(suo)(suo)法(fa)適(shi)用(yong)于(yu)中、低(di)壓橡、塑(su)電纜(lan)接頭(tou)和(he)(he)(he)終端頭(tou)的(de)密封(feng),也(ye)可適(shi)用(yong)于(yu)不滴流和(he)(he)(he)黏性浸漬絕(jue)緣電纜(lan)。采用(yong)交聯聚(ju)乙烯型和(he)(he)(he)硅橡膠(jiao)型兩大(da)類(lei)遇熱(re)(re)后(hou)(hou)能均勻收縮(suo)(suo)的(de)熱(re)(re)收縮(suo)(suo)管(guan)。將這(zhe)種管(guan)材套于(yu)預定(ding)的(de)粘合(he)密封(feng)部(bu)(bu)位,并在粘和(he)(he)(he)部(bu)(bu)位涂上熱(re)(re)熔膠(jiao),當加熱(re)(re)到一(yi)定(ding)溫(wen)度后(hou)(hou),熱(re)(re)縮(suo)(suo)管(guan)將收縮(suo)(suo),同時熱(re)(re)熔膠(jiao)熔化,待自然冷卻后(hou)(hou)即形成一(yi)道(dao)良好的(de)密封(feng)封(feng)層。

59、用電(dian)動彎(wan)(wan)管機彎(wan)(wan)制電(dian)纜保(bao)護管時應注意什(shen)么?

答(da):(1)彎管機應由了(le)解其(qi)性能并熟悉操作知(zhi)識的人員(yuan)操作;

(2)使(shi)用前必須(xu)進(jin)行檢(jian)查(cha),按(an)鈕、操作把手、行程開關應(ying)完好,彎管機必須(xu)可靠接地(di);

(3)選用符合要求(qiu)的模具(ju),確定好所需要的彎(wan)曲半徑;

(4)施工場(chang)地周圍(wei),應有充足的活動范圍(wei);

(5)使(shi)用(yong)時待空轉正常后(hou),方可帶負荷工作(zuo),運行中,嚴禁用(yong)手腳接觸其(qi)轉動(dong)部分;

(6)工(gong)作完畢應及時停電(dian),釋(shi)放(fang)油壓(ya)。

60、電(dian)纜(lan)清冊(ce)的內(nei)容(rong)及電(dian)纜(lan)編號的含義(yi)是什么?

答:電(dian)纜(lan)清冊是施放電(dian)纜(lan)和指導(dao)施工的依據,運行維護(hu)的檔案資料。應列入每根電(dian)纜(lan)的編號(hao)、起始點、型號(hao)、規格(ge)、長度(du),并(bing)分類統計出總(zong)長度(du),控纜(lan)還應列出每根電(dian)纜(lan)的備用芯(xin)。

電(dian)(dian)纜(lan)編號是識(shi)別電(dian)(dian)纜(lan)的(de)標志(zhi),故要求全廠編號不重復(fu),并且有一定的(de)含(han)義和(he)規(gui)律,能表達(da)電(dian)(dian)纜(lan)的(de)特(te)征。

61、電纜目前(qian)采用的敷設(she)方法可分為幾類?

答:(1)人(ren)工敷設,即采(cai)用人(ren)海戰(zhan)術,在一人(ren)或(huo)多(duo)人(ren)協(xie)調(diao)指揮(hui)下,按(an)規定(ding)進行敷設;

(2)機(ji)(ji)械化敷設,即采用滾輪(lun)、牽引器、輸送機(ji)(ji),通(tong)過一(yi)同(tong)步電源進行控制,比較安全;

(3)人(ren)工和機械相結(jie)合,有些(xie)現(xian)場由于轉彎較多,施工難度大,全用機械較困難,所以采(cai)用此法。

62、控(kong)制二次回路接線(xian)應符合哪些要求?

答:(1)按圖施(shi)工接線正確;

(2)導線的電氣連接(jie)應(ying)牢固可靠;

(3)盤柜內的導線不(bu)應(ying)有接頭,導線芯線應(ying)無損傷;

(4)電纜芯(xin)線端(duan)部應(ying)標明其回路(lu)編(bian)號(hao)(hao),編(bian)號(hao)(hao)應(ying)正確,字跡清晰且不易脫色;

(5)配線應整齊、清晰、美觀,導線絕緣應良好(hao)、無(wu)損;

(6)每個(ge)接(jie)(jie)線端子的(de)每側(ce)接(jie)(jie)線宜為一根(gen),最多不得超過兩根(gen)。

63、電纜排管有何要求?

