1、常用的電線、電纜按(an)用途分有哪些種(zhong)類?
答:按用(yong)途可分為裸導線(xian)、絕緣電(dian)線(xian)、耐熱(re)電(dian)線(xian)、屏蔽電(dian)線(xian)、電(dian)力電(dian)纜、控制電(dian)纜、通信電(dian)纜、射頻電(dian)纜等。
2、絕緣電線有(you)哪幾種?
答:常(chang)有(you)的絕緣(yuan)(yuan)電線(xian)(xian)有(you)以下幾種:聚(ju)氯乙烯絕緣(yuan)(yuan)電線(xian)(xian)、聚(ju)氯乙烯絕緣(yuan)(yuan)軟(ruan)線(xian)(xian)、丁腈聚(ju)氯乙烯混合(he)物絕緣(yuan)(yuan)軟(ruan)線(xian)(xian)、橡皮絕緣(yuan)(yuan)電線(xian)(xian)、農用(yong)地下直埋鋁芯塑料(liao)絕緣(yuan)(yuan)電線(xian)(xian)、橡皮絕緣(yuan)(yuan)棉(mian)紗紡織(zhi)軟(ruan)線(xian)(xian)、聚(ju)氯乙烯絕緣(yuan)(yuan)尼龍(long)護套電線(xian)(xian)、電力和(he)照明用(yong)聚(ju)氯乙烯絕緣(yuan)(yuan)軟(ruan)線(xian)(xian)等。
3、電纜橋架適合于何種場合?
答:電(dian)(dian)纜(lan)橋架(jia)(jia)適用于一(yi)般工礦企業室內(nei)(nei)外(wai)架(jia)(jia)空敷設(she)電(dian)(dian)力電(dian)(dian)纜(lan)、控制電(dian)(dian)纜(lan),亦可(ke)用于電(dian)(dian)信(xin)、廣(guang)播電(dian)(dian)視等(deng)部門在(zai)室內(nei)(nei)外(wai)架(jia)(jia)設(she)。
4、電纜(lan)附件有哪些?
答(da):常用的電(dian)附件有電(dian)纜(lan)(lan)終端(duan)(duan)接線(xian)盒、電(dian)纜(lan)(lan)中(zhong)間(jian)接線(xian)盒、連(lian)接管及接線(xian)端(duan)(duan)子(zi)、鋼(gang)板接線(xian)槽、電(dian)纜(lan)(lan)橋架等。
5、什(shen)么(me)叫電纜中間接頭?
答(da):連接電(dian)(dian)纜(lan)與電(dian)(dian)纜(lan)的(de)導體、絕緣(yuan)屏(ping)蔽層(ceng)和保護層(ceng),以使電(dian)(dian)纜(lan)線路(lu)連接的(de)裝置,稱為電(dian)(dian)纜(lan)中間接頭。
6、什么叫(jiao)電氣主接線?
答:電(dian)氣主(zhu)接(jie)線(xian)是發(fa)電(dian)廠、變電(dian)所中主(zhu)要電(dian)氣設備(bei)和(he)母線(xian)的(de)連接(jie)方(fang)式(shi)(shi),包括主(zhu)母線(xian)和(he)廠用電(dian)系統按一定的(de)功能要求的(de)連接(jie)方(fang)式(shi)(shi)。
7、在選(xuan)擇電(dian)力電(dian)纜的截面時,應遵照哪些規(gui)定?
答:電(dian)(dian)(dian)力電(dian)(dian)(dian)纜(lan)的選擇應(ying)遵照以下原則(ze):(1)電(dian)(dian)(dian)纜(lan)的額定電(dian)(dian)(dian)壓要(yao)大(da)于(yu)或(huo)等(deng)于(yu)安裝點供電(dian)(dian)(dian)系統(tong)的額定電(dian)(dian)(dian)壓;(2)電(dian)(dian)(dian)纜(lan)持(chi)續容許電(dian)(dian)(dian)流(liu)(liu)應(ying)等(deng)于(yu)或(huo)大(da)于(yu)供電(dian)(dian)(dian)負載的更(geng)大(da) 持(chi)續電(dian)(dian)(dian)流(liu)(liu);(3)線芯截(jie)面要(yao)滿(man)足供電(dian)(dian)(dian)系統(tong)短路(lu)(lu)(lu)時的穩定性(xing)的要(yao)求;(4)根據(ju)電(dian)(dian)(dian)纜(lan)長度驗算電(dian)(dian)(dian)壓降是否符合要(yao)求;(5)線路(lu)(lu)(lu)末端的最小短路(lu)(lu)(lu)電(dian)(dian)(dian)流(liu)(liu)應(ying)能使保護(hu)裝置可靠的動(dong)作。
8、交(jiao)聯聚乙烯電纜和油(you)紙電纜比較有哪(na)些優點?
答(da):(1)易安裝(zhuang),因為(wei)它允許最小(xiao)彎曲半徑(jing)小(xiao)、且重量輕;(2)不受線(xian)路(lu)落差(cha)*;(3)熱性(xing)能(neng)好,允許工(gong)作溫度高、傳輸容量大;(4)電(dian)纜(lan)附件簡(jian)單(dan),均為(wei)干式結構;(5)運行維護簡(jian)單(dan),無漏油問題(ti);(6)價格較低;(7)可靠性(xing)高、故障(zhang)率(lv)低;(8)制造(zao)工(gong)序少、工(gong)藝簡(jian)單(dan),經(jing)濟(ji)效益顯著。
9、固定(ding)交流(liu)單芯電纜(lan)的夾具有(you)什(shen)么要求?為(wei)什(shen)么?
答:夾具應(ying)無鐵(tie)件構成閉合磁(ci)(ci)路(lu),這是因為當電纜線芯(xin)通過電流時,在(zai)其周圍產(chan)生磁(ci)(ci)力(li)線,磁(ci)(ci)力(li)線與通過線芯(xin)的電流大小成正比,若使用鐵(tie)件等(deng)導磁(ci)(ci)材料,根(gen)據電磁(ci)(ci)感應(ying)可知(zhi),將在(zai)鐵(tie)件中產(chan)生渦(wo)流使電纜發熱,甚至燒(shao)壞電纜。所以不可使用鐵(tie)件作(zuo)單芯(xin)交(jiao)流電纜的固(gu)定夾具。
10、以下(xia)的熱縮(suo)電纜頭的附件(jian)的更大(da) 特點(dian)和(he)優點(dian)是(shi)什(shen)么(me)?
答(da):熱縮(suo)(suo)附件(jian)的(de)更大 特(te)點(dian)是(shi)用(yong)應力(li)管代替傳統(tong)的(de)應力(li)錐,它不僅簡化(hua)了(le)施工(gong)工(gong)藝(yi),還縮(suo)(suo)小了(le)接頭(tou)的(de)終端的(de)尺(chi)寸,安(an)裝方便,省時省工(gong),性能優越,節約金屬。熱縮(suo)(suo)電纜附件(jian)集(ji)灌注式和干(gan)包式為一(yi)體,集(ji)合了(le)這兩(liang)種附件(jian)的(de)優點(dian)。
11、電纜(lan)敷設前應進行哪些檢查工作?
答(da):(1)支架應齊全、油(you)漆完整。(2)電(dian)(dian)纜(lan)(lan)(lan)型號(hao)、電(dian)(dian)壓、規格符合(he)設(she)計。(3)電(dian)(dian)纜(lan)(lan)(lan)絕緣良好(hao),當對油(you)紙電(dian)(dian)纜(lan)(lan)(lan)的密封有(you)懷疑時,應進(jin)行(xing)受潮(chao)判斷;直埋電(dian)(dian)纜(lan)(lan)(lan)與小底電(dian)(dian)纜(lan)(lan)(lan)應經直流(liu)耐壓試(shi)難合(he)格;充油(you)電(dian)(dian)纜(lan)(lan)(lan)的油(you)樣(yang)應試(shi)驗合(he)格。(4)充油(you)電(dian)(dian)纜(lan)(lan)(lan)的油(you)壓不宜低于1.47MPa。
11、交聯(lian)熱收縮電纜附件有哪些優點?
