1、常用(yong)的電線、電纜按用(yong)途分有哪(na)些種類?
答:按用途可(ke)分為裸導(dao)線、絕緣電(dian)(dian)(dian)(dian)線、耐熱電(dian)(dian)(dian)(dian)線、屏(ping)蔽電(dian)(dian)(dian)(dian)線、電(dian)(dian)(dian)(dian)力電(dian)(dian)(dian)(dian)纜(lan)、控制電(dian)(dian)(dian)(dian)纜(lan)、通(tong)信(xin)電(dian)(dian)(dian)(dian)纜(lan)、射頻電(dian)(dian)(dian)(dian)纜(lan)等。
2、絕(jue)緣電線(xian)有(you)哪(na)幾種?
答:常有的(de)絕(jue)緣(yuan)(yuan)電(dian)(dian)線(xian)有以下(xia)幾(ji)種:聚(ju)氯(lv)(lv)乙(yi)烯(xi)絕(jue)緣(yuan)(yuan)電(dian)(dian)線(xian)、聚(ju)氯(lv)(lv)乙(yi)烯(xi)絕(jue)緣(yuan)(yuan)軟(ruan)線(xian)、丁腈聚(ju)氯(lv)(lv)乙(yi)烯(xi)混合(he)物絕(jue)緣(yuan)(yuan)軟(ruan)線(xian)、橡(xiang)皮(pi)絕(jue)緣(yuan)(yuan)電(dian)(dian)線(xian)、農用地下(xia)直(zhi)埋(mai)鋁芯塑料絕(jue)緣(yuan)(yuan)電(dian)(dian)線(xian)、橡(xiang)皮(pi)絕(jue)緣(yuan)(yuan)棉紗(sha)紡(fang)織(zhi)軟(ruan)線(xian)、聚(ju)氯(lv)(lv)乙(yi)烯(xi)絕(jue)緣(yuan)(yuan)尼龍護套電(dian)(dian)線(xian)、電(dian)(dian)力和照(zhao)明用聚(ju)氯(lv)(lv)乙(yi)烯(xi)絕(jue)緣(yuan)(yuan)軟(ruan)線(xian)等。
3、電纜橋架適合(he)于何種場合(he)?
答(da):電(dian)(dian)(dian)纜橋(qiao)架(jia)適用于(yu)一(yi)般工礦企業室內(nei)外架(jia)空敷設(she)(she)電(dian)(dian)(dian)力電(dian)(dian)(dian)纜、控(kong)制電(dian)(dian)(dian)纜,亦可用于(yu)電(dian)(dian)(dian)信、廣(guang)播電(dian)(dian)(dian)視等(deng)部門在室內(nei)外架(jia)設(she)(she)。
4、電纜附件(jian)有哪些(xie)?
答:常用(yong)的電附件有電纜終端(duan)接線(xian)盒、電纜中(zhong)間接線(xian)盒、連(lian)接管及接線(xian)端(duan)子、鋼板接線(xian)槽、電纜橋架(jia)等。
5、什么叫電纜中(zhong)間(jian)接頭?
答(da):連(lian)接(jie)電(dian)纜(lan)與(yu)電(dian)纜(lan)的(de)導(dao)體、絕緣(yuan)屏蔽層和保護層,以使電(dian)纜(lan)線路連(lian)接(jie)的(de)裝置(zhi),稱為電(dian)纜(lan)中(zhong)間接(jie)頭。
6、什么(me)叫(jiao)電氣主接線?
答:電(dian)(dian)氣主接線是發電(dian)(dian)廠、變電(dian)(dian)所(suo)中主要(yao)電(dian)(dian)氣設(she)備和母線的連(lian)接方(fang)式(shi),包(bao)括主母線和廠用電(dian)(dian)系統(tong)按一定的功能(neng)要(yao)求(qiu)的連(lian)接方(fang)式(shi)。
7、在選擇(ze)電力電纜的截(jie)面時,應遵照哪(na)些規定?
答(da):電(dian)(dian)(dian)(dian)力電(dian)(dian)(dian)(dian)纜的(de)(de)選擇應遵照以下原則:(1)電(dian)(dian)(dian)(dian)纜的(de)(de)額(e)(e)定電(dian)(dian)(dian)(dian)壓(ya)要大(da)于(yu)或等于(yu)安裝點供(gong)電(dian)(dian)(dian)(dian)系(xi)統的(de)(de)額(e)(e)定電(dian)(dian)(dian)(dian)壓(ya);(2)電(dian)(dian)(dian)(dian)纜持(chi)續(xu)容許電(dian)(dian)(dian)(dian)流(liu)應等于(yu)或大(da)于(yu)供(gong)電(dian)(dian)(dian)(dian)負載的(de)(de)更大(da) 持(chi)續(xu)電(dian)(dian)(dian)(dian)流(liu);(3)線芯(xin)截面要滿足供(gong)電(dian)(dian)(dian)(dian)系(xi)統短路(lu)時的(de)(de)穩定性的(de)(de)要求(qiu);(4)根(gen)據電(dian)(dian)(dian)(dian)纜長度驗算電(dian)(dian)(dian)(dian)壓(ya)降是否(fou)符合要求(qiu);(5)線路(lu)末端的(de)(de)最小短路(lu)電(dian)(dian)(dian)(dian)流(liu)應能使保護裝置可靠的(de)(de)動作。
8、交聯聚(ju)乙烯電纜(lan)和油紙(zhi)電纜(lan)比較有哪些優(you)點?
答(da):(1)易(yi)安裝,因為(wei)(wei)它允許(xu)最小彎曲半徑小、且重量輕(qing);(2)不受線路(lu)落差*;(3)熱性(xing)(xing)能好,允許(xu)工(gong)作溫(wen)度(du)高、傳(chuan)輸(shu)容量大(da);(4)電(dian)纜附件(jian)簡(jian)單,均(jun)為(wei)(wei)干式結構(gou);(5)運行(xing)維(wei)護簡(jian)單,無漏油(you)問(wen)題(ti);(6)價格較低(di);(7)可靠性(xing)(xing)高、故障(zhang)率低(di);(8)制造(zao)工(gong)序少、工(gong)藝簡(jian)單,經濟效益顯著。
9、固定交(jiao)流單芯電(dian)纜的夾具有什么要求?為什么?
答:夾(jia)具(ju)應無鐵(tie)件(jian)構(gou)成(cheng)閉(bi)合(he)磁(ci)路,這是因(yin)為當(dang)電(dian)纜(lan)線芯通過電(dian)流時,在其周(zhou)圍產(chan)生磁(ci)力(li)線,磁(ci)力(li)線與通過線芯的電(dian)流大小成(cheng)正比(bi),若(ruo)使(shi)(shi)用鐵(tie)件(jian)等導(dao)磁(ci)材(cai)料,根(gen)據(ju)電(dian)磁(ci)感(gan)應可知,將在鐵(tie)件(jian)中產(chan)生渦流使(shi)(shi)電(dian)纜(lan)發(fa)熱,甚(shen)至(zhi)燒(shao)壞電(dian)纜(lan)。所以(yi)不可使(shi)(shi)用鐵(tie)件(jian)作單芯交流電(dian)纜(lan)的固定(ding)夾(jia)具(ju)。
10、以(yi)下的(de)熱縮電纜頭的(de)附(fu)件的(de)更(geng)大 特點(dian)和優(you)點(dian)是什么?
答:熱(re)(re)縮(suo)附(fu)(fu)件的(de)(de)(de)(de)更大 特點(dian)是用(yong)應力管代(dai)替傳統的(de)(de)(de)(de)應力錐(zhui),它不僅簡化了施工工藝(yi),還縮(suo)小了接頭(tou)的(de)(de)(de)(de)終(zhong)端(duan)的(de)(de)(de)(de)尺寸(cun),安(an)裝方(fang)便(bian),省時省工,性(xing)能優越,節約(yue)金(jin)屬(shu)。熱(re)(re)縮(suo)電纜附(fu)(fu)件集灌注式(shi)和干(gan)包(bao)式(shi)為一體,集合了這兩種附(fu)(fu)件的(de)(de)(de)(de)優點(dian)。
11、電纜敷設(she)前應(ying)進行哪些(xie)檢查工作(zuo)?
