1、常(chang)用的電線(xian)、電纜(lan)按(an)用途分有哪些種類?
答:按用途可分為(wei)裸(luo)導線、絕緣電(dian)(dian)(dian)線、耐熱電(dian)(dian)(dian)線、屏蔽電(dian)(dian)(dian)線、電(dian)(dian)(dian)力電(dian)(dian)(dian)纜、控制電(dian)(dian)(dian)纜、通信(xin)電(dian)(dian)(dian)纜、射頻(pin)電(dian)(dian)(dian)纜等。
2、絕緣電(dian)線(xian)有哪幾(ji)種?
答:常有的絕(jue)(jue)緣(yuan)電(dian)(dian)線(xian)有以下(xia)(xia)幾種:聚氯乙烯(xi)絕(jue)(jue)緣(yuan)電(dian)(dian)線(xian)、聚氯乙烯(xi)絕(jue)(jue)緣(yuan)軟(ruan)線(xian)、丁腈聚氯乙烯(xi)混合物絕(jue)(jue)緣(yuan)軟(ruan)線(xian)、橡(xiang)皮絕(jue)(jue)緣(yuan)電(dian)(dian)線(xian)、農用地下(xia)(xia)直埋鋁芯塑料(liao)絕(jue)(jue)緣(yuan)電(dian)(dian)線(xian)、橡(xiang)皮絕(jue)(jue)緣(yuan)棉紗紡(fang)織軟(ruan)線(xian)、聚氯乙烯(xi)絕(jue)(jue)緣(yuan)尼龍護(hu)套(tao)電(dian)(dian)線(xian)、電(dian)(dian)力(li)和照明用聚氯乙烯(xi)絕(jue)(jue)緣(yuan)軟(ruan)線(xian)等。
3、電纜橋架適合于何(he)種(zhong)場合?
答:電(dian)纜橋架適(shi)用(yong)于一般工礦企業室(shi)內(nei)外架空敷(fu)設電(dian)力(li)電(dian)纜、控制(zhi)電(dian)纜,亦可用(yong)于電(dian)信、廣播電(dian)視(shi)等部門在室(shi)內(nei)外架設。
4、電纜附(fu)件(jian)有哪些(xie)?
答:常用的電(dian)(dian)附(fu)件有電(dian)(dian)纜終端接線(xian)盒、電(dian)(dian)纜中(zhong)間接線(xian)盒、連接管及接線(xian)端子、鋼板接線(xian)槽、電(dian)(dian)纜橋(qiao)架等。
5、什么叫電纜中間接頭?
答:連接(jie)電纜與電纜的導體、絕緣屏蔽(bi)層和保護(hu)層,以使電纜線路連接(jie)的裝置,稱(cheng)為電纜中間接(jie)頭。
6、什么叫電氣主接(jie)線?
答:電(dian)氣主(zhu)接線(xian)是發電(dian)廠、變電(dian)所中(zhong)主(zhu)要電(dian)氣設備和母線(xian)的(de)連接方式,包(bao)括(kuo)主(zhu)母線(xian)和廠用電(dian)系統按(an)一定(ding)的(de)功能要求的(de)連接方式。
7、在選擇電力(li)電纜的(de)截面時(shi),應遵照哪些規(gui)定?
答:電力電纜(lan)(lan)的(de)(de)(de)選(xuan)擇(ze)應(ying)(ying)(ying)遵照以(yi)下(xia)原則(ze):(1)電纜(lan)(lan)的(de)(de)(de)額(e)定(ding)電壓要(yao)大(da)(da)于或等于安裝點供電系統的(de)(de)(de)額(e)定(ding)電壓;(2)電纜(lan)(lan)持續(xu)容許電流(liu)應(ying)(ying)(ying)等于或大(da)(da)于供電負(fu)載(zai)的(de)(de)(de)更大(da)(da) 持續(xu)電流(liu);(3)線芯截面要(yao)滿足供電系統短路時的(de)(de)(de)穩定(ding)性的(de)(de)(de)要(yao)求;(4)根據(ju)電纜(lan)(lan)長度驗算電壓降(jiang)是否符合要(yao)求;(5)線路末端的(de)(de)(de)最小短路電流(liu)應(ying)(ying)(ying)能使保護裝置(zhi)可靠的(de)(de)(de)動作(zuo)。
8、交聯聚乙烯電纜(lan)和油紙電纜(lan)比較有(you)哪些(xie)優點?
答:(1)易安裝,因為(wei)它(ta)允(yun)許(xu)最小彎曲半(ban)徑小、且重量輕;(2)不受線路(lu)落差*;(3)熱性能好(hao),允(yun)許(xu)工作溫度高、傳輸容量大;(4)電纜附件簡(jian)單,均為(wei)干式結構;(5)運行維護簡(jian)單,無漏(lou)油問題;(6)價格較(jiao)低;(7)可靠(kao)性高、故障率低;(8)制(zhi)造工序少(shao)、工藝(yi)簡(jian)單,經濟效(xiao)益顯著。
9、固(gu)定(ding)交流(liu)單(dan)芯(xin)電纜的夾具有什(shen)么要求?為(wei)什(shen)么?
答(da):夾具應無鐵件(jian)構成(cheng)閉合磁(ci)路,這是因為(wei)當電(dian)纜線芯(xin)通過(guo)電(dian)流(liu)(liu)時,在(zai)其周圍產(chan)生磁(ci)力線,磁(ci)力線與通過(guo)線芯(xin)的電(dian)流(liu)(liu)大小成(cheng)正比,若使用(yong)鐵件(jian)等導磁(ci)材料,根(gen)據電(dian)磁(ci)感應可(ke)知,將(jiang)在(zai)鐵件(jian)中產(chan)生渦(wo)流(liu)(liu)使電(dian)纜發熱,甚至燒壞(huai)電(dian)纜。所以不可(ke)使用(yong)鐵件(jian)作(zuo)單芯(xin)交流(liu)(liu)電(dian)纜的固(gu)定夾具。
10、以下的(de)熱(re)縮電纜頭的(de)附件(jian)的(de)更(geng)大 特點(dian)和優(you)點(dian)是什么?
答(da):熱縮附件的更大 特(te)點是用應力管代(dai)替(ti)傳統的應力錐(zhui),它不(bu)僅簡(jian)化了施工工藝,還縮小了接(jie)頭的終(zhong)端的尺寸,安裝方便,省時省工,性能(neng)優(you)越,節約(yue)金屬。熱縮電纜附件集灌注式和干(gan)包式為一體,集合了這兩種附件的優(you)點。
11、電纜敷設前應進(jin)行哪(na)些檢(jian)查工(gong)作?
答(da):(1)支架(jia)應(ying)(ying)(ying)齊全、油(you)(you)漆(qi)完整。(2)電(dian)(dian)(dian)纜(lan)(lan)(lan)型(xing)號(hao)、電(dian)(dian)(dian)壓(ya)、規格符合設計。(3)電(dian)(dian)(dian)纜(lan)(lan)(lan)絕緣(yuan)良好,當(dang)對油(you)(you)紙電(dian)(dian)(dian)纜(lan)(lan)(lan)的密封有懷疑時,應(ying)(ying)(ying)進行受潮判斷;直埋電(dian)(dian)(dian)纜(lan)(lan)(lan)與小(xiao)底電(dian)(dian)(dian)纜(lan)(lan)(lan)應(ying)(ying)(ying)經直流耐(nai)壓(ya)試難(nan)合格;充(chong)油(you)(you)電(dian)(dian)(dian)纜(lan)(lan)(lan)的油(you)(you)樣(yang)應(ying)(ying)(ying)試驗合格。(4)充(chong)油(you)(you)電(dian)(dian)(dian)纜(lan)(lan)(lan)的油(you)(you)壓(ya)不宜低于1.47MPa。
11、交聯熱(re)收縮電纜附(fu)件有(you)哪些優(you)點?
答:這是一種新型(xing)材(cai)料(liao),它與現在其他類型(xing)附件(jian)比較具(ju)有電氣性能優(you)越(yue)、體積小(xiao)、質(zhi)量小(xiao)、安裝簡便、材(cai)料(liao)配套等優(you)點,另外還具(ju)有耐(nai)氣候、抗污穢性、阻燃自熄等能力。
12、對油紙絕(jue)緣(yuan)(yuan)電力電纜密封有懷疑時,如何用較簡單的辦(ban)法檢(jian)查電纜絕(jue)緣(yuan)(yuan)紙是否受潮(chao)?