答:(1)排管頂部(bu)至地面距離,在廠房內(nei)為0.2m,人行道下為0.5m,一般地區為0.7m;

(2)在變(bian)更方向及分支處均應裝置排管井(jing)坑,長度超過30mm時也應加設(she)井(jing)坑;

(3)井(jing)坑深度不(bu)小(xiao)于0.8m,人孔(kong)直徑(jing)不(bu)小(xiao)于0.7mm;

(4)排管(guan)應有傾向井(jing)坑0.5%~1%的排水坡度。

64、對于(yu)電纜導(dao)體連接點的電阻有何要求(qiu)?

答(da):要(yao)求連(lian)接點的(de)電阻(zu)小而且穩定,連(lian)接點的(de)電阻(zu)與相同長(chang)度、相同截面的(de)導體之比值,對(dui)(dui)于(yu)新安(an)裝的(de)終端頭和中間頭,應(ying)(ying)不大(da)于(yu)1;對(dui)(dui)于(yu)運行中的(de)終端頭和中間頭這個比值不應(ying)(ying)大(da)于(yu)1.2。

65、電纜接頭和中間頭的設計應(ying)滿足哪些(xie)要求?

答(da):應(ying)滿足的要(yao)求有:

(1)耐壓(ya)強度高,導體連接(jie)好;

(2)機械(xie)強度(du)大,介質損失小;

(3)結構簡單,密(mi)封性強。

66、什么(me)是(shi)電纜(lan)故障(zhang)?有幾種常見的類型?

答:電纜故障(zhang)(zhang)(zhang)是指電纜在預防性試(shi)驗時(shi)發(fa)生絕緣(yuan)擊穿或在運行中(zhong),因絕緣(yuan)擊穿、導線燒斷等而迫使電纜線路停電的故障(zhang)(zhang)(zhang)。常見的故障(zhang)(zhang)(zhang)有接地故障(zhang)(zhang)(zhang)、短路故障(zhang)(zhang)(zhang)、斷線故障(zhang)(zhang)(zhang)、閃絡性故障(zhang)(zhang)(zhang)和混(hun)合型(xing)故障(zhang)(zhang)(zhang)等。

67、如何處理電纜線路(lu)的單相接地故(gu)障(zhang)?

答:電(dian)纜(lan)線路單相接地故障(zhang)一般來說,電(dian)纜(lan)導體的(de)損(sun)傷(shang)只是局(ju)部的(de),如果屬(shu)于機械損(sun)傷(shang),而故障(zhang)點附近的(de)土壤又較干燥時,一般可進行局(ju)部修理,加添一只假接頭,即不將電(dian)纜(lan)芯鋸斷(duan),僅將故障(zhang)點絕緣(yuan)加強后密(mi)封即可。

68、電力電纜在敷設(she)前應進(jin)行哪些(xie)試驗和檢(jian)查?

答(da):敷設前應檢查(cha)電(dian)(dian)纜的型號、規格及長度是(shi)否(fou)符合要求,是(shi)否(fou)有外力(li)損傷(shang),低(di)壓電(dian)(dian)纜用1000V兆(zhao)歐表遙測絕緣電(dian)(dian)阻,阻值一般不低(di)于10MΩ,高壓電(dian)(dian)纜用2500V兆(zhao)歐表搖測阻值一般不抵于400MΩ。

69、主廠(chang)房內敷設電纜時一般應注(zhu)意什么?

答:在(zai)主廠(chang)房內敷設電纜時一般(ban)應注意:

(1)凡引至集控室的控制電纜宜架空(kong)敷(fu)設;

(2)6KV電(dian)纜宜用隧(sui)道(dao)或(huo)排(pai)管(guan)敷(fu)設(she),地下水(shui)位高處亦(yi)可架空或(huo)用排(pai)管(guan)敷(fu)設(she);

(3)380V電纜當(dang)兩端(duan)電纜在零米時宜(yi)用隧道、溝或排管(guan),當(dang)一端(duan)設備(bei)在上、一端(duan)在下時,可部分架空敷設,當(dang)地(di)下水位較高(gao)時,宜(yi)架空。

70、電力(li)電纜的內屏(ping)蔽層(ceng)與外屏(ping)蔽層(ceng)各在什(shen)么部位?采用什(shen)么材料?有何作用?