答:(1)支架應(ying)(ying)(ying)(ying)齊全、油(you)漆(qi)完整。(2)電(dian)纜(lan)(lan)(lan)型號、電(dian)壓(ya)、規格符合設計。(3)電(dian)纜(lan)(lan)(lan)絕緣良好,當對油(you)紙電(dian)纜(lan)(lan)(lan)的密封(feng)有懷疑(yi)時,應(ying)(ying)(ying)(ying)進行(xing)受潮判(pan)斷;直埋電(dian)纜(lan)(lan)(lan)與(yu)小(xiao)底電(dian)纜(lan)(lan)(lan)應(ying)(ying)(ying)(ying)經直流耐壓(ya)試(shi)(shi)難合格;充油(you)電(dian)纜(lan)(lan)(lan)的油(you)樣(yang)應(ying)(ying)(ying)(ying)試(shi)(shi)驗合格。(4)充油(you)電(dian)纜(lan)(lan)(lan)的油(you)壓(ya)不宜低于1.47MPa。
11、交聯熱收縮電(dian)纜附(fu)件有(you)哪些優點?
答:這是一(yi)種新型材料,它與現在其(qi)他類(lei)型附件比較(jiao)具有電氣性能優越、體(ti)積小、質量小、安(an)裝(zhuang)簡便、材料配套等(deng)優點,另外(wai)還(huan)具有耐氣候、抗污(wu)穢性、阻燃自熄等(deng)能力(li)。
12、對油紙絕(jue)緣電力電纜密封有(you)懷疑時,如何用(yong)較簡單的辦(ban)法檢查電纜絕(jue)緣紙是否受潮?
答(da):把電纜絕緣紙點燃或(huo)(huo)放(fang)入150℃左(zuo)右的(de)電纜油中檢(jian)查,無“嘶嘶”聲或(huo)(huo)白色泡沫出現,說明未受潮。
13、電纜(lan)標(biao)志(zhi)牌應(ying)注明什么(me)內容(rong)?編寫有(you)何(he)要求?
答:標志(zhi)牌上(shang)應(ying)注明電纜(lan)線路設計編號、電纜(lan)型號、規(gui)格及始點,并聯(lian)使用的電纜(lan)應(ying)有順序號。要求字跡清晰、不易脫(tuo)落。
14、直埋電纜的(de)方位標(biao)志應設置在哪些(xie)位置?
答(da):在電纜(lan)(lan)(lan)兩端,電纜(lan)(lan)(lan)直線(xian)段50~100m處(chu)電纜(lan)(lan)(lan)接頭幾電纜(lan)(lan)(lan)改變方(fang)向的彎角處(chu)。
15、制作電(dian)纜接頭(tou)用的黃臘綢帶(dai)、黑玻璃漆帶(dai)、無堿玻璃絲帶(dai)等,施(shi)工(gong)前如何進行排潮處理?
答:(1)恒(heng)溫干(gan)(gan)(gan)燥(zao)(zao)法:將絕(jue)緣(yuan)帶卷(juan)成直徑為25~30mm小卷(juan),放(fang)入110~120℃恒(heng)溫干(gan)(gan)(gan)燥(zao)(zao)箱內(nei)烘4~5h,冷卻干(gan)(gan)(gan)取(qu)(qu)出,放(fang)入干(gan)(gan)(gan)燥(zao)(zao)的密封筒內(nei)。(2)油(you)浸排潮法:將絕(jue)緣(yuan)帶小卷(juan)放(fang)入恒(heng)溫在120~130℃的電纜油(you)中,離鍋底保(bao)持30mm距離,經一(yi)定時間后(hou)油(you)面(mian)不再產生泡(pao)沫后(hou)取(qu)(qu)出,裝入貯有電纜油(you)的桶(tong)中,油(you)位應超過(guo)所(suo)有裝入的物體并將其密封。
16、電纜(lan)外護層(ceng)的作(zuo)用是什么(me)?
答:保(bao)護內護層不受機(ji)械損傷和化學腐(fu)蝕,增強(qiang)機(ji)械強(qiang)度(du)。
17、室外電(dian)纜(lan)溝應符(fu)合(he)哪些要求?
答:電纜(lan)溝上(shang)部應(ying)比地面稍高,加蓋用混凝土(tu)制(zhi)作的蓋板,電纜(lan)應(ying)平敷在支架上(shang),有良好的排水管。
18、電纜內護層的作用(yong)是(shi)什(shen)么?
答;使絕(jue)緣(yuan)層(ceng)不(bu)會與水、空氣或其他物體接(jie)觸,防止絕(jue)緣(yuan)受潮(chao)和絕(jue)緣(yuan)層(ceng)不(bu)受機械傷害(hai)。
19、使(shi)用鋼(gang)絲鉗(qian)時(shi)應注(zhu)意些什么?
答:使用(yong)前,一定(ding)要檢查(cha)絕緣(yuan)(yuan)柄的絕緣(yuan)(yuan)是否完(wan)好無損,使用(yong)時不可用(yong)鋼(gang)(gang)絲鉗(qian)剪切超(chao)過規格所允許(xu)的金屬線(xian)材,并禁止用(yong)鋼(gang)(gang)絲鉗(qian)代替錘(chui)子敲打(da)工(gong)具,以(yi)免損壞。
20、什(shen)么叫絕緣強度?
答:絕緣(yuan)(yuan)物質在電(dian)(dian)場(chang)中,當電(dian)(dian)場(chang)強(qiang)(qiang)度增大到某一極限時就會被擊穿(chuan),這個(ge)導致(zhi)絕緣(yuan)(yuan)擊穿(chuan)的電(dian)(dian)場(chang)強(qiang)(qiang)度稱為(wei)絕緣(yuan)(yuan)強(qiang)(qiang)度。
22、對電纜(lan)導體連接點的機械強度有(you)何(he)要求?
答:連接點的機械強(qiang)度,一般低(di)于電纜導(dao)體本身的抗(kang)拉強(qiang)度,對于固定敷設的電力(li)電纜,其連接點的抗(kang)拉強(qiang)度要求(qiu)不低(di)于導(dao)體本身抗(kang)拉強(qiang)度的60%。
23、電力電纜的絕緣(yuan)層材料應具備哪些主要性能?
答;應具備下(xia)列主要性(xing)(xing)能(neng):(1)高的(de)(de)擊(ji)穿(chuan)強度;(2)低的(de)(de)介質損(sun)耗;(3)相當高的(de)(de)絕緣(yuan)電阻;(4)優良的(de)(de)耐放電性(xing)(xing)能(neng);(5)具有一定(ding)的(de)(de)柔軟性(xing)(xing)和機械強度;(6)絕緣(yuan)性(xing)(xing)能(neng)長期(qi)穩(wen)定(ding)。
24、機械敷設電纜時,牽(qian)引(yin)強度有何規定(ding)?
答:對(dui)于銅芯(xin)電(dian)纜(lan),當牽(qian)(qian)引(yin)頭部(bu)時,允(yun)許牽(qian)(qian)引(yin)強度(du)為70N/cm;對(dui)于鋁芯(xin)電(dian)纜(lan),當牽(qian)(qian)引(yin)頭部(bu)時,允(yun)許牽(qian)(qian)引(yin)強度(du)為40N/cm;若利用鋼絲網套牽(qian)(qian)引(yin)時,鉛護(hu)套電(dian)纜(lan)允(yun)許強度(du)為10N/cm;鉛護(hu)套電(dian)纜(lan)為40N/cm。
25、對(dui)電纜(lan)保護管有何規定(ding)?