答:把電纜(lan)絕緣紙點燃或(huo)放入(ru)150℃左右的電纜(lan)油中檢查(cha),無“嘶嘶”聲(sheng)或(huo)白色泡沫出現,說明未受(shou)潮。
13、電纜(lan)標(biao)志牌應注明(ming)什么內容?編寫有(you)何要求?
答:標志牌上(shang)應注明電(dian)纜(lan)線(xian)路(lu)設計編(bian)號(hao)(hao)、電(dian)纜(lan)型號(hao)(hao)、規格及始(shi)點,并聯使用的(de)電(dian)纜(lan)應有順序號(hao)(hao)。要求字跡清晰、不易脫落(luo)。
14、直埋電纜的(de)方位標(biao)志(zhi)應(ying)設置(zhi)在哪些位置(zhi)?
答:在電纜兩端,電纜直線段(duan)50~100m處(chu)電纜接頭幾電纜改變(bian)方向的彎角(jiao)處(chu)。
15、制(zhi)作電纜接頭用的(de)黃(huang)臘綢帶(dai)、黑玻(bo)璃漆帶(dai)、無(wu)堿玻(bo)璃絲帶(dai)等,施工前如何進行排潮(chao)處理?
答(da):(1)恒(heng)(heng)溫(wen)干燥(zao)法(fa):將絕緣(yuan)帶卷成直徑為25~30mm小卷,放入110~120℃恒(heng)(heng)溫(wen)干燥(zao)箱內(nei)烘4~5h,冷卻干取(qu)出,放入干燥(zao)的(de)密封筒內(nei)。(2)油浸排(pai)潮法(fa):將絕緣(yuan)帶小卷放入恒(heng)(heng)溫(wen)在(zai)120~130℃的(de)電纜(lan)油中,離鍋底保持30mm距離,經一定時(shi)間后油面不再產生泡沫后取(qu)出,裝(zhuang)入貯有(you)電纜(lan)油的(de)桶中,油位(wei)應(ying)超過所有(you)裝(zhuang)入的(de)物體并將其密封。
16、電纜(lan)外護層的作用是(shi)什么?
答:保護內護層不受(shou)機械(xie)損(sun)傷和化(hua)學腐蝕,增強機械(xie)強度。
17、室外電纜溝應符合哪(na)些要求?
答:電纜溝上部(bu)應比地面(mian)稍高,加蓋用(yong)混凝土制(zhi)作的蓋板,電纜應平(ping)敷在支架(jia)上,有(you)良好(hao)的排水管。
18、電纜內護層的作用是什么?
答;使絕緣(yuan)層不會與水、空氣或其他物體接(jie)觸,防(fang)止絕緣(yuan)受潮(chao)和(he)絕緣(yuan)層不受機械傷害(hai)。
19、使用鋼絲鉗時應注(zhu)意些(xie)什么?
答:使(shi)用(yong)前(qian),一定要檢查絕(jue)緣柄的絕(jue)緣是否完好無損,使(shi)用(yong)時不(bu)可用(yong)鋼絲鉗剪切超過規格(ge)所允(yun)許的金屬(shu)線材,并禁(jin)止(zhi)用(yong)鋼絲鉗代替錘子(zi)敲打(da)工具,以免損壞。
20、什么叫絕緣強度?
答:絕緣(yuan)物質(zhi)在電場(chang)中,當電場(chang)強(qiang)度(du)增(zeng)大到某(mou)一極限時(shi)就(jiu)會被擊穿,這個導致絕緣(yuan)擊穿的電場(chang)強(qiang)度(du)稱為絕緣(yuan)強(qiang)度(du)。
22、對電纜(lan)導體(ti)連(lian)接點的機械(xie)強度有(you)何要(yao)求?
答:連(lian)接(jie)(jie)點(dian)的(de)機械強(qiang)度,一(yi)般低(di)于電(dian)(dian)纜導(dao)體(ti)本身的(de)抗(kang)(kang)拉(la)(la)強(qiang)度,對于固定敷設的(de)電(dian)(dian)力電(dian)(dian)纜,其(qi)連(lian)接(jie)(jie)點(dian)的(de)抗(kang)(kang)拉(la)(la)強(qiang)度要求(qiu)不低(di)于導(dao)體(ti)本身抗(kang)(kang)拉(la)(la)強(qiang)度的(de)60%。
23、電力電纜的絕緣層材(cai)料應具備哪些主要性能?
答;應具(ju)備(bei)下列主要性能:(1)高(gao)的(de)(de)擊穿強度(du);(2)低的(de)(de)介質損耗;(3)相當高(gao)的(de)(de)絕緣(yuan)電阻(zu);(4)優良的(de)(de)耐放電性能;(5)具(ju)有一定的(de)(de)柔(rou)軟(ruan)性和機械強度(du);(6)絕緣(yuan)性能長期穩定。
24、機(ji)械(xie)敷設(she)電纜(lan)時,牽引(yin)強度有何規定?
答:對(dui)于(yu)銅芯(xin)電(dian)(dian)纜,當牽(qian)(qian)(qian)(qian)引(yin)頭部(bu)時,允(yun)許牽(qian)(qian)(qian)(qian)引(yin)強(qiang)度為70N/cm;對(dui)于(yu)鋁芯(xin)電(dian)(dian)纜,當牽(qian)(qian)(qian)(qian)引(yin)頭部(bu)時,允(yun)許牽(qian)(qian)(qian)(qian)引(yin)強(qiang)度為40N/cm;若利(li)用鋼絲網套牽(qian)(qian)(qian)(qian)引(yin)時,鉛(qian)護套電(dian)(dian)纜允(yun)許強(qiang)度為10N/cm;鉛(qian)護套電(dian)(dian)纜為40N/cm。
25、對電(dian)纜保護管有何規定?
答:(1)電纜(lan)需要穿(chuan)保(bao)護管(guan)(guan)敷設時(shi),管(guan)(guan)子內徑(jing)不應(ying)小(xiao)于(yu)電纜(lan)外徑(jing)的(de)1.5倍(bei),混(hun)凝(ning)土(tu)管(guan)(guan)、陶(tao)土(tu)管(guan)(guan)、石(shi)棉、水泥管(guan)(guan)的(de)內徑(jing)不應(ying)小(xiao)于(yu)100mm;
(2)電(dian)纜管的彎曲半(ban)(ban)徑應符合所穿入電(dian)纜彎曲半(ban)(ban)徑的規定;
(3)每根管子最多(duo)不(bu)應(ying)超過三(san)個彎(wan)(wan)頭,直角彎(wan)(wan)不(bu)應(ying)多(duo)于2個。
26、如何測量電(dian)纜護套的(de)外徑(jing)?
答:在護(hu)(hu)套圓周上均(jun)勻分布的五點處,測量護(hu)(hu)套外(wai)徑(jing)(jing)和其(qi)平均(jun)值(zhi),其(qi)平均(jun)外(wai)徑(jing)(jing)既為護(hu)(hu)套的外(wai)徑(jing)(jing)。
27、不同截(jie)面的銅芯(xin)電纜(lan)如何連(lian)接(jie)?
答:不同(tong)截(jie)面的銅(tong)芯電纜連接(jie)(jie),可采用開口弱背銅(tong)接(jie)(jie)管,以錫焊法連接(jie)(jie),也可用純銅(tong)棒按不同(tong)的截(jie)面要求連接(jie)(jie)成銅(tong)接(jie)(jie)管,以壓接(jie)(jie)法連接(jie)(jie)。
28、簡述10KV交(jiao)聯電纜熱(re)縮式制作戶內終(zhong)端頭的過(guo)程?