答:這是一(yi)種新型材(cai)料,它與現在其他類型附件比較(jiao)具(ju)有電氣性能優越、體積(ji)小(xiao)、質量(liang)小(xiao)、安(an)裝簡便(bian)、材(cai)料配套等優點,另外(wai)還具(ju)有耐氣候、抗污穢性、阻燃自熄(xi)等能力。
12、對油紙絕(jue)(jue)緣電力電纜密封有懷疑時,如何用較簡單的(de)辦法檢查電纜絕(jue)(jue)緣紙是否受(shou)潮?
答:把電(dian)纜(lan)絕緣紙點燃或放入150℃左右的(de)電(dian)纜(lan)油(you)中檢查(cha),無“嘶(si)嘶(si)”聲或白色(se)泡沫出現,說明未受潮。
13、電纜標(biao)志牌(pai)應(ying)注明什么(me)內容?編寫有何(he)要(yao)求?
答:標志牌上應(ying)(ying)注(zhu)明電(dian)纜(lan)(lan)線路設計編號、電(dian)纜(lan)(lan)型號、規格及始點,并聯使用的電(dian)纜(lan)(lan)應(ying)(ying)有順序(xu)號。要求字跡清晰、不易脫落(luo)。
14、直(zhi)埋電(dian)纜的方(fang)位標志應(ying)設置在(zai)哪些位置?
答:在電纜(lan)兩端,電纜(lan)直線段(duan)50~100m處電纜(lan)接(jie)頭幾電纜(lan)改(gai)變方(fang)向(xiang)的彎角處。
15、制作(zuo)電纜接頭用的黃臘綢帶、黑玻(bo)璃漆帶、無堿玻(bo)璃絲帶等,施工前如何進行排潮處理?
答:(1)恒溫干燥法(fa):將(jiang)絕緣帶卷成直徑(jing)為25~30mm小卷,放入(ru)(ru)110~120℃恒溫干燥箱(xiang)內烘4~5h,冷(leng)卻干取出,放入(ru)(ru)干燥的(de)密封(feng)筒內。(2)油浸排潮法(fa):將(jiang)絕緣帶小卷放入(ru)(ru)恒溫在120~130℃的(de)電纜油中,離鍋底保持30mm距離,經一(yi)定時間后油面不再產生泡沫后取出,裝入(ru)(ru)貯有電纜油的(de)桶(tong)中,油位應超(chao)過所(suo)有裝入(ru)(ru)的(de)物體(ti)并(bing)將(jiang)其密封(feng)。
16、電纜(lan)外(wai)護(hu)層的作用是(shi)什(shen)么?
答:保護內護層(ceng)不受機(ji)械損(sun)傷和化(hua)學腐(fu)蝕,增強機(ji)械強度。
17、室外電纜(lan)溝應符(fu)合哪些要求?
答(da):電纜溝上(shang)部應(ying)比地面稍高,加(jia)蓋(gai)用混凝(ning)土(tu)制作的(de)蓋(gai)板,電纜應(ying)平敷(fu)在支架上(shang),有良好的(de)排水管。
18、電纜內護層的(de)作用是什么?
答(da);使絕緣(yuan)層不(bu)會與水、空氣或其他(ta)物體接觸,防止絕緣(yuan)受(shou)潮和絕緣(yuan)層不(bu)受(shou)機械傷(shang)害。
19、使(shi)用(yong)鋼絲鉗(qian)時應注意些什么(me)?
答:使(shi)用前(qian),一定要(yao)檢(jian)查(cha)絕緣柄的(de)絕緣是否完好無損,使(shi)用時不(bu)可用鋼絲鉗剪切(qie)超過規格所允(yun)許的(de)金屬線材,并禁止用鋼絲鉗代替錘子敲打(da)工(gong)具,以(yi)免損壞。
20、什(shen)么叫(jiao)絕緣強度?
答(da):絕緣(yuan)物質在電(dian)場中,當電(dian)場強度增大到(dao)某一極限(xian)時就會被(bei)擊穿,這個導致(zhi)絕緣(yuan)擊穿的(de)電(dian)場強度稱為絕緣(yuan)強度。
22、對電纜導體連接點的機(ji)械強(qiang)度有何(he)要(yao)求?
答:連接點的(de)(de)機械強(qiang)(qiang)(qiang)度,一般(ban)低于電纜導(dao)體(ti)本(ben)身的(de)(de)抗(kang)拉強(qiang)(qiang)(qiang)度,對(dui)于固定敷設的(de)(de)電力電纜,其連接點的(de)(de)抗(kang)拉強(qiang)(qiang)(qiang)度要(yao)求不低于導(dao)體(ti)本(ben)身抗(kang)拉強(qiang)(qiang)(qiang)度的(de)(de)60%。
23、電力(li)電纜的(de)絕緣層材(cai)料應具備哪些主要性能?
答;應具備(bei)下列(lie)主要(yao)性能:(1)高的擊穿強(qiang)(qiang)度(du)(du);(2)低的介質損(sun)耗;(3)相當(dang)高的絕緣電(dian)(dian)阻;(4)優良的耐放(fang)電(dian)(dian)性能;(5)具有一定(ding)的柔軟性和機械強(qiang)(qiang)度(du)(du);(6)絕緣性能長期穩定(ding)。
24、機械敷設電纜時(shi),牽引強度有何(he)規定?
答:對于銅芯電(dian)(dian)纜(lan)(lan),當牽(qian)引(yin)頭部時,允(yun)許(xu)牽(qian)引(yin)強(qiang)度為70N/cm;對于鋁(lv)芯電(dian)(dian)纜(lan)(lan),當牽(qian)引(yin)頭部時,允(yun)許(xu)牽(qian)引(yin)強(qiang)度為40N/cm;若利用鋼(gang)絲網套(tao)(tao)牽(qian)引(yin)時,鉛(qian)護套(tao)(tao)電(dian)(dian)纜(lan)(lan)允(yun)許(xu)強(qiang)度為10N/cm;鉛(qian)護套(tao)(tao)電(dian)(dian)纜(lan)(lan)為40N/cm。
25、對電纜保(bao)護管有(you)何(he)規定?
答:(1)電(dian)纜(lan)(lan)需要穿保護管(guan)(guan)敷設時,管(guan)(guan)子(zi)內(nei)徑(jing)不應小于(yu)電(dian)纜(lan)(lan)外徑(jing)的(de)1.5倍(bei),混(hun)凝土管(guan)(guan)、陶土管(guan)(guan)、石棉、水泥(ni)管(guan)(guan)的(de)內(nei)徑(jing)不應小于(yu)100mm;
(2)電(dian)纜管的彎曲半徑(jing)應符合所穿入(ru)電(dian)纜彎曲半徑(jing)的規(gui)定;
(3)每根管子最多不應超過(guo)三個彎(wan)頭,直角彎(wan)不應多于2個。
26、如(ru)何測(ce)量電纜(lan)護(hu)套的外徑?
答:在護套(tao)圓周上(shang)均勻(yun)分布(bu)的(de)五點處,測量護套(tao)外(wai)徑(jing)和其(qi)平均值,其(qi)平均外(wai)徑(jing)既為護套(tao)的(de)外(wai)徑(jing)。
27、不同截面的銅(tong)芯電纜如何連(lian)接?
答(da):不同(tong)截(jie)面(mian)的銅芯電纜連(lian)接(jie),可采用(yong)(yong)開口弱背(bei)銅接(jie)管(guan),以(yi)錫焊法連(lian)接(jie),也可用(yong)(yong)純(chun)銅棒按不同(tong)的截(jie)面(mian)要求連(lian)接(jie)成銅接(jie)管(guan),以(yi)壓接(jie)法連(lian)接(jie)。
28、簡(jian)述10KV交聯(lian)電纜熱縮式(shi)制作戶內終端(duan)頭的過程?