答:(1)電纜需要穿保護(hu)管(guan)敷設時(shi),管(guan)子內(nei)徑(jing)不(bu)應(ying)小(xiao)(xiao)于電纜外徑(jing)的1.5倍,混(hun)凝土(tu)管(guan)、陶土(tu)管(guan)、石棉(mian)、水泥管(guan)的內(nei)徑(jing)不(bu)應(ying)小(xiao)(xiao)于100mm;
(2)電纜管的(de)彎(wan)曲(qu)半徑(jing)應符合(he)所穿(chuan)入電纜彎(wan)曲(qu)半徑(jing)的(de)規定;
(3)每根管子(zi)最(zui)多不應超過三個彎頭(tou),直角彎不應多于2個。
26、如(ru)何測量電(dian)纜護套的(de)外徑?
答:在護(hu)(hu)套圓周(zhou)上均(jun)勻分布的五點處,測量護(hu)(hu)套外(wai)徑和其平均(jun)值(zhi),其平均(jun)外(wai)徑既(ji)為護(hu)(hu)套的外(wai)徑。
27、不同截面的銅芯電纜如(ru)何連(lian)接?
答(da):不同(tong)截面(mian)的(de)(de)銅芯電纜(lan)連(lian)接(jie)(jie)(jie)(jie),可(ke)采(cai)用(yong)開口弱背(bei)銅接(jie)(jie)(jie)(jie)管(guan)(guan),以錫焊法(fa)連(lian)接(jie)(jie)(jie)(jie),也可(ke)用(yong)純銅棒按不同(tong)的(de)(de)截面(mian)要(yao)求連(lian)接(jie)(jie)(jie)(jie)成銅接(jie)(jie)(jie)(jie)管(guan)(guan),以壓接(jie)(jie)(jie)(jie)法(fa)連(lian)接(jie)(jie)(jie)(jie)。
28、簡述10KV交聯電纜熱縮式制作戶內終端頭的過程?
答;(1)準備階段:檢查(cha)熱縮電纜附件是否齊備,型號是否相配,檢查(cha)并(bing)確認電纜有無潮氣后,檢查(cha)電纜。
(2)切除(chu)多余(yu)電(dian)纜,根據現(xian)場情況決定電(dian)纜長(chang)度。
(3)剝除(chu)護(hu)層。
(4)焊(han)接接地線,將(jiang)接地線焊(han)接在(zai)鋼(gang)帶上(shang)。
(5)填充(chong)三叉口及繞包密(mi)封膠。
(6)安裝三芯(xin)分(fen)支護套,將護套套入(ru)根部(bu)(bu),從中(zhong)部(bu)(bu)開始收(shou)縮,先往(wang)根部(bu)(bu),再往(wang)指部(bu)(bu)。
(7)剝銅 帶和外半導電層(ceng),剝切三芯分支套口20mm以上的銅帶,嚴禁(jin)損傷主絕緣,清除干凈(jing)半導電層(ceng)。
(8)安裝應力(li)管,管口端部(bu)分支套對接后熱(re)縮。
(9)安裝(zhuang)接線端子。
(10)安裝絕緣管(guan)。
(11)安裝密封管。
(12)核相后安裝相色管。
29、戶內、戶外(wai)預(yu)制式終端安裝(zhuang)步驟有哪些?
答(da):(1) 將電纜按預定位置就位、固(gu)定、清潔表面,參照說明書剝除(chu)外護套,如有(you)特(te)殊需要,外護套剝切長度可調整,分別(bie)由銅(tong)帶(dai)、外護套鎧裝引出(chu)2組地線。
(2) 由(you)(you)外護套口(kou)向(xiang)上量取需要尺寸(cun),切除多余電纜,套入熱縮三指(zhi)套至(zhi)三叉口(kou)根部由(you)(you)中(zhong)間加熱收(shou)縮,由(you)(you)指(zhi)套上口(kou)向(xiang)上量取規定(ding)尺寸(cun)(35kv為350~380mm)。去(qu)掉多余銅(tong)帶(保留(liu)20mm),再(zai)保留(liu)半導(dao)體預(yu)定(ding)位置(zhi),壓接(jie)出(chu)線端子密封。
30、電(dian)(dian)線電(dian)(dian)纜的應用(yong)主(zhu)要(yao)分為三大類 :
(1)、電(dian)力系統
電(dian)(dian)(dian)(dian)(dian)(dian)力系統(tong)采用(yong)的電(dian)(dian)(dian)(dian)(dian)(dian)線(xian)電(dian)(dian)(dian)(dian)(dian)(dian)纜產品主要有架空裸電(dian)(dian)(dian)(dian)(dian)(dian)線(xian)、匯流排(母線(xian))、電(dian)(dian)(dian)(dian)(dian)(dian)力電(dian)(dian)(dian)(dian)(dian)(dian)纜(塑料線(xian)纜、油(you)紙力纜(基本被塑料電(dian)(dian)(dian)(dian)(dian)(dian)力電(dian)(dian)(dian)(dian)(dian)(dian)纜代(dai)替)、橡(xiang)套線(xian)纜、架空絕緣電(dian)(dian)(dian)(dian)(dian)(dian)纜)、分支(zhi)電(dian)(dian)(dian)(dian)(dian)(dian)纜(取(qu)代(dai)部分母線(xian))、電(dian)(dian)(dian)(dian)(dian)(dian)磁(ci)線(xian)以(yi)及電(dian)(dian)(dian)(dian)(dian)(dian)力設備(bei)用(yong)電(dian)(dian)(dian)(dian)(dian)(dian)氣裝備(bei)電(dian)(dian)(dian)(dian)(dian)(dian)線(xian)電(dian)(dian)(dian)(dian)(dian)(dian)纜等。
(2)、信息傳輸系統
用于信息傳輸系統的電(dian)(dian)線電(dian)(dian)纜主要有市話電(dian)(dian)纜、電(dian)(dian)視電(dian)(dian)纜、電(dian)(dian)子線纜、射頻電(dian)(dian)纜、光纖纜、數(shu)據電(dian)(dian)纜、電(dian)(dian)磁線、電(dian)(dian)力通訊或(huo)其他復合電(dian)(dian)纜等(deng)。
(3)、機械(xie)設備、儀器儀表系統(tong)
此部分(fen)除架空裸電(dian)線(xian)(xian)外幾乎其他所(suo)有(you)產(chan)品(pin)均有(you)應用,但主要是電(dian)力電(dian)纜、電(dian)磁(ci)線(xian)(xian)、數據電(dian)纜、儀器儀表線(xian)(xian)纜等。
31、電線電纜產品主要(yao)分為五大類:
(1)、裸電(dian)線及(ji)裸導體制(zhi)品(pin)(pin) 本(ben)類產(chan)(chan)品(pin)(pin)的(de)(de)主要特征是(shi):純的(de)(de)導體金屬,無絕(jue)緣及(ji)護套層,如(ru)(ru)鋼芯(xin)鋁絞(jiao)(jiao)(jiao)線、銅鋁匯流(liu)排、電(dian)力(li)機車線等(deng);加工工藝(yi)主要是(shi)壓力(li)加工,如(ru)(ru)熔煉、壓延、拉制(zhi)、絞(jiao)(jiao)(jiao)合/緊壓絞(jiao)(jiao)(jiao)合等(deng);產(chan)(chan)品(pin)(pin)主要用(yong)在城(cheng)郊(jiao)、農村、用(yong)戶主線、開(kai)關(guan)柜等(deng)。