答;(1)準備階段:檢(jian)查(cha)熱縮電纜(lan)(lan)附(fu)件是否(fou)齊備,型號是否(fou)相配(pei),檢(jian)查(cha)并(bing)確認電纜(lan)(lan)有無潮氣后,檢(jian)查(cha)電纜(lan)(lan)。
(2)切除多余電(dian)纜(lan),根(gen)據現場情況(kuang)決定電(dian)纜(lan)長(chang)度(du)。
(3)剝(bo)除(chu)護(hu)層。
(4)焊接(jie)(jie)接(jie)(jie)地線,將接(jie)(jie)地線焊接(jie)(jie)在鋼(gang)帶(dai)上。
(5)填充三叉口及繞包密封膠。
(6)安裝三芯分(fen)支護(hu)套(tao)(tao),將(jiang)護(hu)套(tao)(tao)套(tao)(tao)入根(gen)部(bu),從中部(bu)開始(shi)收(shou)縮,先往根(gen)部(bu),再往指部(bu)。
(7)剝銅(tong) 帶(dai)和(he)外半導電層(ceng),剝切(qie)三芯(xin)分(fen)支套口20mm以上的銅(tong)帶(dai),嚴禁損傷主絕緣,清除干凈半導電層(ceng)。
(8)安裝應(ying)力管,管口端部分支套(tao)對接(jie)后熱縮。
(9)安裝接線端子。
(10)安裝絕(jue)緣管。
(11)安裝密封管。
(12)核相(xiang)后安裝(zhuang)相(xiang)色管。
29、戶內、戶外預制(zhi)式終端安(an)裝步(bu)驟有(you)哪些?
答:(1) 將(jiang)電纜按預定(ding)位(wei)(wei)置就位(wei)(wei)、固定(ding)、清(qing)潔表(biao)面,參照說(shuo)明書剝除外(wai)(wai)護(hu)套,如有(you)特(te)殊需要(yao),外(wai)(wai)護(hu)套剝切長度可調整(zheng),分別由銅帶、外(wai)(wai)護(hu)套鎧裝引出2組(zu)地線。
(2) 由外護套(tao)口向(xiang)上量取(qu)(qu)需要尺(chi)寸(cun)(cun),切除多(duo)余電(dian)纜(lan),套(tao)入熱縮三指套(tao)至三叉口根部由中間加熱收縮,由指套(tao)上口向(xiang)上量取(qu)(qu)規(gui)定尺(chi)寸(cun)(cun)(35kv為350~380mm)。去(qu)掉(diao)多(duo)余銅帶(保留20mm),再保留半導體預定位置,壓接出線端子密封。
30、電線電纜的應用主要分為三大類 :
(1)、電力系統
電(dian)(dian)(dian)(dian)(dian)力系統采(cai)用(yong)的電(dian)(dian)(dian)(dian)(dian)線(xian)電(dian)(dian)(dian)(dian)(dian)纜產品主要有架空裸(luo)電(dian)(dian)(dian)(dian)(dian)線(xian)、匯流排(母線(xian))、電(dian)(dian)(dian)(dian)(dian)力電(dian)(dian)(dian)(dian)(dian)纜(塑料線(xian)纜、油紙(zhi)力纜(基本被塑料電(dian)(dian)(dian)(dian)(dian)力電(dian)(dian)(dian)(dian)(dian)纜代(dai)替)、橡套(tao)線(xian)纜、架空絕緣(yuan)電(dian)(dian)(dian)(dian)(dian)纜)、分支(zhi)電(dian)(dian)(dian)(dian)(dian)纜(取(qu)代(dai)部分母線(xian))、電(dian)(dian)(dian)(dian)(dian)磁(ci)線(xian)以及(ji)電(dian)(dian)(dian)(dian)(dian)力設備(bei)用(yong)電(dian)(dian)(dian)(dian)(dian)氣裝備(bei)電(dian)(dian)(dian)(dian)(dian)線(xian)電(dian)(dian)(dian)(dian)(dian)纜等(deng)。
(2)、信息傳輸(shu)系(xi)統
用于信息傳輸系(xi)統的電(dian)(dian)(dian)線(xian)電(dian)(dian)(dian)纜(lan)(lan)主要有市話(hua)電(dian)(dian)(dian)纜(lan)(lan)、電(dian)(dian)(dian)視(shi)電(dian)(dian)(dian)纜(lan)(lan)、電(dian)(dian)(dian)子線(xian)纜(lan)(lan)、射頻(pin)電(dian)(dian)(dian)纜(lan)(lan)、光纖(xian)纜(lan)(lan)、數據電(dian)(dian)(dian)纜(lan)(lan)、電(dian)(dian)(dian)磁線(xian)、電(dian)(dian)(dian)力(li)通(tong)訊或(huo)其他復(fu)合電(dian)(dian)(dian)纜(lan)(lan)等。
(3)、機械設(she)備、儀器儀表系(xi)統
此部分除架空裸電線外幾乎其他所有產品(pin)均有應(ying)用,但主要(yao)是(shi)電力電纜、電磁線、數據電纜、儀(yi)器儀(yi)表線纜等。
31、電線電纜產品主要分為五大類(lei):
(1)、裸電線(xian)及裸導體制品(pin)(pin) 本類產品(pin)(pin)的(de)主要(yao)特征(zheng)是(shi):純的(de)導體金屬,無絕(jue)緣及護套層,如鋼(gang)芯鋁(lv)絞(jiao)線(xian)、銅(tong)鋁(lv)匯流排(pai)、電力(li)機車線(xian)等;加(jia)工工藝主要(yao)是(shi)壓力(li)加(jia)工,如熔煉(lian)、壓延、拉制、絞(jiao)合/緊壓絞(jiao)合等;產品(pin)(pin)主要(yao)用(yong)在城郊、農村、用(yong)戶主線(xian)、開關柜(ju)等。
(2)、電(dian)(dian)力電(dian)(dian)纜(lan)本類產品主要特征是:在導(dao)體(ti)外擠(繞)包絕(jue)緣(yuan)層(ceng)(ceng),如(ru)架(jia)空(kong)絕(jue)緣(yuan)電(dian)(dian)纜(lan),或(huo)幾芯(xin)絞合(he)(對(dui)應電(dian)(dian)力系統的(de)相線、零線和地線),如(ru)二芯(xin)以上架(jia)空(kong)絕(jue)緣(yuan)電(dian)(dian)纜(lan),或(huo)再增加護套層(ceng)(ceng),如(ru)塑料/橡套電(dian)(dian)線電(dian)(dian)纜(lan)。主要的(de)工(gong)藝技術有(you)拉制(zhi)、絞合(he)、絕(jue)緣(yuan)擠出(繞包)、成纜(lan)、鎧裝、護層(ceng)(ceng)擠出等(deng),各種(zhong)產品的(de)不(bu)同工(gong)序組合(he)有(you)一定區別。
產品主要用在發、配(pei)、輸(shu)(shu)、變(bian)、供電線路中的強(qiang)電電能傳(chuan)輸(shu)(shu),通(tong)過(guo)的電流大(幾十安至(zhi)幾千安)、電壓高(220V至(zhi)500kV及以上)。
(3)、電氣裝備(bei)用(yong)電線(xian)電纜(lan)(lan)該類產(chan)品主(zhu)要特征是:品種規格繁多,應用(yong)范(fan)圍(wei)廣泛,使用(yong)電壓在1kV及以下較多,面(mian)對特殊(shu)場合不斷衍生新(xin)的產(chan)品,如耐(nai)火線(xian)纜(lan)(lan)、阻燃線(xian)纜(lan)(lan)、低(di)煙無鹵/低(di)煙低(di)鹵線(xian)纜(lan)(lan)、防白(bai)蟻、防老鼠(shu)線(xian)纜(lan)(lan)、耐(nai)油/耐(nai)寒(han)/耐(nai)溫/耐(nai)磨線(xian)纜(lan)(lan)、醫用(yong)/農(nong)用(yong)/礦用(yong)線(xian)纜(lan)(lan)、薄壁電線(xian)等。
(4)、通訊(xun)(xun)電(dian)纜(lan)(lan)及光纖(簡略介紹)隨(sui)著(zhu)近二(er)十多年來,通訊(xun)(xun)行(xing)業的飛速(su)發展(zhan),產(chan)品也有驚人的發展(zhan)速(su)度。從過去的簡單的電(dian)話(hua)電(dian)報(bao)線纜(lan)(lan)發展(zhan)到幾千對的話(hua)纜(lan)(lan)、同軸纜(lan)(lan)、光纜(lan)(lan)、數(shu)據電(dian)纜(lan)(lan),甚至組合(he)通訊(xun)(xun)纜(lan)(lan)等。
該(gai)類產品結(jie)構(gou)尺(chi)寸通常較小(xiao)而均勻,制造(zao)精度要求高。
(5)、電(dian)(dian)磁線(xian)(繞組線(xian))主要(yao)用于(yu)各(ge)種電(dian)(dian)機、儀器儀表等。
電(dian)線(xian)電(dian)纜的衍生/新產品
電(dian)線電(dian)纜的(de)衍生(sheng)/新產(chan)(chan)品(pin)(pin)主要是(shi)因應(ying)用場合、應(ying)用要求(qiu)不(bu)同及裝備(bei)的(de)方便性和降低裝備(bei)成本等的(de)要求(qiu),而采用新材(cai)料(liao)、特殊材(cai)料(liao)、或(huo)改變產(chan)(chan)品(pin)(pin)結構、或(huo)提高工藝要求(qiu)、或(huo)將不(bu)同品(pin)(pin)種的(de)產(chan)(chan)品(pin)(pin)進行組合而產(chan)(chan)生(sheng)。
采用不同材料如阻燃線(xian)(xian)纜(lan)(lan)、低煙無鹵(lu)/低煙低鹵(lu)線(xian)(xian)纜(lan)(lan)、防白(bai)蟻、防老鼠線(xian)(xian)纜(lan)(lan)、耐(nai)(nai)(nai)油/耐(nai)(nai)(nai)寒/耐(nai)(nai)(nai)溫線(xian)(xian)纜(lan)(lan)等;
改變產品結構如:耐火電纜等;
提(ti)高(gao)工(gong)藝要求(qiu)如:醫用線纜等(deng);
組合(he)產品如:OPGW等;
方便安裝和降低裝備成本如:預制分支電(dian)纜(lan)等(deng)。
32、母線裝置施工完,應進行哪些檢查?