答;(1)準(zhun)備(bei)階段:檢(jian)查熱(re)縮電(dian)纜(lan)附件是(shi)否(fou)齊備(bei),型號是(shi)否(fou)相(xiang)配,檢(jian)查并確認電(dian)纜(lan)有無潮氣后,檢(jian)查電(dian)纜(lan)。
(2)切除多余電(dian)纜(lan),根據現場情況決定電(dian)纜(lan)長度。
(3)剝除護(hu)層。
(4)焊(han)接(jie)接(jie)地線,將接(jie)地線焊(han)接(jie)在鋼(gang)帶(dai)上。
(5)填充三叉(cha)口及繞(rao)包密封膠(jiao)。
(6)安裝三芯分支護套(tao),將護套(tao)套(tao)入根部,從中(zhong)部開始收(shou)縮,先(xian)往根部,再往指部。
(7)剝(bo)銅 帶(dai)和(he)外半導(dao)電層,剝(bo)切三芯分支套口20mm以上的銅帶(dai),嚴(yan)禁損傷主(zhu)絕緣,清除(chu)干凈(jing)半導(dao)電層。
(8)安裝應力管,管口端部分支(zhi)套對(dui)接后熱縮(suo)。
(9)安裝接線端子。
(10)安裝絕緣(yuan)管。
(11)安裝密封管。
(12)核(he)相后安裝相色管(guan)。
29、戶(hu)內、戶(hu)外預制(zhi)式終端安裝(zhuang)步驟有哪些?
答:(1) 將電纜按預定位置(zhi)就(jiu)位、固定、清潔表面,參照說(shuo)明書剝除外護套(tao)(tao),如有特殊需要,外護套(tao)(tao)剝切長度可調整,分別由銅帶、外護套(tao)(tao)鎧裝引出2組地(di)線。
(2) 由(you)(you)(you)外(wai)護套口向上量(liang)取(qu)需要尺寸,切除(chu)多(duo)(duo)余(yu)(yu)電(dian)纜,套入熱縮三(san)指(zhi)套至三(san)叉(cha)口根部由(you)(you)(you)中間(jian)加熱收縮,由(you)(you)(you)指(zhi)套上口向上量(liang)取(qu)規定尺寸(35kv為(wei)350~380mm)。去(qu)掉多(duo)(duo)余(yu)(yu)銅帶(保留20mm),再保留半導體預定位置(zhi),壓接出線(xian)端子(zi)密封。
30、電(dian)線電(dian)纜的應用主要分為三(san)大類 :
(1)、電力系統
電(dian)(dian)(dian)(dian)力系統采用的電(dian)(dian)(dian)(dian)線(xian)(xian)電(dian)(dian)(dian)(dian)纜(lan)(lan)產品主(zhu)要(yao)有架空(kong)(kong)裸電(dian)(dian)(dian)(dian)線(xian)(xian)、匯流(liu)排(母(mu)線(xian)(xian))、電(dian)(dian)(dian)(dian)力電(dian)(dian)(dian)(dian)纜(lan)(lan)(塑(su)(su)料線(xian)(xian)纜(lan)(lan)、油紙力纜(lan)(lan)(基本被塑(su)(su)料電(dian)(dian)(dian)(dian)力電(dian)(dian)(dian)(dian)纜(lan)(lan)代替(ti))、橡套線(xian)(xian)纜(lan)(lan)、架空(kong)(kong)絕緣電(dian)(dian)(dian)(dian)纜(lan)(lan))、分(fen)(fen)支電(dian)(dian)(dian)(dian)纜(lan)(lan)(取代部(bu)分(fen)(fen)母(mu)線(xian)(xian))、電(dian)(dian)(dian)(dian)磁線(xian)(xian)以及(ji)電(dian)(dian)(dian)(dian)力設(she)備(bei)用電(dian)(dian)(dian)(dian)氣裝備(bei)電(dian)(dian)(dian)(dian)線(xian)(xian)電(dian)(dian)(dian)(dian)纜(lan)(lan)等。
(2)、信(xin)息傳輸系統
用于信息傳輸系統的電(dian)(dian)(dian)(dian)(dian)線電(dian)(dian)(dian)(dian)(dian)纜(lan)(lan)主(zhu)要有市話電(dian)(dian)(dian)(dian)(dian)纜(lan)(lan)、電(dian)(dian)(dian)(dian)(dian)視電(dian)(dian)(dian)(dian)(dian)纜(lan)(lan)、電(dian)(dian)(dian)(dian)(dian)子(zi)線纜(lan)(lan)、射頻電(dian)(dian)(dian)(dian)(dian)纜(lan)(lan)、光纖纜(lan)(lan)、數據電(dian)(dian)(dian)(dian)(dian)纜(lan)(lan)、電(dian)(dian)(dian)(dian)(dian)磁線、電(dian)(dian)(dian)(dian)(dian)力通訊或其他復合電(dian)(dian)(dian)(dian)(dian)纜(lan)(lan)等。
(3)、機械設備、儀器儀表系統
此(ci)部(bu)分除(chu)架空(kong)裸電(dian)(dian)線(xian)(xian)外幾乎其他(ta)所有產品均有應用,但主要(yao)是電(dian)(dian)力電(dian)(dian)纜(lan)(lan)、電(dian)(dian)磁(ci)線(xian)(xian)、數據電(dian)(dian)纜(lan)(lan)、儀(yi)器(qi)儀(yi)表(biao)線(xian)(xian)纜(lan)(lan)等。
31、電(dian)(dian)線電(dian)(dian)纜產品(pin)主要分為五(wu)大類:
(1)、裸(luo)電線及(ji)裸(luo)導體制品 本類產品的(de)主(zhu)要(yao)特(te)征是(shi)(shi):純的(de)導體金屬,無絕緣(yuan)及(ji)護套層,如(ru)(ru)鋼芯鋁絞(jiao)(jiao)線、銅(tong)鋁匯流排、電力(li)機車線等;加工(gong)工(gong)藝主(zhu)要(yao)是(shi)(shi)壓力(li)加工(gong),如(ru)(ru)熔煉、壓延(yan)、拉制、絞(jiao)(jiao)合(he)/緊(jin)壓絞(jiao)(jiao)合(he)等;產品主(zhu)要(yao)用在城郊、農村、用戶(hu)主(zhu)線、開關柜等。
(2)、電力(li)電纜本(ben)類產品主(zhu)要(yao)特(te)征是:在導體外擠(繞(rao))包絕緣(yuan)層(ceng),如架空絕緣(yuan)電纜,或(huo)幾(ji)芯(xin)(xin)絞(jiao)(jiao)合(he)(對應電力(li)系統的相線(xian)、零線(xian)和地(di)線(xian)),如二芯(xin)(xin)以上架空絕緣(yuan)電纜,或(huo)再增加護(hu)套(tao)層(ceng),如塑料/橡套(tao)電線(xian)電纜。主(zhu)要(yao)的工藝(yi)技術有拉制、絞(jiao)(jiao)合(he)、絕緣(yuan)擠出(繞(rao)包)、成纜、鎧裝、護(hu)層(ceng)擠出等(deng),各種產品的不同工序組合(he)有一定(ding)區(qu)別。
產(chan)品主(zhu)要用在(zai)發、配(pei)、輸、變、供(gong)電線(xian)路中(zhong)的強電電能傳輸,通過的電流大(幾(ji)十(shi)安至幾(ji)千安)、電壓(ya)高(220V至500kV及以上)。