(2)、電(dian)(dian)力電(dian)(dian)纜(lan)(lan)本類產(chan)品主要特征(zheng)是:在導體外擠(ji)(繞(rao))包絕緣(yuan)層,如(ru)架(jia)(jia)空絕緣(yuan)電(dian)(dian)纜(lan)(lan),或(huo)幾芯絞(jiao)(jiao)合(對應電(dian)(dian)力系統的相線、零(ling)線和地線),如(ru)二芯以上架(jia)(jia)空絕緣(yuan)電(dian)(dian)纜(lan)(lan),或(huo)再增加(jia)護套(tao)層,如(ru)塑料/橡套(tao)電(dian)(dian)線電(dian)(dian)纜(lan)(lan)。主要的工(gong)藝技術(shu)有(you)拉(la)制、絞(jiao)(jiao)合、絕緣(yuan)擠(ji)出(chu)(繞(rao)包)、成纜(lan)(lan)、鎧裝、護層擠(ji)出(chu)等,各種產(chan)品的不同工(gong)序組合有(you)一定區(qu)別。
產品(pin)主要(yao)用(yong)在發、配、輸、變、供(gong)電(dian)(dian)線路中的(de)強電(dian)(dian)電(dian)(dian)能(neng)傳輸,通過的(de)電(dian)(dian)流大(da)(幾(ji)十(shi)安至(zhi)幾(ji)千安)、電(dian)(dian)壓(ya)高(220V至(zhi)500kV及以上)。
(3)、電(dian)氣裝備用(yong)(yong)(yong)電(dian)線電(dian)纜該類(lei)產品主要特征是:品種規格繁多,應(ying)用(yong)(yong)(yong)范圍廣泛,使(shi)用(yong)(yong)(yong)電(dian)壓在1kV及以(yi)下較(jiao)多,面(mian)對特殊場合不(bu)斷衍生新的產品,如耐火線纜、阻燃線纜、低煙無鹵/低煙低鹵線纜、防白蟻、防老鼠線纜、耐油/耐寒/耐溫/耐磨線纜、醫用(yong)(yong)(yong)/農用(yong)(yong)(yong)/礦用(yong)(yong)(yong)線纜、薄壁電(dian)線等(deng)。
(4)、通(tong)訊電纜及(ji)光纖(簡(jian)略介紹)隨著近(jin)二十多年來,通(tong)訊行業的(de)飛(fei)速(su)發(fa)展,產品(pin)也有驚(jing)人的(de)發(fa)展速(su)度。從過(guo)去(qu)的(de)簡(jian)單的(de)電話電報線(xian)纜發(fa)展到幾千對的(de)話纜、同(tong)軸纜、光纜、數據電纜,甚至組(zu)合(he)通(tong)訊纜等。
該類(lei)產品結構尺寸通常較小而均勻(yun),制(zhi)造(zao)精度要求高(gao)。
(5)、電(dian)磁線(繞組(zu)線)主要用于各種電(dian)機、儀器儀表等。
電線電纜的衍生/新(xin)產(chan)品
電(dian)線電(dian)纜的(de)衍生/新(xin)產品主要是因應用場合、應用要求不(bu)同(tong)及裝備的(de)方便性和(he)降低裝備成本等的(de)要求,而采(cai)用新(xin)材料(liao)、特殊材料(liao)、或改變產品結構、或提高工藝要求、或將不(bu)同(tong)品種的(de)產品進行組合而產生。
采用不同材料如(ru)阻燃線(xian)(xian)纜(lan)、低煙無鹵(lu)(lu)/低煙低鹵(lu)(lu)線(xian)(xian)纜(lan)、防白(bai)蟻、防老鼠線(xian)(xian)纜(lan)、耐油/耐寒/耐溫線(xian)(xian)纜(lan)等;
改(gai)變產品結構如:耐火電(dian)纜等;
提高工藝要求如:醫用線纜(lan)等;
組合(he)產品(pin)如:OPGW等(deng);
方便安裝和(he)降低裝備成本如:預制分支電(dian)纜等。
32、母線裝置(zhi)施工完,應進行哪些檢查?
答:應進行下列檢查(cha):
(1)金屬構件(jian)的(de)加工(gong)、配制、焊(han)接螺接應符合規定;
(2)各(ge)部螺栓(shuan)、墊圈(quan)、開口銷等零部件(jian)應齊全可(ke)靠;
(3)母線配制及安(an)裝架應(ying)符(fu)合規定,相間及對地電氣距離符(fu)合要求;
(4)瓷(ci)件(jian)、鐵件(jian)及膠合處應(ying)完整,充(chong)油(you)套管應(ying)無滲油(you),油(you)位(wei)正常;
(5)油漆完整,相色正確,接(jie)地良好。
33、在35kv及以下電力(li)電纜接頭中(zhong),改善其(qi)護套(tao)斷開處電場(chang)分布的(de)方(fang)法有幾(ji)種(請列(lie)出五種),并(bing)簡述其(qi)方(fang)法。
答:(1)脹(zhang)喇(la)叭口:在(zai)鉛包割斷處把(ba)鉛包邊緣撬起,成喇(la)叭狀,其邊緣應光滑(hua)、圓整、對稱(cheng)。
(2)預留統(tong)包(bao)絕(jue)緣:在鉛包(bao)切口至電纜芯線(xian)分開點之(zhi)間留有一段統(tong)包(bao)絕(jue)緣紙。
(3)切除(chu)半導(dao)電(dian)紙:將(jiang)半導(dao)電(dian)紙切除(chu)到喇叭(ba)口以下。
(4)包(bao)繞應(ying)力錐:用絕緣包(bao)帶和導電(dian)金屬材料包(bao)成錐形,人為地將屏蔽層擴大,以改善(shan)電(dian)場分布(bu)。
(5)等電位法(fa):對于(yu)干包(bao)型或交聯聚乙烯電纜頭(tou),在各線芯(xin)概況(kuang)絕緣表面上包(bao)一段金屬帶,并(bing)將其連接在一起。
(6)裝設應(ying)力控制管(guan):對于35kv及發下熱(re)縮(suo)管(guan)電纜頭,首先從線(xian)芯銅(tong)屏(ping)蔽(bi)層末(mo)端方向經半導體帶至線(xian)芯絕緣概(gai)況包繞2層半導體帶,然后將相應(ying)規格折應(ying)力管(guan),套在銅(tong)屏(ping)蔽(bi)的末(mo)端處,熱(re)縮(suo)成形。
34、電纜支架的加工應符合(he)哪些(xie)要求?
答:(1)鋼材應平直(zhi),無明顯扭曲,下料誤(wu)差應在5mm范圍內,切口應無卷邊,毛(mao)剌;
(2)支架應焊接牢固,無顯蓍變形,各橫撐間的垂直凈距與設計偏差不應大于5mm;
(3)金屬(shu)支架必(bi)須(xu)進行防(fang)腐(fu)處(chu)理,位于濕熱、鹽、霧以及有化學(xue)腐(fu)蝕(shi)地區時,應根據設(she)計作(zuo)特殊的防(fang)腐(fu)處(chu)理。
35、列舉出你熟悉的(de)電纜架。
答:拼焊式E型(xing)架、裝配式E型(xing)架、橋式電(dian)(dian)纜架、電(dian)(dian)纜托架、掛鉤式支架、單(dan)根(gen)電(dian)(dian)纜支架等。
36、敷設電纜(lan)應滿足哪(na)些要(yao)求?
答:應滿足以下要求:
(1)安(an)全運行方(fang)面(mian),盡可(ke)能避免各種外來損(sun)壞,提(ti)高電纜線(xian)路的供(gong)電可(ke)靠性;
(2)經濟方(fang)面,從投資最省的方(fang)面考慮;
(3)施工方面,電纜線路的路徑必須便于旋工和投(tou)運后的維(wei)修(xiu)。
37、制作電(dian)纜終端(duan)頭或中間接頭的(de)絕緣材料(liao)有哪些(xie)?
答:有絕(jue)緣(yuan)膠、絕(jue)緣(yuan)帶、絕(jue)緣(yuan)管、絕(jue)緣(yuan)手套(tao)、絕(jue)緣(yuan)樹脂等。
38、簡述電(dian)纜(lan)頭制(zhi)作(zuo)的(de)一般(ban)操作(zuo)程序。答:(1)制(zhi)作(zuo)前的(de)準備:包括○1閱讀安裝說明書;○2察看現(xian)場;○3備料;○4電(dian)纜(lan)試(shi)潮;○5制(zhi)作(zuo)前測試(shi)等。
(2)接頭的制作(zuo)過程:包括○1割斷多余(yu)電(dian)纜;○2電(dian)纜保(bao)護層的剝切;○3導體(ti)連(lian)接;○4包繞絕(jue)緣(或收(shou)縮管材);○5安裝接頭外殼;○6灌注(zhu)絕(jue)緣劑;○7進行密封處理等(deng)。
(3)制作(zuo)后(hou)電氣測試。
39、電纜保護管的加工應符合哪些要(yao)求(qiu)?