答:應進(jin)行下列檢查:
(1)金屬構件(jian)的加(jia)工(gong)、配制(zhi)、焊接(jie)螺接(jie)應符(fu)合(he)規定;
(2)各部螺栓、墊圈、開口銷(xiao)等零部件應齊(qi)全可靠;
(3)母線配(pei)制及安(an)裝架應符(fu)合(he)規定,相間及對地電(dian)氣距離符(fu)合(he)要求(qiu);
(4)瓷件、鐵件及(ji)膠合處應(ying)完整,充(chong)油套(tao)管應(ying)無滲油,油位(wei)正(zheng)常(chang);
(5)油漆完整,相(xiang)色正確,接(jie)地良(liang)好。
33、在35kv及以下電(dian)力電(dian)纜接頭(tou)中,改善其護套斷(duan)開處(chu)電(dian)場分布的方法有幾種(請(qing)列出五(wu)種),并簡述其方法。
答:(1)脹喇叭口(kou):在(zai)鉛包割斷(duan)處把鉛包邊緣(yuan)撬起,成喇叭狀,其邊緣(yuan)應光滑、圓整(zheng)、對稱。
(2)預留(liu)統包絕緣:在鉛包切口至電纜芯線分開點之間留(liu)有一段(duan)統包絕緣紙(zhi)。
(3)切除半(ban)導(dao)電(dian)紙:將半(ban)導(dao)電(dian)紙切除到喇叭口(kou)以下。
(4)包繞(rao)應力(li)錐:用絕緣包帶和導電金屬材料包成(cheng)錐形,人為地將屏蔽層擴大,以改善電場分布(bu)。
(5)等電(dian)位法:對于干包(bao)型或(huo)交聯(lian)聚乙(yi)烯電(dian)纜頭,在(zai)(zai)各線芯概況絕緣表面上包(bao)一段(duan)金(jin)屬帶,并將(jiang)其連接在(zai)(zai)一起。
(6)裝設(she)應(ying)力(li)控制管:對于35kv及(ji)發下熱縮管電纜頭,首先(xian)從(cong)線芯銅屏蔽層末端(duan)方向經半導體(ti)帶至線芯絕緣概況包(bao)繞2層半導體(ti)帶,然后將(jiang)相應(ying)規格折(zhe)應(ying)力(li)管,套在銅屏蔽的末端(duan)處(chu),熱縮成形。
34、電纜支架(jia)的加工應符合(he)哪些要(yao)求?
答:(1)鋼材應平直,無明顯扭(niu)曲,下料誤差(cha)應在5mm范圍內,切口(kou)應無卷(juan)邊,毛剌;
(2)支架應焊接牢(lao)固(gu),無(wu)顯(xian)蓍(shi)變形,各(ge)橫撐間的垂(chui)直凈距與設計(ji)偏(pian)差(cha)不應大于5mm;
(3)金(jin)屬支架必須進行(xing)防(fang)腐處(chu)理(li),位(wei)于濕熱、鹽、霧以及(ji)有化學(xue)腐蝕(shi)地區時,應根據設(she)計作特殊的防(fang)腐處(chu)理(li)。
35、列舉出你熟(shu)悉的電(dian)纜架(jia)。
答:拼焊式E型(xing)架(jia)、裝(zhuang)配式E型(xing)架(jia)、橋式電(dian)(dian)纜架(jia)、電(dian)(dian)纜托架(jia)、掛(gua)鉤(gou)式支(zhi)架(jia)、單(dan)根電(dian)(dian)纜支(zhi)架(jia)等。
36、敷(fu)設(she)電纜(lan)應滿足(zu)哪些要求?
答:應滿(man)足以下要求:
(1)安全運行(xing)方面(mian),盡可能避免各種外來(lai)損壞,提高電(dian)纜(lan)線路的供電(dian)可靠(kao)性;
(2)經濟方面(mian),從投資最省的方面(mian)考慮(lv);
(3)施(shi)工(gong)方(fang)面,電纜線路的路徑必須便于旋工(gong)和投運(yun)后的維修。
37、制作電纜終端頭(tou)(tou)或中間接頭(tou)(tou)的絕緣材料(liao)有哪些?
答:有絕緣(yuan)膠(jiao)、絕緣(yuan)帶、絕緣(yuan)管、絕緣(yuan)手套(tao)、絕緣(yuan)樹脂等。
38、簡述電纜(lan)頭制作(zuo)的一(yi)般操作(zuo)程序。答:(1)制作(zuo)前的準備:包括○1閱讀安裝說(shuo)明書;○2察看現場;○3備料(liao);○4電纜(lan)試(shi)(shi)潮;○5制作(zuo)前測試(shi)(shi)等(deng)。
(2)接頭的制作過程:包括○1割斷多余電(dian)纜;○2電(dian)纜保護層的剝切;○3導(dao)體連接;○4包繞絕緣(yuan)(yuan)(或收(shou)縮(suo)管材);○5安裝接頭外殼;○6灌(guan)注絕緣(yuan)(yuan)劑(ji);○7進行密封處理等(deng)。
(3)制作后電氣測試。
39、電(dian)纜保護管的加(jia)工(gong)應符合哪些要求?
答(da):(1)管口應*剌和尖銳楞(leng)角,管口宜做成(cheng)喇叭(ba)形。
(2)電纜(lan)管在彎(wan)制后(hou),不(bu)應有裂縫和顯著(zhu)的凹癟現象,其彎(wan)扁程度不(bu)宜(yi)大于(yu)管子外(wai)徑(jing)10%;電纜(lan)管的彎(wan)曲半徑(jing)不(bu)應小于(yu)所穿(chuan)入電纜(lan)的最小允許彎(wan)曲半徑(jing)。
(3)金(jin)屬管應(ying)在外表涂防腐漆或瀝表,鍍鋅(xin)管鋅(xin)層剝落處也應(ying)涂以防腐漆。
40、電纜的排列符(fu)合哪(na)些要求?答:(1)電力電纜和控(kong)纜不(bu)應配置在(zai)同一(yi)層(ceng)支架上。
(2)高、低壓電纜,強、弱電控纜應(ying)按須序(xu)分層(ceng)配置(zhi),一般情況宜由(you)上而下(xia),但在含有35kv以上高壓電纜引入柜盤時,為滿足彎曲(qu)半徑,可由(you)下(xia)面上配置(zhi)。
41、電(dian)(dian)纜溝內敷設電(dian)(dian)纜的方法(fa)是(shi)什么?