(3)、電氣裝備用(yong)(yong)電線(xian)電纜該類產品主要(yao)特征是:品種規格繁多,應用(yong)(yong)范圍廣泛,使用(yong)(yong)電壓(ya)在1kV及以下較多,面對特殊(shu)場合(he)不斷(duan)衍生新的產品,如耐(nai)(nai)火線(xian)纜、阻燃線(xian)纜、低煙無鹵(lu)/低煙低鹵(lu)線(xian)纜、防白蟻、防老(lao)鼠線(xian)纜、耐(nai)(nai)油/耐(nai)(nai)寒/耐(nai)(nai)溫(wen)/耐(nai)(nai)磨(mo)線(xian)纜、醫用(yong)(yong)/農用(yong)(yong)/礦用(yong)(yong)線(xian)纜、薄(bo)壁(bi)電線(xian)等。
(4)、通訊(xun)(xun)電纜(lan)(lan)及光纖(簡略介紹)隨(sui)著近二十(shi)多年(nian)來,通訊(xun)(xun)行業的(de)(de)飛速發展(zhan)(zhan),產(chan)品也有(you)驚(jing)人的(de)(de)發展(zhan)(zhan)速度。從過去(qu)的(de)(de)簡單的(de)(de)電話電報線纜(lan)(lan)發展(zhan)(zhan)到幾千對(dui)的(de)(de)話纜(lan)(lan)、同軸纜(lan)(lan)、光纜(lan)(lan)、數據電纜(lan)(lan),甚至組合通訊(xun)(xun)纜(lan)(lan)等。
該類(lei)產品結構尺(chi)寸通常較小(xiao)而均勻,制造精(jing)度要求高。
(5)、電磁線(xian)(繞組線(xian))主要用于各種電機、儀器(qi)儀表等。
電(dian)線電(dian)纜的(de)衍生/新(xin)產品(pin)
電(dian)(dian)線電(dian)(dian)纜的衍生(sheng)/新產(chan)品(pin)(pin)主要(yao)是因應用(yong)場(chang)合、應用(yong)要(yao)求不(bu)同及裝備(bei)的方便(bian)性和降低(di)裝備(bei)成本(ben)等的要(yao)求,而采用(yong)新材(cai)料、特殊材(cai)料、或(huo)改變(bian)產(chan)品(pin)(pin)結構(gou)、或(huo)提高工藝要(yao)求、或(huo)將(jiang)不(bu)同品(pin)(pin)種(zhong)的產(chan)品(pin)(pin)進行組合而產(chan)生(sheng)。
采用(yong)不同材料(liao)如阻燃線纜(lan)(lan)、低(di)煙無(wu)鹵/低(di)煙低(di)鹵線纜(lan)(lan)、防(fang)白蟻(yi)、防(fang)老鼠線纜(lan)(lan)、耐(nai)油(you)/耐(nai)寒/耐(nai)溫(wen)線纜(lan)(lan)等;
改變產品結構如(ru):耐火電纜(lan)等;
提高工藝要求如(ru):醫(yi)用線纜等;
組合產(chan)品如:OPGW等;
方(fang)便安裝和降(jiang)低裝備(bei)成(cheng)本如:預制分(fen)支電(dian)纜等。
32、母線(xian)裝置施工完,應(ying)進行哪些檢(jian)查?
答(da):應進行下列檢查:
(1)金屬(shu)構件的(de)加工、配制(zhi)、焊接螺接應符合(he)規定(ding);
(2)各部螺栓(shuan)、墊圈、開口銷等零部件應齊全可靠(kao);
(3)母線配制(zhi)及(ji)安裝架應符合規定,相間(jian)及(ji)對地電氣距離(li)符合要求(qiu);
(4)瓷(ci)件、鐵件及膠(jiao)合處(chu)應完整,充(chong)油套管應無滲油,油位(wei)正常;
(5)油(you)漆完整,相(xiang)色(se)正確,接地(di)良(liang)好(hao)。
33、在35kv及以下電(dian)力電(dian)纜接頭中,改善其(qi)護套(tao)斷(duan)開(kai)處電(dian)場分布的方(fang)(fang)法有幾(ji)種(zhong)(請列出(chu)五種(zhong)),并簡述(shu)其(qi)方(fang)(fang)法。
答:(1)脹喇(la)叭(ba)口(kou):在鉛包割斷(duan)處把鉛包邊(bian)緣撬起,成喇(la)叭(ba)狀(zhuang),其邊(bian)緣應光滑(hua)、圓整、對稱。
(2)預留(liu)統(tong)包(bao)絕(jue)緣:在(zai)鉛包(bao)切口至(zhi)電纜芯線分開點之間留(liu)有(you)一段(duan)統(tong)包(bao)絕(jue)緣紙。
(3)切除半(ban)(ban)導(dao)電(dian)紙:將半(ban)(ban)導(dao)電(dian)紙切除到喇叭口以下。
(4)包(bao)繞(rao)應(ying)力(li)錐(zhui):用絕緣包(bao)帶和(he)導電金屬材料包(bao)成錐(zhui)形,人(ren)為地將屏蔽層擴大,以改善電場分布。
(5)等(deng)電位法:對于干(gan)包(bao)型或交聯聚乙烯電纜頭,在各(ge)線芯概況絕緣表面(mian)上包(bao)一(yi)(yi)段(duan)金(jin)屬(shu)帶(dai),并將其連接(jie)在一(yi)(yi)起。
(6)裝(zhuang)設應力控制(zhi)管:對(dui)于35kv及發下熱縮管電(dian)纜頭,首(shou)先從線芯銅屏蔽層末端(duan)方向經半(ban)導(dao)體帶至線芯絕緣概況包繞2層半(ban)導(dao)體帶,然(ran)后將(jiang)相(xiang)應規格折應力管,套在銅屏蔽的末端(duan)處,熱縮成形。
34、電纜支架(jia)的加工(gong)應符合(he)哪些要求?
答:(1)鋼材(cai)應(ying)(ying)平直,無明(ming)顯扭曲,下料誤差應(ying)(ying)在5mm范圍內(nei),切口應(ying)(ying)無卷邊,毛剌;
(2)支(zhi)架(jia)應焊接牢固,無顯蓍變(bian)形(xing),各橫撐間(jian)的垂(chui)直凈距(ju)與設計偏差不應大(da)于5mm;
(3)金屬支架必須進行防腐(fu)處理(li),位于濕熱、鹽、霧以及有化學腐(fu)蝕地區時,應根據(ju)設計作(zuo)特殊的防腐(fu)處理(li)。
35、列舉出你熟悉(xi)的電纜架(jia)。
答:拼焊式(shi)E型(xing)架(jia)(jia)、裝(zhuang)配式(shi)E型(xing)架(jia)(jia)、橋式(shi)電(dian)(dian)纜(lan)架(jia)(jia)、電(dian)(dian)纜(lan)托架(jia)(jia)、掛鉤式(shi)支(zhi)架(jia)(jia)、單根電(dian)(dian)纜(lan)支(zhi)架(jia)(jia)等。
36、敷(fu)設電纜應滿足哪些(xie)要求(qiu)?
答:應滿足以(yi)下要求:
(1)安全(quan)運行方(fang)面,盡可能(neng)避(bi)免各種外來損壞,提高電(dian)纜(lan)線路的(de)供電(dian)可靠性;
(2)經濟方面,從(cong)投資最省(sheng)的方面考慮;
(3)施工(gong)方面,電纜線路(lu)的路(lu)徑必須便于旋工(gong)和(he)投(tou)運后的維修。
37、制作電纜終端(duan)頭或中間(jian)接頭的(de)絕緣材(cai)料有(you)哪些?
答:有絕(jue)緣膠、絕(jue)緣帶、絕(jue)緣管、絕(jue)緣手套、絕(jue)緣樹脂等。
38、簡述電纜(lan)頭制(zhi)(zhi)作的一(yi)般操(cao)作程序。答:(1)制(zhi)(zhi)作前的準備:包(bao)括○1閱讀安(an)裝說(shuo)明書;○2察看現場;○3備料(liao);○4電纜(lan)試潮(chao);○5制(zhi)(zhi)作前測(ce)試等。
(2)接頭的(de)制作過程:包(bao)括○1割(ge)斷多余電纜;○2電纜保護層的(de)剝切;○3導體連接;○4包(bao)繞絕(jue)(jue)緣(yuan)(或收縮管材);○5安(an)裝接頭外殼(ke);○6灌(guan)注(zhu)絕(jue)(jue)緣(yuan)劑;○7進行(xing)密封處理等。
(3)制(zhi)作(zuo)后電氣測試(shi)。
39、電(dian)纜保護管的加工應符合(he)哪些(xie)要求(qiu)?