答:(1)管口(kou)應(ying)*剌和(he)尖銳楞角,管口(kou)宜做成喇叭形。
(2)電(dian)(dian)纜(lan)管(guan)在彎(wan)制后(hou),不(bu)應(ying)有裂縫和顯著的(de)凹癟現象,其(qi)彎(wan)扁(bian)程度(du)不(bu)宜大于(yu)管(guan)子外徑10%;電(dian)(dian)纜(lan)管(guan)的(de)彎(wan)曲(qu)半(ban)徑不(bu)應(ying)小(xiao)于(yu)所(suo)穿入電(dian)(dian)纜(lan)的(de)最小(xiao)允(yun)許彎(wan)曲(qu)半(ban)徑。
(3)金屬(shu)管應(ying)在外表涂防(fang)腐漆或(huo)瀝表,鍍鋅(xin)管鋅(xin)層剝落處也應(ying)涂以防(fang)腐漆。
40、電(dian)纜的(de)排列符合哪(na)些(xie)要求?答(da):(1)電(dian)力電(dian)纜和控纜不應配置在同一(yi)層支架上。
(2)高、低壓電纜,強、弱電控纜應按須序分層配置(zhi),一般情況宜由上而下,但在含有(you)35kv以(yi)上高壓電纜引入柜盤時,為滿(man)足(zu)彎曲半徑,可由下面上配置(zhi)。
41、電纜(lan)(lan)溝內敷設電纜(lan)(lan)的方法(fa)是(shi)什么?
答(da):在電(dian)(dian)纜(lan)(lan)(lan)(lan)溝(gou)內(nei)敷設電(dian)(dian)纜(lan)(lan)(lan)(lan)的方(fang)法(fa)與直埋(mai)電(dian)(dian)纜(lan)(lan)(lan)(lan)的敷設方(fang)法(fa)相仿,一(yi)般可將滑輪(lun)放在溝(gou)內(nei),施放完畢,將電(dian)(dian)纜(lan)(lan)(lan)(lan)放于溝(gou)底或支(zhi)架(jia)上,并在電(dian)(dian)纜(lan)(lan)(lan)(lan)上綁扎電(dian)(dian)纜(lan)(lan)(lan)(lan)標(biao)牌。
42、電纜敷設的常用設備有哪些(xie)?
答:(1)空氣壓縮機,主要用來(lai)破(po)壞路面,為以后敷設電纜作準備(bei);
(2)電(dian)動(dong)卷(juan)揚機(ji)或電(dian)纜牽引機(ji),主要用來拖電(dian)纜;
(3)電纜輸送機,配合牽引機使用(yong)來克服巨大的(de)摩擦力,減輕對電纜的(de)損壞;
(4)電纜盤放(fang)線支架;
(5)滾輪(lun)裝置;
(6)防(fang)捻 ,減鋼絲繩(sheng)出現(xian)的扭曲;
(7)電纜盤制動裝(zhuang)置;
(8)張力計。
43、電(dian)(dian)纜溝中支架安裝距離(li)的(de)要求如何?答:電(dian)(dian)纜固定于(yu)(yu)電(dian)(dian)纜溝和(he)隧道(dao)的(de)墻上,水平裝置時(shi),當電(dian)(dian)纜外徑等于(yu)(yu)或小于(yu)(yu)50mm時(shi)應每隔(ge)(ge)1m加一支撐(cheng);外徑大于(yu)(yu)50mm的(de)電(dian)(dian)纜每隔(ge)(ge)0.6m加一支撐(cheng);排成三角形的(de)單電(dian)(dian)纜,每隔(ge)(ge)1m應用綁帶扎(zha)牢,垂直裝置時(shi),每隔(ge)(ge)1~1.5m加以固定。
44、如何(he)處理(li)電(dian)力電(dian)纜(lan)與(yu)控制電(dian)纜(lan)在(zai)同一托架(jia)的(de)安裝(zhuang)?
答:電(dian)力電(dian)纜與控制電(dian)纜一般不應(ying)敷(fu)設在同一托架內,當(dang)電(dian)纜較少而將控纜與電(dian)力電(dian)纜敷(fu)設在同一托架內時,應(ying)用隔板隔開(kai)。
45、電纜隧道內(nei)如何裝設接地線?
答:隧道和(he)溝的(de)(de)全長應裝設(she)連(lian)(lian)(lian)續(xu)的(de)(de)接(jie)地(di)線,接(jie)地(di)線應和(he)所有的(de)(de)支架相連(lian)(lian)(lian),兩頭和(he)接(jie)地(di)極連(lian)(lian)(lian)通。接(jie)地(di)線的(de)(de)規(gui)格(ge)應符合設(she)計(ji)要求。電纜(lan)鉛包(bao)和(he)鎧裝除了有絕緣要求外,應全部相互連(lian)(lian)(lian)接(jie)并和(he)接(jie)地(di)線相連(lian)(lian)(lian),電纜(lan)架和(he)接(jie)地(di)線均應涂防銹漆或(huo)鍍鋅。
46、對于電纜孔洞的防火封堵(du)有(you)何要求?
答:對于較大的(de)電(dian)纜貫穿孔洞(dong),如(ru)電(dian)纜貫穿樓(lou)板(ban)(ban)處等(deng),采用(yong)防火(huo)堵料(liao)(liao)封堵時,應根(gen)據實(shi)際情況,先在電(dian)纜表面涂四至六(liu)層防火(huo)涂料(liao)(liao),長(chang)度自孔洞(dong)以下(xia)1.5m左右,再用(yong)耐火(huo)材料(liao)(liao)加(jia)工成具有(you)一定強(qiang)度的(de)板(ban)(ban)托(tuo)防火(huo)堵料(liao)(liao),保(bao)證(zheng)封堵后牢(lao)固并便(bian)于更換電(dian)纜時拆裝,封堵密(mi)實(shi)無孔隙以有(you)效地堵煙堵火(huo)。
47、噴燈點火前應注意哪些檢查?
答:應進行下列各項檢查:
(1)打氣筒是(shi)否漏(lou)油(you)或滲(shen)油(you),油(you)桶及噴嘴(zui)處是(shi)否漏(lou)油(you)、漏(lou)氣;
(2)油(you)桶內的(de)油(you)量是否(fou)超過油(you)桶容(rong)量的(de)3/4,加油(you)的(de)螺絲塞(sai)是否(fou)擰(ning)緊。
48、使用噴燈應注意哪些(xie)事項?
答:(1)噴燈更大 注油量(liang)為油筒(tong)容積(ji)的3/4;
(2)開始(shi)打氣(qi)壓(ya)力不(bu)要太(tai)大,點燃后火焰由黃(huang)變藍即可使(shi)用;
(3)周圍不得有易燃物,空氣要流通(tong);
(4)停用時先關閉調節(jie)開關,火熄(xi)后,慢(man)慢(man)旋松油(you)孔蓋(gai)放氣(qi),空氣(qi)放完后,要(yao)(yao)要(yao)(yao)旋松調節(jie)開關,完全冷卻后再旋松孔蓋(gai);
(5)煤油噴(pen)燈(deng)(deng)與汽油噴(pen)燈(deng)(deng)要分開(kai)使用。
49、手動油壓(ya)鉗有(you)何(he)(he)用途(tu)?如何(he)(he)操作?