答:為了使(shi)絕緣層(ceng)和電纜(lan)導體(ti)(ti)有較(jiao)好的(de)(de)(de)接觸,消(xiao)除導體(ti)(ti)表(biao)面的(de)(de)(de)不光滑引(yin)起的(de)(de)(de)導體(ti)(ti)表(biao)面電場強度的(de)(de)(de)增加,一(yi)般(ban)在(zai)導體(ti)(ti)表(biao)面包有金(jin)(jin)屬化紙(zhi)或(huo)半導體(ti)(ti)紙(zhi)帶的(de)(de)(de)內屏(ping)(ping)蔽層(ceng)。為了使(shi)絕緣層(ceng)和金(jin)(jin)屬護套有較(jiao)好的(de)(de)(de)接觸,一(yi)般(ban)在(zai)絕緣層(ceng)外(wai)表(biao)面包有外(wai)層(ceng)屏(ping)(ping)蔽層(ceng)。外(wai)屏(ping)(ping)層(ceng)與內屏(ping)(ping)層(ceng)的(de)(de)(de)材料(liao)相同,有時還外(wai)扎銅帶或(huo)編織銅絲帶。

71、簡述環氧(yang)樹脂復合(he)物的構成(cheng)及性能。

答:環氧樹脂復合物由環氧樹脂加入硬(ying)化劑(ji)、填充劑(ji)增韌劑(ji)和稀釋劑(ji)組成。具有以(yi)下(xia)性能:

(1)有(you)足夠的機械強度;

(2)電氣性能優(you)良;

(3)電氣性能穩定;

(4)與(yu)有色(se)金屬有足夠的黏附力;

(5)耐(nai)腐蝕(shi)性好;

(6)戶(hu)外(wai)使(shi)用(yong)時,耐(nai)(nai)雨、耐(nai)(nai)光(guang)、耐(nai)(nai)濕熱。

72、單芯電纜護套一(yi)端接地方式中為什么必須安裝一(yi)條沿(yan)電纜平行敷設的(de)回(hui)流線?

答:在金(jin)屬護套(tao)(tao)一端(duan)接地的(de)電纜線路中,為(wei)確保(bao)護套(tao)(tao)中的(de)感應電壓不超過允許標準,必須安裝一條(tiao)沿電纜線路平行敷設的(de)導(dao)(dao)體(ti),且導(dao)(dao)體(ti)的(de)兩端(duan)接地,這種導(dao)(dao)體(ti)稱為(wei)回(hui)(hui)流線。當發(fa)生單相接地故(gu)障(zhang)時,接地短路電流可以通過回(hui)(hui)流線流回(hui)(hui)系統中心(xin)點,由于通過回(hui)(hui)流線的(de)接地電流產(chan)生的(de)磁(ci)通抵消了一部(bu)分電纜導(dao)(dao)線接地電流所(suo)產(chan)生的(de)磁(ci)通,因而(er)可降低(di)短路故(gu)障(zhang)時護套(tao)(tao)的(de)感應電壓。

73、電纜工程可(ke)劃分為幾個項(xiang)目?

答:(1)工地運(yun)(yun)輸:包(bao)括工程(cheng)(cheng)材料從倉庫到施工點的(de)裝(zhuang)卸、運(yun)(yun)輸和(he)空(kong)車回程(cheng)(cheng)。

(2)地方工(gong)(gong)程:包括路面(mian)開挖、隧(sui)、溝(gou)道施(shi)工(gong)(gong)等。

(3)敷(fu)設工程:包(bao)括敷(fu)設、中間頭制(zhi)作、掀蓋板(ban)、埋管、校潮、牽引頭制(zhi)作等。

(4)兩端工程:包括(kuo)支、吊橋架和其基(ji)礎的制(zhi)作安裝,終端頭制(zhi)作,油壓力和信(xin)號裝置(zhi)的安裝,名種電氣性能測試等。

(5)塞止(zhi)工程:包括充油電(dian)纜塞止(zhi)頭制(zhi)作(zuo),供油箱(xiang)、自(zi)動排水(shui)及信號裝置的安裝等。

(6)接地工(gong)程:包括絕緣接頭、換(huan)位箱、保護(hu)器、接地箱安(an)裝(zhuang)等。

74、電纜線路的(de)驗收應(ying)進行哪(na)些檢查?

答:(1)電纜規格應符合(he)規定(ding),排列應整(zheng)齊(qi),無(wu)損傷,標牌(pai)齊(qi)全、正確、清晰(xi);

(2)電纜的固(gu)定彎(wan)曲半徑、有關距離(li)及單芯電力電纜的金屬護層的接線應符合要求(qiu);

(3)電纜終(zhong)端、中間頭(tou)不(bu)滲漏油,安裝牢固,充油電纜油壓及表計(ji)整定值應符合要求(qiu);

(4)接地良好;

(5)電纜(lan)終端相(xiang)色正確,支架等的金屬(shu)部(bu)件油(you)漆完整;

(6)電(dian)纜溝及隧(sui)道內、橋(qiao)架上應無(wu)雜物,蓋板齊全。

75、電纜(lan)線路正(zheng)序阻(zu)抗(kang)測量過程中有什(shen)么要求?