答:在(zai)(zai)電(dian)(dian)纜(lan)溝(gou)內敷設電(dian)(dian)纜(lan)的方(fang)法(fa)與(yu)直(zhi)埋電(dian)(dian)纜(lan)的敷設方(fang)法(fa)相(xiang)仿(fang),一(yi)般可將滑輪放在(zai)(zai)溝(gou)內,施放完畢(bi),將電(dian)(dian)纜(lan)放于(yu)溝(gou)底或(huo)支架上(shang),并(bing)在(zai)(zai)電(dian)(dian)纜(lan)上(shang)綁扎電(dian)(dian)纜(lan)標牌。
42、電纜(lan)敷(fu)設的常(chang)用(yong)設備有哪(na)些?
答:(1)空氣壓(ya)縮機(ji),主要(yao)用來破壞路面,為(wei)以(yi)后敷設(she)電纜作準備;
(2)電(dian)(dian)動卷揚(yang)機(ji)或電(dian)(dian)纜牽引機(ji),主要用來拖(tuo)電(dian)(dian)纜;
(3)電(dian)(dian)纜輸(shu)送機,配合牽引機使用來克服巨大的摩擦力(li),減輕(qing)對電(dian)(dian)纜的損(sun)壞;
(4)電纜(lan)盤放線支(zhi)架(jia);
(5)滾(gun)輪裝置;
(6)防(fang)捻 ,減鋼(gang)絲繩(sheng)出現的(de)扭(niu)曲;
(7)電(dian)纜盤制動裝置;
(8)張力(li)計(ji)。
43、電(dian)(dian)纜(lan)溝中(zhong)支(zhi)架安裝(zhuang)距離(li)的(de)(de)要求如何?答:電(dian)(dian)纜(lan)固(gu)定于電(dian)(dian)纜(lan)溝和隧道的(de)(de)墻(qiang)上,水平裝(zhuang)置時,當電(dian)(dian)纜(lan)外(wai)徑等(deng)于或(huo)小于50mm時應每(mei)隔1m加(jia)一(yi)支(zhi)撐(cheng);外(wai)徑大于50mm的(de)(de)電(dian)(dian)纜(lan)每(mei)隔0.6m加(jia)一(yi)支(zhi)撐(cheng);排(pai)成三角形的(de)(de)單電(dian)(dian)纜(lan),每(mei)隔1m應用綁帶扎牢,垂直裝(zhuang)置時,每(mei)隔1~1.5m加(jia)以固(gu)定。
44、如何(he)處理電力電纜與控(kong)制(zhi)電纜在同(tong)一托(tuo)架的安(an)裝?
答:電(dian)(dian)力(li)電(dian)(dian)纜與控制電(dian)(dian)纜一(yi)般不應敷設(she)在(zai)同一(yi)托架內,當電(dian)(dian)纜較少而將控纜與電(dian)(dian)力(li)電(dian)(dian)纜敷設(she)在(zai)同一(yi)托架內時,應用隔板隔開。
45、電纜隧(sui)道(dao)內(nei)如何(he)裝設(she)接(jie)地線?
答:隧(sui)道和溝(gou)的(de)(de)全(quan)長(chang)應(ying)(ying)(ying)裝(zhuang)設連(lian)(lian)續的(de)(de)接(jie)(jie)(jie)地(di)(di)(di)(di)線,接(jie)(jie)(jie)地(di)(di)(di)(di)線應(ying)(ying)(ying)和所(suo)有的(de)(de)支架(jia)相(xiang)連(lian)(lian),兩頭和接(jie)(jie)(jie)地(di)(di)(di)(di)極連(lian)(lian)通。接(jie)(jie)(jie)地(di)(di)(di)(di)線的(de)(de)規格應(ying)(ying)(ying)符合(he)設計(ji)要求。電纜(lan)鉛包和鎧裝(zhuang)除了有絕(jue)緣要求外,應(ying)(ying)(ying)全(quan)部相(xiang)互連(lian)(lian)接(jie)(jie)(jie)并和接(jie)(jie)(jie)地(di)(di)(di)(di)線相(xiang)連(lian)(lian),電纜(lan)架(jia)和接(jie)(jie)(jie)地(di)(di)(di)(di)線均應(ying)(ying)(ying)涂防銹漆(qi)或鍍鋅。
46、對于(yu)電(dian)纜(lan)孔洞(dong)的防火(huo)封堵有(you)何要求?
答:對于較(jiao)大的電(dian)纜貫(guan)穿孔(kong)洞(dong),如電(dian)纜貫(guan)穿樓板處等,采用(yong)防火(huo)堵(du)料(liao)封(feng)堵(du)時(shi),應根據實際情(qing)況,先在(zai)電(dian)纜表面涂四(si)至六(liu)層防火(huo)涂料(liao),長度自孔(kong)洞(dong)以(yi)下1.5m左右(you),再用(yong)耐火(huo)材料(liao)加工成具有一(yi)定強度的板托防火(huo)堵(du)料(liao),保證封(feng)堵(du)后牢固并便于更換電(dian)纜時(shi)拆裝,封(feng)堵(du)密實無孔(kong)隙(xi)以(yi)有效地堵(du)煙堵(du)火(huo)。
47、噴燈點火前應注意哪些檢查?
答:應進行(xing)下(xia)列各項檢查:
(1)打氣(qi)筒是否(fou)漏(lou)油(you)或滲油(you),油(you)桶及噴嘴處是否(fou)漏(lou)油(you)、漏(lou)氣(qi);
(2)油(you)桶內的(de)油(you)量(liang)是否超(chao)過油(you)桶容量(liang)的(de)3/4,加油(you)的(de)螺絲(si)塞是否擰緊。
48、使(shi)用噴燈應(ying)注意(yi)哪些事項?
答:(1)噴燈更大(da) 注油(you)量為油(you)筒容積的3/4;
(2)開始打(da)氣(qi)壓(ya)力不要太(tai)大,點燃后(hou)火焰由黃變藍即可使用;
(3)周圍不(bu)得有易燃物,空氣(qi)要流通(tong);
(4)停用時先(xian)關閉調(diao)(diao)節(jie)開(kai)關,火熄后,慢慢旋(xuan)松油孔(kong)蓋放(fang)氣,空氣放(fang)完后,要(yao)要(yao)旋(xuan)松調(diao)(diao)節(jie)開(kai)關,完全冷卻后再(zai)旋(xuan)松孔(kong)蓋;
(5)煤油噴燈(deng)與(yu)汽油噴燈(deng)要(yao)分(fen)開使(shi)用。
49、手動油壓(ya)鉗有何用(yong)途(tu)?如(ru)何操(cao)作?
答:兩(liang)根(gen)導線(xian)的(de)(de)連接(jie)通(tong)常(chang)是(shi)將(jiang)兩(liang)導線(xian)端(duan)穿入(ru)相(xiang)同(tong)材料制成的(de)(de)壓(ya)(ya)(ya)(ya)管(guan)中,用壓(ya)(ya)(ya)(ya)接(jie)鉗擠壓(ya)(ya)(ya)(ya)數個(ge)坑(keng),使導線(xian)連接(jie)在一(yi)起(qi),壓(ya)(ya)(ya)(ya)接(jie)時(shi)(shi)(shi),手柄(bing)向(xiang)上抬起(qi)時(shi)(shi)(shi),柱(zhu)塞(sai)(sai)(sai)向(xiang)外移動(dong)(dong),進油(you)閥(fa)下腔(qiang)產生真空,油(you)箱(xiang)內的(de)(de)油(you)進入(ru)柱(zhu)塞(sai)(sai)(sai)腔(qiang)。手柄(bing)下壓(ya)(ya)(ya)(ya)時(shi)(shi)(shi),柱(zhu)塞(sai)(sai)(sai)向(xiang)內移動(dong)(dong),油(you)受(shou)壓(ya)(ya)(ya)(ya)后(hou),使進油(you)閥(fa)關閉,打開出油(you)閥(fa),使油(you)壓(ya)(ya)(ya)(ya)進入(ru)液(ye)壓(ya)(ya)(ya)(ya)缸,推動(dong)(dong)活塞(sai)(sai)(sai)和陽模(mo),陽、陰模(mo)之(zhi)間放有壓(ya)(ya)(ya)(ya)接(jie)管(guan),當(dang)壓(ya)(ya)(ya)(ya)接(jie)被擠壓(ya)(ya)(ya)(ya)的(de)(de)坑(keng)深到一(yi)定值時(shi)(shi)(shi),開啟(qi)回油(you)閥(fa),活塞(sai)(sai)(sai)自動(dong)(dong)返回,壓(ya)(ya)(ya)(ya)完一(yi)個(ge)坑(keng)后(hou),移動(dong)(dong)壓(ya)(ya)(ya)(ya)鉗,再(zai)壓(ya)(ya)(ya)(ya)下一(yi)個(ge)。
50、常用低壓電力電纜按(an)絕緣(yuan)和保(bao)護(hu)層的不同,主(zhu)要(yao)可分為(wei)哪幾類?