答:(1)管口應*剌和尖銳楞角,管口宜做成(cheng)喇叭形。
(2)電(dian)纜(lan)管在彎制(zhi)后,不應有裂(lie)縫和顯著的凹(ao)癟現象,其彎扁程(cheng)度不宜大于管子外徑10%;電(dian)纜(lan)管的彎曲半徑不應小(xiao)于所穿入電(dian)纜(lan)的最(zui)小(xiao)允許彎曲半徑。
(3)金屬(shu)管應在(zai)外表涂(tu)防腐漆或(huo)瀝表,鍍鋅(xin)管鋅(xin)層剝(bo)落處也應涂(tu)以防腐漆。
40、電(dian)纜的排(pai)列符合(he)哪些(xie)要(yao)求?答(da):(1)電(dian)力(li)電(dian)纜和控纜不應(ying)配置(zhi)在同一層支架上(shang)。
(2)高、低壓電(dian)纜,強、弱電(dian)控纜應(ying)按須序分層配(pei)置,一般(ban)情況宜由(you)上(shang)而下,但在含有(you)35kv以(yi)上(shang)高壓電(dian)纜引入柜盤時(shi),為滿足彎曲半徑(jing),可由(you)下面上(shang)配(pei)置。
41、電(dian)纜溝內敷(fu)設電(dian)纜的方法是什么?
答:在(zai)電(dian)(dian)(dian)(dian)纜(lan)溝(gou)內敷設(she)電(dian)(dian)(dian)(dian)纜(lan)的方法與(yu)直(zhi)埋電(dian)(dian)(dian)(dian)纜(lan)的敷設(she)方法相仿,一(yi)般可將滑(hua)輪放在(zai)溝(gou)內,施(shi)放完畢,將電(dian)(dian)(dian)(dian)纜(lan)放于溝(gou)底或支(zhi)架上(shang),并在(zai)電(dian)(dian)(dian)(dian)纜(lan)上(shang)綁扎電(dian)(dian)(dian)(dian)纜(lan)標牌。
42、電纜(lan)敷設(she)的常用設(she)備有(you)哪(na)些?
答:(1)空氣壓縮機,主(zhu)要用來(lai)破壞路面,為以后敷設電纜(lan)作準備;
(2)電(dian)(dian)動卷揚機(ji)或(huo)電(dian)(dian)纜牽引機(ji),主要(yao)用來拖電(dian)(dian)纜;
(3)電纜輸送機(ji),配合牽引(yin)機(ji)使用來克服巨(ju)大(da)的摩擦力,減輕對電纜的損壞;
(4)電纜盤放線(xian)支架;
(5)滾輪裝置;
(6)防(fang)捻(nian) ,減鋼絲繩(sheng)出現的扭曲;
(7)電纜(lan)盤制(zhi)動裝置;
(8)張(zhang)力計。
43、電(dian)纜溝中(zhong)支(zhi)架安(an)裝(zhuang)距離的要求如何?答:電(dian)纜固(gu)定(ding)于(yu)(yu)電(dian)纜溝和隧道的墻上(shang),水平裝(zhuang)置時,當電(dian)纜外徑等于(yu)(yu)或小(xiao)于(yu)(yu)50mm時應(ying)每隔1m加(jia)一(yi)支(zhi)撐(cheng);外徑大于(yu)(yu)50mm的電(dian)纜每隔0.6m加(jia)一(yi)支(zhi)撐(cheng);排(pai)成三角形的單電(dian)纜,每隔1m應(ying)用(yong)綁帶扎牢,垂直裝(zhuang)置時,每隔1~1.5m加(jia)以固(gu)定(ding)。
44、如(ru)何處理電力電纜與控制電纜在同(tong)一托(tuo)架的安(an)裝(zhuang)?
答:電(dian)(dian)(dian)力電(dian)(dian)(dian)纜與控制電(dian)(dian)(dian)纜一般不(bu)應(ying)敷(fu)設在同一托(tuo)架內,當電(dian)(dian)(dian)纜較(jiao)少(shao)而將(jiang)控纜與電(dian)(dian)(dian)力電(dian)(dian)(dian)纜敷(fu)設在同一托(tuo)架內時,應(ying)用隔板隔開。
45、電纜隧道內如何裝設接(jie)地線?
答:隧道和(he)溝的(de)(de)全長應(ying)裝設連(lian)(lian)續的(de)(de)接(jie)地(di)線(xian),接(jie)地(di)線(xian)應(ying)和(he)所有(you)的(de)(de)支架相連(lian)(lian),兩頭和(he)接(jie)地(di)極連(lian)(lian)通。接(jie)地(di)線(xian)的(de)(de)規(gui)格(ge)應(ying)符(fu)合設計要求。電(dian)纜鉛(qian)包和(he)鎧(kai)裝除了有(you)絕緣要求外,應(ying)全部相互連(lian)(lian)接(jie)并和(he)接(jie)地(di)線(xian)相連(lian)(lian),電(dian)纜架和(he)接(jie)地(di)線(xian)均應(ying)涂防銹漆或鍍(du)鋅。
46、對于(yu)電纜孔洞的防火封堵有何要求?
答(da):對于(yu)較(jiao)大的電纜(lan)貫穿孔(kong)洞(dong)(dong),如(ru)電纜(lan)貫穿樓板處等,采用防火堵料(liao)(liao)封堵時(shi),應根(gen)據實(shi)際情(qing)況,先在電纜(lan)表面涂四至六(liu)層防火涂料(liao)(liao),長度自孔(kong)洞(dong)(dong)以下(xia)1.5m左右,再用耐火材料(liao)(liao)加工(gong)成具有(you)(you)一定強度的板托防火堵料(liao)(liao),保證封堵后牢固并便于(yu)更換(huan)電纜(lan)時(shi)拆裝,封堵密實(shi)無孔(kong)隙以有(you)(you)效地(di)堵煙堵火。
47、噴(pen)燈(deng)點(dian)火(huo)前應(ying)注意(yi)哪些檢查(cha)?
答:應進(jin)行下列各項檢查:
(1)打氣筒(tong)是否(fou)漏油(you)(you)或(huo)滲(shen)油(you)(you),油(you)(you)桶及噴嘴處是否(fou)漏油(you)(you)、漏氣;
(2)油桶內的油量是否超(chao)過油桶容量的3/4,加油的螺絲塞是否擰(ning)緊。
48、使用噴(pen)燈應注意(yi)哪些事項?
答(da):(1)噴燈更大(da) 注油(you)量為油(you)筒容積的3/4;
(2)開始打氣(qi)壓力不要(yao)太大,點燃后火焰由(you)黃變(bian)藍即可使用;
(3)周圍不得有(you)易燃(ran)物,空(kong)氣要流(liu)通;
(4)停用時(shi)先(xian)關(guan)閉調節開(kai)關(guan),火熄后,慢慢旋(xuan)松(song)油(you)孔蓋(gai)放氣,空氣放完后,要(yao)要(yao)旋(xuan)松(song)調節開(kai)關(guan),完全冷卻后再旋(xuan)松(song)孔蓋(gai);
(5)煤油(you)噴(pen)燈與汽油(you)噴(pen)燈要分開使(shi)用。
49、手動油壓(ya)鉗有(you)何(he)用途?如(ru)何(he)操作?