答:兩根(gen)導(dao)線的(de)連接通(tong)常是(shi)將(jiang)兩導(dao)線端穿入相(xiang)同材料(liao)制(zhi)成的(de)壓(ya)(ya)管中,用壓(ya)(ya)接鉗(qian)擠壓(ya)(ya)數個(ge)坑,使導(dao)線連接在一(yi)起(qi)(qi),壓(ya)(ya)接時(shi)(shi),手柄向(xiang)(xiang)上(shang)抬起(qi)(qi)時(shi)(shi),柱(zhu)(zhu)塞向(xiang)(xiang)外移(yi)(yi)動(dong)(dong),進(jin)油(you)閥(fa)(fa)下(xia)腔(qiang)產生真(zhen)空,油(you)箱內的(de)油(you)進(jin)入柱(zhu)(zhu)塞腔(qiang)。手柄下(xia)壓(ya)(ya)時(shi)(shi),柱(zhu)(zhu)塞向(xiang)(xiang)內移(yi)(yi)動(dong)(dong),油(you)受壓(ya)(ya)后,使進(jin)油(you)閥(fa)(fa)關閉,打開出油(you)閥(fa)(fa),使油(you)壓(ya)(ya)進(jin)入液壓(ya)(ya)缸,推(tui)動(dong)(dong)活(huo)塞和(he)陽(yang)模,陽(yang)、陰(yin)模之間放有(you)壓(ya)(ya)接管,當壓(ya)(ya)接被(bei)擠壓(ya)(ya)的(de)坑深到一(yi)定值時(shi)(shi),開啟回(hui)油(you)閥(fa)(fa),活(huo)塞自動(dong)(dong)返回(hui),壓(ya)(ya)完一(yi)個(ge)坑后,移(yi)(yi)動(dong)(dong)壓(ya)(ya)鉗(qian),再壓(ya)(ya)下(xia)一(yi)個(ge)。
50、常用低壓電力(li)電纜按絕緣和保護層的不同,主要可分(fen)為哪幾類?
答(da):(1)油浸紙絕緣鉛(qian)包(或鋁包)電力電纜;
(2)不滴流(liu)油浸紙絕緣電力電纜;
(3)聚(ju)氯乙(yi)烯(xi)絕緣(yuan)聚(ju)氯乙(yi)烯(xi)護(hu)套電力電纜;
(4)交(jiao)聯聚氯乙烯絕緣聚乙烯護套電(dian)(dian)力電(dian)(dian)纜;
(5)交聯(lian)聚氯(lv)乙(yi)烯絕緣聚氯(lv)乙(yi)烯護套電(dian)力電(dian)纜;
(6)橡皮絕緣電力(li)電纜。
51、常(chang)用(yong)絕緣材料的類別哪(na)些?舉(ju)例說明?
答:(1)無機絕緣材料:有云母、石(shi)棉、大理石(shi)、瓷器(qi)、玻璃等;
(2)有機(ji)絕(jue)緣材料:有樹脂、橡膠(jiao)、紙、麻、棉紗等;
(3)混合絕緣材(cai)料:用以(yi)上絕緣材(cai)料加工而成(cheng)型的名種(zhong)絕緣材(cai)料。
52、在哪種情況(kuang)下采(cai)用(yong)排管敷設?有什么優點(dian)?
答:排管敷設一(yi)般用(yong)在(zai)與其他建筑(zhu)物、公路(lu)或鐵路(lu)相(xiang)交叉的(de)地方(fang),有時也在(zai)建筑(zhu)物密集(ji)區內采用(yong)。主要優(you)點(dian)是占地少,能承受大的(de)荷重,電(dian)纜(lan)相(xiang)互間(jian)互不影響,比較安全(quan)。
53、何謂(wei)電纜長(chang)期允許載流量?
答:電纜長期(qi)允許載流量(liang)是指在(zai)電纜內通過(guo)規定(ding)電流時(shi),在(zai)熱穩定(ding)后,電纜導體達到(dao)長期(qi)允許工(gong)作(zuo)溫度時(shi)的(de)電流數值。
54、決定電纜長期允許載(zai)流量的因素(su)有哪些?
答:有(you)以下三個(ge)因素決(jue)定:
(1)電纜的長期容許工作溫(wen)度(du);
(2)電纜本身的散熱性能(neng);
(3)電(dian)纜(lan)裝置情況及周圍環境的散(san)熱(re)條(tiao)件。
55、電纜的(de)敷設(she)方式(shi)有幾種(zhong)?
答:有以下幾(ji)種:
(1)直埋在地下;
(2)安裝在電纜(lan)溝內;
(3)安裝在地下隧道(dao)內(nei);
(4)安裝在建筑物(wu)內部墻上(shang)或(huo)天棚上(shang);
(5)安(an)裝在橋(qiao)架(jia)上;
(6)敷設在排(pai)管內(nei);
(7)敷設在(zai)水底。
56、如(ru)何(he)進行電纜管的連接工作?
答:電纜管(guan)連(lian)接時,必須用扣和管(guan)接頭連(lian)接,如(ru)采用焊(han)接時,不(bu)能(neng)直接對焊(han),連(lian)接處要套上一段粗管(guan)再進行(xing)焊(han)接,以免焊(han)渣(zha)掉入管(guan)內。
57、制作電纜頭時(shi),對上下扳彎電纜芯線有(you)何要求?
答(da):扳彎線(xian)芯(xin)時,不得損傷(shang)紙絕緣,芯(xin)線(xian)的彎曲(qu)半徑(jing)不得小(xiao)(xiao)于電纜線(xian)芯(xin)的10倍。制作時要特(te)別(bie)小(xiao)(xiao)心(xin),應使線(xian)芯(xin)彎曲(qu)部分均勻(yun)受力,否則極易損傷(shang)絕緣紙。
58、簡述塑(su)料電纜的熱(re)收縮密封(feng)法。
答:熱(re)(re)縮(suo)(suo)法適用于中、低壓(ya)橡、塑電(dian)(dian)纜接頭和終(zhong)端頭的密(mi)封,也可(ke)適用于不滴流和黏性(xing)浸漬(zi)絕(jue)緣(yuan)電(dian)(dian)纜。采用交(jiao)聯聚乙烯型和硅橡膠型兩大類遇熱(re)(re)后(hou)能均勻收(shou)縮(suo)(suo)的熱(re)(re)收(shou)縮(suo)(suo)管(guan)。將這種管(guan)材套于預定(ding)的粘合密(mi)封部位,并(bing)在粘和部位涂上熱(re)(re)熔膠,當(dang)加熱(re)(re)到一定(ding)溫(wen)度后(hou),熱(re)(re)縮(suo)(suo)管(guan)將收(shou)縮(suo)(suo),同時熱(re)(re)熔膠熔化,待自(zi)然冷(leng)卻后(hou)即形(xing)成一道(dao)良好(hao)的密(mi)封封層。
59、用電(dian)動彎管機(ji)彎制電(dian)纜保護管時應注(zhu)意什么?
答:(1)彎管(guan)機(ji)應由了解其性能并熟悉(xi)操作(zuo)(zuo)知識的(de)人員操作(zuo)(zuo);
(2)使用前(qian)必(bi)須進行(xing)檢查,按鈕、操作把(ba)手(shou)、行(xing)程開關應(ying)完好,彎(wan)管機必(bi)須可靠接地;
(3)選用(yong)符(fu)合要(yao)求的(de)模具,確(que)定(ding)好所需(xu)要(yao)的(de)彎曲(qu)半徑;
(4)施工(gong)場地(di)周圍(wei),應有充(chong)足的(de)活動范圍(wei);
(5)使用時待空(kong)轉(zhuan)正常(chang)后,方可帶負荷工(gong)作(zuo),運(yun)行(xing)中,嚴禁用手腳接觸其轉(zhuan)動部分;
(6)工(gong)作完畢應及時停(ting)電,釋(shi)放油壓。
60、電纜清(qing)冊的(de)內容(rong)及電纜編(bian)號(hao)的(de)含義是什么?
答(da):電(dian)纜清冊是(shi)施(shi)(shi)放電(dian)纜和指(zhi)導施(shi)(shi)工的(de)依據,運(yun)行維(wei)護(hu)的(de)檔案資料。應(ying)列(lie)入每(mei)根(gen)電(dian)纜的(de)編號、起(qi)始點、型號、規格、長度(du),并分(fen)類統計出總長度(du),控纜還應(ying)列(lie)出每(mei)根(gen)電(dian)纜的(de)備用芯。
電(dian)纜(lan)編(bian)號是識別電(dian)纜(lan)的標志,故要(yao)求全廠編(bian)號不重復,并且有一(yi)定的含義和(he)規律(lv),能(neng)表達電(dian)纜(lan)的特征。
61、電(dian)纜目前采用(yong)的敷設方法(fa)可(ke)分為幾類?