答:(1)油浸紙絕緣鉛(qian)包(bao)(或(huo)鋁包(bao))電力電纜;
(2)不(bu)滴(di)流(liu)油(you)浸紙絕緣電力(li)電纜;
(3)聚(ju)氯乙(yi)烯絕緣聚(ju)氯乙(yi)烯護套電力(li)電纜;
(4)交(jiao)聯聚氯乙(yi)烯(xi)絕緣(yuan)聚乙(yi)烯(xi)護(hu)套電(dian)(dian)力(li)電(dian)(dian)纜(lan);
(5)交聯聚氯乙烯絕緣聚氯乙烯護套(tao)電(dian)(dian)力電(dian)(dian)纜;
(6)橡皮(pi)絕緣電力(li)電纜。
51、常用(yong)絕(jue)緣材(cai)料的類(lei)別哪(na)些?舉例說明?
答(da):(1)無機絕緣材料(liao):有云母(mu)、石(shi)(shi)棉(mian)、大理(li)石(shi)(shi)、瓷器、玻(bo)璃等;
(2)有(you)機絕緣材料:有(you)樹脂、橡(xiang)膠(jiao)、紙、麻、棉紗等;
(3)混合絕(jue)緣(yuan)(yuan)材料(liao):用以上絕(jue)緣(yuan)(yuan)材料(liao)加工而成型的名(ming)種(zhong)絕(jue)緣(yuan)(yuan)材料(liao)。
52、在哪種情況(kuang)下采用排管敷設(she)?有什么優點?
答:排(pai)管敷設一般用(yong)在與其他建(jian)筑(zhu)物(wu)、公(gong)路或鐵路相交(jiao)叉的(de)地方,有時(shi)也在建(jian)筑(zhu)物(wu)密集區內(nei)采用(yong)。主要優點(dian)是占地少,能(neng)承受大(da)的(de)荷重,電纜相互間互不影響(xiang),比較安全。
53、何謂電(dian)纜(lan)長(chang)期允許(xu)載流量?
答:電纜長期允許(xu)載(zai)流(liu)量是指在電纜內(nei)通過規定(ding)電流(liu)時(shi),在熱穩定(ding)后,電纜導體達到長期允許(xu)工作溫度時(shi)的電流(liu)數值。
54、決定(ding)電纜長期允(yun)許載流(liu)量的因素有哪些?
答:有(you)以(yi)下三個(ge)因素決定:
(1)電纜的長期容許(xu)工(gong)作溫度;
(2)電纜本(ben)身的(de)散熱性能(neng);
(3)電纜裝置(zhi)情況(kuang)及周圍(wei)環(huan)境的(de)散(san)熱條件。
55、電(dian)纜的(de)敷設(she)方式(shi)有幾種?
答:有以下幾種(zhong):
(1)直埋在(zai)地下;
(2)安裝在電纜(lan)溝(gou)內;
(3)安裝在地下隧道內;
(4)安裝(zhuang)在(zai)建筑物內部墻上(shang)或天棚上(shang);
(5)安裝在橋架上;
(6)敷(fu)設在排管內;
(7)敷設在水底。
56、如何(he)進行電(dian)纜管的連接工作?
答(da):電(dian)纜管(guan)連(lian)接時(shi),必(bi)須用(yong)扣和(he)管(guan)接頭連(lian)接,如采用(yong)焊接時(shi),不能直接對焊,連(lian)接處(chu)要(yao)套上(shang)一段粗管(guan)再進行(xing)焊接,以(yi)免焊渣(zha)掉(diao)入管(guan)內。
57、制(zhi)作(zuo)電(dian)(dian)纜頭時,對(dui)上下扳彎(wan)電(dian)(dian)纜芯(xin)線有(you)何要求?
答:扳彎(wan)線(xian)芯(xin)時(shi)(shi),不得損傷(shang)紙絕緣(yuan),芯(xin)線(xian)的彎(wan)曲(qu)半徑不得小(xiao)于電(dian)纜(lan)線(xian)芯(xin)的10倍。制作時(shi)(shi)要特(te)別小(xiao)心,應(ying)使線(xian)芯(xin)彎(wan)曲(qu)部分均勻受力,否則極易損傷(shang)絕緣(yuan)紙。
58、簡述塑料電纜的熱收縮密(mi)封法。
答(da):熱(re)(re)縮法適用(yong)于中、低(di)壓橡(xiang)、塑電纜接(jie)頭和(he)(he)終端(duan)頭的(de)密(mi)(mi)封(feng),也可適用(yong)于不滴(di)流和(he)(he)黏性浸漬絕緣(yuan)電纜。采用(yong)交聯聚乙烯型和(he)(he)硅(gui)橡(xiang)膠(jiao)型兩大類遇熱(re)(re)后能均勻收縮的(de)熱(re)(re)收縮管。將這種管材套于預(yu)定的(de)粘合密(mi)(mi)封(feng)部位,并在粘和(he)(he)部位涂(tu)上熱(re)(re)熔膠(jiao),當加(jia)熱(re)(re)到一定溫度后,熱(re)(re)縮管將收縮,同時(shi)熱(re)(re)熔膠(jiao)熔化,待自(zi)然冷卻(que)后即(ji)形成一道良好的(de)密(mi)(mi)封(feng)封(feng)層。
59、用電(dian)動(dong)彎管(guan)機(ji)彎制(zhi)電(dian)纜保護管(guan)時應注意(yi)什么?
答:(1)彎(wan)管機應由(you)了解其(qi)性能并(bing)熟悉操作知(zhi)識的人員(yuan)操作;
(2)使用(yong)前必須進行檢(jian)查,按(an)鈕、操作把手、行程開關應(ying)完(wan)好,彎管(guan)機必須可靠接地;
(3)選用符合要(yao)求的模具,確定好(hao)所需要(yao)的彎曲(qu)半(ban)徑;
(4)施工場(chang)地周圍,應有(you)充(chong)足的(de)活動(dong)范圍;
(5)使(shi)用時(shi)待空轉正常后,方可(ke)帶(dai)負荷工作,運行(xing)中(zhong),嚴(yan)禁用手腳接觸其轉動(dong)部分;
(6)工作完(wan)畢應及時停電,釋放油壓。
60、電纜(lan)清冊的(de)內容及電纜(lan)編(bian)號(hao)的(de)含義是(shi)什么?
答:電(dian)纜(lan)清冊是施放電(dian)纜(lan)和指導施工的依據,運行維護的檔案資料。應(ying)列入每根電(dian)纜(lan)的編號(hao)、起始點、型號(hao)、規格、長度,并分類(lei)統計出總長度,控纜(lan)還應(ying)列出每根電(dian)纜(lan)的備用芯。
電纜(lan)編(bian)號是(shi)識別電纜(lan)的標志,故要求全廠(chang)編(bian)號不(bu)重復,并且有一定的含義和規律,能表達電纜(lan)的特征。
61、電纜目(mu)前(qian)采(cai)用(yong)的敷設方(fang)法(fa)可分為幾(ji)類?
答(da):(1)人工敷(fu)設,即采用人海戰術,在一人或多人協調指揮下,按規定進行敷(fu)設;
(2)機(ji)械(xie)化敷設,即采用滾輪、牽引器、輸送機(ji),通過一同步電源(yuan)進行控制,比較安全;
(3)人工和(he)機械(xie)相結合,有些(xie)現場(chang)由于(yu)轉彎(wan)較多,施工難(nan)度大(da),全用(yong)(yong)機械(xie)較困(kun)難(nan),所(suo)以采用(yong)(yong)此法。
62、控制(zhi)二次回路接線(xian)應符合哪(na)些要求(qiu)?