答(da):兩(liang)根(gen)導線的(de)(de)連(lian)接(jie)通常是(shi)將(jiang)兩(liang)導線端穿(chuan)入相同材(cai)料制成的(de)(de)壓(ya)(ya)(ya)管中,用(yong)壓(ya)(ya)(ya)接(jie)鉗(qian)擠(ji)壓(ya)(ya)(ya)數個坑(keng),使導線連(lian)接(jie)在一(yi)(yi)起(qi),壓(ya)(ya)(ya)接(jie)時(shi),手(shou)(shou)柄(bing)向(xiang)上抬起(qi)時(shi),柱塞(sai)向(xiang)外移(yi)(yi)(yi)動(dong),進(jin)油(you)(you)閥(fa)下(xia)腔產生真空,油(you)(you)箱內的(de)(de)油(you)(you)進(jin)入柱塞(sai)腔。手(shou)(shou)柄(bing)下(xia)壓(ya)(ya)(ya)時(shi),柱塞(sai)向(xiang)內移(yi)(yi)(yi)動(dong),油(you)(you)受(shou)壓(ya)(ya)(ya)后(hou),使進(jin)油(you)(you)閥(fa)關閉,打開出(chu)油(you)(you)閥(fa),使油(you)(you)壓(ya)(ya)(ya)進(jin)入液壓(ya)(ya)(ya)缸,推動(dong)活塞(sai)和陽模,陽、陰模之(zhi)間(jian)放有壓(ya)(ya)(ya)接(jie)管,當壓(ya)(ya)(ya)接(jie)被擠(ji)壓(ya)(ya)(ya)的(de)(de)坑(keng)深到(dao)一(yi)(yi)定值時(shi),開啟回油(you)(you)閥(fa),活塞(sai)自動(dong)返回,壓(ya)(ya)(ya)完一(yi)(yi)個坑(keng)后(hou),移(yi)(yi)(yi)動(dong)壓(ya)(ya)(ya)鉗(qian),再壓(ya)(ya)(ya)下(xia)一(yi)(yi)個。
50、常(chang)用低壓電(dian)力(li)電(dian)纜(lan)按(an)絕(jue)緣和(he)保護層的不同,主要(yao)可分為哪(na)幾類?
答:(1)油浸紙絕緣鉛包(或鋁包)電力電纜;
(2)不滴流油浸紙絕緣(yuan)電力電纜(lan);
(3)聚氯乙烯(xi)絕緣聚氯乙烯(xi)護套電(dian)力電(dian)纜;
(4)交聯聚氯(lv)乙(yi)烯(xi)絕緣聚乙(yi)烯(xi)護套電力電纜;
(5)交(jiao)聯聚氯(lv)乙烯絕(jue)緣聚氯(lv)乙烯護套電力電纜;
(6)橡(xiang)皮絕緣電力(li)電纜。
51、常用絕緣(yuan)材(cai)料的類別哪些?舉例說明?
答:(1)無(wu)機絕緣材料(liao):有云母、石(shi)棉、大理石(shi)、瓷(ci)器(qi)、玻(bo)璃(li)等;
(2)有(you)機絕緣材料:有(you)樹脂、橡膠(jiao)、紙(zhi)、麻、棉紗等;
(3)混合絕緣材料(liao):用以上絕緣材料(liao)加(jia)工而成型的名種(zhong)絕緣材料(liao)。
52、在哪種情況下采用排管敷設?有什(shen)么優(you)點?
答:排管敷設一般用在與其他建(jian)筑物(wu)、公路(lu)或鐵路(lu)相交叉的地方,有時(shi)也在建(jian)筑物(wu)密集(ji)區內采用。主要優點是占地少,能承受大的荷重,電纜(lan)相互(hu)間互(hu)不影響(xiang),比較安(an)全。
53、何謂電纜長期允許載流量?
答:電纜(lan)長期允(yun)許載流(liu)量是指在(zai)電纜(lan)內通過規定電流(liu)時,在(zai)熱穩定后,電纜(lan)導(dao)體達到長期允(yun)許工作溫度時的電流(liu)數值。
54、決(jue)定(ding)電纜長期允許載流量的因素有哪些?
答:有以(yi)下三(san)個因素決定:
(1)電纜的長期容許(xu)工作溫(wen)度;
(2)電纜本身(shen)的散(san)熱性能;
(3)電纜裝置(zhi)情況及周(zhou)圍環境的散(san)熱條件(jian)。
55、電纜的敷設方式有幾種(zhong)?
答:有以下幾種:
(1)直埋在(zai)地下(xia);
(2)安裝在電纜溝(gou)內;
(3)安(an)裝在(zai)地(di)下隧(sui)道內(nei);
(4)安(an)裝在建筑物(wu)內部墻上或天棚上;
(5)安裝在橋架(jia)上;
(6)敷設在排管內;
(7)敷設在水底。
56、如何(he)進行電(dian)纜管(guan)的連接(jie)工作?
答:電纜管連接時(shi),必須(xu)用扣和管接頭連接,如采用焊接時(shi),不能直接對焊,連接處要套上一段粗管再進行焊接,以免焊渣(zha)掉入管內。
57、制作電纜頭(tou)時,對上下扳彎(wan)電纜芯線有何要求?
答:扳彎線(xian)芯(xin)(xin)時,不得損(sun)(sun)傷紙(zhi)絕(jue)緣,芯(xin)(xin)線(xian)的(de)彎曲半(ban)徑不得小(xiao)于電纜線(xian)芯(xin)(xin)的(de)10倍。制(zhi)作時要特別小(xiao)心,應使(shi)線(xian)芯(xin)(xin)彎曲部(bu)分(fen)均勻受力,否則極易損(sun)(sun)傷絕(jue)緣紙(zhi)。
58、簡(jian)述塑料(liao)電纜的(de)熱收縮密封法。
答:熱(re)(re)縮(suo)法適用(yong)于(yu)中、低壓橡、塑(su)電纜(lan)接頭和(he)終端頭的密封,也可(ke)適用(yong)于(yu)不滴流和(he)黏性浸漬絕緣電纜(lan)。采用(yong)交聯聚(ju)乙烯型和(he)硅橡膠型兩(liang)大類遇熱(re)(re)后能(neng)均勻收縮(suo)的熱(re)(re)收縮(suo)管(guan)。將這種管(guan)材套于(yu)預定的粘(zhan)合密封部位,并在粘(zhan)和(he)部位涂上熱(re)(re)熔(rong)膠,當加(jia)熱(re)(re)到一定溫度后,熱(re)(re)縮(suo)管(guan)將收縮(suo),同時熱(re)(re)熔(rong)膠熔(rong)化(hua),待自然(ran)冷卻后即形(xing)成一道良好的密封封層。
59、用電動彎管機彎制(zhi)電纜保護(hu)管時應注意(yi)什么?
答:(1)彎管(guan)機應由了解其性能并熟悉操作知識(shi)的人員操作;
(2)使(shi)用前必須(xu)進行檢查,按鈕(niu)、操作把手、行程(cheng)開關應(ying)完好,彎管機必須(xu)可靠接地;
(3)選(xuan)用符合要(yao)求(qiu)的模具,確定(ding)好所(suo)需要(yao)的彎(wan)曲半(ban)徑(jing);
(4)施工場地周(zhou)圍,應有充足的活動范(fan)圍;
(5)使用(yong)時待空轉正常后(hou),方(fang)可帶(dai)負荷工作,運行中(zhong),嚴(yan)禁用(yong)手腳接觸其轉動部分(fen);
(6)工作完畢(bi)應及時停電(dian),釋放油(you)壓。
60、電纜清冊的內(nei)容及電纜編號的含義是(shi)什么?
答(da):電纜(lan)(lan)(lan)(lan)清冊是(shi)施放電纜(lan)(lan)(lan)(lan)和指導施工的(de)(de)依據,運行維護的(de)(de)檔案(an)資料(liao)。應列入每根電纜(lan)(lan)(lan)(lan)的(de)(de)編號(hao)、起(qi)始點(dian)、型號(hao)、規格、長度(du),并分類統計出總長度(du),控纜(lan)(lan)(lan)(lan)還應列出每根電纜(lan)(lan)(lan)(lan)的(de)(de)備用(yong)芯。
電(dian)纜編號(hao)是識別電(dian)纜的標志,故要(yao)求(qiu)全廠編號(hao)不重復,并且有一定的含義和規律(lv),能表(biao)達電(dian)纜的特征。
61、電(dian)纜目前采(cai)用的敷設方法可分(fen)為幾(ji)類?