答:(1)人工敷設,即采用人海戰(zhan)術,在一人或多(duo)人協(xie)調指揮(hui)下(xia),按(an)規定進行(xing)敷設;
(2)機(ji)械化敷設,即采用(yong)滾(gun)輪、牽引器(qi)、輸送機(ji),通過一同步電源進(jin)行控制,比較安全;
(3)人工(gong)和(he)機(ji)械相(xiang)結合,有些現場由(you)于(yu)轉彎(wan)較(jiao)多,施工(gong)難度大,全(quan)用(yong)機(ji)械較(jiao)困難,所以采用(yong)此法。
62、控制(zhi)二次回路接線應符合哪(na)些要求?
答:(1)按圖施工接線(xian)正確;
(2)導線(xian)的電氣連(lian)接應牢固可靠(kao);
(3)盤柜內的(de)導(dao)線(xian)不應有接(jie)頭,導(dao)線(xian)芯線(xian)應無損傷;
(4)電纜芯線端部(bu)應(ying)標明其(qi)回路編(bian)號,編(bian)號應(ying)正(zheng)確,字跡清晰且不(bu)易脫色;
(5)配線應(ying)整齊、清晰(xi)、美觀(guan),導線絕(jue)緣應(ying)良好、無損;
(6)每(mei)個接線(xian)端子的每(mei)側(ce)接線(xian)宜為一根,最多不(bu)得超過(guo)兩根。
63、電纜排管有(you)何要(yao)求?
答:(1)排管頂部至地面距(ju)離,在廠(chang)房內(nei)為(wei)0.2m,人行(xing)道下為(wei)0.5m,一般地區(qu)為(wei)0.7m;
(2)在變更方向及(ji)分支處(chu)均應裝(zhuang)置排(pai)管井坑,長度超過30mm時(shi)也應加設(she)井坑;
(3)井坑深度不(bu)小于(yu)0.8m,人(ren)孔(kong)直徑不(bu)小于(yu)0.7mm;
(4)排管應(ying)有傾向井(jing)坑0.5%~1%的排水坡度。
64、對于電纜導(dao)體連(lian)接點的電阻有何要求(qiu)?
答:要求連(lian)接點(dian)的電(dian)阻(zu)小(xiao)而(er)且穩定,連(lian)接點(dian)的電(dian)阻(zu)與(yu)相同長(chang)度、相同截(jie)面的導體(ti)之比值(zhi)(zhi),對(dui)于(yu)(yu)新(xin)安裝的終端頭(tou)(tou)和(he)中間頭(tou)(tou),應不大于(yu)(yu)1;對(dui)于(yu)(yu)運行(xing)中的終端頭(tou)(tou)和(he)中間頭(tou)(tou)這個比值(zhi)(zhi)不應大于(yu)(yu)1.2。
65、電(dian)纜接(jie)頭和中間(jian)頭的設(she)計應滿足哪些要求?
答:應(ying)滿足的要(yao)求(qiu)有(you):
(1)耐壓強度高,導(dao)體連接好(hao);
(2)機械強度大,介質損失小;
(3)結構簡單,密封(feng)性強。
66、什么是電纜故障?有(you)幾種(zhong)常見的類型?
答:電纜(lan)故(gu)障是指(zhi)電纜(lan)在(zai)預防性試驗時(shi)發生(sheng)絕緣擊(ji)穿或在(zai)運行中,因絕緣擊(ji)穿、導線燒斷等而迫使電纜(lan)線路停電的故(gu)障。常見(jian)的故(gu)障有接地故(gu)障、短路故(gu)障、斷線故(gu)障、閃絡(luo)性故(gu)障和混合型故(gu)障等。
67、如何處理電纜線路的(de)單(dan)相接地故障?
答:電(dian)纜線路單(dan)相接地故(gu)障一般(ban)(ban)來說,電(dian)纜導(dao)體的(de)(de)損(sun)傷(shang)只是局部的(de)(de),如果屬于(yu)機械(xie)損(sun)傷(shang),而故(gu)障點(dian)附近(jin)的(de)(de)土壤又較干燥時,一般(ban)(ban)可進行局部修理,加添一只假接頭,即不將電(dian)纜芯鋸斷,僅將故(gu)障點(dian)絕(jue)緣加強后密封即可。
68、電(dian)力電(dian)纜在(zai)敷設前應進(jin)行哪些試驗和檢(jian)查?
答:敷設前(qian)應檢(jian)查電纜的型(xing)號、規格及長度是(shi)否符合要求,是(shi)否有外(wai)力(li)損傷,低(di)壓(ya)電纜用(yong)1000V兆歐表(biao)遙測絕緣電阻,阻值一(yi)般(ban)不(bu)低(di)于10MΩ,高(gao)壓(ya)電纜用(yong)2500V兆歐表(biao)搖測阻值一(yi)般(ban)不(bu)抵于400MΩ。
69、主廠房內敷設電纜時一般(ban)應注意什么?
答:在主廠房內敷(fu)設電纜時一般(ban)應注意:
(1)凡引至集(ji)控室(shi)的(de)控制電纜(lan)宜架空敷設;
(2)6KV電纜(lan)宜(yi)用隧(sui)道或排管(guan)敷設,地(di)下水(shui)位高(gao)處亦可架(jia)空或用排管(guan)敷設;
(3)380V電纜當兩端電纜在零米(mi)時宜用(yong)隧(sui)道、溝或排管,當一端設(she)備在上(shang)、一端在下時,可(ke)部分(fen)架空(kong)敷設(she),當地下水位較高時,宜架空(kong)。
70、電力電纜的內屏蔽層與外(wai)屏蔽層各在(zai)什么(me)部位?采用(yong)什么(me)材料(liao)?有(you)何(he)作用(yong)?
答:為了(le)使(shi)絕(jue)緣層(ceng)和電(dian)纜(lan)導(dao)(dao)體(ti)有較好的(de)接觸,消除導(dao)(dao)體(ti)表(biao)面的(de)不光滑引起(qi)的(de)導(dao)(dao)體(ti)表(biao)面電(dian)場(chang)強度(du)的(de)增加,一般(ban)在導(dao)(dao)體(ti)表(biao)面包(bao)有金屬(shu)化紙或半導(dao)(dao)體(ti)紙帶的(de)內(nei)屏蔽層(ceng)。為了(le)使(shi)絕(jue)緣層(ceng)和金屬(shu)護套(tao)有較好的(de)接觸,一般(ban)在絕(jue)緣層(ceng)外(wai)表(biao)面包(bao)有外(wai)層(ceng)屏蔽層(ceng)。外(wai)屏層(ceng)與內(nei)屏層(ceng)的(de)材料相同,有時還外(wai)扎銅帶或編織銅絲帶。
71、簡述環氧樹脂復合物的構成及性能。
答:環氧樹脂(zhi)復合物(wu)由環氧樹脂(zhi)加入硬化(hua)劑(ji)、填充劑(ji)增韌劑(ji)和稀(xi)釋劑(ji)組成。具有(you)以下(xia)性能:
(1)有足夠(gou)的機械強(qiang)度;
(2)電氣性(xing)能優良;
(3)電氣性能穩定(ding);
(4)與有色金(jin)屬有足夠的黏附(fu)力;
(5)耐腐(fu)蝕性好;
(6)戶外使用時(shi),耐雨、耐光(guang)、耐濕熱(re)。
72、單(dan)芯電纜護套一端接地方式中為(wei)什么必須安裝一條沿電纜平行敷設的回流線(xian)?