答:(1)按圖施工接線(xian)正確(que);
(2)導線(xian)的(de)電(dian)氣(qi)連(lian)接(jie)應牢固可靠;
(3)盤柜內(nei)的導線不應(ying)有(you)接(jie)頭(tou),導線芯(xin)線應(ying)無損傷;
(4)電纜芯線端部應(ying)標明其回路(lu)編號,編號應(ying)正確,字跡清(qing)晰且不(bu)易脫色(se);
(5)配(pei)線(xian)應(ying)整齊、清晰、美(mei)觀,導線(xian)絕(jue)緣應(ying)良好、無損;
(6)每個接(jie)線端子的(de)每側接(jie)線宜為一根,最多不得超過兩(liang)根。
63、電纜(lan)排管(guan)有何(he)要求?
答:(1)排管頂部(bu)至地(di)面距離,在廠房內為0.2m,人行道下(xia)為0.5m,一般地(di)區為0.7m;
(2)在變更方(fang)向及分支處均應(ying)裝(zhuang)置排管(guan)井坑(keng),長度(du)超過30mm時也(ye)應(ying)加(jia)設(she)井坑(keng);
(3)井坑深度不(bu)小(xiao)于(yu)0.8m,人孔直徑不(bu)小(xiao)于(yu)0.7mm;
(4)排(pai)管應(ying)有傾向井坑0.5%~1%的排(pai)水坡度。
64、對(dui)于電纜導(dao)體(ti)連接點的電阻有何要求?
答:要(yao)求連接點的(de)電(dian)阻小(xiao)而且穩定(ding),連接點的(de)電(dian)阻與相同(tong)長度、相同(tong)截面的(de)導體之比(bi)值,對于(yu)(yu)新安裝(zhuang)的(de)終端頭(tou)和中間頭(tou),應不大(da)于(yu)(yu)1;對于(yu)(yu)運(yun)行中的(de)終端頭(tou)和中間頭(tou)這(zhe)個比(bi)值不應大(da)于(yu)(yu)1.2。
65、電纜接頭和(he)中間頭的設計應滿足哪些要求?
答:應滿足的(de)要求有:
(1)耐壓(ya)強度高,導體連接好(hao);
(2)機械強度大,介(jie)質損失小;
(3)結構簡(jian)單,密(mi)封性強。
66、什么是電纜故障?有幾(ji)種(zhong)常見的類(lei)型?
答:電(dian)纜故(gu)障(zhang)是指(zhi)電(dian)纜在預防(fang)性試驗時發(fa)生絕緣(yuan)擊穿或在運(yun)行中,因絕緣(yuan)擊穿、導線(xian)(xian)燒斷等而迫使電(dian)纜線(xian)(xian)路停(ting)電(dian)的(de)故(gu)障(zhang)。常見的(de)故(gu)障(zhang)有接地故(gu)障(zhang)、短(duan)路故(gu)障(zhang)、斷線(xian)(xian)故(gu)障(zhang)、閃絡(luo)性故(gu)障(zhang)和混合型故(gu)障(zhang)等。
67、如何處理電(dian)纜(lan)線路(lu)的單(dan)相接地故障?
答:電(dian)纜線(xian)路(lu)單相接地故(gu)障(zhang)一般來(lai)說,電(dian)纜導體的(de)(de)損傷(shang)只是局部(bu)的(de)(de),如果(guo)屬于機(ji)械損傷(shang),而故(gu)障(zhang)點附近的(de)(de)土壤(rang)又較干燥時(shi),一般可進行局部(bu)修理,加添一只假接頭,即(ji)不(bu)將電(dian)纜芯鋸斷(duan),僅將故(gu)障(zhang)點絕緣(yuan)加強(qiang)后(hou)密封即(ji)可。
68、電力電纜在敷(fu)設前應(ying)進行哪些試驗和檢查?
答:敷設前(qian)應檢查(cha)電(dian)(dian)纜(lan)的(de)型號、規格及長度是否(fou)符合要(yao)求,是否(fou)有(you)外力損傷,低壓(ya)電(dian)(dian)纜(lan)用1000V兆歐(ou)表遙(yao)測絕緣電(dian)(dian)阻,阻值一般不低于(yu)10MΩ,高壓(ya)電(dian)(dian)纜(lan)用2500V兆歐(ou)表搖測阻值一般不抵于(yu)400MΩ。
69、主廠(chang)房(fang)內敷設電纜時(shi)一般應注意(yi)什么?
答:在主廠房內敷設(she)電纜時一般應注意(yi):
(1)凡引至集(ji)控(kong)室的控(kong)制電纜宜架空敷設;
(2)6KV電纜宜用隧道或排管(guan)敷(fu)設(she),地下水位(wei)高處亦可架空(kong)或用排管(guan)敷(fu)設(she);
(3)380V電纜當兩(liang)端(duan)電纜在零米時宜(yi)用隧道、溝或(huo)排管,當一端(duan)設(she)(she)備在上、一端(duan)在下時,可部分架空敷設(she)(she),當地下水位(wei)較高時,宜(yi)架空。
70、電力電纜的(de)內屏(ping)蔽層(ceng)與外屏(ping)蔽層(ceng)各在什么部(bu)位(wei)?采(cai)用(yong)什么材料?有何作用(yong)?
答(da):為(wei)了使(shi)絕緣層和電(dian)纜導(dao)(dao)體(ti)(ti)有較(jiao)好的(de)(de)(de)(de)接觸(chu),消除導(dao)(dao)體(ti)(ti)表(biao)面(mian)的(de)(de)(de)(de)不光滑引起的(de)(de)(de)(de)導(dao)(dao)體(ti)(ti)表(biao)面(mian)電(dian)場強度的(de)(de)(de)(de)增加(jia),一般在導(dao)(dao)體(ti)(ti)表(biao)面(mian)包有金屬化紙或(huo)(huo)半導(dao)(dao)體(ti)(ti)紙帶的(de)(de)(de)(de)內(nei)屏(ping)蔽(bi)層。為(wei)了使(shi)絕緣層和金屬護套(tao)有較(jiao)好的(de)(de)(de)(de)接觸(chu),一般在絕緣層外(wai)表(biao)面(mian)包有外(wai)層屏(ping)蔽(bi)層。外(wai)屏(ping)層與內(nei)屏(ping)層的(de)(de)(de)(de)材料相同,有時還(huan)外(wai)扎銅(tong)帶或(huo)(huo)編(bian)織銅(tong)絲(si)帶。
71、簡述(shu)環氧樹脂復合物的構成及性(xing)能。
答:環(huan)氧樹(shu)脂(zhi)(zhi)復合(he)物(wu)由環(huan)氧樹(shu)脂(zhi)(zhi)加入(ru)硬化劑(ji)、填充劑(ji)增韌劑(ji)和稀釋劑(ji)組成。具(ju)有以下性能:
(1)有足夠(gou)的(de)機械(xie)強度;
(2)電氣性能(neng)優良(liang);
(3)電(dian)氣(qi)性能穩定(ding);
(4)與有色金屬有足夠的(de)黏附力;
(5)耐腐蝕性好;
(6)戶(hu)外使用時(shi),耐(nai)(nai)雨、耐(nai)(nai)光、耐(nai)(nai)濕(shi)熱。
72、單芯電(dian)纜(lan)護(hu)套一端接地方式中為(wei)什么必(bi)須(xu)安裝一條沿電(dian)纜(lan)平行敷設的(de)回流線?