答(da):(1)人(ren)工敷設,即采用人(ren)海戰術,在(zai)一(yi)人(ren)或多(duo)人(ren)協調指揮下,按規定進行(xing)敷設;
(2)機(ji)械化敷設,即采(cai)用滾輪(lun)、牽(qian)引(yin)器、輸送機(ji),通(tong)過一同步電源進行控(kong)制,比較(jiao)安(an)全;
(3)人(ren)工和機械相結合,有些現場由于(yu)轉彎較(jiao)多,施(shi)工難(nan)度大,全用(yong)機械較(jiao)困難(nan),所以采用(yong)此法(fa)。
62、控制二次回路接線(xian)應符(fu)合(he)哪些要求(qiu)?
答:(1)按圖施工接線(xian)正確;
(2)導(dao)線的電氣(qi)連(lian)接應牢固可靠(kao);
(3)盤柜內(nei)的導(dao)線不(bu)應有接(jie)頭(tou),導(dao)線芯線應無損傷(shang);
(4)電纜(lan)芯線端(duan)部應(ying)標明其回路(lu)編(bian)號,編(bian)號應(ying)正確,字跡清晰(xi)且不易脫色;
(5)配線應整齊(qi)、清(qing)晰(xi)、美觀(guan),導(dao)線絕(jue)緣應良好(hao)、無損(sun);
(6)每個接(jie)線(xian)(xian)端子(zi)的每側接(jie)線(xian)(xian)宜為一根,最(zui)多不(bu)得(de)超過兩根。
63、電(dian)纜排管有何要求?
答(da):(1)排管頂部至地面距(ju)離,在(zai)廠(chang)房內為0.2m,人(ren)行道下為0.5m,一般地區為0.7m;
(2)在變更方向及分支(zhi)處均(jun)應裝置排(pai)管(guan)井坑(keng),長度超過30mm時也應加設井坑(keng);
(3)井坑(keng)深度不(bu)小于0.8m,人孔直徑(jing)不(bu)小于0.7mm;
(4)排管應有傾向井坑0.5%~1%的排水(shui)坡度(du)。
64、對于(yu)電(dian)纜(lan)導體連接點的電(dian)阻有何要求?
答:要求連(lian)接點(dian)的(de)電阻小而且(qie)穩定,連(lian)接點(dian)的(de)電阻與相(xiang)同長度、相(xiang)同截(jie)面的(de)導(dao)體之比值,對(dui)(dui)于(yu)新安裝的(de)終端頭和中(zhong)間頭,應不大于(yu)1;對(dui)(dui)于(yu)運(yun)行中(zhong)的(de)終端頭和中(zhong)間頭這個(ge)比值不應大于(yu)1.2。
65、電(dian)纜接頭和(he)中間頭的設(she)計應滿足(zu)哪些(xie)要求?
答(da):應滿足的(de)要求有(you):
(1)耐(nai)壓強度高,導體連接好;
(2)機械(xie)強度大,介質損失(shi)小;
(3)結構簡單,密封性強。
66、什么是電纜(lan)故障?有幾種(zhong)常(chang)見的(de)類型(xing)?
答:電纜故障(zhang)是(shi)指(zhi)電纜在預防性試驗時(shi)發生絕緣擊穿或在運行中,因(yin)絕緣擊穿、導線(xian)(xian)燒斷(duan)等(deng)而迫(po)使(shi)電纜線(xian)(xian)路停(ting)電的(de)故障(zhang)。常見的(de)故障(zhang)有(you)接地故障(zhang)、短路故障(zhang)、斷(duan)線(xian)(xian)故障(zhang)、閃絡性故障(zhang)和(he)混合型故障(zhang)等(deng)。
67、如何處理電纜線路的單(dan)相接地故(gu)障(zhang)?
答:電(dian)纜(lan)(lan)線路單相接地故(gu)(gu)障一(yi)般(ban)來(lai)說,電(dian)纜(lan)(lan)導體的(de)損傷只是局部的(de),如果屬于機械損傷,而故(gu)(gu)障點(dian)附近的(de)土壤又較干燥時,一(yi)般(ban)可(ke)進行局部修(xiu)理,加(jia)添一(yi)只假(jia)接頭,即不將電(dian)纜(lan)(lan)芯鋸斷(duan),僅(jin)將故(gu)(gu)障點(dian)絕緣加(jia)強后密封(feng)即可(ke)。
68、電力電纜在敷(fu)設前應進行哪些試驗和檢查(cha)?
答:敷設前應檢查(cha)電纜的型號、規格及(ji)長度(du)是否符(fu)合要求,是否有外力損傷,低壓電纜用(yong)1000V兆(zhao)歐表(biao)遙(yao)測絕緣電阻,阻值一般不(bu)低于(yu)10MΩ,高(gao)壓電纜用(yong)2500V兆(zhao)歐表(biao)搖測阻值一般不(bu)抵于(yu)400MΩ。
69、主廠房(fang)內敷設電纜時一般(ban)應注意什么?
答(da):在主廠房內敷設電(dian)纜時一般應注(zhu)意:
(1)凡引(yin)至集控室的控制電纜宜(yi)架空(kong)敷設(she);
(2)6KV電纜宜用(yong)隧道或排管敷(fu)設,地下(xia)水位高處(chu)亦可架空(kong)或用(yong)排管敷(fu)設;
(3)380V電(dian)纜當兩(liang)端(duan)(duan)電(dian)纜在(zai)零米時宜用(yong)隧道(dao)、溝或排管,當一端(duan)(duan)設備在(zai)上、一端(duan)(duan)在(zai)下時,可部分架(jia)空(kong)敷(fu)設,當地下水位較高時,宜架(jia)空(kong)。
70、電力電纜的(de)內屏(ping)蔽(bi)層與外屏(ping)蔽(bi)層各在什么(me)部位(wei)?采(cai)用(yong)(yong)什么(me)材料?有何(he)作用(yong)(yong)?
答:為了使絕(jue)緣層和(he)電纜導(dao)體(ti)有(you)(you)較好的(de)(de)接觸,消除(chu)導(dao)體(ti)表面的(de)(de)不光滑(hua)引起的(de)(de)導(dao)體(ti)表面電場(chang)強(qiang)度(du)的(de)(de)增(zeng)加(jia),一般(ban)在導(dao)體(ti)表面包(bao)有(you)(you)金屬(shu)化(hua)紙或(huo)半導(dao)體(ti)紙帶的(de)(de)內屏(ping)(ping)蔽(bi)層。為了使絕(jue)緣層和(he)金屬(shu)護套有(you)(you)較好的(de)(de)接觸,一般(ban)在絕(jue)緣層外(wai)表面包(bao)有(you)(you)外(wai)層屏(ping)(ping)蔽(bi)層。外(wai)屏(ping)(ping)層與內屏(ping)(ping)層的(de)(de)材料(liao)相同,有(you)(you)時還外(wai)扎銅(tong)帶或(huo)編織(zhi)銅(tong)絲帶。
71、簡述環氧(yang)樹脂復合物(wu)的構成及性(xing)能(neng)。
答:環氧樹脂復合物(wu)由環氧樹脂加入(ru)硬化劑(ji)、填充(chong)劑(ji)增韌劑(ji)和稀釋劑(ji)組(zu)成。具有以(yi)下性能:
(1)有足(zu)夠的機械(xie)強(qiang)度;
(2)電氣性能(neng)優良;
(3)電(dian)氣性(xing)能穩(wen)定(ding);
(4)與有(you)(you)色金屬(shu)有(you)(you)足(zu)夠(gou)的黏附力;
(5)耐腐蝕性好;
(6)戶外使用時,耐(nai)雨、耐(nai)光、耐(nai)濕熱(re)。
72、單芯電(dian)纜護套(tao)一端(duan)接地方式中為什么必須安(an)裝一條沿電(dian)纜平行(xing)敷設(she)的回流線(xian)?