答:在金屬(shu)護套(tao)一端接(jie)地(di)的(de)(de)電(dian)纜線(xian)路中(zhong)(zhong),為(wei)(wei)確保護套(tao)中(zhong)(zhong)的(de)(de)感應電(dian)壓不超過允許標準(zhun),必須安(an)裝一條沿電(dian)纜線(xian)路平(ping)行敷設(she)的(de)(de)導(dao)體,且(qie)導(dao)體的(de)(de)兩端接(jie)地(di),這種導(dao)體稱為(wei)(wei)回(hui)(hui)流(liu)(liu)線(xian)。當發生單(dan)相接(jie)地(di)故障時(shi),接(jie)地(di)短路電(dian)流(liu)(liu)可(ke)以通(tong)過回(hui)(hui)流(liu)(liu)線(xian)流(liu)(liu)回(hui)(hui)系(xi)統中(zhong)(zhong)心點,由于(yu)通(tong)過回(hui)(hui)流(liu)(liu)線(xian)的(de)(de)接(jie)地(di)電(dian)流(liu)(liu)產生的(de)(de)磁通(tong)抵消了一部分電(dian)纜導(dao)線(xian)接(jie)地(di)電(dian)流(liu)(liu)所(suo)產生的(de)(de)磁通(tong),因而可(ke)降低短路故障時(shi)護套(tao)的(de)(de)感應電(dian)壓。
73、電(dian)纜工程可(ke)劃(hua)分為幾(ji)個項目?
答:(1)工地運(yun)輸(shu):包括工程材料從(cong)倉庫到施工點的裝卸、運(yun)輸(shu)和空車(che)回程。
(2)地方(fang)工程:包(bao)括路面開挖、隧、溝道施(shi)工等。
(3)敷(fu)設(she)(she)工程:包括敷(fu)設(she)(she)、中間頭制作、掀蓋板、埋管、校潮、牽(qian)引(yin)頭制作等。
(4)兩端工程(cheng):包括支、吊橋架和(he)其基礎的制作安裝(zhuang),終端頭(tou)制作,油壓力和(he)信號裝(zhuang)置的安裝(zhuang),名種電氣性能測試(shi)等。
(5)塞(sai)(sai)止工程:包(bao)括充(chong)油電纜塞(sai)(sai)止頭制作,供油箱、自(zi)動排水(shui)及(ji)信號裝置(zhi)的安裝等(deng)。
(6)接(jie)(jie)地(di)工程(cheng):包括(kuo)絕緣(yuan)接(jie)(jie)頭(tou)、換位箱(xiang)、保護器、接(jie)(jie)地(di)箱(xiang)安裝(zhuang)等。
74、電纜線路的驗(yan)收(shou)應進(jin)行哪(na)些檢查?
答(da):(1)電纜規格應符(fu)合規定,排(pai)列(lie)應整(zheng)齊,無損傷,標牌齊全、正確、清(qing)晰;
(2)電纜的固(gu)定彎曲半(ban)徑、有關距(ju)離及(ji)單芯(xin)電力電纜的金屬護(hu)層的接(jie)線應符合要求;
(3)電(dian)纜終(zhong)端、中(zhong)間頭不滲漏(lou)油(you),安裝牢固,充(chong)油(you)電(dian)纜油(you)壓及表計整(zheng)定(ding)值應符合要(yao)求(qiu);
(4)接地良好;
(5)電纜終端相色正確(que),支架(jia)等的金屬部(bu)件油漆完整(zheng);
(6)電纜溝及隧道(dao)內(nei)、橋架上應無雜物(wu),蓋板(ban)齊全。
75、電纜線路(lu)正序阻抗(kang)測量過程中有什么要求?
答:電纜導體的(de)交流電阻和電纜三相同(tong)感(gan)抗(kang)的(de)相量和稱(cheng)為正序(xu)阻抗(kang)。
電(dian)(dian)纜線路(lu)的(de)(de)(de)正序阻抗一般(ban)(ban)可在電(dian)(dian)纜盤上(shang)直接(jie)測量(liang),測量(liang)時一般(ban)(ban)使用較(jiao)低(di)的(de)(de)(de)電(dian)(dian)壓(ya)(ya),因此,需要用降壓(ya)(ya)變壓(ya)(ya)器進行(xing)降壓(ya)(ya),降壓(ya)(ya)器采(cai)用星形接(jie)線,容(rong)量(liang)一般(ban)(ban)為10kVA以上(shang),有較(jiao)廣(guang)的(de)(de)(de)電(dian)(dian)壓(ya)(ya)調節范圍,測量(liang)時交流(liu)(liu)電(dian)(dian)源應(ying)比較(jiao)穩定(ding)(ding),以保證(zheng)測量(liang)時電(dian)(dian)流(liu)(liu)達到(dao)規定(ding)(ding)的(de)(de)(de)要求,實際(ji)電(dian)(dian)壓(ya)(ya)表的(de)(de)(de)讀數值(zhi)必須是電(dian)(dian)纜端(duan)的(de)(de)(de)電(dian)(dian)壓(ya)(ya),試驗電(dian)(dian)流(liu)(liu)更好(hao) 接(jie)近電(dian)(dian)纜長(chang)期允許載流(liu)(liu)量(liang),測讀各表計的(de)(de)(de)數值(zhi)時,合上(shang)電(dian)(dian)流(liu)(liu)后同時讀取(qu)三個表的(de)(de)(de)數值(zhi)。
76、根據《電(dian)業生產安(an)全規定》,電(dian)氣(qi)工作(zuo)人員必須(xu)具(ju)備的條(tiao)件是什(shen)么?
答:必須具(ju)備下列(lie)條件:
(1)經醫生(sheng)鑒定身體健康(kang),無妨(fang)礙(ai)工作的病癥;
(2)具備必要的(de)電氣知識,按其職務和工作性質(zhi)掌握相(xiang)關的(de)規程(cheng)、專業技(ji)術(shu)及安(an)全操作技(ji)術(shu),并(bing)經考試合格;
(3)熟練掌握觸(chu)電急(ji)救方法。
77、電纜在運(yun)輸裝卸(xie)過程中(zhong)應注(zhu)意什么?
答:(1)在運輸(shu)裝卸過(guo)程中,不應使電纜及電纜盤受到損傷(shang),嚴禁(jin)將電纜盤直(zhi)接由車上推(tui)下,電纜般不應平放運輸(shu),平放貯存(cun)。
(2)運輸或滾(gun)動電(dian)纜(lan)(lan)盤前(qian),必須保證電(dian)纜(lan)(lan)盤牢固,電(dian)纜(lan)(lan)繞(rao)緊、充油(you)電(dian)纜(lan)(lan)至壓力油(you)箱(xiang)間的(de)油(you)管應(ying)固定,不(bu)得損傷,壓力油(you)箱(xiang)應(ying)牢固,壓力指示應(ying)符合要(yao)求(qiu)。
78、電纜防火(huo)有哪些(xie)措(cuo)施(shi)?
答:(1)采用阻燃電纜(lan);
(2)采用防火電纜托(tuo)架;
(3)采用(yong)防(fang)火涂(tu)料;
(4)電纜隧道、夾層出口等(deng)處設置防火隔墻、防火擋(dang)板(ban);
(5)架(jia)空電(dian)纜應避開油管道、防(fang)爆門(men),否則應有要取局部穿(chuan)管或(huo)隔熱(re)防(fang)火措施。
79、選擇(ze)電力(li)電纜的(de)截(jie)面(mian)應從哪幾(ji)個(ge)方面(mian)考(kao)慮?
答(da):應考慮如下(xia)幾個方面:
(1)電纜長期允(yun)許通過的工作(zuo)電流;
(2)一旦短路時(shi)的熱穩定性;
(3)線(xian)路上的(de)電壓降不(bu)能超出允許工作(zuo)范圍。
80、電力電纜和架空線(xian)比較有(you)哪(na)些優(you)點?
答:(1)運行可靠,由于安(an)裝在地下等隱(yin)蔽(bi)處,受(shou)外力破壞小(xiao),發生(sheng)故障的(de)機會(hui)較少(shao),供電(dian)安(an)全(quan),不會(hui)給人身造成危害;
(2)維護工(gong)作量(liang)小,不需頻(pin)繁的巡檢;
(3)不需架設桿塔;
(4)有助于(yu)提高功率因數。