答:在金屬護套(tao)一端接(jie)(jie)地(di)(di)的(de)(de)(de)(de)(de)電(dian)(dian)(dian)纜(lan)線路(lu)中(zhong),為(wei)(wei)確保護套(tao)中(zhong)的(de)(de)(de)(de)(de)感應(ying)電(dian)(dian)(dian)壓不(bu)超(chao)過允許標準,必須安裝(zhuang)一條沿電(dian)(dian)(dian)纜(lan)線路(lu)平行敷(fu)設的(de)(de)(de)(de)(de)導(dao)體,且導(dao)體的(de)(de)(de)(de)(de)兩端接(jie)(jie)地(di)(di),這種導(dao)體稱為(wei)(wei)回(hui)流(liu)(liu)(liu)線。當(dang)發生單相接(jie)(jie)地(di)(di)故(gu)障(zhang)時(shi),接(jie)(jie)地(di)(di)短(duan)路(lu)電(dian)(dian)(dian)流(liu)(liu)(liu)可(ke)(ke)以(yi)通過回(hui)流(liu)(liu)(liu)線流(liu)(liu)(liu)回(hui)系統中(zhong)心點,由于通過回(hui)流(liu)(liu)(liu)線的(de)(de)(de)(de)(de)接(jie)(jie)地(di)(di)電(dian)(dian)(dian)流(liu)(liu)(liu)產(chan)生的(de)(de)(de)(de)(de)磁(ci)通抵消了一部分電(dian)(dian)(dian)纜(lan)導(dao)線接(jie)(jie)地(di)(di)電(dian)(dian)(dian)流(liu)(liu)(liu)所產(chan)生的(de)(de)(de)(de)(de)磁(ci)通,因而可(ke)(ke)降低短(duan)路(lu)故(gu)障(zhang)時(shi)護套(tao)的(de)(de)(de)(de)(de)感應(ying)電(dian)(dian)(dian)壓。
73、電纜工程可劃分(fen)為幾(ji)個項目(mu)?
答:(1)工(gong)地運輸(shu)(shu):包括工(gong)程材料從倉庫到施工(gong)點(dian)的裝卸、運輸(shu)(shu)和(he)空車回程。
(2)地方工(gong)程:包括路面開挖(wa)、隧、溝道(dao)施工(gong)等。
(3)敷(fu)設工程:包括敷(fu)設、中間頭(tou)(tou)制作、掀蓋板、埋(mai)管、校(xiao)潮、牽(qian)引頭(tou)(tou)制作等。
(4)兩端(duan)工程:包(bao)括支、吊橋架和(he)其基礎(chu)的制(zhi)(zhi)作(zuo)安(an)裝(zhuang),終(zhong)端(duan)頭制(zhi)(zhi)作(zuo),油壓(ya)力和(he)信號裝(zhuang)置的安(an)裝(zhuang),名種(zhong)電氣性(xing)能測試等。
(5)塞(sai)止工程:包括充油電纜塞(sai)止頭制作,供油箱、自動排水及(ji)信(xin)號裝置的安裝等。
(6)接(jie)地工(gong)程:包括絕緣接(jie)頭、換位箱、保(bao)護器、接(jie)地箱安裝等。
74、電纜線(xian)路的驗收(shou)應進行(xing)哪(na)些(xie)檢查?
答:(1)電纜規格應(ying)符(fu)合規定,排列應(ying)整齊,無損(sun)傷,標(biao)牌齊全、正確、清晰(xi);
(2)電(dian)(dian)纜的(de)(de)固(gu)定彎曲半徑、有關距離(li)及單芯電(dian)(dian)力電(dian)(dian)纜的(de)(de)金屬護層的(de)(de)接線應符合要求;
(3)電纜(lan)終端(duan)、中(zhong)間(jian)頭不滲漏油(you),安裝牢固,充油(you)電纜(lan)油(you)壓及(ji)表(biao)計(ji)整定(ding)值應符合要求;
(4)接(jie)地良好;
(5)電纜終端相色正確,支架等(deng)的金屬(shu)部件油漆完整;
(6)電(dian)纜溝及(ji)隧道內、橋架(jia)上應無雜物,蓋板齊全。
75、電纜線路正序阻(zu)抗(kang)測量(liang)過程(cheng)中有什么要求?
答:電纜導體的交流(liu)電阻和(he)電纜三相(xiang)同(tong)感抗(kang)的相(xiang)量和(he)稱為正(zheng)序阻抗(kang)。
電(dian)纜線路的(de)(de)(de)正(zheng)序(xu)阻抗(kang)一般(ban)可在電(dian)纜盤上直接(jie)(jie)測量(liang),測量(liang)時(shi)一般(ban)使用較(jiao)低(di)的(de)(de)(de)電(dian)壓(ya)(ya)(ya),因(yin)此,需要(yao)(yao)用降(jiang)壓(ya)(ya)(ya)變壓(ya)(ya)(ya)器進行降(jiang)壓(ya)(ya)(ya),降(jiang)壓(ya)(ya)(ya)器采用星形接(jie)(jie)線,容量(liang)一般(ban)為10kVA以(yi)上,有較(jiao)廣的(de)(de)(de)電(dian)壓(ya)(ya)(ya)調節范圍,測量(liang)時(shi)交流電(dian)源應比較(jiao)穩定,以(yi)保證測量(liang)時(shi)電(dian)流達(da)到規(gui)定的(de)(de)(de)要(yao)(yao)求,實(shi)際電(dian)壓(ya)(ya)(ya)表(biao)的(de)(de)(de)讀數(shu)值(zhi)必(bi)須(xu)是電(dian)纜端的(de)(de)(de)電(dian)壓(ya)(ya)(ya),試驗電(dian)流更好(hao) 接(jie)(jie)近電(dian)纜長期(qi)允許(xu)載流量(liang),測讀各表(biao)計的(de)(de)(de)數(shu)值(zhi)時(shi),合上電(dian)流后(hou)同時(shi)讀取三個表(biao)的(de)(de)(de)數(shu)值(zhi)。
76、根(gen)據《電業(ye)生(sheng)產(chan)安全規定》,電氣工作人(ren)員必(bi)須具備的條件是什(shen)么?
答(da):必(bi)須具備下列條件:
(1)經醫生鑒(jian)定身體(ti)健康,無妨礙工作的病癥;
(2)具(ju)備必要的(de)電(dian)氣知識(shi),按其職務和工作(zuo)性質掌握相關(guan)的(de)規程、專業技術(shu)及安全操(cao)作(zuo)技術(shu),并經考試合格;
(3)熟練掌握(wo)觸電(dian)急救(jiu)方法。
77、電纜(lan)在(zai)運輸裝卸(xie)過(guo)程中應注意(yi)什么?
答:(1)在運輸裝卸(xie)過程中,不應使電纜(lan)(lan)及電纜(lan)(lan)盤受到(dao)損(sun)傷,嚴(yan)禁(jin)將電纜(lan)(lan)盤直接由(you)車上推(tui)下,電纜(lan)(lan)般不應平(ping)放(fang)運輸,平(ping)放(fang)貯存。
(2)運輸或滾動電纜盤(pan)前,必須保證(zheng)電纜盤(pan)牢固,電纜繞(rao)緊、充油電纜至壓(ya)力(li)(li)油箱間的油管應(ying)固定,不得(de)損傷(shang),壓(ya)力(li)(li)油箱應(ying)牢固,壓(ya)力(li)(li)指示應(ying)符合要求。
78、電纜防火有(you)哪些措施?
答:(1)采用阻燃電纜;
(2)采用防火電纜托(tuo)架;
(3)采(cai)用(yong)防(fang)火(huo)涂(tu)料;
(4)電纜(lan)隧(sui)道、夾層(ceng)出口等處設置防火(huo)隔墻、防火(huo)擋(dang)板;
(5)架空電纜應避開油(you)管(guan)(guan)道、防爆(bao)門,否則應有要取(qu)局部穿管(guan)(guan)或隔熱防火措施。
79、選擇電(dian)力電(dian)纜的(de)截面(mian)應從(cong)哪幾個方(fang)面(mian)考慮?
答:應考(kao)慮如下幾(ji)個方面(mian):
(1)電(dian)纜長期(qi)允許通過的工作電(dian)流;
(2)一旦短(duan)路時的熱穩定性;
(3)線路上的電壓降不能超出允許工作范圍。
80、電力電纜和(he)架(jia)空線比較有哪(na)些優(you)點?
答(da):(1)運行(xing)可靠(kao),由(you)于安裝在地下等(deng)隱蔽處,受(shou)外力(li)破壞小,發生故障(zhang)的(de)機會較少,供電安全,不會給人(ren)身造成危(wei)害;
(2)維護工(gong)作(zuo)量小(xiao),不需頻繁的(de)巡檢;
(3)不需架設桿(gan)塔;
(4)有(you)助于提高功(gong)率因數。