答:電(dian)纜導體(ti)的交流電(dian)阻和電(dian)纜三相同感抗(kang)的相量和稱為(wei)正(zheng)序阻抗(kang)。

電(dian)(dian)(dian)纜線路的(de)正(zheng)序阻抗一(yi)般(ban)可在電(dian)(dian)(dian)纜盤(pan)上(shang)直接(jie)測(ce)量(liang),測(ce)量(liang)時(shi)一(yi)般(ban)使用較低的(de)電(dian)(dian)(dian)壓(ya)(ya)(ya),因(yin)此,需要用降壓(ya)(ya)(ya)變壓(ya)(ya)(ya)器進(jin)行降壓(ya)(ya)(ya),降壓(ya)(ya)(ya)器采用星形接(jie)線,容量(liang)一(yi)般(ban)為10kVA以上(shang),有較廣的(de)電(dian)(dian)(dian)壓(ya)(ya)(ya)調節(jie)范圍,測(ce)量(liang)時(shi)交流(liu)電(dian)(dian)(dian)源應(ying)比較穩(wen)定(ding),以保證測(ce)量(liang)時(shi)電(dian)(dian)(dian)流(liu)達(da)到規(gui)定(ding)的(de)要求,實際電(dian)(dian)(dian)壓(ya)(ya)(ya)表(biao)的(de)讀(du)數(shu)值必須是(shi)電(dian)(dian)(dian)纜端的(de)電(dian)(dian)(dian)壓(ya)(ya)(ya),試驗電(dian)(dian)(dian)流(liu)更好 接(jie)近電(dian)(dian)(dian)纜長(chang)期允許載(zai)流(liu)量(liang),測(ce)讀(du)各表(biao)計(ji)的(de)數(shu)值時(shi),合上(shang)電(dian)(dian)(dian)流(liu)后同時(shi)讀(du)取三個(ge)表(biao)的(de)數(shu)值。

76、根據《電業生產安全規定》,電氣工作(zuo)人員必須具(ju)備的條(tiao)件是什么(me)?

答:必(bi)須具備下列條件:

(1)經(jing)醫生鑒定身體健(jian)康,無妨(fang)礙工(gong)作的病癥;

(2)具備必要(yao)的電(dian)氣(qi)知識,按(an)其職務和工作性質掌(zhang)握相(xiang)關的規程、專業(ye)技術及安全操(cao)作技術,并經考試(shi)合格;

(3)熟練(lian)掌(zhang)握觸電急救方(fang)法。

77、電纜在運輸裝卸過程中應(ying)注(zhu)意什么?

答:(1)在(zai)運輸裝(zhuang)卸過(guo)程中,不(bu)應使(shi)電(dian)纜(lan)及電(dian)纜(lan)盤受到損傷(shang),嚴禁將電(dian)纜(lan)盤直接由車上(shang)推下(xia),電(dian)纜(lan)般不(bu)應平放運輸,平放貯存。

(2)運輸或滾動電(dian)纜盤(pan)前(qian),必(bi)須(xu)保證電(dian)纜盤(pan)牢固,電(dian)纜繞(rao)緊、充油電(dian)纜至(zhi)壓力油箱間的(de)油管(guan)應(ying)固定,不得損傷(shang),壓力油箱應(ying)牢固,壓力指示應(ying)符合要(yao)求。

78、電纜防(fang)火(huo)有哪些措施?

答(da):(1)采用阻燃電纜(lan);

(2)采用防火電纜托架;

(3)采用防火涂料;

(4)電纜隧(sui)道、夾層出口等處設置防火隔墻、防火擋板(ban);

(5)架(jia)空電纜(lan)應避(bi)開油管道、防爆門,否則應有要取局部穿(chuan)管或隔熱防火措施。

79、選(xuan)擇電力電纜的截面(mian)應從哪(na)幾個方面(mian)考慮?

答:應考慮如(ru)下(xia)幾個(ge)方(fang)面:

(1)電(dian)纜長期允(yun)許通過的工作(zuo)電(dian)流;

(2)一(yi)旦(dan)短路時的熱穩定性;

(3)線(xian)路上的電壓降(jiang)不能(neng)超出允許工(gong)作范圍。

80、電力電纜和架空線比較(jiao)有哪些優點?

答:(1)運行可靠,由于安(an)裝在地下等隱蔽處,受外(wai)力破壞小,發生故(gu)障(zhang)的機會(hui)較(jiao)少,供電安(an)全,不會(hui)給(gei)人身造成危害;

(2)維護工作量小,不需頻繁的巡檢(jian);

(3)不需架設(she)桿(gan)塔;

(4)有(you)助于提高功率因數。