答:在金(jin)屬護(hu)套一(yi)端(duan)接(jie)(jie)地(di)(di)的(de)電(dian)纜線(xian)路(lu)中,為(wei)(wei)確保護(hu)套中的(de)感應電(dian)壓不超過允許標準(zhun),必須安(an)裝一(yi)條沿電(dian)纜線(xian)路(lu)平(ping)行敷設(she)的(de)導體(ti),且(qie)導體(ti)的(de)兩端(duan)接(jie)(jie)地(di)(di),這種(zhong)導體(ti)稱為(wei)(wei)回流(liu)線(xian)。當(dang)發生單相接(jie)(jie)地(di)(di)故障時(shi),接(jie)(jie)地(di)(di)短路(lu)電(dian)流(liu)可以(yi)通(tong)過回流(liu)線(xian)流(liu)回系統中心點(dian),由于通(tong)過回流(liu)線(xian)的(de)接(jie)(jie)地(di)(di)電(dian)流(liu)產(chan)生的(de)磁通(tong)抵消了一(yi)部(bu)分電(dian)纜導線(xian)接(jie)(jie)地(di)(di)電(dian)流(liu)所產(chan)生的(de)磁通(tong),因而可降低短路(lu)故障時(shi)護(hu)套的(de)感應電(dian)壓。
73、電纜工程可劃分為幾(ji)個(ge)項目?
答:(1)工地運輸(shu):包括工程(cheng)材料從(cong)倉庫到施(shi)工點(dian)的(de)裝卸、運輸(shu)和(he)空(kong)車回程(cheng)。
(2)地方工程:包括路(lu)面開(kai)挖、隧、溝道施(shi)工等。
(3)敷(fu)設工程:包括(kuo)敷(fu)設、中間(jian)頭制作、掀蓋板、埋管、校潮、牽引頭制作等(deng)。
(4)兩端(duan)(duan)工程(cheng):包括(kuo)支、吊橋架和其基礎的制作(zuo)安裝(zhuang),終端(duan)(duan)頭制作(zuo),油壓力和信號(hao)裝(zhuang)置的安裝(zhuang),名種電氣(qi)性能測(ce)試(shi)等(deng)。
(5)塞止工(gong)程:包括充(chong)油電纜塞止頭(tou)制作(zuo),供(gong)油箱、自動排水及信號裝置(zhi)的安裝等。
(6)接(jie)地工程(cheng):包括絕緣(yuan)接(jie)頭、換位箱、保護器、接(jie)地箱安裝等。
74、電纜(lan)線路的驗收應(ying)進行哪(na)些檢(jian)查?
答:(1)電纜規格應符合規定,排(pai)列應整齊,無損傷,標牌齊全、正確、清晰;
(2)電(dian)纜(lan)的固定彎曲半(ban)徑、有關(guan)距離及(ji)單芯(xin)電(dian)力電(dian)纜(lan)的金屬護層(ceng)的接線應(ying)符合要求;
(3)電(dian)纜終端(duan)、中間頭不(bu)滲漏油,安裝牢固,充(chong)油電(dian)纜油壓及表計(ji)整(zheng)定值應符合要求;
(4)接地良好(hao);
(5)電纜終端相色正(zheng)確,支架等(deng)的金(jin)屬部(bu)件(jian)油(you)漆完整;
(6)電纜溝及(ji)隧道(dao)內(nei)、橋架上(shang)應(ying)無雜物,蓋板齊(qi)全。
75、電纜線(xian)路正序(xu)阻抗測量過程中有什么要求?
答(da):電纜導體的(de)交(jiao)流(liu)電阻和電纜三(san)相同感抗的(de)相量和稱為(wei)正序阻抗。
電纜線路的(de)(de)正(zheng)序阻抗一般(ban)(ban)可在電纜盤上直接測量(liang),測量(liang)時(shi)(shi)(shi)(shi)一般(ban)(ban)使用較(jiao)低的(de)(de)電壓(ya)(ya),因此,需要(yao)用降(jiang)壓(ya)(ya)變壓(ya)(ya)器進行(xing)降(jiang)壓(ya)(ya),降(jiang)壓(ya)(ya)器采用星形(xing)接線,容量(liang)一般(ban)(ban)為10kVA以(yi)上,有較(jiao)廣(guang)的(de)(de)電壓(ya)(ya)調(diao)節(jie)范圍,測量(liang)時(shi)(shi)(shi)(shi)交流(liu)電源(yuan)應比較(jiao)穩定(ding),以(yi)保證測量(liang)時(shi)(shi)(shi)(shi)電流(liu)達到規定(ding)的(de)(de)要(yao)求,實(shi)際電壓(ya)(ya)表(biao)的(de)(de)讀數(shu)值(zhi)必須是電纜端(duan)的(de)(de)電壓(ya)(ya),試驗電流(liu)更(geng)好 接近(jin)電纜長(chang)期允許載流(liu)量(liang),測讀各表(biao)計的(de)(de)數(shu)值(zhi)時(shi)(shi)(shi)(shi),合(he)上電流(liu)后(hou)同(tong)時(shi)(shi)(shi)(shi)讀取三個表(biao)的(de)(de)數(shu)值(zhi)。
76、根據(ju)《電業生(sheng)產安(an)全規定》,電氣工作(zuo)人員必須具(ju)備的(de)條件是什么?
答:必須(xu)具備下(xia)列條(tiao)件:
(1)經醫生鑒定(ding)身(shen)體健康,無妨(fang)礙(ai)工作的病癥;
(2)具(ju)備必(bi)要的(de)電氣知(zhi)識,按其職務和工(gong)作性質掌握相關的(de)規程、專業(ye)技術(shu)及安全操作技術(shu),并經考試合格;
(3)熟練掌握觸電急救方法。
77、電(dian)纜在運輸裝卸過程中應注意什么(me)?
答:(1)在運輸裝(zhuang)卸過程中,不(bu)(bu)應(ying)使電(dian)纜及電(dian)纜盤受到(dao)損傷(shang),嚴禁(jin)將電(dian)纜盤直(zhi)接(jie)由(you)車上推下,電(dian)纜般不(bu)(bu)應(ying)平放運輸,平放貯存(cun)。
(2)運輸或(huo)滾動電(dian)(dian)纜(lan)(lan)(lan)盤前,必須保證電(dian)(dian)纜(lan)(lan)(lan)盤牢固,電(dian)(dian)纜(lan)(lan)(lan)繞緊(jin)、充油電(dian)(dian)纜(lan)(lan)(lan)至壓(ya)力油箱間的油管應(ying)(ying)(ying)固定,不得損傷,壓(ya)力油箱應(ying)(ying)(ying)牢固,壓(ya)力指(zhi)示(shi)應(ying)(ying)(ying)符合要求。
78、電纜防火有哪些措施?
答:(1)采用阻燃(ran)電纜;
(2)采(cai)用防火電(dian)纜托架;
(3)采用防火涂料;
(4)電纜隧(sui)道、夾(jia)層(ceng)出口等(deng)處設置防(fang)(fang)火(huo)隔墻、防(fang)(fang)火(huo)擋(dang)板(ban);
(5)架空(kong)電纜(lan)應(ying)避(bi)開油管道、防(fang)爆門,否則應(ying)有(you)要取局(ju)部穿(chuan)管或隔熱(re)防(fang)火(huo)措施(shi)。
79、選擇電力電纜的截面應從(cong)哪幾個方(fang)面考慮?
答:應考(kao)慮如下幾個(ge)方面(mian):
(1)電(dian)纜長(chang)期允(yun)許通過的工(gong)作(zuo)電(dian)流;
(2)一旦(dan)短路時的(de)熱穩(wen)定性;
(3)線路(lu)上的電壓降不能超出允(yun)許工作范圍。
80、電(dian)力(li)電(dian)纜和架(jia)空線比較有哪些優點?
答:(1)運行可靠(kao),由于安(an)裝在地下(xia)等隱蔽處,受外力(li)破壞小,發(fa)生(sheng)故障的機會較少,供電安(an)全(quan),不會給(gei)人身(shen)造(zao)成(cheng)危害(hai);
(2)維護工作量小(xiao),不需頻繁的巡檢;
(3)不需架設桿塔;
(4)有助于提高功(gong)率因數。